My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 E Seventeenth St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Seventeenth St
>
2000 E Seventeenth St
>
2000 E Seventeenth St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2026 5:00:11 AM
Creation date
3/26/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20187470
101125799
Full Address
2000 E Seventeenth St
Street Number
2000
Street Direction
E
Street Name
Seventeenth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br />CARUSO <br />TURLEY <br />SCOTT <br />structural <br />engineers <br />STRUCTURAL <br />ENGINEERING <br />EXPERTS <br /> <br />PARTNERS <br />Sandra Herd, SE, PE, LEED AP <br />Thomas Morris, SE, LEED AP <br />Richard Dahlmann, SE, PE <br />Troy Turley, SE, PE, LEED AP <br />Brady Notbohm, SE, PE <br />PROFESSIONAL <br />REGISTRATION <br /> <br />50 States <br />Washington D.C. <br />U.S. Virgin Islands <br />Puerto Rico <br />1215 W. Rio Salado Pkwy. <br />Suite 200 <br />Tempe, AZ 85281 <br />T: (480) 774-1700 <br />F: (480) 774-1701 <br />www.ctsaz.com <br /> <br /> <br />Date: November 9, 2025 <br /> <br /> <br />Mr. Ryan Heil <br />PanelClaw <br />1600 Osgood Street, Ste. 2023 <br />North Andover, MA 01845 <br /> <br />RE: Evaluation of PanelClaw system <br /> <br />Project Name: Albertson 598 <br />CTS Job No.: 23-0242-2984.2 <br /> <br />Per the request of Ryan Heil at PanelClaw, CTS was asked to review the <br />PanelClaw racking system with respect to the system’s ability to resist uplift and <br />sliding caused by wind and seismic loads. <br /> <br />Wind Evaluation: <br /> <br />PanelClaw has provided CTS with wind tunnel testing performed by CPP, Inc. <br />The system tested was the “clawFR 10 Degree Dual Tilt” system. This system <br />consists of photovoltaic panels installed at a 10 degree tilt onto support <br />assemblies. The support assemblies consist of a support frame for the PV <br />panels, wind deflectors and areas for additional mass/weight as required for the <br />ballast loads. <br /> <br />The wind tunnel testing was performed per Chapter 31 of ASCE 7-16. The <br />parameters of the testing were a flat roof system in both Exposure B and C on a <br />building with and without parapets. The testing has resulted in pressure and/or <br />force coefficients that were applied to the velocity pressure q z in order to obtain <br />the wind loads on the PV system. From the wind load results it is then possible to <br />calculate the ballast loads required to resist the uplift and sliding forces. <br /> <br />PanelClaw has provided CTS with the excel tool that was developed to obtain the <br />uplift and sliding forces. CTS has reviewed this tool and the wind forces obtained <br />to find that the amounts of ballast and mechanical attachments provided are <br />within the values required. Furthermore, CTS agrees with the methodologies <br />used to develop the uplift and sliding forces for the “clawFR 10 Degree Dual Tilt” <br />system per the wind tunnel testing results. <br /> <br />Seismic Evaluation: <br /> <br />CTS was asked to review the PanelClaw system to determine attachments <br />required to resist seismic loading of the ballasted solar support system on the <br />roof of the existing building. Following CBC Load Combination 16-16 and ASCE <br />Section 2.4.5, the Dead Load value has been reduced by subtracting the vertical <br />component of the seismic forces (0.6*D - 0.14Sds*D). The contribution of friction <br />due to the component weight was not considered to resist lateral forces caused <br />by seismic loads per ASCE Section 13.4. <br /> <br />Utilizing this method, calculations have been provided for the number of <br />mechanical attachments that are required to resist seismic forces that are applied <br />to the system. <br />
The URL can be used to link to this page
Your browser does not support the video tag.