Laserfiche WebLink
7.0 Design Loads - Seismic (Cont.): <br />7.4 Vertical Seismic Force Check: <br />Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table <br />below provides the mechanical attachment requirements for each sub-array within this project. <br />Nomenclature: <br />WP = Sub-Array Weight <br />FPV = Vertical Seismic Force <br />FRV = Vertical Seismic Resisting Force <br />Array Information Vertical Force Verification Results <br />Sub- <br />Array <br />Name <br />WP <br />(lbs.) <br />FPV <br />(lbs.) <br />FRV <br />(lbs.) <br />0.7 FPV - <br />FRV (lbs.) <br />MA's <br />Required <br />Total MA <br />Capacity <br />(lbs.) <br />Total <br />MA's <br />Provided <br />Acceptable <br />1.1 1,600 334 960 -726 0 2,940 9 Yes <br />1.2 3,888 812 2,333 -1,764 0 3,998 13 Yes <br />1.3 11,380 2,378 6,828 -5,163 0 7,623 23 Yes <br />1.4 12,264 2,563 7,359 -5,565 0 4,005 12 Yes <br />1.5 11,153 2,330 6,692 -5,060 0 3,860 11 Yes <br />1.6 9,889 2,066 5,934 -4,487 0 3,088 10 Yes <br />1.7 9,778 2,043 5,867 -4,437 0 3,443 10 Yes <br />1.8 8,254 1,725 4,952 -3,745 0 3,441 10 Yes <br />Total:68,206 lbs.14,252 lbs.40,924 lbs.-30,947 lbs.0 32,397 98 <br />Table7.2 - Summary of Mechanical Attachment Requirements <br />* MA's Required = 0.7 FPV - FRV/MA strength <br />07/09/2024 <br />15 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br />(978) 688.4900 - www.panelclaw.com