Laserfiche WebLink
3.0 Wind Load: <br />Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 <br />3.1 Wind Load Data: <br />Basic Wind Speed (Vult) =95 mph (ASCE, Fig. 26.5-1) <br />Exposure Category:C (ASCE, Sec. 26.7.3) <br />Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) <br />Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) <br />Exposure Coefficient (Kz) =0.94 (ASCE, Table 26.10-1) <br />Ground Elevation Factor (Ke) =0.99 (ASCE, Table 26.9-1) <br />Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =18.29 psf (ASCE, Eqn. 26.10-1) <br />3.2 Roof / Array Zone Map: <br />Figure 3-1. Typical corner zone <br />Figure 3-1 shows N/E corner wind direction. Wind zones are symmetrical, and all <br />building corners experience the same pattern of loads (with zone E connecting corner <br />zones along east and west building edges). <br />Roof Zone Map Dimensions per CPP Wind Tunnel Study <br />Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) <br />24 24.00 18.29 <br />*LB = Characteristic length per wind tunnel study <br />3.3 Wind Design Equations: <br />FL = qz Aref GCL FL = sum of lift on panel. <br />FD = qz Aref GCD FD = sum of drag on panel. <br />FL - D Companion = qz Aref GCL - D Companion <br />FL - D Companion = The accompanying uplift corresponding to <br />maximum drag. <br />Where <br />qz = Velocity Pressure (Ref. Section 3.1, Wind Load) <br />Aref = Module Area (Ref. Section 1.1, General) <br />GCL GCD , GCL-D Companion= Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) <br />07/09/2024 <br />7 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br />(978) 688.4900 - www.panelclaw.com