Laserfiche WebLink
*-SANTA <br />ANA <br />ILI\\IIG <br />ttfl-0trG <br />1cIcl <br />Plannlng & Bulldlng Agency <br />Bulldlng Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-s800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />soL-01 cBc 2013 <br />Solar Photovollaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contraclor of record shall complete all sections, answer lhe ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answerinq NO to any of the questions, plan ch6ck shall be required. <br />Project Address:1822W Red Fox Rd, Santa Ana, CA 92704, US <br />Contractor Company n"r". Solar City <br />888104Contractor License Number: <br />1 <br />YES NOtrtr Are the following appllcablo to the proposed project? <br />Will the PV system layoul provide the required three-foot wide clear access pathways <br />per Section 605.11 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2' minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />sYstem? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with predrilled holes) and is this minimum embedment <br />shown on the plans? <br />A16 ALL the structural pages of the plans WET stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />4 <br />5 <br />a <br />b <br />7 <br />o <br />Etr <br />OB <br />trD <br />Eltr <br />trtr <br />trtr <br />Ettr <br />9 EIEI <br />10 trtr <br />I certify under psnalty ot perjury under the laws of tha State of Callfornia that the above is true: <br />print Name: Brian Park Signature <br />Phone Number: 6464061 555 <br />Emait Address: brpark@tesla. com <br />Revr 8/1712015 <br />Date. 12118/20