FEC <br />FE <br />C <br />FE <br />C <br />FE <br />C <br />FE <br />C <br />FE <br />C <br />FE <br />C <br /># <br />LEGEND <br />OCCUPANT LOAD, SUB AREA <br />CUMULATIVE ROOM/ AREA OCCUPANT LOAD <br />F.E.C.FIRE EXTINGUISHER CABINET LOCATION <br />### <br />EXITING DIRECTION, NUMBER OF <br />OCCUPANTS EXITING <br />DRINKING FOUNTAIN WITH BOTTLE FILLERD.F. <br />EGRESS PATH FROM REMOTE LOCATIONS <br />### <br />### <br />EXITING LOAD TO THE EXTERIOR <br />EXITING LOAD TO THE ADJACENT ROOM <br />ACCESSORY SPACES, EXCLUDED FROM <br />OCCUPANT LOAD CALCULATION <br />ACCESSIBLE PATH FROM ENTRY TO <br />PROGRAM SPACES <br />16 <br />15 <br />17 17 <br />2 4 7 <br />YOUTH <br />STACKS <br />117 <br />GREAT <br />READING <br />ROOM <br />101 <br />TODDLERS <br />AND <br />INFANTS <br />120 <br />FAMILY <br />ZONE <br />121 <br />YOUTH <br />STACKS <br />118 <br />ADULT <br />STACKS <br />119 <br />SORTING <br />123 <br />BOOKMOBILE <br />ROOM <br />103 <br />MECH. <br />113 <br />ALL GENDER <br />RESTROOM <br />114 <br />ALL GENDER <br />RESTROOM <br />115 <br />JAN. RM <br />112 <br />WOMEN RR <br />111 <br />MEN RR <br />110 <br />STAFF MEN <br />RESTROOM <br />105 <br />STAFF-WOMEN <br />RESTROOM <br />104 <br />(E) EGRESS DOOR <br />204 OCC X.2=40.8" <br />72" PROVIDED <br />EGRESS DOOR <br />225 OCC X.2=45" <br />60" PROVIDED <br />(N) EGRESS DOOR <br />118 OCC X.2=23.6" <br />34" PROVIDED <br />81 <br />2 <br />NURSING/SENSORY <br />116 <br />STORAGE <br />1081 <br />154 <br />MEETING/COMMUNITY <br />ROOM <br />102 <br />OFFICE <br />103A <br />1 <br />?From <br />Basement <br />From <br />Basement <br />From 2F <br />52' <br />97 <br />' <br /> <br />- <br /> <br />5 <br /> <br />3 <br />/ <br />8 <br />" <br />34' <br />61'-6" <br />23' <br />1' <br /> <br />- <br /> <br />6 <br />" <br />VESTIBULE <br />100 <br />I.T. <br />106 <br />VESTIBULE <br />107 <br />BOOKSTORE <br />109 <br />STORAGE <br />124 <br />1 1 <br />1 1 <br />1 <br />1 2 <br />5 7 <br />11 <br />8 <br />16 <br />273 <br />273/3+81/3=118 <br />171/2+273/3+81/3=204 <br />21+171/2+273/3+81/3=225 <br />FEC <br />FEC <br />6 <br />38 38 <br />From <br />Basement <br />63 From 2F 63 <br />149 <br />136 <br />83 <br />16 <br />PER CBC TABLE 1006.3.1: MINIMUM NUMBER OF EXITS OR ACCESS <br />TO EXITS PER STORY FOR A BUILDING WITH OCCUPANT LOAD OF <br />1-500 SHALL BE 2. <br /> <br />BASED ON CBC 2022 SECTION 1011.2: MIN STAIRWAY WIDTH 44". <br />BASED ON CBC 2022 SECTION 1011.2 EXCEPTION 1: MIN STAIRWAY <br />WIDTH 36" WHEN OCCUPANT LOAD LESS THAN 50. <br />PER CBC TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE: <br />OCCUPANCY A WITH SPRINKLER SYSTEM MAXIMUM IS 250'. ALL <br />TRAVEL DISTANCES ARE WITHIN 250' <br />PER CBC 1007.1.2 AND 1007.1.1 EXCEPTION 2: TWO OR MORE EXIT <br />ACCESS DOORWAYS ARE REQUIRED, NOT LESS THAN TWO EXIT <br />ACCESS DOORWAYS SHALL BE PLACED AT DISTANCE APART <br />EQUAL TO NOT LESS THAN 1/3 THE LENGTH OF THE MAXIMUM <br />OVERALL DIAGONAL. <br />MAX. OVERALL DIAGONAL = 214' - 9", 1/3 OF MAX. OVERALL <br />DIAGONAL = 71' - 7" <br />EXIT SEPARATION AD = 98', BD = 117' - 5", AB = 94' <br />ALL MEET THE CODE REQUIREMENT. <br />ACCESSIBLE EGRSS EXIT-B <br />ACCESSIBLE <br />EGRSS EXIT-A <br /> ACCESSIBLE EXIT-C <br />ACCESSIBLE <br />EGRSS EXIT-D <br /> ACCESSIBLE <br />EXIT-E <br />MAX <br />. <br /> <br />D <br />I <br />A <br />G <br />O <br />N <br />A <br />L <br />50' <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />MAX. DIAG <br />O <br />N <br />A <br />L <br />214' - 8 3/4 <br />" <br />36 <br />' <br /> <br />- <br /> <br />6 <br /> <br />3 <br />/ <br />4 <br />" <br />MAX. OVERALL DIAGONAL = 50' - 1" <br />EXIT SEPARATION = 36' - 7" <br />36' - 7"/ 50' - 1" = 0.73 > 0.333 = OK <br />70'-4" <br />9'-0" <br />9'-0" <br />32'-10" <br />43'-10" <br />7'-0"10'-1"59'-10" <br />59'-6" <br />59'-1"4'-0" <br />30'-0" <br />38'-6" <br />98' <br />117'-5" <br />94' <br />51'-11" <br />A1.1-2 <br />20 <br />A1.0-2 <br />3 <br />STAFF <br />OFFICE <br />001 <br />ARCHIVES <br />002 <br />MECH <br />003 <br />FIRE AL.RM <br />006 <br />ELEVATOR-ABAN. <br />007 <br />MECH-ABAN. <br />008 <br />43 <br />11 <br />4 <br />ALL GENDER <br />RESTROOM <br />010 <br />EGRESS STAIR <br />38 X.3=11.4" <br />44" PROVIDED <br />EGRESS STAIR <br />38 X.3=11.4" <br />44" PROVIDED <br />76 <br />OFFICE <br />012 <br />OFFICE <br />013 <br />STAFF <br />MEETING <br />ROOM <br />014 <br />OFFICE <br />015 <br />OFFICE <br />017 <br />STAFF <br />BREAK <br />ROOM <br />004 <br />(E) ELEV. <br />CONTROL <br />RM. <br />005A <br />ELEV. <br />CONTROL <br />018 <br />1 <br />120' - 0" <br />1 1 1 1 <br />3 <br />1 1 1 <br />1 <br />1 <br />25'-8" <br />20'-4" <br />7' <br />40'-5" <br />OFFICE <br />016 <br />ELECTRICAL <br />019 <br />ELEVATOR <br />LOBBY <br />009 <br />1 <br />1 ? <br />FEC <br />STORAGE <br />005 2 <br />13 <br />6 <br />6 <br />38 <br />38 <br />PER CBC TABLE 1006.3.1: MINIMUM NUMBER OF EXITS OR ACCESS <br />TO EXITS PER STORY FOR A BUILDING WITH OCCUPANT LOAD OF <br />1-500 SHALL BE 2. <br /> <br />BASED ON CBC 2022 SECTION 1011.2: MIN STAIRWAY WIDTH 48". <br />BASED ON CBC 2022 SECTION 1011.2 EXCEPTION 1: MIN STAIRWAY <br />WIDTH 36" WHEN OCCUPANT LOAD LESS THAN 50. <br />PER CBC 1007.1.2 AND 1007.1.1 EXCEPTION 2: TWO OR MORE EXIT <br />ACCESS DOORWAYS ARE REQUIRED, NOT LESS THAN TWO EXIT <br />ACCESS DOORWAYS SHALL BE PLACED AT DISTANCE APART <br />EQUAL TO NOT LESS THAN 1/3 THE LENGTH OF THE MAXIMUM <br />OVERALL DIAGONAL. <br />MAX. OVERALL DIAGONAL = 147' - 9", 1/3 OF MAX. OVERALL <br />DIAGONAL = 49' - 3" <br />EXIT SEPARATION = 112' - 6", MEETS THE CODE REQUIREMENT. <br />MAX. D <br />I <br />A <br />G <br />O <br />N <br />A <br />L <br />147' - <br />9 <br /> <br />1 <br />/ <br />4 <br />" <br />27'-9" <br />68'-8" <br />58'-6" <br />8'-10" <br />13'-0" <br />26'-2" <br />53'-6" <br />21'-2" <br />30'-4" <br />8'-5" <br />10'-8" <br />23'-2" <br />5'-1" <br />20'-4" <br />14'-0" <br />#311 <br />RFI <br />PER CBC TABLE 1006.3.1: MINIMUM NUMBER OF EXITS OR ACCESS <br />TO EXITS PER STORY FOR A BUILDING WITH OCCUPANT LOAD OF <br />501-1,000 SHALL BE 3. <br /> <br />BASED ON CBC 2022 SECTION 1011.2: MIN STAIRWAY WIDTH 44". <br />PER CBC 1007.1.2 AND 1007.1.1 EXCEPTION 2: THREE OR MORE <br />EXIT ACCESS DOORWAYS ARE REQUIRED, NOT LESS THAN TWO <br />EXIT ACCESS DOORWAYS SHALL BE PLACED AT DISTANCE APART <br />EQUAL TO NOT LESS THAN 1/3 THE LENGTH OF THE MAXIMUM <br />OVERALL DIAGONAL. <br />MAX. OVERALL DIAGONAL = 298' - 8" <br />EXIT SEPARATION = 155' - 2" <br />155' - 2"/ 298' - 8" = 0.51 > 0.333 = OK <br />ST <br />09-30-2027 <br />O <br />ARCHITECT <br />FOFCALE <br />REN. <br />AT ARN <br />NO. <br />SE <br />LICNE <br />C-27893 <br />D <br />T <br />EC <br />HIT <br />ARC <br />DAVID SCHNEE <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />F R A N CN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />N D E N VA <br />,N I N G <br />CRAE <br />TCEIT <br />S C <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />0718 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />PERMIT SET 1ST ISSUANCE <br />BID SET <br />FINAL PERMIT/CONFORM SET <br />09/29/2023 <br />04/30/2024 <br />08/02/2024 <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />REV # DESCRIPTION DATE <br />1 BACKCHECK REV-1 03.01.2024 <br />2 CITY REVIEW REV-1 08.02.2024 <br />3 CITY REVIEW REV-2 10.18.2024 <br />4 CITY REVIEW REV-3 01.27.2025 <br />5 CITY REVIEW REV-4 04.07.2025 <br />6 CITY REVIEW REV-5 06.27.2025 <br />7 CITY REVIEW REV-6 10.24.2025 <br />8 CITY REVIEW REV-7 02.06.2026 <br /> REVIEWED FOR CONSTRUCTABILITY: <br /> 80470 <br />SEAN THOMAS. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />RECOMMENDED FOR CONSTRUCTION: <br /> 62968 <br />JASON GABRIEL. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />A0.4-1 <br />CODE- EXITING <br />PLAN <br />OCCUPANT LOAD FOR EXITING <br />ROOM FUNCTION OF SPACE RM NAME AREA OLF <br />OCCUPANT <br />LOAD <br />010 ACCESSORY-BUSINESS STAFF RR.Not <br />Placed <br />150 <br />023 BUSINESS SKYLIGHT-1 Not <br />Placed <br />150 <br />024 BUSINESS SKYLIGHT-2 Not <br />Placed <br />150 <br />025 BUSINESS SKYLIGHT-3 Not <br />Placed <br />150 <br />026 BUSINESS FIREPLACE RM Not <br />Placed <br />150 <br />027 Not <br />Placed <br />028 Not <br />Placed <br />029 Not <br />Placed <br />030 BUSINESS FIREPLACE RM Not <br />Placed <br />150 <br />031 Not <br />Placed <br />102C Not <br />Placed <br />001 BUSINESS STAFF OFFICE 6321 SF 150 43 <br />002 A-3 ARCHIVES 1063 SF 100 11 <br />003 MEP MECH 1065 SF 300 4 <br /> 3/32" = 1'-0"19 FP01- FIRST FLOOR PLAN - EXITING <br /> 3/32" = 1'-0"03 BASEMENT EXITING <br />OCCUPANT LOAD FOR EXITING <br />ROOM FUNCTION OF SPACE RM NAME AREA OLF <br />OCCUPANT <br />LOAD <br />004 BUSINESS STAFF BREAK RM 399 SF 150 3 <br />005 BUSINESS STAFF MEETING RM 221 SF 150 2 <br />005A MEP ELEV. CONTROL 54 SF 300 1 <br />005B BUSINESS VESTIBULE 78 SF <br />006 ACCESSORY-STORAGE FIRE AL.RM.48 SF 300 1 <br />007 ACCESSORY-STORAGE ELEV.-ABAN.41 SF 300 1 <br />008 ACCESSORY-STORAGE MECH-BABN.57 SF 300 1 <br />009 NON-ASSIGNABLE VESTIBULE 310 SF <br />010 ACCESSORY-BUSINESS STAFF RR.76 SF 150 1 <br />011 74 SF <br />012 BUSINESS OFFICE 120 SF 150 1 <br />013 BUSINESS OFFICE 122 SF 150 1 <br />014 ACCESSORY-STORAGE STORAGE 173 SF 300 1 <br />015 BUSINESS OFFICE 128 SF 150 1 <br />016 BUSINESS OFFICE 124 SF 150 1 <br />017 BUSINESS OFFICE 127 SF 150 1 <br />018 MEP ELEV. CONTROL 46 SF 300 1 <br />019 MEP ELECTRICAL 186 SF 300 1 <br />021 26 SF <br />022 22 SF <br />023 22 SF <br />ST-1 126 SF <br />ST-2 78 SF <br />ST-3 40 SF <br />100 NON-ASSIGNABLE VESTIBULE 326 SF <br />101 A-3 READING GREAT READING RM 4023 SF 50 81