Laserfiche WebLink
STUD AT JAMB, S. S. 4/ S6.0-2 <br />CONT. SEALANT AND <br />BACKER ROD <br />5/8" GYPSUM BD, PTD. <br />CORNER BEAD, PTD. <br />5/8" GYPSUM BD, PTD. <br />THRESHOLD W/ MITERED RETURN <br />DOOR & HARDWARE, SEE <br />DOOR SCHEDULE <br />2" <br />4 <br />1 <br />/ <br />2 <br />" <br />ALIGN <br />PARTITION AS <br />SCHEDULED, SEE PLANS <br />FOR WALL TYPE <br />PARTITION AS SCHEDULED, <br />SEE PLAN FOR WALL TYPE <br />ROOM INSIDE <br />ROOM OUTSIDE <br />FOR WALL THICKNESS, <br />SEE FLOOR PLANS FOR <br />TYPE & PARTITION <br />SCHEDULE FOR <br />ASSEBLY <br />STUD AT JAMB, S. S. 4/ <br />S6.0-2 <br />DOOR FRAME. <br />PAINTED <br />SEE DOOR SCHEDULE <br />FOR DOOR TYPE AND <br />HARDWARE <br />INSULATION, WHERE <br />OCCURS <br />1" <br />1 1/2" <br />1 1/2" <br />1" <br />FOR WALL THICKNESS, <br />SEE FLOOR PLANS FOR <br />TYPE & PARTITION <br />SCHEDULE FOR <br />ASSEBLY <br />STUD AT HEADER, S. S. 2/ <br />S6.0-2 <br />DOOR FRAME. <br />PAINTED <br />SEE DOOR SCHEDULE <br />FOR DOOR TYPE AND <br />HARDWARE <br />INSULATION, WHERE <br />OCCURS <br />1" <br />1 <br />1 <br />/ <br />2 <br />" <br />FLOOR TRANSITION AT CENTER OF DOOR <br />1. FLOOR TRANSITION/ THRESHOLD= MAX. 1:2 RISE:RUN, TYP. <br />2. SEE A9.2-1 FOR ADDITIONAL INFO ON FLOOR TRANSITIONS <br />3. WHERE THERE IS NO CHANGE IN FINISH, NO THRESHOLD IS REQUIRED. <br />DOOR JAMB MULLION <br />BEYOND <br />DOOR & HARDWARE, <br />SEE DOOR SCHEDULE <br />FLOOR FINISH, SEE <br />FINISH PLAN & <br />SCHEDULE, TRANSITION <br />AT CL OF DOOR, UNLESS <br />OTHERWISE NOTED <br />DOOR THRESHOLD <br />W/ MITERED <br />RETURN, WHERE <br />OCCURS <br />PARTITION EDGE <br />BEYOND, SEE PLANS <br />FOR WALL TYPE <br />3/4"1/2"3/4" <br /> P <br />E <br />R <br /> <br />S <br />P <br />E <br />C <br />S <br />. <br />UN <br />D <br />E <br />R <br />C <br />U <br />T <br />STUD AT HEADER, S. S. <br />2/ S6.0-2 <br />INT. DOOR HEAD <br />MULLION <br />CONT. SEALANT AND <br />BACKER ROD, TYP. <br />5/8" GYPSUM BD, PTD. <br />CORNER BEAD, PTD. <br />INSULATION, WHERE <br />OCCURS, SEE WALL <br />TYPE <br />PARTITION AS <br />SCHEDULED, SEE PLAN <br />FOR WALL TYPE <br />GLAZING, SEE DOOR <br />SCHEDULE <br />ROOM INSIDEROOM OUTSIDE <br />AL <br />I <br />G <br />N <br />2" <br />4 1/2" <br />DOOR JAMB MULLION <br />BEYOND <br />DOOR, SEE SCHEDULE <br />PARTITION EDGE <br />BEYOND, SEE PLAN <br />FOR WALL TYPE <br />FLOOR TRANSITION AT CENTER OF DOOR <br />5 1/4"2" <br />1. FLOOR TRANSITION/ THRESHOLD= MAX. 1:2 RISE:RUN, TYP. <br />2. SEE A9.2-1 FOR ADDITIONAL INFO ON FLOOR TRANSITIONS <br />FLOOR FINISH, SEE <br />FINISH PLAN & <br />SCHEDULE, <br />TRANSITION AT CL OF <br />DOOR, UNLESS <br />OTHERWISE NOTED <br />DOOR THRESHOLD W/ <br />MITERED RETURN, <br />WHERE OCCURS <br />0' - 0 1/2" MIN. <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />1/2" MIN. <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />GLAZING, SEE DOOR <br />SCHEDULE <br />WALL STUD DEPTH X 25 GA. MET. <br />STUDS 16" O.C. <br />STUD AT HEADER, S. S. 2/ S6.0-2 <br />5/8" GYP. BD., PTD. <br />ALUM. SNAP-ON CASING <br />ALUM. DOOR FRAME <br />DOOR, SEE SCHEDULE <br />DOOR STOP <br />INSULATION, WHERE <br />OCCURS <br />STUD AT JAMB, S. S. 4/ S6.0-2 <br />INSULATION PER PARTITION <br />SCHEDULE <br />GYP. BD., PTD. <br />PARTITION AS SCHEDULED <br />ALUM. SNAP-ON CASING <br />ALUM. DOOR FRAME W/ DOOR <br />STOP <br />DOOR, SEE SCHEDULE <br />1 1/2" <br />DOOR, SEE SCHEDULE <br />ALUM. DOOR FRAME W/ DOOR STOP <br />ALUM. SNAP-ON CASING <br />STUD AT JAMB, S. S. 4/ S6.0-2 <br />INSULATION PER PARTITION <br />SCHEDULE <br />GYP. BD., PTD. <br />STUD DEPTH X 25 GA. STUDS <br />@ 16" O.C. <br />1 1/2" <br />1. FLOOR TRANSITION/ THRESHOLD= MAX. 1:2 RISE:RUN, TYP. <br />2. SEE A9.0-6 FOR ADDITIONAL INFO ON FLOOR TRANSITIONS <br />3. WHERE THERE IS NO CHANGE IN FINISH, NO THRESHOLD IS REQUIRED. <br />DOOR JAMB MULLION BEYOND <br />DOOR, SEE SCHEDULE <br />FLOOR FINISH, SEE FINISH PLAN & <br />SCHEDULE, TRANSITION AT CL OF <br />DOOR, UNLESS OTHERWISE NOTED <br />DOOR THRESHOLD W/ MITERED <br />RETURN, WHERE OCCURS. <br />FLOOR TRANSITION AT CENTER OF DOOR <br />3/4"3/4"3/4" <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />4 1/2" <br />DOOR, SEE SCHEDULE <br />ALUM. DOOR FRAME W/ DOOR STOP <br />ALUM. SNAP-ON CASING <br />STUD AT JAMB, S. S. 4/ S6.0-2 <br />INSULATION PER PARTITION <br />SCHEDULE <br />GYP. BD., PTD. <br />STUD DEPTH X 25 GA. STUDS <br />@ 16" O.C. <br />STUD AT JAMB, S. S. 4/ S6.0-2 <br />INSULATION PER PARTITION <br />SCHEDULE <br />GYP. BD., PTD. <br />PARTITION AS SCHEDULED <br />ALUM. SNAP-ON CASING <br />ALUM. DOOR FRAME W/ DOOR <br />STOP <br />DOOR, SEE SCHEDULE <br />ST <br />09-30-2027 <br />O <br />ARCHITECT <br />FOFCALE <br />REN. <br />AT ARN <br />NO. <br />SE <br />LICNE <br />C-27893 <br />D <br />T <br />EC <br />HIT <br />ARC <br />DAVID SCHNEE <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />F R A N CN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />N D E N VA <br />,N I N G <br />CRAE <br />TCEIT <br />S C <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />0718 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />SHEET NOTES <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />PERMIT SET 1ST ISSUANCE <br />BID SET <br />FINAL PERMIT/CONFORM SET <br />09/29/2023 <br />04/30/2024 <br />08/02/2024 <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />REV # DESCRIPTION DATE <br />1 BACKCHECK REV-1 03.01.2024 <br />2 CITY REVIEW REV-1 08.02.2024 <br />3 CITY REVIEW REV-2 10.18.2024 <br />4 CITY REVIEW REV-3 01.27.2025 <br />5 CITY REVIEW REV-4 04.07.2025 <br />6 CITY REVIEW REV-5 06.27.2025 <br />7 CITY REVIEW REV-6 10.24.2025 <br />8 CITY REVIEW REV-7 02.06.2026 <br /> REVIEWED FOR CONSTRUCTABILITY: <br /> 80470 <br />SEAN THOMAS. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />RECOMMENDED FOR CONSTRUCTION: <br /> 62968 <br />JASON GABRIEL. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />A9.1-1 <br />INTERIOR DETAILS <br />- DOORS <br /> 6" = 1'-0"08 IDR - INT. STOREFRONT DOOR JAMB @ GYP. WALL <br /> 6" = 1'-0"04 IDR - HM. DOOR JAMB <br /> 6" = 1'-0"02 IDR - HM. DOOR FRAME HEAD, TYP. <br /> 6" = 1'-0"01 IDR - INT. DOOR THRESHOLD <br /> 6" = 1'-0"06 IDR - INT. STOREFRONT DOOR HEAD <br /> 6" = 1'-0"05 IDR - INT. STOREFRONT DOOR SILL <br /> 6" = 1'-0"10 IDR - INT. WIN. DOOR HEAD <br /> 6" = 1'-0"12 IDR - INT. WIN. DOOR JAMB STRIKE <br /> 6" = 1'-0"16 IDR - INT. WIN. DOOR JAMB HINGE <br /> 6" = 1'-0"09 IDR - INT. WIN. DOOR SILL <br /> 6" = 1'-0"15 IDR - INT. WIN. DOOR JAMB HINGE AT STUD TRANSFER <br /> 6" = 1'-0"14 IDR - INT. WIN. DOOR JAMB STRIKE AT STUD TRANSFER <br />#349 <br />RFI