Laserfiche WebLink
I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />E1.0-2 <br />ELECTRICAL <br />LIGHTING SITE <br />PLAN <br />1 CONDUITS SERVING SURFACE MOUNTED TRELLIS LIGHT FIXTURES SHALL <br />BE PAINTED TO MATCH COLUMNS. <br />2 EXISTING LIGHTING FIXTURES TO REMAIN AND BE PROTECTED IN PLACE. <br />CIRCUITING IS ASSUMED TO BE CONNECTED BACK TO PANELBOARD "LP" <br />IN BASEMENT LEVEL OF LIBRARY. CONTRACTOR SHALL CONFIRM <br />(CIRCUIT TRACING) AND LABEL CIRCUITING ON RECORD DRAWINGS. <br />CIRCUITING SHALL BE CONNECTED THROUGH NEW LIGHTING CONTROL <br />PANEL (LCP). <br />3 EXISTING LIGHTING FIXTURES TO REMAIN AND BE PROTECTED IN PLACE. <br />RECIRCUIT AS SHOWN AND INDICATED ON SHEET E1.0-2. <br />4 EXISTING LIGHTING IN KIDS EXTERIOR PLAYGROUND AREA TO BE <br />PROTECTED IN PLACE. RECIRCUIT AS SHOWN AND INDICATED ON SHEET <br />E1.0-2. <br />5 EXISTING LIBRARY UNDERGROUND VAULT TO REMAIN. EXISTING <br />ELECTRICAL EQUIPMENT TO BE REMOVED FROM VAULT. NEW PULLBOX <br />TO BE PLACED IN VAULT TO EXTEND FEEDERS TO NEW MAIN <br />SWITCHBOARD LOCATION. <br />GENERAL NOTES <br />KEY NOTES <br />1. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND ELEVATION OF <br />ALL LIGHTING FIXTURES AND ALL LIGHTING CONTROL DEVICES. ALL WALL <br />MOUNTED DEVICES SHALL BE VERIFIED WITH ARCHITECT PRIOR TO ROUGH- <br />IN. <br />2. CONTRACTOR TO REFER TO DRAWING E0.02 FOR FIXTURE SCHEDULE. <br />3. CONTRACTOR IS RESPONSIBLE FOR PROVIDING LIGHTING FIXTURES WITH <br />REQUIRED STRUCTURAL SUPPORTS. <br />4. REFER TO ARCHITECTURAL PLANS FOR EXIT SIGN CHEVRONS AND NUMBER <br />OF FACES PER EXIT SIGN. ANY DISCREPANCIES BETWEEN EXIT SIGNS SHOWN <br />ON ELECTRICAL AND ARCHITECTURAL PLANS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT. <br />5. REFER TO DRAWING E3.03 FOR LIGHTING CONTROL DIAGRAMS AND DETAILS. <br />CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL LOW VOLTAGE WIRING AND <br />COMPONENTS TO PROVIDE A COMPLIANT AND FULLY WORKING LIGHTING <br />CONTROL SYSTEM. <br />6. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED <br />FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR <br />GREATER THAN THE FIRE RATING OF THE WALL. <br />7. CONTRACTOR TO PROVIDE JUNCTION BOXES AS NEEDED FOR A COMPLETE <br />LIGHTING INSTALLATION. THESE ARE NOT SHOWN FOR CLARITY OF <br />DRAWINGS. NO JUNCTION BOXES SHALL BE INSTALLED IN HARD-LID CEILINGS. <br />8. CONTRACTOR TO PROVIDE CONSTANT HOT CIRCUIT TO ALL EXIT SIGNS AND <br />LIGHT FIXTURES PROVIDED WITH 90 MINUTE BATTERY BACKUP FOR EGRESS. <br />9. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED <br />FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR <br />GREATER THAN THE FIRE RATING OF THE WALL. <br />10. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL <br />CONFORM TO CEC, ARTICLE 300.22(C). <br />11. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN <br />CIRCUITRY. <br />12. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE <br />CONTRACTOR SHALL PROVIDE THE FOLLOWING: <br /> 14.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS <br /> 14.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN PARALLEL TO <br />STRUCTURES OR DUCT WORK. <br /> 14.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE REROUTED AT <br />THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. <br />13. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE <br />OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO ONE <br />CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE (9) <br />CURRENT CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS IN <br />EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE <br />BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />14. CONTRACTOR SHALL VERIFY WITH LIGHTING CONTROLS MANUFACTURER <br />THE TYPE QUANTITY AND BEST PLACEMENT OF OCCUPANT AND/OR <br />PHOTOCELL SENSORS AS SHOWN ON FLOOR PLAN. PER TITLE 24, OCCUPANT <br />SENSORS SHALL BE MOUNTED AT LEAST 4FT AWAY FROM AIR SUPPLY <br />REGISTER. <br />15. CONTRACTOR SHALL PROVIDE STARTUP AND COMMISSIONING SERVICES <br />FROM LIGHTING CONTROL MANUFACTURER TO SET UP, ADJUST AND <br />PROGRAM SOFTWARE SYSTEM FOR THE LIGHTING CONTROL SYSTEM TO <br />PROVIDE A COMPLETE AND OPERABLE SYSTEM. <br />16. NOT ALL JUNCTION BOXES ARE SHOWN ON DRAWINGS. CONTRACTOR <br />SHALL PROVIDE FOR A COMPLETE LIGHTING SYSTEM. <br />17. ALL OUTDOOR LIGHTING, LIGHTING EQUIPMENT AND CONTROLS SHALL BE <br />WEATHERPROOF (NEMA 3R) AND SUITEABLE FOR THE APPLICATION. <br />6 CONTRACTOR SHALL PROVIDE HANDHOLE ADJACENT TO NEW LIGHT <br />POLE TO ENSURE SEPARATION OF POWER AND LOW VOLTAGE CABLES IN <br />POLE. COORDINATE CONNECTION TO LIGHTING POLE IN THE FIELD AND <br />CONNECTION TO POLE MOUNTED SECURITY CAMERA IN THE FIELD. <br />COORDIANTE EXACT LOCATION OF HANDHOLE IN THE FIELD. <br />7 CONTRACTOR SHALL MOUNT FIXTURE ON SIDE OF TRELLIS. CONDUITS <br />SERVING SURFACE MOUNTED TRELLIS LIGHT FIXTURES SHALL BE <br />PAINTED TO MATCH COLUMNS. <br />8 CONTRACTOR SHALL PROVIDE JUNCTION BOX FOR NEW LIGHT FIXTURE <br />MOUNTED TO PICKET FENCE, TO ENSURE SEPARATION OF POWER AND <br />LOW VOLTAGE CABLES. COORDINATE CONNECTION TO LIGHTING <br />FIXTURE IN THE FIELD AND CONNECTION TO SECURITY CAMERA IN THE <br />FIELD. CONTRCTOR SHALL PROVIDE CUSTOM MOUNTING BRAKET FROM <br />WE-EF, MODEL NUMBER NSPR1507 FOR CONNECTION TO NEW LIGHT <br />FIXTURE. <br />9 NOT USED. <br />REV # DESCRIPTION DATE <br />#307 RFI 11.05.2025 <br />#335 RFI 12.30.2025 <br />#335 <br />RFI <br />#335 <br />RFI