Laserfiche WebLink
<br />PROJECT: <br />PROPOSED ANCHORAGE OF FIXED BOOTH SEATING <br />Job Ref. <br /> <br />STRUCTURAL CALCULATIONS: <br />ANCHORAGE ANALYSIS AND VERIFICATION <br />Sheet no./rev. <br /> <br />Calc. by <br /> <br />Date <br /> <br />Chk’d by <br /> <br />Date <br /> <br />App’d by <br /> <br />Date <br /> <br /> <br /> <br />Horizontal Load per anchor 42.6525 lbs <br />Vertical Load per anchor 5.17 lbs <br /> <br />Tension Load Capacity Check <br />SDS25200 <br />Thread Length 2 inch <br />Allowable Withdrawal Load 172 lbs/in <br /> 344 lbs <br />Safe in tension! <br />Shear Load Capacity Check <br />SDS25200 <br />Anchor bolt cross-sectional area, Ab 0.049087 in2 <br />Yield Strength, Fy 36 ksi <br /> <br />Nominal Shear Capacity, Vn 1060.288 lbs <br />Allowable Shear Capacity, Va 634.9027 <br />Safe in shear! <br />Overturning Check <br />height of fixed seats 36 in <br />Moment of Overturning, MOT=Fph 511.83 lbs <br />anchor bolt spacing 1 ft <br />Tension per back anchor, Tanchor 255.915 lbs <br /> <br />Interaction Check (Shear+Tension) 0.811119 < 1.0 <br />USE SDS25200 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />9/20