Armenian Cultural Center <br />SOLAR BEAM ELECTRIC INC <br />LOS ANGELES SOLAR PROS <br />5260 Pomona Blvd, Los Angeles, <br />CA 90022 <br />LIC#: 1033488, CLASS - C10, C46 <br />Grigor Manukov <br />5305 W McFadden Ave <br />Santa Ana, CA 92704 <br />Date: NOVEMBER 12, 2025 <br />Project Information <br />PV-1 <br />SHEET INDEX <br />PV-2.1 <br />PV-2.2 <br />PV-3 <br />PV-4 <br />From <br />Page 6 <br />Plot Plan <br />Stringing <br />Single line diagram <br />Array Layout <br />Signage <br />Additional Information <br />Data sheets, <br />Certifications... <br />DC SIZE <br />AC SIZE <br />50.050kW <br />42.542kW <br />SYSTEM SIZE <br />PV-1.1 <br />NOTES <br />1.NOTE: Building or Other Structure Supplied by a Photovoltaic System. Means shall be provided to Disconnect all ungrounded dc conductors <br />of a PV system from all other conductors in a building or other structure. (NFPA 70 Art. 690.13) <br />2. Note on plans. Each PV system disconnecting means shall be permanently marked to identify it as a PV system disconnect. (NFPA 70 Art. <br />690 13 (B)) <br />3. Note on plans. Means shall be provided to disconnect equipment, such as inverters, batteries, and charge controllers, from all ungrounded <br />conductors of all sources. If the equipment is energized from more than one source, the disconnecting means shall be grouped and identified. <br />(NFPA 70 Art.690.15) <br />4. Note on plans. Where dc PV source or dc PV output circuits from Building integrated systems or other PV systems are run inside a building <br />or structure, they shall be contained in metal raceways, Type MC metal-clad cable that complies with 250.118(10), or metal enclosures from <br />the point of penetration of the surface of the building or structure to the first readily NOTE:The following wiring methods and enclosures <br />that contain PV power source conductors shall be marked with the wording WARNING: PHOTOVOLTAIC POWER SOURCE by means of <br />permanently affixed labels or other approved permanent marking: (1) Exposed raceways, cable trays, and other wiring methods (2) Covers or <br />enclosures of pull boxes and junction boxes (3) Conduit bodies in which any of the available conduit openings are unused (NFPA 70 Art. <br />690.31(G) (3)) <br />5.NOTE:The labels or markings shall be visible after installation. The labels shall be reflective, and all letters shall be Capitalized and <br />shall be a minimum height of (3⁄ 8 in.) in White on a red background. PV power circuit labels shall appear on every section of the wiring <br />system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a <br />marking, shall not be more than (10 ft). Labels required by this section shall be suitable for the environment where they are installed. <br />(NFPA 70 Art. 690.31(G) (4)) <br />6. Note on plans. Any Structure or building with a PV power system that is not connected to a utility service source and is a stand-alone <br />system shall have a permanent plaque or directory installed on the exterior of the building or structure at a readily visible location <br />acceptable to the authority having jurisdiction. The plaque or directory shall indicate the location of system disconnecting means and that <br />the structure contains a stand-alone electrical power system. The marking shall be in accordance with 690.31(G). (NFPA 70 Sec.VI Art. <br />609.56 (A)) <br />7. Note on plans. Buildings or structures with both utility service and a PV system shall have a permanent plaque or directory providing the <br />location of the service disconnecting means and the PV location. The warning sign(s) or label(s) shall comply with 110.21(B). system <br />disconnecting means if not located at the same location. The warning sign(s) or label(s) shall comply with 110.21(B). NOTE: No piping,ducts or <br />equipment foreign to electrical equipment shall be permitted to be located within the dedicated space above the electrical <br />equipment.(110.26(f)) NOTE: FIRE CODE REFLECTS UPDATES FROM INTERVENING CODE CYCLE, EFFECTIVE 1 JULY 2018. FIRE SETBACKS AND <br />PATHWAYS COMPLY WITH IRC R324.6.1, R324.6.2, R324.7.2.6, AND IFC 1204.2.1.1, 1204.2.1.2, AND 1204.2.1.3 <br />8 NOTE: FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 3 1/2" HEIGHT, THEN UNDER THE EAVE TO PV <br />EQUIPMENT <br />9.NOTE:Roof access, pathways, and spacing requirements shall be provided in accordance with Sections 1204.2.1 through 1204.3.3. Pathways <br />shall be over areas capable of supporting fire fighters accessing the roof. Pathways shall be located in areas with minimal obstructions, <br />such as vent pipes, conduit or mechanical equipment <br />10.NOTE:Interior pathways. Interior pathways shall be provided between array sections to meet the following requirements NOTE:1204.3.3 <br />Smoke ventilation. The solar installation shall be designed to meet the following requirements: 1. Where non-gravity-operated smoke and heat <br />vents occur, a pathway not less than 4 feet (1219 mm) wide shall be provided bordering all sides. <br />Signed on: <br />Structural Only <br />03/26/2026