Laserfiche WebLink
MAXIMUM RATED AC OUTPUT CURRENT:119.79A <br />MAXIMUM OPERATING AC VOLTAGE:208V <br />PHOTOVOLTAIC POINT OF <br />INTERCONNECTION <br />WARNING: DUAL POWER SOURCE. <br />SECOND SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />Armenian Cultural Center <br />SOLAR BEAM ELECTRIC INC <br />LOS ANGELES SOLAR PROS <br />5260 Pomona Blvd, Los Angeles, <br />CA 90022 <br />LIC#: 1033488, CLASS - C10, C46 <br />Grigor Manukov <br />5305 W McFadden Ave <br />Santa Ana, CA 92704 <br />Date: NOVEMBER 12, 2025 <br />Project Information <br />PV-1 <br />SHEET INDEX <br />PV-2.1 <br />PV-2.2 <br />PV-3 <br />PV-4 <br />From <br />Page 6 <br />Plot Plan <br />Stringing <br />Single line diagram <br />Array Layout <br />Signage <br />Additional Information <br />Data sheets, <br />Certifications... <br />DC SIZE <br />AC SIZE <br />50.050kW <br />42.542kW <br />SYSTEM SIZE <br />PV-4 <br />CODE REQUIRED <br /> PV SIGNAGE <br />N <br />CAUTION <br />MULTIPLE SOURCES OF POWER <br />MAIN SERVICE PANEL <br />YOU ARE HERE <br />AC DISCONNECT <br />The marking shall comply with 110.21(B). <br />1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, <br />WEATHER RESISTANT AND SUITABLE FOR THE <br />ENVIRONMENT. <br />2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH <br />MINIMUM 38" LETTER HEIGHT, WHITE ON RED BACKGROUND. <br />3. MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED <br />ADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATION <br />CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER <br />IS OPERATED. <br />4. MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC <br />CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, <br />AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO <br />AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY <br />10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, <br />AND AT ALL DC COMBINER AND JUNCTION BOXES. <br />5. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE <br />ONLY APPROVED ADHESIVE. <br /> SIGNAGE LOCATIONS: <br />·MAIN SERVICE PANEL <br />·INDOOR/OUTDOOR SUB PANEL <br />NEC 705.12(B)(2)(3)(b) <br />SOURCE BREAKER <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br /> SIGNAGE LOCATIONS: <br />·MAIN SERVICE PANEL <br />·INDOOR/OUTDOOR SUB PANEL <br />·INDOOR OUTDOOR LOAD CENTER <br /> SIGNAGE LOCATIONS: <br />·SHALL BE LOCATED ON OR NO MORE <br />THAN 1M(3 FEET) FROM THE SWITCH <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH ON THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN ARRAY <br /> SIGNAGE LOCATIONS: <br />·SHALL BE LOCATED ON OR NO MORE <br />THAN 1 M (3 FT) <br />FROM THE SERVICE DISCONNECTING <br />MEANS TO WHICH <br />THE PV SYSTEMS ARE CONNECTED. <br />CAUTION:SOLAR CIRCUIT <br /> SIGNAGE LOCATIONS: <br />·EVERY 10" OF CONDUIT AND AT EVERY BEND <br />DO NOT ADD NEW LOADS <br /> SIGNAGE LOCATIONS: <br />·PV PANEL <br />·MAIN SERVICE PANEL WHEN-705.12(b)(2)(3)(c) <br /> SIGNAGE LOCATIONS: <br />·MAIN SERVICE PANEL <br />SOLAR COMBINER PANEL <br />ELECTRICAL EQUIPMENTS <br />ARE INDOOR. <br />IN ELECTRICAL ROOM <br />EMERGENCY PHONE NUMBER: <br />(844) 765-2702 <br />5305 W McFadden Ave 5305 W McFadden Ave