My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2126 S Doreen Way Unit # 2 - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Doreen Way
>
2126 S Doreen Way Unit# 2
>
2126 S Doreen Way Unit # 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2026 5:00:09 AM
Creation date
4/15/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101126104
Full Address
2126 S Doreen Way Unit# 2
Street Number
2126
Street Direction
S
Street Name
Doreen
Street Suffix
Way
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />Planning and Building Agency <br />RESIDENTIAL ROOM COOLING LOAD SUMMARY <br />Project Name <br />A.D.U. ADDITION <br />FOR PERMItT/J,5kJA <br />ROOM INFORMATION <br />DESIGN CONDITIONS <br />Room Name FLOOR PLAN <br />Outdoor Dry Bulb Temperature <br />91 OF <br />Floor Area 3 77. 00 ft' <br />Outdoor Wet Bulb Temperature <br />Master ID: <br />70 °F <br />Indoor Dry Bulb Temperature 78 OF <br />Outdoor Daily Range: <br />Date: <br />26 OF <br />Opaque Surfaces Orientation Area U-Factor <br />CLTD' <br />Btu/hr <br />R-30 Roof Cathedral (N) 377.0 X 0.0346 X <br />38.0 = <br />495 <br />R-15 Wall (lM 170.1 X 0.1028 X <br />14.0 = <br />245 <br />R-15 Wall (E) 138.1 X 0.1028 X <br />14.0 = <br />199 <br />R-15 Wall (N) 201.0 X 0.1028 X <br />4.0 = <br />83 <br />R-15 Wall (S) 172.0 X 0.1028 X <br />7.0 = <br />124 <br />X X <br />= <br />X X <br />= <br />X X <br />= <br />X X <br />= <br />Page Total <br />1,145 <br />Items shown with an asterisk (`) denote conduction through an interior surface to another room. <br />1. Cooling Load Temperature Difference (CLTD) <br />Shaded Unshaded <br />Fenestration Orientation Area GLF Area <br />GLF <br />Btu/hr <br />WINDOWS (E) 0.0 X 9.7 + 32.0 X 24.4 = <br />780 <br />WINDOWS (N) 0.0 X 9.7 + 3.0 X 9.7 = <br />29 <br />WINDOWS (S) 0.0 X 9.7 + 32.0 X 11.5 = <br />367 <br />X + <br />X = <br />X + <br />X = <br />X + <br />X = <br />X + <br />X = <br />X + <br />X = <br />X + <br />X = <br />Page Total <br />1.176 <br />Internal Gain <br />Btu/hr <br />Occupants 1 1 Occupants X 245 Btuh/occ. = <br />277 <br />Equipment 377 Floor Area X 0.50 w/sgft <br />= <br />643 <br />Infiltration: 1.075 X 0.65 X 16.24 X 13 = <br />148 <br />Air Sensible CFM ELA AT <br />TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM <br />3,389 <br />Latent Gain <br />Btu/hr <br />Occu 1 1 Occupants X 155 Btuhlocc. = <br />175 <br />ants <br />Infiltration: 4,822 X 0.65 X 16.24 X 0.00069 = <br />35 <br />Air Latent CFM ELA AW <br />TOTAL HOURLY LATENT HEAT GAIN FOR ROOM <br />211 <br />\ICE <br />
The URL can be used to link to this page
Your browser does not support the video tag.