My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1301 S Standard Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Standard Ave
>
1301 S Standard Ave
>
1301 S Standard Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2026 5:00:08 AM
Creation date
4/15/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101126065
Full Address
1301 S Standard Ave
Street Number
1301
Street Direction
S
Street Name
Standard
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
San Souci HOA Fence <br />JOB #:26027 <br />GOVERNING DESIGN CODES & SPECIFICATIONS: <br />2025 California Building Code <br />ASCE 7-22 – Minimum Design Loads for Buildings & Other Structures <br />AISC 360-22 – Steel Construction Manual <br />AISC 341-22 – Seismic Design Manual <br />ACI-318-19 – Building Code Requirements for Structural Concrete <br />NDS 2024 - National Design Specification for Wood Construction <br />DESIGN MATERIAL SPECIFICATIONS: <br />WOOD: <br />6x Members Use DF#1 <br />4x Members Use DF#1 <br />2x Members Use DF#2 <br />Studs Use Construction Grade <br />Glu-Lam Beams Use (24F-V4) <br />STEEL: <br />Structural Steel, ASTM A992, F y = 50 ksi <br />Structural Tubing, ASTM A500, Fy = 46 ksi <br />Pipes, ASTM A501, Fy = 36 ksi <br />Cold Formed, ASTM A-924/A-792 or A-570, Fy = 50 ksi <br />Nuts and Bolts, use ASTM-A307 U.N.O. <br />CONCRETE: <br />f'c = 2,500 psi <br />CMU BLOCK: <br />ASTM C-90 Grade N. <br />f'm = 1500 psi <br />Mortar Type S <br />Grout @28 Days f'c = 2000 psi <br />REINFORCING: <br />ASTM - 615 <br />#4 and Smaller Grade 40 <br />#5 and Larger Grade 60 <br />SOILS: <br />Design per CBC Table 1806.2 <br />Allowable Soil Bearing Pressure = 1.5 ksf <br />NOTE: <br />The intent of this design is to prevent structural failures, in the event of seismic activities or high-winds, but not to <br />prevent the damage of architectural finishes or systems. The calculations herein conform to the specifications of the <br />current California Building Code (CBC). Switchback Enterprises, Inc. provides no guarantees, expressed or implied, as <br />to the adequacy of the CBC provisions. <br />These calculations, specifications, details and drawings are instruments of service and are the property of <br />Switchback Enterprises, Inc. The information contained herein is for use on the specific project referenced above <br />and shall not be used otherwise without the written authorization of Switchback Enterprises, Inc.Page 2 of 8
The URL can be used to link to this page
Your browser does not support the video tag.