Laserfiche WebLink
E. DONIS <br />NO SCALE <br />HPS-C <br />APPROVAL: <br />PLEASE APPLY APPROVAL STAMP WITHIN PROVIDED AREA <br />HI <br />G <br />H <br /> <br />P <br />I <br />L <br />E <br />D <br /> <br />S <br />T <br />O <br />R <br />A <br />G <br />E <br /> <br />P <br />L <br />A <br />N <br />JOB NUMBER <br />DRAWN BY <br />DATE <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />L <br />O <br />C <br />A <br />T <br />I <br />O <br />N <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />T <br />I <br />T <br />L <br />E <br />: <br />OW <br />N <br />E <br />R <br />: <br />DA <br />T <br />E <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />AN <br />A <br />H <br />E <br />I <br />M <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br /> <br />9 <br />2 <br />8 <br />0 <br />7 <br />PR <br />E <br />M <br />I <br />E <br />R <br /> <br />F <br />I <br />R <br />E <br /> <br />C <br />O <br />N <br />S <br />U <br />L <br />T <br />I <br />N <br />G <br />, <br /> <br />L <br />L <br />C <br />(5 <br />6 <br />2 <br />) <br /> <br />8 <br />6 <br />5 <br />- <br />5 <br />1 <br />3 <br />4 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />W <br />W <br />W <br />. <br />P <br />R <br />E <br />M <br />I <br />E <br />R <br />- <br />F <br />I <br />R <br />E <br />. <br />N <br />E <br />T <br />em <br />a <br />i <br />l <br />: <br /> <br />g <br />r <br />e <br />g <br />@ <br />p <br />r <br />e <br />m <br />i <br />e <br />r <br />- <br />f <br />i <br />r <br />e <br />. <br />n <br />e <br />t <br />39 <br />1 <br />0 <br /> <br />E <br />. <br /> <br />C <br />O <br />R <br />O <br />N <br />A <br />D <br />O <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />. <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br />. <br /> <br />2 <br />0 <br />2 <br />REVIEWED BY <br />A-6584 <br />LO <br />G <br />O <br />M <br />A <br />R <br />K <br />60 <br />3 <br /> <br />W <br />. <br /> <br />D <br />Y <br />E <br />R <br /> <br />R <br />O <br />A <br />D <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />60 <br />1 <br /> <br />W <br /> <br />D <br />Y <br />E <br />R <br /> <br />L <br />L <br />C <br />43 <br />3 <br /> <br />N <br /> <br />C <br />A <br />M <br />D <br />E <br />N <br /> <br />D <br />R <br />I <br />V <br />E <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />8 <br />8 <br />8 <br />BE <br />V <br />E <br />R <br />L <br />Y <br /> <br />H <br />I <br />L <br />L <br />S <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />0 <br />2 <br />1 <br />0 <br />- <br />4 <br />4 <br />1 <br />2 <br />APN: 410-024-06 <br />APRIL 8, 2025 <br />B. MENDOZA <br />1 <br />05 <br />/ <br />1 <br />3 <br />/ <br />2 <br />0 <br />2 <br />5 <br />FI <br />R <br />E <br /> <br />D <br />E <br />P <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br /> <br />C <br />O <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />S <br />2 <br />06 <br />/ <br />0 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br />FI <br />R <br />E <br /> <br />D <br />E <br />P <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br /> <br />C <br />O <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />S <br />3 <br />12 <br />/ <br />1 <br />1 <br />/ <br />2 <br />0 <br />2 <br />5 <br />TE <br />N <br />A <br />N <br />T <br /> <br />R <br />E <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />SCOPE OF TENANT REVISION "3" <br />AFTER APPROVAL OF HIGH PILED STORAGE PLANS UNDER SR#25001806, LOGOMARK ELECTED TO <br />NARROW AISLES TO ACCOMMODATE ADDITIONAL STORAGE/PALLET POSITIONS. PLANS HAVE BEEN <br />UPDATED TO REFLECT THE ANTICIPATED RACK INSTALLATION AND CODE COMPLIANCE AS IT <br />RELATES TO HIGH PILED STORAGE. <br />PROJECT OVERVIEW <br />BUILDING INFORMATION: TYPE III-B CONSTRUCTION <br /> S-1, B OCCUPANCIES <br /> BUILT IN 1973 <br /> 1 STORY <br />BUILDING AREAS: 180,000 TOTAL FT² <br /> 58,614 FT² TENANT WAREHOUSE AREA <br /> 10,716 FT² OFFICE AREAS <br />EXISTING SPRINKLER DESIGN: CMSA K-16.8 @ 22 PSI (15 HEADS CALCULATED) <br /> 200° (UPRIGHT) SPRINKLER HEADS <br />BUILDING HEIGHT (RIDGE): 29'-4" ACTUAL <br />HIGH PILED STORAGE AREA: 52,712 FT² <br />STORAGE HEIGHT: 24'-2" FOR THE RACK STORAGE <br />SMOKE AND HEAT REMOVAL: 6 REQUIRED SMOKE VENTS <br /> 25 SMOKE VENTS PROVIDED <br />REFERENCE CODES <br />2022 CALIFORNIA FIRE CODE (CFC) <br />2022 NATIONAL FIRE PROTECTION ASSOCIATION 13 (NFPA) <br />2021 ORANGE COUNTY FIRE AUTHORITY GUIDELINE G-09 (OCFA) <br />SCOPE OF THIS SUBMITTAL <br />LOGOMARK IS AN EXISTING TENANT AT THIS FACILITY AND IS APPLYING FOR A HIGH PILED <br />COMBUSTIBLE STORAGE PERMIT. THE SCOPE OF WORK FOR THIS DOCUMENT IS TO SHOW CODE <br />COMPLIANCE WITH THE APPLICABLE CODES AND STANDARDS FOR HIGH PILED COMBUSTIBLE <br />STORAGE. <br />LOGOMARK IS APPROVED FOR HIGH PILED STORAGE IN THE NORTH PORTION OF THE BUILDING. <br />THEY ARE EXPANDING THEIR STORAGE INTO THE CENTER PORTION OF THE BUILDING. THE SCOPE <br />OF THIS SUBMITTAL IS TO ADDRESS THE NEW STORAGE AREA ONLY. <br />TENANT'S RESPONSIBILITIES <br />THE SCOPE OF THIS SUBMITTAL IS TO SHOW COMPLIANCE FOR HIGH PILED COMBUSTIBLE <br />STORAGE IN ACCORDANCE WITH CHAPTER 32 OF THE CALIFORNIA FIRE CODE. <br />BY WAY OF USING AND CONFORMING TO THIS DOCUMENT, AS APPROVED BY THE AUTHORITY <br />HAVING JURISDICTION, LOGOMARK AGREES TO CONFORM TO THE CONTENTS HEREIN. ANY <br />CHANGES OR MODIFICATIONS TO THESE APPROVED HIGH PILED COMBUSTIBLE STORAGE <br />CONFIGURATIONS NULLIFIES THE VALIDITY OF THIS DOCUMENT, AND A NEW HIGH PILED STORAGE <br />REPORT MUST BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION. ANY CHANGES AND/OR <br />LACK OF COMPLIANCE WITH THE GOVERNING CODES ARE OUTSIDE THE SCOPE OF THE REPORT <br />AND ARE THE SOLE RESPONSIBILITY OF LOGOMARK. <br />THIS REPORT IS THE PROPERTY OF PREMIER FIRE CONSULTING LLC AND WAS PREPARED <br />EXCLUSIVELY FOR THE USE BY LOGOMARK FOR THE HIGH PILE COMBUSTIBLE STORAGE <br />REQUIREMENTS AS DESCRIBED IN THIS REPORT. THE DESCRIPTION OF THE PRODUCTS TO BE <br />STORED AND THE STORAGE HEIGHTS ARE BASED ON INFORMATION PROVIDED BY LOGOMARK. <br />DISCREPANCIES BETWEEN THE INFORMATION PRESENTED HEREIN AND ACTUAL CONDITIONS <br />PRESENTED ON THE PLANS ARE THE SOLE RESPONSIBILITY OF LOGOMARK. FIELD VERIFICATION <br />OF ONSITE COMPLIANCE WITH THE CODE REQUIREMENTS AND PROVISIONS ADDRESSED HEREIN <br />IS OUTSIDE THE SCOPE OF THIS REPORT. THE RESULTS OF THIS REPORT HAVE BEEN REVIEWED <br />WITH LOGOMARK, AND LOGOMARK FULLY UNDERSTANDS THE FINDINGS OF THIS REPORT. <br />LOGOMARK HAS REVIEWED AND ACCEPTS THIS PLAN, AS SUBMITTED AND UNDERSTANDS THEIR <br />LIMITATIONS BASED ON THIS DESIGN. COPIES OF THIS REPORT RETAINED BY LOGOMARK SHALL <br />BE UTILIZED ONLY BY LOGOMARK FOR HIGH PILED STORAGE REQUIREMENTS AND THE 2022 CFC <br />CONDITIONS AND REQUIREMENTS ADDRESSED IN THIS REPORT. <br />THE REPORT SHALL NOT BE USED FOR THE PURPOSE OF CONSTRUCTION FOR THIS PROJECT OR <br />ANY OTHER PROJECT OR FOR ANY OTHER PURPOSE. <br />ANY AND ALL MODIFICATIONS TO THE BUILDING ARE THE SOLE RESPONSIBILITY OF THE <br />LOGOMARK. LOGOMARK SHALL OBTAIN A LICENSED CONTRACTOR, IF NECESSARY, TO PERFORM <br />SUCH WORK, ALONG WITH THE NECESSARY PLANS AND PERMITS FOR SUCH WORK. <br />IT IS THE RESPONSIBILITY OF LOGOMARK TO CALL THE FIRE DEPARTMENT FOR FINAL INSPECTION <br />WHEN ALL WORK IS COMPLETE. THE HIGH PILED STORAGE PERMIT WILL BE ISSUED AFTER FINAL <br />INSPECTION BY THE FIRE DEPARTMENT. <br />OUTSIDE THE SCOPE OF THIS PERMIT <br />THE FOLLOWING ITEMS ARE OUTSIDE THE SCOPE OF THESE HIGH PILE STORAGE PLANS, AND IF <br />REQUIRED BY THE AHJ, SHALL BE ADDRESSED UNDER A SEPARATE SUBMITTAL BY OTHERS: <br />APPROVED STORAGE LAYOUT PLAN PER CFC §3201.3.2, AMERICANS WITH DISABILITY ACT (ADA) <br />CODE ANALYSIS, EXIT SIGNAGE, EMERGENCY EGRESS LIGHTING, EXIT TRAVEL DISTANCE, FIRE <br />EXTINGUISHER PLACEMENT, REVIEW OF ANY HAZARDOUS MATERIALS, ANY STRUCTURAL ASPECTS <br />OF RACK DESIGN, BUILDING FIRE ALARM SYSTEM, FIRE SAFETY AND EVACUATION PLAN AND <br />BATTERY CHARGING STATIONS. <br />THERE SHALL BE NO STORAGE IN THE WAREHOUSE OF COMMODITIES EXCEEDING THE HAZARD <br />CLASS STIPULATED IN THE "COMMODITY DESCRIPTION OF HIGH PILED STORAGE" NOTE. THIS <br />INCLUDES, BUT IS NOT LIMITED TO: EXPANDED PLASTICS, HAZARDOUS MATERIALS, COOKING OILS, <br />LEVEL 2 OR 3 AEROSOLS, LITHIUM-ION BATTERIES, AND THOSE COMMODITIES OUTSIDE THE SCOPE <br />OF NFPA 13, TABLE A.20.4(A). <br />REQUIRED HPS PERMIT NOTE <br />AN OPERATIONAL PERMIT IS REQUIRED TO USE A BUILDING OR PORTION THEREOF WITH MORE <br />THAN 500 SQUARE FEET, INCLUDING AISLES, OF HIGH-PILED COMBUSTIBLE STORAGE. [CFC <br />§105.5.24] <br />APPROVED CONSTRUCTION DOCUMENTS <br />FOLLOWING APPROVAL OF THE CONSTRUCTION DOCUMENTS, A COPY OF THE APPROVED PLANS <br />SHALL BE MAINTAINED ON THE PREMISES IN AN APPROVED LOCATION. [CFC §3201.3.1] <br /> <br />APPROVED STORAGE LAYOUT <br />A FLOOR PLAN, OF LEGIBLE SIZE, SHALL BE PROVIDED, MOUNTED ON A WALL AND PROTECTED <br />FROM DAMAGE. THE FLOOR PLAN SHALL BE MOUNTED IN AN APPROVED LOCATION. [CFC §3201.3.2] <br /> <br />REQUIRED DEFERRED SUBMITTAL <br />AT MINIMUM, THE RACK INSTALLATION DOCUMENTS AND CALCULATIONS SHALL BE A REQUIRED <br />SEPARATE SUBMITTAL. PLANS SHALL BE SUBMITTED TO AND APPROVED BY THE APPROPRIATE <br />AUTHORITIES HAVING JURISDICTION PRIOR TO COMMENCING AND WORK. THE INSTALLING <br />CONTRACTOR SHALL OBTAIN A CITY BUSINESS LICENSE AND ALL REQUIRED PERMITS. <br />IF REQUIRED PERMITS FOR THE POWERED INDUSTRIAL TRUCK CHARGING STATIONS, SMOKE <br />VENTS, EMERGENCY EGRESS LIGHTING, ACCESS DOOR, AND SPRINKLER MODIFICATIONS ARE TO <br />BE APPLIED FOR AND OBTAINED BY THE CONTRACTORS AND WILL BE SEPARATE SUBMITTALS. <br />FIRE SAFETY AND EVACUATION PLAN <br />WHERE REQUIRED BY CFC SECTION 403, A FIRE SAFETY AND EVACUATION PLAN SHALL BE <br />SUBMITTED AT THE TIME OF PERMIT APPLICATION FOR REVIEW AND APPROVAL. A COPY OF THE <br />APPROVED FIRE SAFETY AND EVACUATION PLAN SHALL BE MAINTAINED ON THE PREMISES IN AN <br />APPROVED LOCATION. [CFC §3201.4] <br />MULTIPLE HIGH PILE STORAGE AREAS <br />WHERE A BUILDING CONTAINS MULTIPLE HIGH-PILED STORAGE AREAS, THE AGGREGATE OF ALL <br />HIGH-PILED STORAGE AREAS SHALL BE USED FOR THE APPLICATION OF TABLE 3206.2 <br /> [CFC §3206.3.2]: <br />·HIGH-PILED STORAGE AREAS SEPARATED BY FIRE BARRIERS WITH A MINIMUM <br />FIRE-RESISTANCE-RATING OF 1 HOUR CONSTRUCTED IN ACCORDANCE WITH SECTION 707 OF <br />THE CFC. <br />COMMODITY DESCRIPTION OF HIGH PILED STORAGE <br />THE PRODUCTS TO BE STORED ARE PRIMARILY PROMOTIONAL PRODUCTS COMPOSED PRIMARILY <br />OF PLASTIC, STEEL, ALUMINUM AND FABRICS. THESE ITEMS MAY BE PACKAGED IN CORRUGATED <br />CARTONS OR PLASTIC TOTES AND PLACED DIRECTLY ON A 36" BY 36" CONVENTIONAL WOODEN <br />PALLET AND STORED IN PALLET RACKS OR IN A PALLETIZED STORAGE CONFIGURATION. FOR THE <br />PALLET RACKS, THE PALLET IS PLACED ON WIRE MESH GRATING ON THE LOAD BEAM OF THE <br />PALLET RACK. NO SLATTED OR SOLID SHELVES WILL BE USED. <br />COMMODITIES ARE NOT PERMITTED TO BE STORED IN ANY OPEN-TOP CONTAINER PER NFPA 13, <br />§20.3.3. <br />THE PRODUCTS SHALL REMAIN WITHIN THE CONFINES OF THE PALLET WITH NO PRODUCT <br />OVERHANG. <br />THIS IS A HIGH HAZARD COMMODITY PER CFC §3203.6 & TABLE 3203.8. <br />·FIRE PROTECTION SHALL BE BASED ON EXPOSED, UNEXPANDED GROUP A PLASTICS PER <br />NFPA 13, SEE FIRE SPRINKLER REQUIREMENTS NOTE BELOW. <br />FIRE SPRINKLER REQUIREMENTS <br />THE REQUIRED FIRE SPRINKLER SYSTEM IS AN CONTROL MODE SPECIFIC SYSTEM WITH K-16.8, <br />200° UPRIGHT SPRINKLERS, DESIGNED TO DISCHARGE A MINIMUM END HEAD PRESSURE OF 22 PSI <br />FROM 15 OPERATING SPRINKLERS. <br />NFPA 13 - TABLE 22.5 ALLOWS FOR: <br />STORAGE TYPE: <br />SINGLE, DOUBLE AND MULTIPLE-ROW RACK STORAGE (NO OPEN-TOP CONTAINERS OR <br />SOLID SHELVES) <br />COMMODITY: <br />UP TO EXPOSED UNEXPANDED GROUP A PLASTICS <br />MAXIMUM BUILDING HEIGHT - 30'-0" (ACTUAL 29'-0") <br />PERMISSIBLE STORAGE HEIGHT - 25'-0" <br />ACTUAL STORAGE HEIGHT - 22'-6" <br />*DESIGN LIMITED TO SINGLE- AND DOUBLE-ROW RACKS WITH MINIMUM 8 FT AISLES. <br />THE CEILING DESIGN CRITERIA FOR SINGLE-, DOUBLE-, AND MULTIPLE-ROW RACKS SHALL BE <br />BASED ON OPEN-RACK CONFIGURATIONS AS DEFINED IN 3.3.147. [NFPA 13, §23.1.3] <br />OPEN RACK DEFINITION: <br />RACKS WITHOUT SHELVING OR WITH SHELVING IN RACKS THAT ARE FIXED IN PLACE WITH <br />SHELVES HAVING A SOLID SURFACE AND A SHELF AREA EQUAL TO OR LESS THAN 20 FT² OR <br />WITH SHELVES HAVING A WIRE MESH, SLATTED SURFACE, OR OTHER MATERIAL WITH OPENINGS <br />REPRESENTING AT LEAST 50 PERCENT OF THE SHELF AREA INCLUDING THE HORIZONTAL AREA <br />OF RACK MEMBERS AND WHERE THE FLUE SPACES ARE MAINTAINED. [NFPA 13, §3.3.147] <br />THE CLEARANCE BETWEEN THE DEFLECTOR AND THE TOP OF STORAGE SHALL BE 36 IN. OR <br />GREATER. [NFPA 13, §13.2.9] <br />TABLE 3206.2 REQUIREMENTS <br />ACTUAL STORAGE HEIGHT SHALL NOT EXCEED 24'-2" FOR THE RACK STORAGE. <br />THE AREA OF HIGH PILED STORAGE IS 52,712 FT². <br />CFC TABLE 3206.2, HIGH HAZARD COMMODITY. <br />2,501-300,000 SQUARE FEET OF HIGH PILED STORAGE: <br />AUTOMATIC FIRE EXTINGUISHING SYSTEM - REQUIRED (PROVIDED) <br />FIRE DETECTION SYSTEM - NOT REQUIRED (NOT PROVIDED) <br />FIRE DEPARTMENT ACCESS DOORS - REQUIRED (PROVIDED - EXISTING/NON-CONFORMING) <br />*A FIRE DEPARTMENT ACCESS ROAD IS ONLY PROVIDED ALONG THE EAST EXTERIOR WALL. <br />THE NORTH AND SOUTH WALL ARE DEMISING WALLS BETWEEN TENANT AND A RAIL SPUR <br />IS ALONG THE WEST WALL AND WAS NOT ORIGINALLY PERMITTED AS A REQUIRED FIRE <br />DEPARTMENT ACCESS ROAD. WHERE POSSIBLE, ADEQUATE FIRE DEPARTMENT ACCESS IS <br />PROVIDED. <br />SMOKE AND HEAT REMOVAL - NOT REQUIRED PER FOOTNOTE H (PROVIDED) <br /> <br />FOOTNOTE H - NOT REQUIRED WHEN STORAGE AREAS WITH AN EXIT ACCESS TRAVEL DISTANCE <br />OF 250 FEET OR LESS ARE PROTECTED BY EITHER EARLY SUPPRESSION FAST RESPONSE (ESFR) <br />SPRINKLER SYSTEMS OR CONTROL MODE SPECIAL APPLICATION SPRINKLERS WITH A RESPONSE <br />TIME INDEX OF 50 (M * S) 1/2 OR LESS THAT ARE LISTED TO CONTROL A FIRE IN THE STORED <br />COMMODITIES WITH 12 OR FEWER SPRINKLERS, INSTALLED IN ACCORDANCE WITH SECTION <br />903.3.1.1. <br />GENERAL NOTES <br />REQUIRED FLUE SPACE NOTE <br />REQUIRED FLUE SPACES SHALL BE MAINTAINED IN ACCORDANCE WITH THE CFC TABLE 3208.3. <br />FOR STORAGE ≤ 25 FEET: <br />·SINGLE-ROW RACKS PROVIDE A 3" TRANSVERSE FLUE SPACE. <br />·DOUBLE-ROW RACKS (OPTION 2) PROVIDE A 3" TRANSVERSE FLUE SPACE AND A 6" <br />LONGITUDINAL FLUE SPACE. <br />THE TRANSVERSE FLUE SPACES WILL BE MAINTAINED BY THE USE OF FLUE-KEEPER DEVICES AND <br />FLUE SPACE LABELS AS INDICATED ON SHEET HPS-3. <br />THE LONGITUDINAL FLUE SPACES WILL BE MAINTAINED BY THE USE OF A PALLET STOP AS <br />INDICATED ON SHEET HPS-3 IN DOUBLE-ROW RACKS THAT UTILIZE A 12" ROW SPACER. <br />IN DOUBLE-ROW RACKS THAT UTILIZE A 24" ROW SPACER, THE LONGITUDINAL FLUE SPACE WILL BE <br />MAINTAINED BY THE FOLLOWING DESIGN APPROACH. THE UPRIGHTS ARE 36" IN DEPTH AND ARE <br />SEPARATED BY A 24" ROW SPACER. LOGOMARK ONLY USES TYPICAL 36" BY 36" (DEPTH X WIDTH) <br />WOODEN PALLETS. WHEN THE PALLET IS LOADED ON THE 36" DEEP UPRIGHT, FLUSH WITH THE <br />FRONT LOAD BEAM, THE PALLET WILL NOT OVERHANG. THERE WILL STILL BE A CLEAR 24" <br />LONGITUDINAL FLUE SPACE. THE CFC ONLY REQUIRES A 6" FLUE, THEREFORE, NO PALLET STOPS <br />WILL BE INSTALLED FOR THE 24" ROW SPACERS. PLEASE SEE HPS-2 FOR DOUBLE-ROW RACKS <br />WITH 24 ROW SPACERS. <br /> <br />PALLET STOPS <br />RACK STORAGE AREAS PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED <br />WITH FLUE SPACES IN ACCORDANCE WITH TABLE 3208.3. REQUIRED FLUE SPACES SHALL BE <br />MAINTAINED. [CFC §3208.3] <br />FLUE SPACES REQUIRED BY CFC TABLE 3208.3 ABOVE THE FIRST TIER OF STORAGE IN SINGLE-, <br />DOUBLE- OR MULTIPLE-ROW RACKS STORAGE INSTALLATIONS SHALL BE EQUIPPED WITH <br />APPROVED PROTECTION DEVICES. SUCH DEVICES SHALL NOT BE REMOVED OR MODIFIED. [CFC <br />§3208.3.1] <br />THE ORANGE COUNTY FIRE AUTHORITY REQUIRES PALLET STOPS FOR MAINTENANCE OF THE <br />REQUIRED LONGITUDINAL FLUE SPACES AND FLUEKEEPERS AND FLUE SPACE LABELING FOR <br />MAINTENANCE OF THE TRANSVERSE FLUE SPACES WHERE REQUIRED BY TABLE 3208.3. <br />NO SOLID SHELVING NOTE <br />THERE SHALL BE NO SOLID SHELVING IN THE HIGH PILE STORAGE AREA THAT EXCEEDS 20 SQUARE <br />FEET, MEASURED BETWEEN APPROVED FLUE SPACES AT ALL FOUR EDGES OF THE SHELF. [CFC <br />§3208.2.2] <br />EXISTING SMOKE VENT REQUIREMENTS <br />WHERE VENTS ARE INSTALLED IN AREAS PROVIDED WITH AUTOMATIC FIRE SPRINKLERS AND THE <br />VENTS OPERATE BY FUSIBLE LINK, THE FUSIBLE LINK SHALL HAVE A TEMPERATURE RATING OF <br />360° F. [CFC §910.3.5] <br />SMOKE AND HEAT VENTS SHALL BE MAINTAINED IN AN OPERATIVE CONDITION. INSPECTION, <br />TESTING AND MAINTENANCE SHALL BE IN ACCORDANCE WITH NFPA 204 EXCEPT AS FOLLOWS: <br />[CFC 910.5.1] <br />1.MECHANICALLY OPERATED SMOKE AND HEAT VENTS SHALL BE INSPECTED ANNUALLY <br />AND OPERATIONALLY TESTED NOT LESS THAN EVERY 5 YEARS. <br />3. FUSED, DAMAGED OR PAINTED FUSIBLE LINKS SHALL BE REPLACED. <br />OWNER / TENANT TO VERIFY THE SMOKE VENTS ARE MAINTAINED IN ACCORDANCE WITH THE <br />ABOVE REQUIREMENTS. <br />BUILDING ACCESS NOTE <br />FIRE APPARATUS ACCESS ROADS IN ACCORDANCE WITH SECTION 503 SHALL BE PROVIDED WITHIN <br />150 FEET OF ALL PORTIONS OF THE EXTERIOR WALLS OF BUILDINGS USED FOR HIGH-PILED <br />STORAGE. [CFC §3206.6] <br />EXCEPTION: WHERE FIRE APPARATUS ACCESS ROADS CANNOT BE INSTALLED BECAUSE OF <br />TOPOGRAPHY, RAILWAYS, WATERWAYS, NONNEGOTIABLE GRADES OR OTHER SIMILAR <br />CONDITIONS, THE FIRE CODE OFFICIAL IS AUTHORIZED TO REQUIRE ADDITIONAL FIRE <br />PROTECTION. <br />WHERE FIRE DEPARTMENT ACCESS DOORS ARE REQUIRED BY TABLE 3206.2, FIRE DEPARTMENT <br />ACCESS DOORS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 3206.7.1 THROUGH 3206.7.8. <br />[CFC §3206.7] <br />FIRE DEPARTMENT ACCESS DOORS ARE NOT REQUIRED IN AN EXTERIOR WALL THAT DOES NOT <br />FACE A FIRE APPARATUS ACCESS ROAD PROVIDED THAT ALL OF THE FOLLOWING CONDITIONS <br />OCCUR: [CFC §3206.7.1] <br />·THE OPPOSITE WALL FACES A FIRE APPARATUS ACCESS ROAD. <br />·THE OPPOSITE EXTERIOR WALL IS PROVIDED WITH FIRE DEPARTMENT ACCESS DOORS. <br />·THE ENTIRE INTERIOR SURFACE OF THE EXTERIOR WALL IS LESS THAN 150 FEET AWAY <br />FROM A FIRE DEPARTMENT ACCESS DOOR. <br />·THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN <br />ACCORDANCE WITH SECTION 903.3.1.1. <br />WHERE EXTERIOR WALLS SURROUNDING HIGH-PILED STORAGE AREAS FACE FIRE APPARATUS <br />ACCESS ROADS, SUCH WALLS SHALL BE PROVIDED WITH FIRE DEPARTMENT ACCESS DOORS.[CFC <br />§3206.7.2] <br />FIRE DEPARTMENT ACCESS DOORS SHALL BE ACCESSIBLE WITHOUT THE USE OF A LADDER. [CFC <br />§3206.7.3] <br />FIRE DEPARTMENT ACCESS DOORS SHALL BE LABELED ON THE EXTERIOR SIDE WITH THE <br />FOLLOWING SIGN OR OTHER APPROVED SIGN: <br />FIRE DEPARTMENT ACCESS DOOR <br />DO NOT BLOCK <br />THE LETTERING SHALL BE IN A CONTRASTING COLOR TO THE BACKGROUND. LETTERS SHALL HAVE <br />A MINIMUM HEIGHT OF 2 INCHES WITH A MINIMUM STROKE OF 3/8 INCH. [CFC §3206.7.4] <br />THE REQUIRED FIRE DEPARTMENT ACCESS DOORS SHALL BE DISTRIBUTED SUCH THAT THE LINEAL <br />DISTANCE BETWEEN ADJACENT FIRE DEPARTMENT ACCESS DOORS DOES NOT EXCEED 125 FEET <br />MEASURED CENTER TO CENTER. [CFC §3206.7.5] <br />EXCEPTION: THE LINEAR DISTANCE BETWEEN ADJACENT ACCESS DOORS SHALL NOT EXCEED <br />200 FEET IN EXISTING BUILDINGS WHERE CHANGE IN OCCUPANCY IS NOT PROPOSED. <br />FIRE DEPARTMENT ACCESS DOORS SHALL BE NOT LESS THAN 3 FEET IN WIDTH AND 6 FEET 8 <br />INCHES IN HEIGHT. ROLL-UP DOORS SHALL NOT BE CONSIDERED FIRE DEPARTMENT ACCESS <br />DOORS UNLESS APPROVED. [CFC §3206.7.6] <br />LOCKING DEVICES ON FIRE DEPARTMENT ACCESS DOORS SHALL BE APPROVED. [CFC §3206.7.7] <br />WHERE FIRE DEPARTMENT ACCESS DOORS ARE REQUIRED, A KEY BOX SHALL BE INSTALLED IN <br />ACCORDANCE WITH CFC §506.1. THE KEY BOX SHALL CONTAIN KEYS OR DEVICES TO ALLOW FOR <br />ENTRY THROUGH THE FIRE DEPARTMENT ACCESS DOORS. [CFC §3206.7.8] <br />AISLE REQUIREMENTS <br />AISLES IN SPRINKLERED BUILDINGS SHALL NOT BE LESS THAN 44 INCHES WIDE. [CFC §3206.10.1.1] <br />THE REQUIRED AISLE WIDTH SHALL EXTEND FROM FLOOR TO CEILING. RACK STRUCTURAL <br />SUPPORTS AND CATWALKS ARE ALLOWED TO CROSS AISLES AT A MINIMUM HEIGHT OF 6 FEET 8 <br />INCHES ABOVE THE FINISHED FLOOR LEVEL, PROVIDED THAT SUCH SUPPORTS DO NOT INTERFERE <br />WITH FIRE DEPARTMENT HOSE STREAM TRAJECTORY. [CFC §3206.10.2] <br />DEAD-END AISLES SHALL NOT EXCEED 50 FEET IN LENGTH IN S-1 OCCUPANCIES. [CFC §3206.10.3] <br />5 YEAR CERTIFICATION NOTE <br />THE LAST 5-YEAR CERTIFICATION TEST WAS CONDUCTED IN MAR, 2022. <br />MONITORING NOTE <br />VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS, PUMPS, TANKS, <br />WATER LEVELS AND TEMPERATURES, CRITICAL AIR PRESSURES AND WATERFLOW SWITCHES ON <br />ALL SPRINKLER SYSTEMS SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM <br />CONTROL UNIT. [CFC §903.4] <br />FIRE PROTECTION VALVE ACCESSIBILITY <br />SYSTEM VALVES AND GAUGES SHALL BE ACCESSIBLE FOR OPERATION, INSPECTION, TESTS AND <br />MAINTENANCE. [NFPA 13, §16.1.1] <br />HAZARDOUS MATERIALS NOTE <br />THERE SHALL BE NO HAZARDOUS MATERIAL STORAGE ALLOWED WITHOUT APPROVAL BY THE <br />ORANGE COUNTY FIRE AUTHORITY. <br />THIS REVIEW DOES NOT INCLUDE ANALYSIS OF ANY HAZARDOUS MATERIALS TO BE PRESENT. IF <br />THERE ARE TO BE ANY HAZARDOUS MATERIALS, A CHEMICAL CLASSIFICATION REVIEW AND <br />ANALYSIS SHALL BE PRESENTED TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL UNDER A <br />SEPARATE SUBMITTAL. IT IS PREMIER FIRE CONSULTING LLC'S UNDERSTANDING THAT ANY HAZMAT <br />THAT MAY EXIST WILL BE LIMITED TO JANITORIAL AND MAINTENANCE PURPOSE AND WILL NOT <br />EXCEED THE MAQ'S FOR A SINGLE CONTROL AREA. <br />PORTABLE FIRE EXTINGUISHER NOTE <br />FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH THE CFC §3206.11 AND SECTION <br />906. FIRE EXTINGUISHERS SHALL BE LOCATED THROUGHOUT THE BUILDING SO THAT NO POINT IN <br />THE BUILDING IS MORE THAN 75 FEET TRAVEL DISTANCE TO A FIRE EXTINGUISHER. FIRE <br />EXTINGUISHERS SHALL NOT BE OBSTRUCTED OR OBSCURED FROM VIEW. WHEN THE VISUAL <br />OBSTRUCTIONS CANNOT BE AVOIDED, MEANS SHALL BE PROVIDED TO INDICATE THE LOCATION OF <br />FIRE EXTINGUISHERS. <br />SHALL BE AS FOLLOWS: <br />1.PROVIDE A MINIMUM RATING OF 4-A FOR EXTRA HAZARD OCCUPANCIES. <br />2.MAXIMUM FLOOR AREA PER UNIT OF "A" IS 1,000 FT² . <br />3.MAXIMUM FLOOR AREA FOR INDIVIDUAL FIRE EXTINGUISHERS IS 11,250 FT². <br />4.MAXIMUM TRAVEL DISTANCE TO AN EXTINGUISHER IS 75 FEET. <br />OWNER / TENANT TO VERIFY THE EXISTING QUANTITY AND TYPE WITHIN THE WAREHOUSE. IF <br />ADDITIONAL FIRE EXTINGUISHERS ARE REQUIRED, IT IS THE RESPONSIBILITY OF THE OWNER / <br />TENANT TO PROVIDE. IF PLANS ARE REQUIRED BY THE FIRE DEPARTMENT FOR FIRE EXTINGUISHER <br />LOCATIONS, THE PLANS SHALL BE UNDER A SEPARATE SUBMITTAL. <br />BATTERY CHARGING AREAS SHALL BE PROVIDED WITH A FIRE EXTINGUISHER COMPLYING WITH <br />SECTION 906 HAVING A MINIMUM 4-A:20-B:C RATING WITHIN 20 FEET OF THE BATTERY CHARGER <br />PER CFC §309.5. <br />INTERNALLY ILLUMINATED EXIT SIGN NOTE <br />ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMINESCENT EXIT SIGNS SHALL BE LISTED <br />AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS AND SECTION 1203. EXIT SIGNS SHALL BE ILLUMINATED AT ALL <br />TIMES. [CFC §1013.5] <br /> <br />HOUSEKEEPING AND MAINTENANCE <br />THE APPROVED STORAGE LAYOUT SHALL BE VERIFIED AND EVALUATED ANNUALLY IN <br />ACCORDANCE WITH SECTION 3201.3.2. MODIFICATIONS OR CHANGES TO THE PROVISIONS OF THE <br />APPROVED STORAGE LAYOUT SHALL NOT BE MADE WITHOUT PRIOR APPROVAL OF THE FIRE CODE <br />OFFICIAL. [CFC §3205.1] <br />THE STRUCTURAL INTEGRITY OF RACKS SHALL BE MAINTAINED. [CFC §3205.2] <br />CLEARANCE FROM IGNITION SOURCES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 305. <br />[CFC §3205.3] <br />SMOKING SHALL BE PROHIBITED. APPROVED “NO SMOKING” SIGNS SHALL BE CONSPICUOUSLY <br />POSTED IN ACCORDANCE WITH SECTION 310. [CFC §3205.4] <br />THE FIRE CODE OFFICIAL IS AUTHORIZED TO ORDER THE POSTING OF "NO SMOKING" SIGNS OR <br />THE INTERNATIONAL SYMBOL FOR NO SMOKING IN A CONSPICUOUS LOCATION IN EACH <br />STRUCTURE OR LOCATION IN WHICH SMOKING IS PROHIBITED. THE CONTENT, SIZE, LETTERING, <br />SIZE COLOR AND LOCATION OF REQUIRED "NO SMOKING" SIGNS SHALL BE APPROVED. [CFC <br />§310.3] <br />EXCEPTION: "NO SMOKING" SIGNS ARE NOT REQUIRED IN INTERIOR LOCATIONS OF THE FACILITY <br />WHERE SIGNS ARE DISPLAYED AT ALL MAJOR ENTRANCES INTO THE FACILITY <br />WHEN RESTOCKING IS NOT BEING CONDUCTED, AISLES SHALL BE KEPT CLEAR OF STORAGE, <br />WASTE MATERIAL AND DEBRIS. FIRE DEPARTMENT ACCESS DOORS, AISLES AND EXIT DOORS <br />SHALL NOT BE OBSTRUCTED. DURING RESTOCKING OPERATIONS USING MANUAL STOCKING <br />METHODS, A MINIMUM UNOBSTRUCTED AISLE WIDTH OF 24 INCHES SHALL BE MAINTAINED IN <br />48-INCH OR SMALLER AISLES, AND A MINIMUM UNOBSTRUCTED AISLE WIDTH OF ONE-HALF OF THE <br />REQUIRED AISLE WIDTH SHALL BE MAINTAINED IN AISLES GREATER THAN 48 INCHES. DURING <br />MECHANICAL STOCKING OPERATIONS, A MINIMUM UNOBSTRUCTED AISLE WIDTH OF 44 INCHES <br />SHALL BE MAINTAINED IN ACCORDANCE WITH SECTION 3206.10. [CFC §3205.5] <br />AS REQUIRED BY THE FIRE CODE OFFICIAL, A VISUAL METHOD OF INDICATING THE MAXIMUM <br />ALLOWABLE STORAGE HEIGHT SHALL BE PROVIDED. [CFC §3205.7] SEE HPS-2. <br />ARRAYS SHALL COMPLY WITH SECTION 3207.4 [CFC §3205.8] <br />FLUE SPACES SHALL COMPLY WITH SECTION 3208.3 [CFC §3205.9] <br /> <br />ORANGE COUNTY FIRE DEPARTMENT NOTES <br />·FIRE DEPARTMENT INSPECTION REQUIRED. SCHEDULE 2 DAYS IN ADVANCE, @ (714) 573-6150. <br />·A CFC PERMIT IS REQUIRED FOR HPS AND WILL BE ISSUED BY AN OCFA INSPECTOR. <br />·LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WITH CFC <br />906.2 AND CHAPTER 3, TITLE 19 CCR AND PLACEMENT IS SUBJECT TO THE APPROVAL OF THE FIRE <br />INSPECTOR. <br />·STORAGE, DISPENSING OR USE OF ANY FLAMMABLE/COMBUSTIBLE MATERIALS AND OTHER <br />HAZARDOUS MATERIALS SHALL COMPLY WITH CFC REGULATIONS. <br />·EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY <br />SPECIAL KNOWLEDGE OR EFFORT. <br />·MODIFICATION TO FIRE SPRINKLER AND ALARM SYSTEMS SHALL COMPLY WITH 2022 NFPA 13 AND <br />72. A SEPARATE PLAN SUBMITTAL IS REQUIRED. <br />·FIRE SPRINKLER SYSTEMS AND ALL CONTROL VALVES SHALL BE MONITORED BY A U.L. LISTED <br />CENTRAL ALARM STATION OR BE SUPERVISED PER 2022 CFC CHAPTER 9. A SEPARATE PLAN <br />SUBMITTAL IS REQUIRED FOR THE INSTALLATION OF THE MONITORING SYSTEM. <br />·FIRE APPARATUS ACCESS ROADS SHALL BE UNOBSTRUCTED. ACCESS GATES SHALL BE <br />APPROVED PRIOR TO INSTALLATION AND SHALL BE IN COMPLIANCE WITH CFC 504 AND OCFA <br />GUIDELINES. <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />ORANGE COUNTY FIRE AUTHORITY <br />Reviewed by Planning & Development <br />Service Request Expires After 6 Months of Inactivity <br />Approval subject to field inspection and required test, <br />notations hereon, conditions in correspondence and <br />conformance with applicable regulations. The stamping of <br />these plans shall not be held to permit or approve the <br />violation of any law. <br />OCFA SR #: <br />Fee Codes: <br />Plan Type: <br />By: <br />ONLY STAMPED SHEETS REVIEWED BY <br />ORANGE COUNTY FIRE AUTHORITY <br />Call at least 72 hours in advance to schedule <br />inspections: (714) 573­6150 <br />Notes: <br />25006278 <br /> <br />PR330 <br />High­Piled Combustible Storage <br />Date: 01/05/2026 <br />RichSwanson