Laserfiche WebLink
TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO <br />THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT <br />BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. <br />©2024 IMEG CONSULTANTS CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />222 S. HARBOR BOULEVARD <br />SUITE 800 <br />ANAHEIM, CA 92805 <br />P: 714.490.5555 F: 714.490.5560 <br />The FUTURE. Built Smarter www.imegcorp.com <br />PROJECT #24007312.00 <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" <br />0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev: Section: <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />ed <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />ed <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />CAP029271 <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />PROJECT #24007312.00 <br />Revisions <br />By Appr. <br />KAISER HARBOR MACARTHUR MOB <br />EXTERIOR SIGNAGE <br />KAISER PERMANENTE <br />HARBOR MACARTHUR MOB <br />1/ <br />2 <br />3 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />2 <br />: <br />4 <br />5 <br />: <br />5 <br />3 <br /> <br />P <br />M <br />01/23/2026 <br />MG <br />CL <br />ES004 <br />ELECTRICAL SPECIFICATIONS <br />3401 South Harbor Boulevard, <br />Santa Ana, CA 92704 <br />10 <br />0 <br />% <br /> <br />C <br />D <br /> <br />S <br />E <br />T <br />2441 <br />ELECTRICAL SPECIFICATIONS TABLE OF CONTENT <br />• SECTION 26 05 53 -ELECTRICAL IDENTIFICATION <br />SECTION 26 05 53 -ELECTRICAL IDENTIFICATION <br />PART 1 -GENERAL <br />1.1 SECTION INCLUDES <br />A.ADHESIVE MARKINGS AND FIELD LABELS <br />B.NAMEPLATES AND SIGNS <br />C.PRODUCT COLORS <br />1.2 REFERENCES <br />A.NFPA 70E -NATIONAL ELECTRICAL SAFETY CODE <br />B.CEC CALIFORNIA ELECTRICAL CODE <br />C.ANSI A13.1 -STANDARD FOR PIPE IDENTIFICATION <br />D.ANSI Z535.4 -STANDARD FOR PRODUCT SAFETY SIGNS AND LABELS <br />1.3 QUALITY ASSURANCE <br />A.ELECTRICAL IDENTIFICATION PRODUCTS SHALL BE SUITABLE FOR THE ENVIRONMENT <br />INSTALLED. IDENTIFICATION LABELS DAMAGED BY THE ENVIRONMENT DUE TO <br />ULTRAVIOLET LIGHT FADING, DAMP OR WET CONDITIONS, PHYSICAL DAMAGE, <br />CORROSION, OR OTHER CONDITIONS SHALL BE REPLACED WITH LABELS SUITABLE FOR <br />THE ENVIRONMENT. <br />PART 2 -PRODUCTS <br />2.1 ADHESIVE MARKINGS AND FIELD LABELS <br />A.ADHESIVE MARKING LABELS FOR RACEWAY: PRE-PRINTED, FLEXIBLE, SELF-ADHESIVE <br />VINYL LABELS WITH LEGEND INDICATING VOLTAGE AND SERVICE (EMERGENCY, LIGHTING, <br />POWER, HVAC, COMMUNICATIONS, CONTROL, FIRE). <br />1.LABEL SIZE AS FOLLOWS: <br />a.RACEWAYS: KROY OR BROTHER LABELS 1-INCH (25MM) HIGH BY 12-INCHES <br />(305MM) LONG (MINIMUM). <br />2.COLOR: AS SPECIFIED FOR VARIOUS SYSTEMS. <br />B.COLORED ADHESIVE MARKING TAPE FOR BANDING RACEWAYS, WIRES, AND CABLES: <br />SELF-ADHESIVE VINYL TAPE NOT LESS THAN 3 MILS THICK BY 1 INCH (25MM) TO 2 INCHES <br />(50MM) IN WIDTH. <br />C.WIRE/CABLE DESIGNATION TAPE MARKERS: VINYL OR VINYL-CLOTH, SELF-ADHESIVE, <br />WRAPAROUND, CABLE/CONDUCTOR MARKERS WITH PREPRINTED NUMBERS AND LETTER. <br />2.2 PRODUCT COLORS <br />A.NAMEPLATES AND SIGNS: <br />1.NORMAL POWER: BLACK LETTERS ON WHITE FACE <br />2.CONTROL LABELS: BLACK LETTERS ON WHITE FACE <br />B.RACEWAYS AND CONDUIT: <br />1.PROVIDE COLOR CODED CONDUIT AS INDICATED BELOW. CONDUIT SHALL BE <br />COLORED BY THE MANUFACTURER: <br />a.NORMAL POWER AND GENERAL DISTRIBUTION: SILVER <br />b.EMERGENCY POWER DISTRIBUTION SYSTEM: <br />1)ALL EMERGENCY: ORANGE <br />c.FIRE ALARM SYSTEM: RED <br />d.LOW VOLTAGE AND TELEPHONE: PURPLE <br />C.BOX COVERS: <br />1.BOX COVERS SHALL BE PAINTED TO CORRESPOND WITH SYSTEM TYPE AS FOLLOWS: <br />a.NORMAL POWER AND GENERAL: SILVER <br />b.EMERGENCY POWER AND DISTRIBUTION: <br />1)ALL EMERGENCY: ORANGE <br />c.FIRE ALARM SYSTEM: RED <br />d.GROUND: GREEN <br />e.LOW VOLTAGE AND TELEPHONE: PURPLE <br />2.BOX COVER COLORS SHALL MATCH CONDUIT COLORS LISTED ABOVE. <br />D.CONDUCTOR COLOR IDENTIFICATION: REFER TO PART 3 FOR ADDITIONAL INFORMATION. <br />PART 3 -EXECUTION <br />3.1 INSTALLATION <br />A.LETTERING AND GRAPHICS: COORDINATE NAMES, ABBREVIATIONS, COLORS, AND OTHER <br />DESIGNATIONS USED IN ELECTRICAL IDENTIFICATION WORK WITH CORRESPONDING <br />DESIGNATIONS SPECIFIED OR INDICATED. INSTALL NUMBERS, LETTERING, AND COLORS <br />AS APPROVED IN SUBMITTALS AND AS REQUIRED BY CODE. <br />B.EXPOSED CEILINGS AND FINISHED SPACES: THE PROJECT INCLUDES EXPOSED CEILINGS <br />IN FINISHED SPACES. THE INSTALLATION OF COLORED RACEWAYS AND LABELING MAY <br />NOT BE AESTHETICALLY DESIRABLE IN FINISHED SPACES. THE CONTRACTOR SHALL <br />COORDINATE IDENTIFICATION REQUIREMENTS IN EXPOSED CEILINGS OF FINISHED <br />SPACES WITH THE A/E PRIOR TO INSTALLATION AND ORDERING OF MATERIALS. <br />C.INSTALL IDENTIFICATION DEVICES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN <br />INSTRUCTION AND REQUIREMENTS OF ELECTRICAL CODE. <br />D.SEQUENCE OF WORK: WHERE IDENTIFICATION IS TO BE APPLIED TO SURFACES THAT <br />REQUIRE FINISH, INSTALL IDENTIFICATION AFTER COMPLETION OF FINISH WORK. ALL <br />MOUNTING SURFACES SHALL BE CLEANED AND DEGREASED PRIOR TO IDENTIFICATION <br />INSTALLATION. <br />E.CIRCUIT IDENTIFICATION: TAG OR LABEL CONDUCTORS AS FOLLOWS: <br />1.MULTIPLE POWER OR LIGHTING CIRCUITS IN SAME ENCLOSURE: WHERE MULTIPLE <br />BRANCH CIRCUITS ARE TERMINATED OR SPLICED IN A BOX OR ENCLOSURE, LABEL <br />EACH CONDUCTOR WITH SOURCE AND CIRCUIT NUMBER. <br />2.MULTIPLE CONTROL WIRING AND COMMUNICATION/SIGNAL CIRCUITS IN SAME <br />ENCLOSURE: FOR CONTROL AND COMMUNICATIONS/SIGNAL WIRING, USE WIRE/CABLE <br />MARKING TAPE AT TERMINATIONS IN WIRING BOXES, TROUGHS, AND CONTROL <br />CABINETS. USE CONSISTENT LETTER/NUMBER CONDUCTOR DESIGNATIONS <br />THROUGHOUT ON WIRE/CABLE MARKING TAPE. <br />3.MATCH IDENTIFICATION MARKINGS WITH DESIGNATIONS USED IN PANELBOARDS SHOP <br />DRAWINGS, CONTRACT DOCUMENTS, AND SIMILAR PREVIOUSLY ESTABLISHED <br />IDENTIFICATION SCHEMES FOR THE FACILITY'S ELECTRICAL INSTALLATIONS. <br />F.INSTALL LABELS PARALLEL TO EQUIPMENT LINES AT LOCATIONS AS REQUIRED AND AT <br />LOCATIONS FOR BEST CONVENIENCE OF VIEWING WITHOUT INTERFERENCE WITH <br />OPERATION AND MAINTENANCE OF EQUIPMENT. <br />3.2 FEEDER AND BRANCH CIRCUIT DIRECTORIES <br />A.PRODUCT: <br />1.ADHESIVE LABELS AND FIELD MARKINGS <br />2.NAMEPLATES AND SIGNS <br />B.FEEDER DIRECTORIES BRANCH: PROVIDE EACH FEEDER, BRANCH CIRCUIT, FEEDER <br />MODIFICATION, AND BRANCH CIRCUIT MODIFICATION WITH A TYPED CIRCUIT DIRECTORY <br />LABEL. REFER TO TECHNICAL EQUIPMENT SPECIFICATION SECTIONS FOR ADDITIONAL <br />REQUIREMENTS. INCLUDE THE FOLLOWING WITH EACH LABEL: <br />1.LOAD DESCRIPTION: LIGHTING, RECEPTACLES, SPECIFIC EQUIPMENT, SPARE, SPACE, <br />OR SIMILAR DESCRIPTION. <br />2.LOCATION: ROOM NAME, NUMBER, LOCATION. <br />C.PROVIDE A FACTORY OR CUSTOM CLEAR PLASTIC SLEEVE FOR EACH BRANCH PANEL <br />DIRECTORY AND SECURE TO INSIDE PANEL COVER. <br />3.3 LIGHTING CONTROL AND RECEPTACLE COVER PLATES <br />A.IDENTIFICATION TO BE ENGRAVED DIRECTLY ON THE STAINLESS STEEL COVERPLATES. <br />LETTER AND NUMBER SIZE TO 1/8-INCH (3MM) HIGH. <br />B.PROVIDE IDENTIFICATION ON ALL SWITCH AND RECEPTACLE COVER PLATES. <br />IDENTIFICATION SHALL INDICATE SOURCE AND CIRCUIT NUMBER SERVING THE DEVICE <br />(E.G. "C1A -24"). <br />3.4 CONDUIT AND EXPOSED CABLE LABELING <br />A.PRODUCT: <br />1.ADHESIVE LABELS AND FIELD MARKINGS <br />B.CONDUIT IDENTIFICATION: PRE-PRINTED, FLEXIBLE, SELF-ADHESIVE VINYL LABELS WITH <br />LEGEND AT 20 FOOT (6 METER) INTERVALS TO IDENTIFY ALL CONDUITS RUN EXPOSED OR <br />LOCATED ABOVE ACCESSIBLE CEILINGS. CONDUITS LOCATED ABOVE NON-ACCESSIBLE <br />CEILING OR IN FLOORS AND WALLS SHALL BE LABELED WITHIN 3 FEET OF BECOMING <br />ACCESSIBLE, OR SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, AND <br />FLOORS. LABELS FOR MULTIPLE CONDUITS SHALL BE ALIGNED. REFER TO COLOR <br />REQUIREMENTS IN PART 2 WHEN APPLICABLE IN ADDITION TO THE FOLLOWING: <br />1.1000 VOLT OR LESS NORMAL/EMERGENCY POWER: INDICATE FEEDER IDENTIFICATION <br />AND VOLTAGE. <br />2.FIRE ALARM: INDICATE "FIRE ALARM". <br />3.GROUNDING: INDICATE "GROUND" AND EQUIPMENT AND DESIGNATION. <br />4.TELEPHONE SYSTEM: INDICATE "TELEPHONE". <br />C.BLANK CONDUIT ENDS OR OUTLET BOXES FOR FUTURE EXTENSION OF SYSTEM SHALL <br />HAVE PERMANENT IDENTIFICATION MARKER INDICATING PURPOSE OF CONDUIT OR BOX <br />AND WHERE THE RACEWAY ORIGINATED. <br />3.5 BOX LABELING <br />A.PRODUCTS: <br />1.ADHESIVE LABELS AND FIELD MARKINGS <br />B.IDENTIFY JUNCTION, PULL AND CONNECTION BOXES: LABELING SHALL BE 3/8-INCH (10MM) <br />KROY TAPE OR BROTHER SELF-LAMINATING VINYL LABEL, LETTERS/NUMBERS COLOR <br />CODED SAME AS CONDUITS. IN ROOMS THAT ARE PAINTED OUT, PROVIDE LABELING ON <br />INSIDE OF COVER. <br />C.ALL JUNCTION, PULL, AND CONNECTION BOXES SHALL BE IDENTIFIED AS FOLLOWS: <br />1.FOR POWER AND LIGHTING CIRCUITS, INDICATE SYSTEM VOLTAGE AND IDENTITY OF <br />CONTAINED CIRCUITS ("120V, 1LA1-3,5,7"). <br />2.FOR OTHER WIRING, INDICATE SYSTEM TYPE AND DESCRIPTION OF WIRING ("FIRE <br />ALARM NAC #1"). <br />3.6 CONDUCTOR COLOR CODING <br />A.PRODUCTS: <br />1.ALL WIRE AND CABLES SHALL BE COLOR CODED BY THE MANUFACTURER. <br />2.WIRE AND CABLES SMALLER THAN 6 AWG SHALL BE COLOR CODED BY THE <br />MANUFACTURER. <br />B.WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXISTS IN A BUILDING OR FACILITY, <br />EACH UNGROUNDED CONDUCTOR OF A MULTI-WIRE BRANCH CIRCUIT, WHERE <br />ACCESSIBLE, SHALL BE IDENTIFIED BY PHASE AND SYSTEM. <br />C.CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: <br />1.208Y/120 VOLT, 4-WIRE: <br />a.A-PHASE -BLACK <br />b.B-PHASE -RED <br />c.C-PHASE -BLUE <br />d.NEUTRAL -WHITE <br />e.GROUND BOND -GREEN <br />2.480Y/277 VOLT, 4-WIRE: <br />a.A-PHASE -BROWN <br />b.B-PHASE -ORANGE <br />c.C-PHASE -YELLOW <br />d.NEUTRAL -GRAY <br />e.GROUND BOND -GREEN <br />3.GROUNDING CONDUCTORS: <br />a.EQUIPMENT GROUNDING CONDUCTORS, MAIN/SYSTEM/SUPPLY-SIDE BONDING <br />JUMPERS: GREEN. <br />4.CABLING FOR REMOTE CONTROL, SIGNAL, AND POWER LIMITED CIRCUITS: <br />a.FIRE ALARM: REFER TO FIRE ALARM AND AUTOMATIC DETECTION SECTION 28 31 00 <br />FOR CABLE COLOR REQUIREMENTS. <br />b.LOW VOLTAGE SWITCHING: PER MANUFACTURER RECOMMENDATIONS AND CODE <br />REQUIREMENTS. <br />END OF SECTION <br />No. Revisions Date <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l