Laserfiche WebLink
<br /> <br /> Page 10 of 111 <br /> <br />Report No.: 2410B0143SHA-001 <br /> <br />TRF No. ANSI/CAN/UL 9540A_Unit <br />Test result from module level 9540A test report <br />Module level test report ............................................ : Refer to TÜV SÜD Report No.: 5061724026506 <br />Heating rate .............................................................. : 5 K/min <br />Thermal runaway Propagation ................................. : 1 cell went to thermal runaway due to external heating . <br />7 cells vented and went to thermal runaway due to <br />thermal runaway propagation. <br />Thermal runaway was observed on all 8 cells of the cell <br />block (8S), containing the initiating cell. <br />No thermal runaway was observed on the block (7S) <br />without initiating cell. <br />Peak chemical heat release rate HRR (kW) ............ : 32.7 kW <br />Peak smoke release rate SRR (m2/s) ...................... : 4.2 m2/s <br />Total smoke release TSR (m2) ................................ : 371.0 m2 <br />Total Hydrocarbons (equivalent to CH4, measured by <br />FID) .......................................................................... : Not provided. <br />Module weight loss (kg) ............................................ : 2.88 kg <br />Diagram of module with overall dimension (unit: mm) <br /> <br /> <br /> <br /> <br />(420±1)mm* (133±1)mm* (483±1) mm <br /> <br />