PER TABLE 2304.10.2 OF 2022 CBC <br />1.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL GRADES, DIMENSIONS, <br />ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING AND COMMENCING <br />CONSTRUCTION. CROSS CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL <br />DRAWINGS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, <br />AND CIVIL DRAWINGS AND NOTIFY THE ENGINEER AND THE ARCHITECT/DESIGNER OF ANY <br />DISCREPANCIES PRIOR TO STARTING WORK. <br />2.EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS OR <br />SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE <br />REQUIREMENTS OF THE CBC 2022 (2021 IBC WITH CALIFORNIA AMENDMENTS), AS WELL AS ALL <br />APPLICABLE STATE AND LOCAL ORDINANCES AS ADOPTED BY THE CONTROLLING JURISDICTION. <br />3.THE CONTRACT DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE <br />METHOD OF CONSTRUCTION. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY <br />SOUND ONLY IN THE COMPLETED FORM. GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING <br />CONSTRUCTION. SUCH MEASURES INCLUDE, BUT ARE NOT LIMITED TO; BRACING, SHORING FOR <br />CONSTRUCTION EQUIPMENT, AND SHORING FOR THE STRUCTURE. <br />4.IN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS. ANY <br />DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT AND ENGINEER FOR CLARIFICATION PRIOR TO PROCEEDING. ANY <br />WORK INSTALLED PRIOR TO AND/OR IN CONFLICT WITH SUCH CLARIFICATION SHALL BE <br />CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE <br />OWNER. <br />5.THE PRECISE DIMENSIONS AND LOCATIONS OF ALL DOOR AND WINDOW OPENINGS, INTERIOR <br />AND EXTERIOR WALLS SHALL BE DETERMINED FROM THE ARCHITECTURAL DRAWINGS. OTHER <br />FLOOR, WALL AND ROOF OPENINGS AS REQUIRED FOR MECHANICAL, ELECTRICAL AND/OR <br />SIMILAR REQUIREMENTS SHALL BE VERIFIED FROM SHOP DRAWINGS, EQUIPMENT DATA, ETC. AS <br />REQUIRED. <br />6.FLOOR AND WALL OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB ELEVATIONS, <br />DEPRESSED AREAS, AND ALL OTHER ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR CIVIL <br />REQUIREMENTS MUST BE COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH <br />CONSTRUCTION. <br />7.THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION AND COORDINATION WITH <br />ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER DRAWINGS, AND <br />ALL OTHER RELATED DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF <br />ALL WORK, INCLUDING THAT OF THE SUBTRADES. <br />8.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS INCLUDED IN THE <br />SPECIFICATIONS AND NOTES ON THE DRAWINGS, OR BETWEEN GENERAL NOTES AND SPECIFIC <br />DETAILS, THE ENGINEER SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE <br />CONTRACT DOCUMENTS. <br />9.ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS ALTERNATES ARE APPROVED IN <br />WRITING BY THE ARCHITECT, OWNER AND STRUCTURAL ENGINEER OF RECORD. <br />10.ANY REFERENCE TO THE WORDS APPROVED, OR APPROVAL IN THESE DOCUMENTS SHALL BE <br />DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE THE <br />CONTRACTOR AND/OR HIS SUBCONTRACTORS OF ANY LIABILITY IN FURNISHING THE REQUIRED <br />MATERIALS OR LABOR SPECIFICATION. <br />11.WHERE A DETAIL, SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL <br />LIKE OR SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. DETAILS MARKED "TYPICAL" SHALL <br />APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS <br />SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO LIKE CASES OF <br />CONSTRUCTION. <br />12.CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE RESPONSIBILITY OF THE <br />DISCIPLINES WHO MAKE THESE ATTACHMENTS. REVIEW AND COORDINATE ALL THE <br />REQUIREMENTS IN THE ARCHITECTS PROJECT SPECIFICATION AS APPLICABLE. <br />13.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, <br />WHETHER INDICATED ON THE CONTRACT DRAWING OR NOT, AND TO PROTECT THEM FROM <br />DAMAGE. REPAIR AND REPLACEMENT OF SAID WORK SHALL BE AT THE EXPENSE OF THE <br />CONTRACTOR. <br />14.VIBRATIONAL EFFECTS OF MECHANICAL AND/OR ANY OTHER EQUIPMENT HAVE NOT BEEN <br />CONSIDERED BY THE STRUCTURAL ENGINEER. <br />15.UNLESS NOTED OTHERWISE, ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE TO THE <br />TOP OF BEAMS AND FOUNDATIONS. BEAMS DENOTED AS "DROP"OR "DR" HAVE THE TOP OF <br />BEAM AT THE HEIGHT OF THE TOP PLATE. BEAMS DENOTED AS "FLUSH" OR "FL" HAVE THE <br />BOTTOM OF BEAM AT THE HEIGHT OF THE TOP PLATE, U.N.O. <br />GENERAL <br />1.ALL FRAMING SHALL CONFORM TO THE GRADES AS SET BY THE W.C.L.I.B. OR W.W.P.A. AND THE <br />CBC AND NATIONAL DESIGN SPECIFICATION (N.D.S.). ALL LUMBER SHALL BEAR THE GRADE <br />STAMP OF AN APPROVED TESTING AGENCY, EXCEPT EXPOSED LUMBER AT VISIBLE AREAS. <br />2.ALL LUMBER USED FOR STRUCTURAL PURPOSES SHALL BE DOUGLAS FIR, COAST REGION, GRADED <br />IN ACCORDANCE WITH THE WEST COAST LUMBER INSPECTION BUREAU. ALL LUMBER SHALL <br />HAVE LESS THAN 19% MOISTURE CONTENT. <br />3.UNLESS NOTED OTHERWISE, THE MINIMUM GRADE SHALL BE AS FOLLOWS: <br />·HORIZONTAL FRAMING MEMBERS (JOISTS AND BEAMS) <br />2X D.F. #2 <br />4X10 OR SMALLER D.F. #2 <br />4X12 OR LARGER D.F. #1 <br />6X D.F. #1 <br />8X D.F. #1 <br />·VERTICAL FRAMING MEMBERS (STUDS AND POSTS) <br />2X4 STANDARD OR STUD GRADE <br />2X6 D.F. #2 <br />4X4, 4X6 D.F. #2 <br />6X6 OR LARGER D.F. #1 <br />·MISCELLANEOUS <br />SILL PLATE P.T.D.F. STANDARD GRADE <br />2X TOP PLATE/SOLE PLATE D.F. STANDARD GRADE <br />SHEAR BLOCKING D.F. STANDARD GRADE <br />NON-STRUCTURAL BLOCKING AND BRIDGING UTILITY <br />4.ALL SILL PLATES BEARING ON MASONRY OR CONCRETE FOUNDATION WALL OR SLAB ON GRADE <br />SHALL BE PRESSURE TREATED IN ACCORDANCE WITH CBC 2022 2303.1.9. MINIMUM TWO BOLTS <br />PER PLATE WITH AT LEAST ONE BOLT BETWEEN 5-12 INCHES OF PLATE ENDS. <br />5.BOLTS SHALL CONFORM TO ASTM A-307. ALL BOLTS THROUGH WOOD SHALL HAVE SQUARE <br />PLATE PER WASHER SCHEDULE BETWEEN BOLT HEADS / NUTS AND WOOD BEARING SURFACE. <br />BOLT HOLES SHALL BE BORED 1/32" TO 1/16" LARGER THAN THE BOLT DIAMETER ALL BOLTS <br />SHALL BE RE-TIGHTENED PRIOR TO BUILDING WRAP AND DRYWALL INSTALLATION. <br />6.LAG SCREWS SHALL CONFORM TO A.N.S.I. B.18 <br />7.PROVIDE 0.058" X 1.1/2" WIDE STEEL TIE STRAPS WITH 6-16d NAILS AT EACH SIDE WHERE PLATES <br />ARE INTERRUPTED BY UTILITY PENETRATIONS AT NON-SHEAR WALLS. IF PENETRATION OCCURS <br />AT SHEAR WALLS, NOTIFY THE ENGINEER PRIOR TO STARTING WORK. <br />8.WALL FRAMING TO BE 2X STUDS AT 16" O.C. ON EXTERIOR WALLS AND 2X STUDS AT 16" O.C. ON <br />INTERIOR WALLS. PROVIDE DOUBLE TOP PLATE ON ALL WALLS THE MAXIMUM STUD HEIGHT FOR <br />2X4 EXTERIOR WALL IS 10'. THE MAXIMUM 2X4 INTERIOR WALL HEIGHT IS 14'. THE MAXIMUM <br />NON-BEARING STUD HEIGHT FOR 2X6 STUDS IS 20' U.N.O. ON PLANS. <br />9.FOR PORTIONS OF BUILDING FRAMED PER CONVENTIONAL FRAMING PROVISIONS IN THE CBC <br />PROVIDE PLYWOOD/OSB PANELS WALL SHEATHING WITH 10D NAIL 6" O.C. AT EDGES AND 12" <br />O.C. AT FIELD <br />10.PROVIDE SINGLE JOIST UNDER NON-BEARING PARTITION PARALLEL TO JOIST. PROVIDE MINIMUM <br />OF TWO FLOOR JOISTS BELOW BEARING WALLS U.N.O. ON PLAN. <br />11.ROOF SHEATHING SHALL BE INSPECTED PRIOR TO PLACING INSULATION AND ROOFING. <br />12.ALL STRUCTURAL SHEATHING SHALL BE IDENTIFIED WITH THE GRADE TRADEMARK OF THE APA - <br />THE ENGINEERED WOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF PRODUCTS <br />STANDARD PS 1-95, PS2-9, OR PRP-108. ALL SHEATHING WHICH HAS ANY EDGE OR SURFACE <br />PERMANENTLY EXPOSED TO THE WEATHER SHALL BE OF THE EXTERIOR TYPE. SHEATHING LESS <br />THAN 24 INCHES IN ANY DIMENSION SHALL NOT BE USED IN SHEAR WALLS, FLOOR, OR ROOF <br />DIAPHRAGM. <br />WOOD FRAMING <br />NAILING SCHEDULE <br />A.B.ANCHOR BOLT <br />ABV.ABOVE <br />BAR.REINF. BAR <br />BD.BOARD <br />BLK'G. BLOCKING <br />BLW.BELOW <br />BM.BEAM <br />B.N.BOUNDARY NAIL <br />B.O.B BOTTOM OF BEAM <br />B.W.BOTH WAYS <br />CANT.X.CANTILEVER <br />CJ.CEILING JOIST <br />COL.COLUMN <br />CONC.CONCRETE <br />CONT.CONTINUOUS <br />DBL.DOUBLE <br />D.F.DOUGLAS FIR <br />DIA.DIAMETER <br />(E)EXISTING <br />E.W.EACH WAY <br />E.J.EXPANSION JOINT <br />E.N.EDGE NAIL <br />E.Q.EQUAL <br />F.G.FINISH GRADE <br />F.J.FLOOR JOIST <br />FL.FLUSH <br />F.N.FIELD NAIL <br />F.O.C.FACE OF CONCRETE <br />F.O.M.FACE OF MASONRY <br />F.O.S. FACE OF STUDS <br />GA. GAUGE <br />GALV. GALVANIZED <br />GLB. GLUE-LAMINATED BEAM <br />GR.BM. GRADE BEAM <br />GWB. GYPSUM WALLBOARD <br />HI. HIGH <br />HDR. HEADER <br />HFX HARDY FRAME <br />HORIZ. HORIZONTAL <br />K.P. KING POST <br />LT.WT. LIGHT WEIGHT <br />L.V.L. LAMINATED VENEER LUMBER <br />MAS. MASONRY <br />M.B. MACHINE BOLT <br />(N) NEW <br />N.G. NATURAL GRADE <br />O/C ON CENTER <br />P.J. POUR JOINT <br />PSL. PARALLAM BEAM <br />PLWD. PLYWOOD <br />P.T. PRESSURE TREATED <br />REINF. REINFORCING <br />REQ'D REQUIRED <br />RR. ROOF RAFTER <br />T.O.B TOP OF BEAM <br />UNO. UNLESS NOTED OTHERWISE <br />V.I.F. VERIFY IN FIELD <br />ABBREVIATIONS <br />DESIGN LOAD ( VERTICAL) <br />DEAD LOAD LIVE LOAD ROOF LIVE LOAD SNOW LOAD <br />CEILING 5 10 -- <br />EXTERIOR WALL 15 --- <br />INTERIOR WALL 10 --- <br />SHEET INDEX <br />NO.SHEET NUMBER SHEET TITLE <br />1 S-0 GENERAL NOTES & STRUCTURAL SPECS. <br />2 S-1 FRAMING PLAN <br />10.PROVIDE MINIMUM YIELD STRESS, FY , OF 50 KSI FOR 16 GAUGE (54 MIL) AND THICKER AND 33 KSI FOR 18 <br />GAUGE (43 MIL) AND THINNER. <br />11.COLD-FORMED STEEL JOISTS SHALL HAVE PUNCHED ENLARGED SERVICE HOLES WITH STIFFENED FLANGES. <br />12.EXTERIOR WALL STUDS SHALL BE 362S200-43 @24" O.C. AND SATISFYING THE REQUIREMENTS OF LOAD <br />BEARING STUD WALLS PER TABLE OF NOTE 13 BELOW (WHICHEVER IS GREATER).UNLESS NOTED OTHERWISE <br />ON PLANS. WALLS SHALL BE PROVIDED WITH MANUFACTURER'S STANDARD BRIDGING ( EITHER WELDED 2 <br />1/2"X18 GAUGE STUD OR CLIPPED COLD-ROLLED CHANNEL 1 1/2"X16" GAUGE). PROVIDE BRIDGING AT 4'-0" <br />O.C. MAXIMUM FOR LOAD BEARING WALLS AND EXTERIOR WALLS. <br />13. <br />EXCEPTION: WHERE FULL HEIGHT SHEATHING OR GYP BOARD OCCURS ON BOTH SIDE OF WALL STUDS, <br />BRIDGING IS ALLOWED TO BE OMITTED <br />SHOP DRAWINGS: WHERE IS PROPOSED TO DIFFER FROM DETAILS SHOWN, SUBMIT SHOP DRAWINGS. <br />SHOW METHOD OF STUD ATTACHMENT TO FLOOR AND CEILING TRACKS, ATTACHMENT OF TRACKS, <br />CONSTRUCTION OVER AND AROUND DOORS AND OTHER OPENINGS, AT CORNERS, CEILING DETAILS, <br />AND OTHER SIGNIFICANT FEATURES. <br />FRAMING AT DOOR JAMBS AND OPENINGS: PROVIDE SINGLE 18 GAUGE STUD OR DOUBLE 20 GAUGE <br />STUDS AT DOOR JAMBS AND CASED OPENINGS, AND OTHER LOCATIONS INDICATED. <br />CROSS-BRACING: UNLESS INDICATED ON DRAWINGS, CROSS-BRACING AT DOUBLE STUD WALLS AND <br />PARTITION SHALL NOT BE USED TO LIMIT DEFLECTION UNLESS ACOUSTICAL PERFORMANCE OF WALL OR <br />PARTITION IS NOT DEGRADED. <br />TRACKS, SILLS AND HEADERS: UNPUNCHED CHANNELS SIZED FOR STUD FLANGES, GAUGE THE SAME AS <br />STUDS UNLESS OTHERWISE NOTED. SLOTTED HEAD TRACKS AT STUDS TO STRUCTURE ABOVE. <br />METAL FRAMING FINISH: ALUMINUM-ZINC CORROSION RESISTANT COATING, ASTM A792 OR HOT <br />DIPPED GALVANIZED ASTM A525 G60. <br />SCREWS: AS RECOMMENDED OR REQUIRED BY MANUFACTURER, SELF-FILLING, SELF-TAPPING IN <br />ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br />MANUFACTURER'S PROPRIETARY TYPE " SSCJ" C-SHAPED STEEL JOISTS OF THE SIZE INDICATED ON WITH <br />EXTRA-LARGE TRAPEZOID-SHAPED SERVICE HOLES WITH FY=33 KSI FOR 18 GAUGE AND 50 KSI FOR 16, 14 <br />AND 12 GAUGE. <br />PROVIDE JOIST BRIDGING/BLOCKING @ 8'-0" O.C. MAXIMUM. <br />STUDS AND JOISTS INSTALLATION: INSTALL STUDS AND JOISTS AT 24 INCHES ON CENTER TYPICALLY, <br />UNLESS OTHERWISE INDICATED. DO NOT SPLICE STUDS AND JOISTS. PROVIDE STUDS NOT MORE THAN 2 <br />INCHES FROM EACH CORNER OF WALL OR ABUTTING CONSTRUCTION. <br />SECURE STUDS TO TOP AND BOTTOM TRACKS WITH 2-#10 SCREWS PER LOCATION. <br />BACKING PLATES: 16 GAUGE GALVANIZED SHEET METAL COVERING FULL WIDTH OF STUD SPACING BY 4 <br />INCH WIDE MINIMUM. INSTALL STUD TRACK OR SHEET METAL BACKING AS INDICATED AND AS <br />NECESSARY TO SUPPORT ALL PRODUCTS ATTACHED TO WALL OR CEILING AFTER COMPLETION OF FINISH <br />SURFACE, INCLUDING TOILET AND BATH ACCESSORIES, PLUMBING AND ELECTRICAL FIXTURE, ELECTRICAL <br />PANELS, TOILET PARTITIONS, CASEWORK, HARDWARE, HANDRAILS AND TRIM. <br />TRACK INSTALLATION: PLACE AND ALIGN TRACKS IN CONFIGURATIONS SHOWN. SECURE TOP, BOTTOM <br />AND SIDE TRACKS AT MAXIMUM 24 INCHES ON CENTER TO STRUCTURE USING FASTENERS AS DETAILED. <br />PROVIDE FOR DEFLECTION AT TOP TRACK OF PARTITION FRAMING ABUTTING STEEL FLOOR OR ROOF <br />DECK, AS INDICATED ON THE DRAWINGS. <br />COORDINATION: COORDINATE ERECTION OF STUDS AND JOISTS WITH INSTALLATION OF SERVICE UTILITIES <br />TO MINIMIZE DISCONTINUITY IN FARMING. ALIGN STUD WEB OPENINGS. COORDINATE WITH <br />INSTALLATION OF BUCKS, ANCHORS, BACKING, BLOCKING, PLUMBING, MECHANICAL AND ELECTRICAL <br />COMPONENTS TO PROVIDE NECESSARY CLEARANCES AND SUPPORTS. COORDINATE WITH REQUIREMENTS <br />FOR DOOR AND WINDOW FRAME SUPPORTS AND ATTACHMENTS. <br />CLEARANCES: MAINTAIN CLEARANCE UNDER BUILDING STRUCTURAL MEMBERS TO AVOID DEFLECTION <br />TRANSFER TO NON-LOAD BEARING FRAMING. <br />OPENINGS AND RECESSES: PROVIDE FRAMED OPENINGS FOR ALL RECESSED AND BUILT-IN COMPONENTS. <br />COORDINATE INSTALLATION OF FRAMING WITH REQUIREMENTS FOR DOOR AND WINDOW FRAME <br />SUPPORTS AND ATTACHMENTS. <br />BRACING INSTALLATION: INSTALL BRACING AT STUDS AND JOISTS TO MAKE RIGID. INSTALL INTERLOCKING <br />BRIDGING MEMBER THROUGH STUD WEB OPENINGS AT STUDS 7-1/2 FEET IN LENGTH OR GREATER. <br />H. COLD FORMED METAL FRAMING GENERAL NOTES <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />15. <br />16. <br />14. <br />1.ALL COLD-FORMED METAL FRAMING SHALL CONFIRM TO AISI STANDARD S240-20 "NORTH AMERICAN <br />SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS''. <br />2.SHALL MEET ALL THE REQUIREMENT AISI 2022 LATEST EDITION. <br />3.CONTRACTOR SHALL PROVIDE EFFECTIVE, FULL TIME QUALITY CONTROL OVER ALL FABRICATION AND <br />ERECTION COMPLYING WITH THE PERTINENT CODES AND REGULATIONS OF GOVERMENT AGENCIES HAVING <br />JURISDICTION. <br />4.PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO, TRACKS, CLIPS WEB STIFFENERS, ANCHORS, <br />FASTENING DEVICES, RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER <br />INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE STEEL MEMBERS USED. <br />5.FASTENING OF COMPONENTS SHALL BE WITH ICC APPROVED SELF-DRILLING SCREWS OR WELDING, SCREWS <br />OR WELDS SHALL BE OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION ALL WELDS OF <br />GALVANIZED STEEL SHALL BE TOUCHED UP WITH A ZIN-RICH PAINT. ALL WELDS OF CARBON SHEET STEEL <br />SHALL BE TOUCHED UP WITH PAINT. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITTED. <br />6.UNIFORM AND LEVEL JOIST BEARING SHALL BE PROVIDES AT FOUNDATION WALLS BY MEANS OF SHIMS <br />AND/OR NON-SETTING GROUT. <br />7.ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO AISI "SPECIFICATION FOR THE DESIGN OF COLD <br />FORMED STEEL'', LATEST EDITION. <br />8.ALL WELDING SHALL BE DONE BY CERTIFIED WELDERS IN FULL COMPLIANCE WITH AWS D1.3 <br />9.UNLESS NOTED OTHERWISE ON THE DRAWINGS, SCREWS SHALL BE #10-16 SELF DRILLING, SELF TAPPING HEX <br />HEAD SCREWS WITH HEAD DIAMETER OF 0.333 IN. <br />ALL WALL STUD FRAMING SHALL SATISFY THE REQUIREMENTS OF TABLE BELOW (U.N.O.). PROVIDE BRIDGING <br />AT 4'-0" O.C. MAXIMUM FOR LOAD BEARING WALLS. WHERE FULL HEIGHT SHEATHING OR GYP BOARD OCCURS <br />ON BOTH SIDE OF WALL STUDS, BRIDGING IS ALLOWED TO BE OMITTED. <br />(inches) <br />24362S200-43 24 <br />(feet) <br />9.5 <br />(inches) <br />24 <br />(feet) <br />16'-0" <br />(inches)(inches) <br />-- <br />362S200-43 16 1614 2416'-0"16 <br />17. <br />IN-LINE FRAMING: EACH JOIST, RAFTER, TRUSS, AND STRUCTURAL WALL STUD (ABOVE OR BENEATH) <br />SHALL BE ALIGNED VERTICALLY ACCORDING TO LIMIT OF AISI-S200 (SEE 2/SD2 FOR LIMITS). THE <br />ALIGNMENT TOLERANCE IS NOT REQUIRED WHERE LOAD DISTRIBUTION MEMEBER IS SPECIFIED IN PLAN <br />DRAWINGS OR DETAILS. <br />MAXIMUM SPACING WHEN SUPPORTING <br />NON-BEARING WALLS BEARING WALLS <br />MAXIMUM SPACING <br />STUD SIZE STUD <br />HEIGHT ROOF & <br />CL'G ONLY <br />ONE FLOOR <br />ROOF & CL'G <br />TWO FLOOR <br />ROOF & CL'G <br />STUD <br />HEIGHT <br />COLD FORMED METAL FRAMING <br />PROJECT DESIGN CRITERIA <br />BUILDING CODE 2022 CBC <br />OCCUPANCY CATEGORY II <br />GEOTECHNICAL PARAMETERS <br />GEOTECHNICAL ENGINIEER CHAPTER 18 MIN. <br />GEOTECHNICAL COMPANY'S ADDRESS N/A <br />GEOTECHNICAL COMPANY'S TELEPHONE NUMBER N/A <br />REPORT NUMBER N/A <br />DATE N/A <br />ALLOWABLE SOIL BEARING PRESSURE 1500 PSF <br />COEFFICIENT OF FRICTION 0.3 <br />LATERAL DESIGN PARAMETERS <br />SEISMIC DESIGN PARAMETERS (EQV. LATERAL FORCE PROCEDURE) <br />SEISMIC DESIGN CATEGORY D <br />SEISMIC IMPORTANCE FACTOR, Ie 1 <br />SITE CLASS D- DEFAULT <br />SHORT PERIOD SPECTRAL ACCELERATION, Ss 1.272 <br />1ST PERIOD SPECTRAL ACCELERATION, S1 0.456 <br />SHORT PERIOD ACCELERATION PARAMETER, SDS 1.017 <br />1 SECOND ACCELERATION PARAMETER, SD1 0.561 <br />LATERAL FORCE RESISTING SYSTEM <br />RESPONSE MODIFICATION FACTOR, R 1.5 <br />SEISMIC RESPONSE COEFFIECIENT, Cs 0.678 <br />DESIGN BASE SHEAR V = 0.7CsW 0.475W <br />WIND DESIGN PARAMETERS (ASCE 7-16, METHOD 2) <br />EXPOSURE CATEGORY C <br />DESIGN WIND SPEED 95 PMH <br />WIND IMPORTANCE FACTOR, Iw 1.0 <br />DESCRIPTION OF <br />BUILDING ELEMENTS <br />NUMBER & TYPE <br />OF FASTENER <br />SPACING & <br />LOCATION <br />1. Blocking between ceiling joists, <br />rafters or trusses to top plate <br />or other framing below <br />ROOF <br />3-8d common (2 1/2"x0.131"); or <br />3-10d box (3″ x 0.128″); or <br />3-3″ × 0.131″ nails; <br />Each end, toenail <br />2-8d common (2 1/2" x 0.131")Blocking between rafters or truss <br />to rafter or truss <br />2-3″ × 0.131″ nails <br />2-16 d common (3 1/2" x 0.162") <br />3-3″ × 0.131″ nails <br />not at the wall top plate, <br />Each end, toenail <br />Each end <br />16d common (3 1/2"x0.162") @6"o.c.Flat blocking to truss and web filler <br />3″ × 0.131″ nails @ 6″ o.c. <br />Face nail <br />2. Ceiling joists to top plate 3-8d common (2 1/2"x0.131"); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; <br />Each joist, toenail <br />3. Ceiling joist not attached to parallel <br />rafter, lap over partitions (no thrust) <br />(see Section R802.5.2, <br />3-16d common (3 1/2"x0.162"); or <br />4-10d box (3″ x 0.128″); or <br />4-3″ × 0.131" nails; <br />Face nail <br /> Table R802.5.2.(1)) <br />4. Ceiling joist attached to parallel <br />(see Section R802.5.2, <br />Per Table R802.5.2.(1)Face nailrafter (heel joint) <br /> Table R802.5.2.(1)) <br />5. Collar tie to rafter 3-10d common (3″ x 0.148″); or <br />4-10d box (3″ x 0.128″); or <br />4-3″ × 0.131″ nails; <br />Face nail <br />6. Rafter or roof truss to top plate 3-10 common (3″ x 0.148″); or <br />3-16d box (3 1/2" x 0.135"); or <br />4-10d box (3" x 0.128″); or <br />4-3″ × 0.131 nails; <br />Toenail i <br />7. Roof rafters to ridge valley or hip <br />3-10d common (3 1/2"x0.148"); or <br />4-16d box (3 1/2"x0.135"); or <br />4-10d box (3″ x 0.128″); or <br />4-3″ × 0.131″ nails; <br />Toenail <br />2-16d common (3 1/2"x0.162"); or <br />3-10d box (3″ x 0.128″); or <br />3-3″ × 0.131″ nails; <br />End nail <br />rafters; or roof rafter to 2-inch ridge <br />beam <br />16d common (3 1 <br />8. Stud to stud <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; <br />24″ o.c. face nail <br />16″ o.c. face nail <br />/2″ × 0.162″); <br />(not at braced wall panels) <br />9. Stud to stud and abutting studs <br />(at braced wall panels) <br />16d common (3 1/2"x0.162"); <br />16d box (3 1/2"x0.135"); <br />3″ × 0.131″ nails; <br />16″ o.c. face nail <br />12″ o.c. face nail <br />12″ o.c. face nail <br />at intersecting wall corners <br />10. Built-up header (2″ to 2″ header 16d common (3 1/2"x0.162"); <br />16d box (3 1/2"x0.135") <br />16″ o.c. ea. edge, face nail <br />12″ o.c. ea. edge, face nail <br />11. Continuous header to stud 4-8d common (2 1/2"x0.131") ; or <br />4-10d box (3″ × 0.128″) <br />Toenail <br />12. Adjacent full-height stud to end 4-16d box (31/2"x 0.135"); or <br />3-16d common (31/2" x 0.162"); or End nail <br />16d common (31/2" × 0.162")13. Top plate to top plate <br />15. Bottom plate to joist, rim joist, <br /> (not at braced wall panels) <br />16. Bottom plate to joist, rim joist, <br /> wall panels <br />16d common (3 1/2″ × 0.162″); <br />16d box (3 1/2″ × 0.135″); or <br />3″ × 0.131″ nails; <br />2-16d common (3 1/2″ × 0.162″); or <br />3-16d box (3 1/2″ × 0.135″); or <br />12" o.c. face nail <br />4-3″ × 0.131″ nails; <br />4-8d box (21/2" × 0.113"); or <br />17. Top or bottom plate to stud <br />3-16d box (31/2" × 0.135"); or <br />4-8d common (21/2" × 0.131"); or <br />2-16d common (3 1/2″ × 0.162″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; <br />2-16d common (3 1/2″ × 0.162″); or18. Top plates, laps at corners <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; <br />Toenail <br />End nail <br />Face nail <br />16" o.c. face nail <br />16" o.c. face nail <br /> band joist or blocking <br /> band joist or blocking at braced <br /> and intersections <br />WALL <br />2-8d common (2 1/2″ × 0.131″); or <br />19. 1″ brace to each stud and plate <br />20. 1″ × 6″ sheathing to each bearing <br />21. 1″ × 8″ and wider sheathing <br />2-10d box (3″ × 0.128″); or <br />2 staples 1 3/4" <br />2-8d common (2 1/2″ × 0.131″); or <br />2-10d box (3″ × 0.128″) <br />4-8d box (21/2" × 0.113"); or <br />3-8d common (21/2" × 0.131"); or <br />Face nail <br />Face nail <br />Face nail <br /> to each bearing <br />Edges <br />(inches) <br />Intermediate supports <br />(inches) <br />31.3/8″ - 1/2" <br />6d common or deformed (2″x0.113″x <br />0.266" head)(subfloor and wall) <br />8d common (21/2" × 0.131") nail <br />RSRS-01 (2 3/8" × 0.113") nail (roof) <br />2 3/8″ x0.113″ x 0.266" head nail <br />6 <br />6 <br />6 <br />6 <br />(roof) <br />32. 19/32" - 3/4" <br />33. 7/8"- 1 1/4" <br />8d common (2 1/2″ × 0.131″) <br />nail (subfloor, wall) <br />10d common (3″ × 0.148″); or <br />deformed nail <br />34. 1/2″ structural cellulosic <br />1 1/2" × 0.120" galvanized roofing <br />1 1/4" long 16 ga. staple with 7/16" <br />6 <br />6 <br />12 <br />12 <br />3 6 <br />3 6 <br />OTHER EXTERIOR WALL SHEATING <br />WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING <br />Deformed (2"× 0.113") or <br />Deformed (2" × 0.120") nail; or 6 12 <br />For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s; 1 ksi = 6.895 MPa. <br />WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF AND <br />INTERIOR WALL SHEATING TO FRAMING AND PARTICLEBOARD WALL SHEATING TO FRAMING <br />FLOOR <br />3-8d common (21/2" × 0.131"); or <br />22. Joist to sill, top plate, or girder <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; <br />Toenail <br />8d common (2 1/2″ × 0.131″); or <br />23. Rim joist, band joist, or blocking <br /> below 10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; <br />6" o.c., toenail <br /> to top plate, sill or other framing <br />25. 2″ subfloor to joist or girder <br />26. 2" planks (plank & beam-floor <br />2-16d common (3 1/2″ × 0.162″) <br />2-16d common (3 1/2″ × 0.162″) <br />Blind and face nail <br />Each bearing, face nail <br /> & roof) <br />20d common (4″ × 0.192″) <br />28. Built-up girders and beams, <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; <br />Nail each layer as follows: <br /> 32" o.c. at top and bottom <br />24" o.c., face nail at top <br />and bottom staggered on <br />and staggered. <br />on opposite sides <br />And: <br />2-20d common (4″ × 0.192″); or <br />3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; <br />Ends and at each <br />splice, face nail <br /> 2″ lumber layers <br />3-16d common (3 1/2″ × 0.162″); or29. Ledger strip supporting joists <br />4-10d box (3″ × 0.128″); or <br />4-3″ × 0.131″ nails; <br />Each joist or rafter, <br />face nail or rafters <br />2-8d common (2 1/2″ × 0.131″); or <br />30. Bridging or blocking to joist,2-10d box (3″ × 0.128″); or <br />2-3″ × 0.131″ nails; <br />Each end, toenail <br /> rafter or truss <br />4-8d box (2 1/2"x0.113"); or <br />4-8d box (2 1/2"x0.113"); or <br />3-16d box (31/2" x 0.135"); or <br />with 1/2" spacer)) <br />5-8d box (21/2" x 0.113"); or <br />of header 4-10d box (3" x 0.128"); or <br />4-3" × 0.131" nails <br />8-16d common (3 1/2"x0.162"); or14. Double top plate splice <br />12-10d box (3″ × 0.128″); or <br />12-3″ × 0.131″ nails; <br />Each side of end joint, <br />face nail (min. 24" lap <br />splice length each side <br />of end joint) <br />12-16d box (31/2" × 0.135"); or <br />10d box (3" × 0.128"); or <br />3" × 0.131" nails <br />16" o.c. face nail <br />12" o.c. face nail <br />3-16d box (31/2" × 0.135"); or <br />4-10d box (3" × 0.128"); or <br />4-3" × 0.131" nails <br />3-8d box (21/2" × 0.113"); or <br />2 staples, 1" crown,16 ga.,13/4" long <br />3-8d box (21/2" × 0.113"); or <br />Wider than 1" × 8" <br />3-10d box (3" × 0.128"); or <br />4 staples,1" crown, 16 ga.,13/4" long <br />4-8d box (21/2" × 0.113"); or <br />8d box (21/2" × 0.113") 4" o.c., toenail <br />24. 1"x6" subfloor or less to each joist 3-8d box (21/2" × 0.113"); or <br />2-8d common (21/2" × 0.131"); or <br />3-10d box (3" × 0.128"); or <br />2 staples,1" crown, 16 ga.,13/4" long <br />Face nail <br />3-16d box (31/2" × 0.135"); or <br />3-16d box (31/2" × 0.135"); or <br />27. Band or rim joist to joist <br />4-10 box (3" × 0.128"); or <br />3-16d common (31/2" × 0.162"); or <br />4-3" × 0.131" nails; or <br />4-3" × 14 ga. staples, 7/16" crown <br />End nail <br />4-16d box (31/2" × 0.135"); or <br />f <br />6f <br />6f <br />(subfloor, wall)i 6 6f <br />b <br />8d common (2 1/2″ × 0.131″) <br />nail (roof); or, <br />RSRS-01 (2 3/8" × 0.113") nail (roof) <br />b 6 6f <br />Deformed 23/8" × 0.113" × 0.266" <br />head (wall or subfloor) 6 12 <br />(21/2" × 0.131 × 0.281" head) <br />g <br />a, b, c <br />fiberboard sheathing <br />1" crown <br />nail,7/16" head diameter; or <br />35. 25/32″ structural cellulosic <br />fiberboard sheathing <br />1 3/4" × 0.120" galvanized roofing <br />1 1/4" long 16 ga. staple with 7/16" <br />1" crown <br />nail,7/16" head diameter; or <br />7 7 <br />36. 1/2" gypsum sheathing <br />1 1/2" × 0.120" galvanized roofing <br />1 1/4" long 16 ga; <br />staple galvanized, 1 1/2" long; <br />nail,7/16" head diameter; or <br />7 7 <br />37. 5/8" gypsum sheathing <br />d <br />d <br />7/16" or 1" crown or 11/4" screws, <br />Type W or S <br />1 3/4" × 0.120" galvanized roofing <br />1 1/4" long 16 ga; <br />staple galvanized, 1 1/2" long; <br />nail,7/16" head diameter; or <br />7/16" or 1" crown or 11/4" screws, <br />Type W or S <br />38. 3/4" and less <br />8d common (21/2" × 0.131") nail <br />8d common (21/2" × 0.131") nail; or <br />Deformed (2" × 0.113"); or 6 1239. 7/8" - 1" <br />Deformed (21/2" × 0.120") nail <br />10d common (3" × 0.148" ) nail; or <br />Deformed (2" × 0.113");or 6 1240. 1 1/8" - 1 1/4" <br />Deformed (21/2" × 0.120") nail <br />a. Nails are smooth-common, box or deformed shanks except where otherwise stated. Nails used for <br />framing and sheathing connections are carbon steel and shall have minimum average bending yield <br />strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for shank <br />diameters larger than 0.142 inch but not larger than 0.177 inch, and 100 ksi for shank diameters of <br />0.142 inch or less. Connections using nails and staples of other materials, such as stainless steel, shall <br />be designed by accepted engineering practice or approved under Section R104.11. <br />b. RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. <br />c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches <br />or greater. <br />d. Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically. <br />e. Spacing of fasteners not included in this table shall be based on Table R602.3(2). <br />f. For wood structural panel roof sheathing attached to gable end roof framing and to intermediate <br />supports within 48 inches of roof edges and ridges, nails shall be spaced at 4 inches on center where <br />the ultimate design wind speed is greater than 130 mph in Exposure B or greater than 110 mph in <br />Exposure C. <br />g. Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with ASTM <br />C1280 or GA 253. Fiberboard sheathing shall conform to ASTM C208. <br />h. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing <br />members and required blocking and at floor perimeters only. Spacing of fasteners on roof sheathing <br />panel edges applies to panel edges supported by framing members and required blocking. Blocking <br />of roof or floor sheathing panel edges perpendicular to the framing members need not be provided <br />except as required by other provisions of this code. Floor perimeter shall be supported by framing <br />members or solid blocking. <br />i. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, <br />provide two toe nails on one side of the rafter and toe nails from the ceiling joist to top plate in <br />accordance with this schedule. The toe nail on the opposite side of the rafter shall not be required. <br />BLKG WHERE REQ'D. <br />BOUNDARY NAILING 6" O.C. U.N.O. <br />(B.N.) <br />FIELD NAILING <br />12" O.C. U.N.O.) <br />2ND ROW <br />PLYWD. SHEET <br />STAGGERED <br />BOUNDARY NAILING <br />(B.N.) <br />PLYWD. PANEL <br />LAY PERP. TO <br />ROOF FRAMING <br />BLDG. EXT. WALLS <br />ROOF FRAMING <br />(TRUSS/JOIST/RAFTER) <br />EDGE NAILING (6" O.C. U.N.O.) <br />(E.N.) <br />SHEATHING NAILING <br />ROOF <br />- 15/32 INCH A.P.A. RATED SHEATHING (EXP. 1, 32 / 16)8d's @ 6" O.C. E.N. <br />8d's @ 12" O.C. F.N.- 15/32 INCH OSB PANEL, PANEL EDGE CLIP, 32/16 SPAN RATING <br />FLOOR <br />- 23/32 INCH APA RATED STURD-I-FLOOR, EXP. 1, <br /> T & G OR PANEL EDGE CLIP, 24" O.C. SPAN RATING <br />10d's @ 6" O.C. E.N. <br />10d's @ 12" O.C. F.N. <br />- 19/32 INCH APA RATED STURD-I-FLOOR, EXP. 1, <br /> T & G OR PANEL EDGE CLIP, 20" O.C. SPAN RATING <br />- 23/32 INCH OSB WITH PANEL EDGE CLIP, 40/20 SPAN RATING <br />- 19/32 INCH OSB WITH PANEL EDGE CLIP, 32/20 SPAN RATING <br />TYP. ROOF & FLOOR PLYWD. LAYOUT <br />14. ROOF AND FLOOR SHEATHING, AND SHEAR WALL PANELS, NAILING AND INSTALLATION SHALL BE <br />INSPECTED AND APPROVED BY THE BUILDING DEPARTMENT PRIOR TO COVERING. <br />15. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, CONDUITS, ETC. UNLESS SPECIFICALLY <br />DETAILED ON DRAWINGS. <br />16. UNLESS NOTED OTHERWISE ON THE PLANS, COMPLY WITH CBC TABLE 2304.10.2 FOR NAILING <br />SCHEDULE. <br />17. ALL NAILS SHALL BE COMMON NAILS IN COMPLIANCE WITH FEDERAL SPECIFICATIONS FF-N-105B. <br />SINKERS SHALL NOT BE ALLOWED UNLESS SPECIFIED OR APPROVED BY THE ENGINEER. ALL NAILS <br />EXPOSED TO WEATHER, HEAT AND/OR MOISTURE SHALL BE GALVANIZED. <br />18. ALL WOOD IN CONTACT WITH THE GROUND, MASONRY, OR CONCRETE WITHIN 18" OF THE <br />GROUND SHALL BE PRESSURE TREATED, OR HEART REDWOOD/CEDAR WITH APPROVED <br />RESISTANCE TO DECAY AND ATTACK FROM INSECTS. <br />19. MINIMUM DIMENSION OF ROOF SHEATHING TO BE 24" PER 2021 SDPWS SECTION 4.2.8 <br />13. ALL STRUCTURAL SHEATHING SHALL BE IDENTIFIED WITH THE GRADE TRADEMARK OF THE APA - <br />THE ENGINEERED WOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF PRODUCTS <br />STANDARD PS 1-95, PS2-9, OR PRP-108. ALL SHEATHING WHICH HAS ANY EDGE OR SURFACE <br />PERMANENTLY EXPOSED TO THE WEATHER SHALL BE OF THE EXTERIOR TYPE. SHEATHING LESS <br />THAN 24 INCHES IN ANY DIMENSION SHALL NOT BE USED IN SHEAR WALLS, FLOOR, OR ROOF <br />DIAPHRAGM. <br />- <br />DRAWN: <br />DATE: <br />SCALE: <br />JOB NO. <br />REVISIONS <br />AS NOTE <br />03/15/2026 <br />26033 <br />J.C. <br />DE <br />Y <br />I <br /> <br />C <br />O <br />N <br />S <br />U <br />L <br />T <br />A <br />N <br />T <br />S <br />, <br /> <br />I <br />N <br />C <br />39 <br />4 <br />3 <br /> <br />I <br />R <br />V <br />I <br />N <br />E <br /> <br />B <br />L <br />V <br />D <br />. <br /># <br />7 <br />6 <br />5 <br /> I <br />R <br />V <br />I <br />N <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />0 <br />2 <br /> 9 <br />4 <br />9 <br />- <br />6 <br />5 <br />6 <br />- <br />6 <br />1 <br />3 <br />4 <br />JU <br />N <br />F <br />E <br />I <br />. <br />C <br />H <br />E <br />N <br />@ <br />D <br />E <br />Y <br />I <br />C <br />O <br />N <br />S <br />U <br />L <br />T <br />A <br />N <br />T <br />S <br />. <br />C <br />O <br />M <br />- <br />LY <br />N <br />N <br />K <br />O <br /> <br />B <br />A <br />K <br />E <br />R <br />Y <br />2 <br />H <br />U <br />T <br />T <br />O <br />N <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />D <br />R <br />. <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />GENERAL NOTES & <br />STRUCTURAL SPEC. <br />S-0 <br />EXP. DATE: 09/30/2026