(N) TESLA POWERWALL 3 1707000-21 <br />INVERTER/W INTEGRATED BATTERY (240V) <br />(E) METER/MAIN SERVICE PANEL (1 OF 2) <br />W/(N) TESLA BACKUP SWITCH <br />(N) VISIBLE LOCKABLE LABELED <br />PV & ESS AC DISCONNECT (2 OF 2) <br />(N) PV MODULES W/ (1) MCI-2 <br />RSD PER 3 MODULES <br />(N) JUNCTION BOX (TYP.) <br />1410 W RIVER LN <br />UTILITY: SOUTHERN CALIFORNIA <br />EDISON <br />METER #: 222013-192843 <br />AHJ: SANTA ANA CITY (CA) <br />SHEET SIZE: <br />ANSI B <br />17" X 11" <br />LEGACY INSTALLATION SERVICES, LLC <br />3333 DIGITAL DR #600, LEHI, <br />UT 84043, UNITED STATES <br />855-353-4899 <br />dba LGCY ELECTRIC <br />RESERVED FOR ENGINEERING STAMP <br />(IF APPLICABLE) <br />DRAWN BY: <br />ESR <br />DATE: <br /> 26 NOV 2025 <br />DE JESUS GARCIA <br />RESIDENCE <br />1410 W RIVER LN, <br />SANTA ANA <br />CA, 92706 <br />PROJECT ID: LIS53750 <br />SYSTEM SIZE: <br />7310W DC - 11500W AC (6693W CEC AC) <br />MODULES:(17) QCELLS Q.TRON BLK <br />M-G2.H+_003 430 <br />SHEET INDEX: <br />PV-1 - COVER SHEET <br />PV-2 - PROJECT NOTES <br />PV-3 - PROPERTY PLAN <br />PV-4 - SITE PLAN <br />PV-5 - ELEVATION VIEW <br />PV-6 - ATTACHMENT DETAILS <br />PV-7 - THREE LINE DIAGRAM <br />PV-8 - ELECTRICAL CALCS <br />PV-9 - ELEC. LOAD CALC <br />PV-10 - LABELS & PLACARD <br />PV-11 - JOB HAZARD SHEET <br />PV-12 - FIELD CHANGE SHEET <br />PV-13 (+)- DATASHEETS <br /> <br />INVERTER+BATTERY: <br />TESLA POWERWALL 3 1707000-21 <br />INVERTER/W INTEGRATED BATTERY (240V) <br />RSD (S): (6) TESLA MCI-2 <br />RAPID SHUTDOWN DEVICE <br />CONTRACTORS LICENSE #: 1099095 <br />CLASSIFICATION: C-10 ELECTRICAL <br />MARK NIELSON CRAM <br />NCAUTION <br />MULTIPLE SOURCES OF POWER. <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />1410 W RIVER LN, SANTA ANA, CA 92706 <br />1) LOCATED AT JUNCTION BOX, <br />COMBINER BOX <br />CEC 690.13(B) <br />2) LOCATED AT EACH PV DISCONNECTING <br />MEANS <br />CEC 690.13(B) <br />4) LOCATED AT MAIN SERVICE PANEL <br />CFC 605.11.3.1(1) & CEC 690.56(C)(1)(a) <br />SOLAR SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />RAPID SHUTDOWN <br />SWITCH FOR <br />SOLAR PV SYSTEM <br />5) LOCATED AT PV RAPID SHUTDOWN <br />DISCONNECT SWITCH <br />CEC 690.56(C)(2) <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />6) LOCATED AT PRODUCTION METER (IF <br />INSTALLED) <br />CEC 705.12(D)(3) <br />SOLAR PHOTOVOLTAIC <br />PRODUCTION METER <br />!WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT WHEN <br />SOLAR MODULES ARE EXPOSED TO SUNLIGHT <br />8) LOCATED AT EACH DISCONNECTING MEANS FOR <br />PHOTOVOLTAIC OR ESS EQUIPMENT WHERE BOTH <br />SETS OF TERMINALS MAY BE ENERGIZED WHEN THE <br />DISCONNECT IS OPEN <br />CEC 690.13(B) <br />!WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />MULTIPLE POWER <br />SOURCES: UTILITY, <br />PHOTOVOLTAIC SYSTEM <br />9) LOCATED AT POINT OF <br />INTERCONNECTION, LABEL MUST <br />IDENTIFY PHOTOVOLTAIC SYSTEM <br />CEC 705.12(C) & CEC 690.59 <br />!WARNING <br />10) LOCATED AT SOLAR <br />BREAKER <br />(IF APPLICABLE) <br />CEC 705.12(B)(2)(b) <br />PHOTOVOLTAIC <br />SYSTEM <br />DO NOT RELOCATE <br />THIS BREAKER <br />12) LOCATED AT SOLAR <br />COMBINER PANEL (IF APPLICABLE) <br />CEC 690.13(B) <br />!WARNING <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />11) LOCATED AT MAIN <br />SERVICE DISCONNECT <br />CEC 690.13(B) <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />3) LOCATED ON RACEWAYS AND JUNCTION <br />BOXES CONTAINING PV CIRCUITS, SPACED AT <br />MAXIMUM 10 FT OR WHERE SEPARATED BY <br />ENCLOSURES, WALLS, PARTITIONS, CEILINGS, <br />OR FLOORS. <br />REQUIRED FOR DC CIRCUITS BY CEC 690.31(D)(2), <br />REQUESTED BY SOME FDS FOR PV AC CIRCUITS <br />(NON CODIFIED REQUIREMENT) <br />LETTERS AT LEAST 3/8 INCH; WHITE ON RED <br />BACKGROUND; REFLECTIVE. <br />CFC 605.11.1.1 <br />PHOTOVOLTAIC/ESS AC DISCONNECT <br />RATED AC OUTPUT CURRENT: <br />NOMINAL OPERATING <br />AC VOLTAGE: <br />AMPS <br />VOLTS <br />LABELING NOTES: <br />1.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS <br />SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. <br />2.SIGNS SHALL BE OF MATERIALS APPROPRIATE TO THEIR EXPOSURE AND SHALL <br />BE PERMANENTLY ATTACHED. <br />7) LOCATED AT POINT OF <br />INTERCONNECTION AND EACH PV/ESS <br />AC DISCONNECTING MEANS <br />CEC 690.54 <br />240 <br />48.0 <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />PV-10 <br />LABELS & PLACARD <br /> , <br />ENERGY STORAGE SYSTEM <br />BATTERY <br />1 OF 1 <br />LABEL LOCATION: BATTERY AC DISCONNECT <br />SWITCH <br />CEC 706.15(C) <br />ENERGY STORAGE <br />SYSTEM DISCONNECT <br />NOMINAL ESS AC VOLTAGE: 240V <br />MAXIMUM ESS DC VOLTAGE: 600 <br />LOCATED AT MAIN SERVICE PANEL <br />CEC 705.13 <br />THIS SENSOR IS PART OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE OR DISABLE. REPLACE WITH SAME <br />TYPE AND RATING. <br />LOCATED ON CONSUMPTION CTS <br /> BUS BAR PCS BEING UTILIZED. PCS CONTROL WILL <br />LIMIT ALL BACKFEED TO BE NO MORE THAN <br />80% OF THE MAIN SERVICE PANEL BUS RATING. <br />ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE <br />ENERGY SOURCE DISCONNECT NO.DISCONNECT DEVICE <br />UTILITY SERVICE 1 OF 2 100A MAIN BREAKER <br />PV & ESS 2 OF 2 60A AC DISCONNECT SWITCH <br />Proposed New Electrical Only <br />11/26/2025