Laserfiche WebLink
Powerwall 3 Technical Specifications <br />Powerwall 3 Technical Specifications <br />Solar Technical Maximum Solar STC Input <br />Specifications Withstand Voltage <br />PV DC Input Voltage Range <br />Environmental <br />Specifications <br />PV DC MPPT Voltage Range <br />MPPTs <br />20 kW <br />600 V DC <br />60 — 550 V DC <br />60 — 480 V DC <br />6 <br />Maximum Current per MPPT (Imd 15 A7 a <br />Maximum Short Circuit Current per MPPT (Id 19 A 9 <br />'Only applicable to Powerwall 3 units with 15 A IMP on the product label. Otherwise, Powerwall 3 has an IMP of 13 A. <br />a When PV strings are combined on the roof and the DC input current exceeds the MPPT rating, a jumper can be used to <br />combine two MPPTs into a single input to intake DC current up to 30 A IMP / 38 A Isc (or 26 A IMP / 30 A Isc if Powerwall 3 is <br />labeled with 13 A IMP / 15 A Isc). <br />Operating Temperature <br />Operating Humidity (RH) <br />Storage Temperature <br />Maximum Elevation <br />Environment <br />-200C to 500C (-4°F to 122°F) a <br />Up to 100%, condensing <br />-200C to 300C (-40F to 867), up to 95% RH, non - <br />condensing, State of Energy (SOE): 25% initial <br />3000 m (9843 ft) <br />Indoor and outdoor rated <br />Enclosure Rating NEMA 311 <br />Ingress Rating IP67 (Battery & Power Electronics) <br />IP55 (Wiring Compartment) <br />Pnllutinn Ratinn Pril <br />Operating Noise @ 1 m < 50 db(A) typical <br />< 62 db(A) maximum <br />9 Performance may be de -rated at operating temperatures above 40°C (104°F). <br />Compliance Certifications <br />UL 1741, UL 9540, UL 9540A, UL 3741, UL 1741 PCS, <br />Information <br />UL 1741 SA, UL 1741 SB, UL 1741 Multimode, UL 1973, <br />UL 1699B, UL 1998, CSA C22.2 No. 0.8, CSA C22.2 No. <br />107.1, CSA C22.2 No. 330, CSA 22.3 No. 9, IEEE 1547, IEEE <br />1547A, IEEE 1547.1, CA Rule No.21 <br />Grid Connection <br />United States and Canada <br />Emissions <br />FCC Part 15 Class B, ICES 003 <br />Environmental <br />RoHS Directive 2011/65/EU <br />Seismic <br />AC156, IEEE 693-2005 (high) <br />Fire Testing <br />Meets the unit level performance criteria of UL 9540A <br />Mechanical <br />Specifications <br />Dimensions <br />Total Weight of Installed Unit <br />Weight of Powerwall 3 <br />Weight of Glass Front Cover <br />Weight of Wall Bracket <br />1105 x 609 x 193 mm (43.5 <br />132 kg (291.2 lb) <br />124 kg (272.5 lb) <br />6.5 kg (14.5 lb) <br />1.9 kg (4.2 lb) <br />Mounting Options Floor or wall mount <br />i0 These dimensions include the glass front cover being installed on Powerwall 3. <br />1105 mm <br />609 mm <br />0 <br />193 <br />mm <br />2025 Powerwall 3 Datashest 3 2026 Powerwall 3 Detasheet 4 <br />