Laserfiche WebLink
RE <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />CA <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br />OWNER: <br />CECILIO CAMPOS <br />ADDRESS: <br />1746 W RICHLAND AVENUE, UNIT 2 <br />SANTA ANA, CA 92703 <br />SCOPE OF WORK: <br />NEW ATTACHED ADU <br />EDGAR VIDAL <br />RE <br />S <br />T <br />R <br />I <br />C <br />T <br />I <br />V <br />E <br /> <br />NO <br />T <br />I <br />C <br />E <br />: <br /> <br />AL <br />L <br /> <br />DE <br />S <br />I <br />G <br />N <br />S <br />, <br /> <br />ID <br />E <br />A <br />S <br />, <br /> <br />DE <br />T <br />A <br />I <br />L <br />S <br />, <br /> <br />PL <br />A <br />N <br />S <br /> <br />& <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />IN <br />D <br />I <br />C <br />A <br />T <br />E <br />D <br /> <br />BY <br /> <br />TH <br />E <br /> <br />DR <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />AR <br />E <br /> <br />TH <br />E <br /> <br />EX <br />C <br />L <br />U <br />S <br />I <br />V <br />E <br /> <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />OF <br /> <br />DD <br />B <br />, <br />L <br />L <br />C <br />. <br /> <br />TH <br />E <br /> <br />PL <br />A <br />N <br />S <br /> <br />WE <br />R <br />E <br /> <br />CR <br />E <br />A <br />T <br />E <br />D <br /> <br />AN <br />D <br /> <br />DE <br />V <br />E <br />L <br />O <br />P <br />E <br />D <br /> <br />FO <br />R <br /> <br />US <br />E <br /> <br />ON <br /> <br />AN <br />D <br /> <br />IN <br /> <br />CO <br />N <br />J <br />U <br />N <br />C <br />T <br />I <br />O <br />N <br /> <br />WI <br />T <br />H <br /> <br />TH <br />E <br /> <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />DE <br />S <br />C <br />R <br />I <br />B <br />E <br />D <br /> <br />HE <br />R <br />E <br />I <br />N <br />. <br /> <br />NO <br /> <br />PA <br />R <br />T <br /> <br />TH <br />E <br />R <br />E <br />O <br />F <br /> <br />SH <br />A <br />L <br />L <br /> <br />BE <br /> <br />RE <br />P <br />R <br />O <br />D <br />U <br />C <br />E <br />D <br />, <br /> <br />CO <br />P <br />I <br />E <br />D <br />, <br /> <br />AD <br />A <br />P <br />T <br />E <br />D <br />, <br /> <br />MO <br />D <br />I <br />F <br />I <br />E <br />D <br /> <br />OR <br /> <br />DI <br />S <br />T <br />R <br />I <br />B <br />U <br />T <br />E <br />D <br /> <br />TO <br /> <br />OT <br />H <br />E <br />R <br />S <br /> <br />WI <br />T <br />H <br />O <br />U <br />T <br /> <br />PR <br />I <br />O <br />R <br /> <br />WR <br />I <br />T <br />T <br />E <br />N <br /> <br />AN <br />D <br /> <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br /> <br />CO <br />N <br />S <br />E <br />N <br />T <br /> <br />FR <br />O <br />M <br /> <br />DD <br />B <br />, <br /> <br />LL <br />C <br />. <br />PROJECT NOTES <br />A0.1 <br />DATE: <br />ERNESTO ESQUER <br />ERNESTO@DREAMDESIGN.BUILD <br />SCALE: <br />PROJECT DESIGNER: <br />PROJECT COORDINATOR: <br />10/15/2025 <br />AS SHOWN <br />ISABEL GIRALDO <br />ISABEL@DREAMDESIGN.BUILD <br />PRINCIPLE: <br />REVISION: <br />REVISION: <br />1226 W. NINTH ST. <br />UPLAND, CA 91786 <br />310.487.1613 <br />HELLO@DREAMDESIGN.BUILD <br />DREAMDESIGN.BUILD <br />1. AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND <br />UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL DUCT AND <br />OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, <br />PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO REDUCE THE AMOUNT OF WATER, <br />DUST, AND DEBRIS WHICH MAY ENTER THE SYSTEM. <br />2. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND <br />FLOOR FRAMING SHALL NOT BE ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19% MOISTURE <br />CONTENT. INSULATION PRODUCTS WHICH ARE VISIBLE WET OR HAVE HIGH MOISTURE CONTENT <br />SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE IN WALL OR FLOOR CAVITIES. <br />3. ALL MECHANICAL EXHAUST FANS IN ROOMS WITH A BATHTUB OR SHOWER SHALL COMPLY WITH THE <br />FOLLOWING: <br /> - FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMITE OUTSIDE THE <br />BUILDING. <br /> - FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A <br />RELATIVE HUMIDITY RANGE OF < 50% TO A MAXIMUM OF 80% UNLESS FUNCTIONING AS A <br />COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM. <br />4. PROVIDE 72 INCH HIGH NONABSORBENT WALL ADJACENT TO SHOWER, AND APPROVED SHATTER <br />RESISTANT MATERIALS FOR SHOWER. <br />5. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT MATERIALS. <br />6. GLASS ENCLOSURE DOORS MUST BE LABELED CATEGORY II SWING DOOR OUTWARD. <br />7. NET AREA OF SHOWER RECEPTOR NOT LESS THAN 1024 " OR 30" DIA CIR 510, 511, 5406, 5407, UBC <br />STD. T-54 & D.C. 909. <br />8. BATHS WITHOUT OPENABLE WINDOWS SHALL BE PROVIDED WITH VENT FAN CAPABLE OF MINIMUM 5 <br />AIR CHANGES PER HR. <br />9. TOILET COMPARTMENT MINIMUM 30" WIDE WITH 24" CIR. IN FRONT OF TOILET. <br />10. PROVIDE MINIMUM 12" X 12" ACCESS AT TUB TRAP EXCEPT WHERE CONCERNED FIXED <br />CONNECTIONS ARE OF BRASS & WITHOUT SLIP JOINTS. <br />11. PROVIDE MECHANICAL VENTILATION CONNECTED DIRECTLY TO THE OUTSIDE CAPABLE OF <br />PROVIDING FIVE A/P CHANGES PER HOUR IN BATHROOMS, WATER CLOSET COMPARTMENTS, <br />LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OPENABLE WINDOWS ARE NOT PROVIDED <br />12. ONLY LOW CONSUMPTION WATER CLOSETS SHALL BE PROVIDED. "PROVIDE ULTRA FLUSH WATER <br />CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE <br />ADAPTED FOR LOW WATER CONSUMPTION." <br />SITE PREPARATION <br />SITE NOTES <br />SPECIAL HAZARDS <br />MISCELLANEOUS <br />BUILDING CODE NOTES <br />FINISH MATERIAL POLLUTANT CONTROL <br />PLUMBING / BATHROOM NOTES <br />MATERIAL CONSERVATION & RESOURCE EFFICIENCY <br />ADDRESS NOTES <br />CONSTRUCTION WASTE MANAGEMENT PLAN <br />1. THE METHOD OF CLEARING AND STRIPPING SHOULD BE VERIFY BY THE CONTRACTOR. <br /> <br />2. ALL SURFACE VEGETATION, DEBRIS AND STRUCTURES TO BE DEMOLISHED SHALL BE REMOVED <br />FROM THE SITE PRIOR TO COMMENCING SITE PREPARATION, EXCAVATION OR PLACEMENT FILL. <br />3. FILL FOR FLOOR SLABS AND FOUNDATION TRENCHES SHALL CONSIST OF NATIVE SOIL. <br />4. NATIVE SOIL PLACED FOR SLAB SUPPORT SHALL BE PLACED IN LAYERS NOT EXCEEDING 4" WHEN <br />COMPACTED. <br />5. IMPORT FOR SLAB SUPPORT SHALL CONSIST OF SAND, GRAVELY SAND OR SILTY SAND AND SHALL <br />HAVE A EXPANSION INDEX OF LESS THAN 30. <br />1. ALL WORK SHALL COMPLY WITH THE 2024 CALIFORNIA BUILDING CODE, TITLE 24 AND ALL APPLICABLE <br />CODES, REGULATIONS OR REQUIREMENTS OF THE CITY OR COUNTY HAVING JURISDICTION FOR <br />THE PLACE OF THE BUILDING. <br />2. PERMITS SHALL BE OBTAINED FOR FENCES, POOLS, SPA, OR RETAINING WALLS. <br />3. FINAL GRADING WORK SHALL COMPLY WITH 2024 CBC AND SHALL PROVIDE POSITIVE DRAINAGE <br />FROM ALL PARTS OF THE BUILDING AND SHALL NOT DRAIN ONTO ADJACENT PROPERTIES. <br />4. ALL SURFACES SHALL BE SLOPED TO DRAIN WATER AWAY FROM THE BUILDING. <br />5. AT TIME OF PERMIT ISSUANCE, THE CONTRACTOR SHALL SHOW THEIR VALID "WORKERS <br />COMPENSATION" INSURANCE CERTIFICATE. <br />6. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF THE INFORMATION INDICATED ON THESE <br />PLANS. <br />7. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF ALL BUILDINGS AND SHALL BE <br />VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY, SAID NUMBERS SHALL <br />CONTRAST WITH THEIR BACKGROUND. <br />1. ROOF OBSTRUCTIONS SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, RAZOR RIBBON <br />FENCE, CABLE OR OTHER OBSTRUCTIONS SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR <br />EGRESS IN THE EVENT OF FIRE. <br />2. PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS AND <br />PIPING FOR HAZARDOUS MATERIALS THAT ARE EXPOSED TO VEHICULAR DAMAGE LAMC 57.12.02. <br />3. THE INDOOR STORAGE OF COMBUSTIBLE MATERIALS SHALL BE REGULATED IN RELATION TO <br />ARRANGEMENT, LOCATION, SIZE OF AREAS, HEIGHT SEPARATIONS AND HOUSEKEEPING. <br />1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE JOB SITE BEFORE <br />STARTING ANY WORK AND BE RESPONSIBLE FOR THE SAME, THE ARCHITECT SHALL BE NOTIFY OF <br />ANY DISCREPANCIES WHICH MAY EXIST. CONTRACTOR SHALL NOT SCALE ANY DRAWINGS. <br />2. THE SPECIFICATIONS ARE OF A GENERAL NATURE AND MAY REFER TO WORK WHICH IS NOT <br />REQUIRED. THEY ARE NOT INTENDED TO SUPERSEDE ANY CONTRACTUAL AGREEMENT BETWEEN <br />THE OWNER AND THE CONTRACTOR. <br /> <br />3. THE CONTRACTOR SHALL PROVIDE SUPERVISION TO PROPERLY EXECUTE THE PROJECT AND TO <br />PROVIDE ASSURANCE THE WORK IS IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. <br />4. ALL NECESSARY PERMITS SHALL BE SECURED BY THE CONTRACTOR PRIOR TO START ANY <br />CONSTRUCTION. <br />1. ADHESIVE, SEALANTS AND CAULKS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION <br />4.504.2.1 AND COMPLY WITH THE VOC LIMITS IN TABLES 4.504.1 AND 4.504.2 AS APPLICABLE. <br />2. PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.2. <br />AND COMPLY WITH THE VOC LIMITS IN TABLE 4.504.3. <br />3. AEROSOL PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION <br />4.504.2.3 <br />4. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT <br />REQUIREMENTS OF ONE OF HE FOLLOWING: <br /> A. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM OR <br /> B. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHODS FOR THE TESTING OF <br />VOC EMISSIONS (SPEC 01350) OR <br /> C. NSF/ANSI 140 AT THE GOLD LEVEL OR <br /> D. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD <br />5. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF <br />THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. CARPET ADHESIVES SHALL NOT <br />EXCEED A VOC LIMIT OF 50 G/L. (4.504.3.1, 4.504.3.2) <br />6. A MINIMUM OF 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR <br />MORE OF THE FOLLOWING: <br /> A. PRODUCTS CERTIFIED AS A LOW-EMITTING MATERIAL IN THE CHPS HIGH PERFORMANCE <br />PRODUCTS DATABASE OR <br /> B. PRODUCTS CERTIFIED UNDER UL GREEN GUARD GOLD (FORMERLY THE GREEN GUARD <br />CHILDREN & SCHOOLS PROGRAM), OR <br /> C. CERTIFICATION UNDER THE RFCI FLOOR SCORE PROGRAM OR <br /> D. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR THE <br />TESTING OF VOC EMISSIONS (SPEC 01350) <br />7. COMPOSITE WOOD PRODUCTS (HARDWOOD PLYWOOD, PARTICLE BOARD, AND MDF) INSTALLED ON <br />THE INTERIOR OR EXTERIOR OF HE BUILDING SHALL MEET OR EXCEED THE STANDARDS OUTLINED <br />IN TABLE 4.504.5. VERIFICATION OF COMPLIANCE WITH THESE SECTIONS MUST BE PROVIDED AT HE <br />TIME OF INSPECTION. <br />1. ANNUAL SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/ <br />BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS <br />BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHODS. <br />THE NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES) REQUIRES ALL CONSTRUCTION <br />PROJECTS TO PROTECT WATER QUALITY DURING CONSTRUCTION AND REDUCE POLLUTANTS IN STORM <br />WATER RUNOFF THROUGH IMPLEMENTATION AND MAINTENANCE OF BEST MANAGEMENT PRACTICES <br />(BMP): <br />SCHEDULING (ESC-1) MATERIAL DELIVERY AND STORAGE (WM-1) <br />PRESERVATION OF EXISTING VEGETATION (ESC-2) STOCKPILE MANAGEMENT (WM-3) <br />STABILIZED CONSTRUCTION SITE ENTRANCE/EXIT (ESC-24) SPILL PREVENTION AND CONTROL <br />(WM-5) <br />SILT FENCE (ESC-50) SOLID WASTE MANAGEMENT (WM-5) <br />SAND BAG BARRIER (ESC-52) CONCRETE WASTE MANAGEMENT (WM-8) <br />WATER CONSERVATION PRACTICES (NS-1) SANITARY/SEPTIC WASTE <br />MANAGEMENT (WM-9) <br />** JOINTS AND OPENINGS SEC. 4.406.1. OPENINGS IN THE BUILDING ENVELOPE SEPARATING <br />CONDITIONED SPACE FROM UNCONDITIONED SHALL BE SEALED IN ACCORDANCE WITH CALIFORNIA <br />ENERGY CODE REQUIREMENTS. ANNULAR SPACES OR OPENINGS IN THE PLATES AT EXTERIOR WALLS <br />SHALL BE CLOSED WITH CEMENT MORTAR, CONCRETE MASONRY, OR SIMILAR APPROVED METHOD TO <br />PREVENT THE PASSAGE OF RODENTS. <br />1. BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS THAT ARE EITHER ARABIC NUMBERS OR <br />ALPHABETICAL LETTERS. NUMBERS SHALL NOT BE SPELLED OUT AND EACH CHARACTER SHALL <br />NOT BE LESS THAN 4" IN HEIGHT WITH A STROKE WIDTH OF NOT LESS THAN 0.5". THE BUILDING <br />IDENTIFICATION SHALL BE PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE <br />STREET OR ROAD FRONTING THE PROPERTY PER R319.1 <br />1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO <br />ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, <br />VAULTS, PUMPS, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE <br />CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES - WHETHER OR NOT THE <br />LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS <br />AND/OR ADDITIONAL EXPENSES. <br />2. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE <br />DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF <br />THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170, 158) <br />(INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER $10,000) SEPARATE PLUMBING PERMIT IS <br />REQUIRED. <br />3. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN <br />APPROVED SEWAGE DISPOSAL SYSTEM (R306.3) <br />4. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE <br />OUTLES SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED <br />WATER SUPPLY (R306.4) <br />5. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWER HEAD, AND SHOWER <br />COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES <br />SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET AOBVE THE FLOOR (R307.2) <br />6. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER <br />HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. <br />7. PROVIDE 72 INCH HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER- <br />RESISTANT MATERIALS FOR SHOWER ENCLOSURE. (1209.2.3 & 1209.2.4) <br />8. UNIT SKYLIGHTS SHALL BE LABELED BY AN LA CITY APPROVED LABELING AGENCY. SUCH LABEL <br />SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND <br />PERFORMANCE GRADE RATING (RESEARCH REPORT NOT REQUIRED). (R308.6.9) <br /> <br />9. WATER HEATER MUST BE STRAPPED TO WALL (SEC. 507.3, UPC) <br />10. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRWAYS REQUIRES 1-HOUR FIRE RESISTIVE <br />CONSTRUCTION ON ENCLOSED SIDE. <br />11. EXIT DOORWAYS SHALL BE NOT LESS THAN 36" X 6'-8" (WIDTH AND HEIGHT). PROJECTIONS <br />INCLUDING PANIC HARDWARE, SHALL NOT REDUCE THE OPENING TO LESS THAN 32" CLEAR WIDTH. <br />12. PROVIDE 32" WIDE DOORS TO ALL ACCESSIBLE ROOMS WITHIN A DWELLING UNIT. <br />13. PROVIDE WINDOW WELLS (WITH FIXED LADDER) FOR EGRESS WINDOWS BELOW GRADE. <br />14. PROVIDE ACCESS TO THE BOTTOM OF COURT FOR CLEANING PURPOSES. <br />15. COURT MORE THAN TWO STORIES IN HEIGHT SHALL BE PROVIDED WITH A HORIZONTAL AIR INTAKE <br />WITH A MINIMUM AREA OF 10 SQ.FT. <br />16. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN <br />OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR <br />ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000). (R314.6.2) <br /> 16.A.WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING ONE <br />THOUSAND DOLLARS ($1,000), EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE <br />ATTACHED GARAGES OR FUEL BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON <br />MONOXIDE ALARM IN ACCORDANCE WITH SECTIONS R315.1. CARBON MONOXIDE ALARMS <br />SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH <br />THE PERMIT WAS OBTAINED. (R315.2) <br /> 16.B.EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL <br />LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 <br />OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN <br />AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT <br />OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) <br />17. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE <br />AT THE JOB SITE