My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1746 W Richland Ave Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Richland Ave
>
1746 W Richland Ave Unit# 2
>
1746 W Richland Ave Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2026 5:00:09 AM
Creation date
4/29/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101124678
Full Address
1746 W Richland Ave Unit# 2
Street Number
1746
Street Direction
W
Street Name
Richland
Street Suffix
Ave
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
RE <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />CA <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br />OWNER: <br />CECILIO CAMPOS <br />ADDRESS: <br />1746 W RICHLAND AVENUE, UNIT 2 <br />SANTA ANA, CA 92703 <br />SCOPE OF WORK: <br />NEW ATTACHED ADU <br />EDGAR VIDAL <br />RE <br />S <br />T <br />R <br />I <br />C <br />T <br />I <br />V <br />E <br /> <br />NO <br />T <br />I <br />C <br />E <br />: <br /> <br />AL <br />L <br /> <br />DE <br />S <br />I <br />G <br />N <br />S <br />, <br /> <br />ID <br />E <br />A <br />S <br />, <br /> <br />DE <br />T <br />A <br />I <br />L <br />S <br />, <br /> <br />PL <br />A <br />N <br />S <br /> <br />& <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />IN <br />D <br />I <br />C <br />A <br />T <br />E <br />D <br /> <br />BY <br /> <br />TH <br />E <br /> <br />DR <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />AR <br />E <br /> <br />TH <br />E <br /> <br />EX <br />C <br />L <br />U <br />S <br />I <br />V <br />E <br /> <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />OF <br /> <br />DD <br />B <br />, <br />L <br />L <br />C <br />. <br /> <br />TH <br />E <br /> <br />PL <br />A <br />N <br />S <br /> <br />WE <br />R <br />E <br /> <br />CR <br />E <br />A <br />T <br />E <br />D <br /> <br />AN <br />D <br /> <br />DE <br />V <br />E <br />L <br />O <br />P <br />E <br />D <br /> <br />FO <br />R <br /> <br />US <br />E <br /> <br />ON <br /> <br />AN <br />D <br /> <br />IN <br /> <br />CO <br />N <br />J <br />U <br />N <br />C <br />T <br />I <br />O <br />N <br /> <br />WI <br />T <br />H <br /> <br />TH <br />E <br /> <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />DE <br />S <br />C <br />R <br />I <br />B <br />E <br />D <br /> <br />HE <br />R <br />E <br />I <br />N <br />. <br /> <br />NO <br /> <br />PA <br />R <br />T <br /> <br />TH <br />E <br />R <br />E <br />O <br />F <br /> <br />SH <br />A <br />L <br />L <br /> <br />BE <br /> <br />RE <br />P <br />R <br />O <br />D <br />U <br />C <br />E <br />D <br />, <br /> <br />CO <br />P <br />I <br />E <br />D <br />, <br /> <br />AD <br />A <br />P <br />T <br />E <br />D <br />, <br /> <br />MO <br />D <br />I <br />F <br />I <br />E <br />D <br /> <br />OR <br /> <br />DI <br />S <br />T <br />R <br />I <br />B <br />U <br />T <br />E <br />D <br /> <br />TO <br /> <br />OT <br />H <br />E <br />R <br />S <br /> <br />WI <br />T <br />H <br />O <br />U <br />T <br /> <br />PR <br />I <br />O <br />R <br /> <br />WR <br />I <br />T <br />T <br />E <br />N <br /> <br />AN <br />D <br /> <br />SP <br />E <br />C <br />I <br />F <br />I <br />C <br /> <br />CO <br />N <br />S <br />E <br />N <br />T <br /> <br />FR <br />O <br />M <br /> <br />DD <br />B <br />, <br /> <br />LL <br />C <br />. <br />PROPOSED GROUND FLOOR <br />PLAN <br />A3.1 <br />DATE: <br />ERNESTO ESQUER <br />ERNESTO@DREAMDESIGN.BUILD <br />SCALE: <br />PROJECT DESIGNER: <br />PROJECT COORDINATOR: <br />3/19/2026 <br />AS SHOWN <br />ISABEL GIRALDO <br />ISABEL@DREAMDESIGN.BUILD <br />PRINCIPLE: <br />REVISION: <br />REVISION: <br />1226 W. NINTH ST. <br />UPLAND, CA 91786 <br />310.487.1613 <br />HELLO@DREAMDESIGN.BUILD <br />DREAMDESIGN.BUILD <br />N <br />A4.2 <br />S <br />A4.2 <br />W <br />A4.1 E <br />A4.1 <br />5 <br />TE <br />M <br />P <br />. <br />B <br />3 TEMP. <br />B <br />A <br />1 <br />1 <br />2 <br />2 <br />4 <br />F <br />DW <br />F <br />3' <br />- <br />6 <br />" <br />49 <br />' <br />- <br />6 <br />" <br />16 <br />' <br />- <br />9 <br />" <br />19'-7"9'-0"18'-6" <br />47'-1" <br />19 <br />' <br />- <br />7 <br />" <br />9' <br />- <br />9 <br />" <br />20 <br />' <br />- <br />0 <br />" <br />49 <br />' <br />- <br />6 <br />" <br />16 <br />' <br />- <br />9 <br />" <br />5' <br />- <br />1 <br />0 <br />" <br />11 <br />' <br />- <br />2 <br />" <br />5' <br />- <br />7 <br />" <br />11 <br />' <br />- <br />2 <br />" <br />12'-8"16'-3"4'-6"8'-2" <br />41'-6" <br />17 <br />' <br />- <br />2 <br />" <br />14 <br />' <br />- <br />0 <br />" <br />7' <br />- <br />1 <br />0 <br />" <br />10 <br />' <br />- <br />6 <br />" <br />2'-6" <br />9" <br />8' <br />- <br />2 <br />" <br />4' <br />- <br />5 <br />" <br />4' <br />- <br />8 <br />" <br />2' <br />- <br />8 <br />" <br />7' <br />- <br />0 <br />" <br />2' <br />- <br />1 <br />" <br />8' <br />- <br />1 <br />1 <br />" <br />4' <br />- <br />2 <br />" <br />6' <br />- <br />4 <br />" <br />4' <br />- <br />2 <br />" <br />3' <br />- <br />1 <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />4' <br />- <br />1 <br />" <br />2' <br />- <br />9 <br />" <br />1' <br />- <br />3 <br />" <br />1' <br />- <br />8 <br />" <br />7' <br />- <br />6 <br />" <br />4' <br />- <br />2 <br />" <br />8' <br />- <br />7 <br />" <br />1' <br />- <br />8 <br />" <br />8'-7" <br />3' <br />- <br />1 <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />3' <br />- <br />2 <br />" <br />1'-3"1'-3" <br />1 2 <br />(N) TANKLESS <br />WATER HEATER <br />PER T-24. <br />IAQ <br />FAN <br />22"x30" <br />ATTIC <br />ACCESS <br />NOT IN WORK <br />SCOPE <br />22"x30" <br />ATTIC ACCESS <br />MI <br />N <br />I <br />S <br />P <br />L <br />I <br />T <br />MI <br />N <br />I <br />S <br />P <br />L <br />I <br />T <br />MI <br />N <br />I <br />S <br />P <br />L <br />I <br />T <br />BEDROOM <br />AREA: 138 sq ft <br />BEDROOM <br />AREA: 106 sq ft <br />BEDROOM <br />AREA: 145 sq ft <br />OFFICE <br />2-CAR GARAGE <br />FOYER <br />BEDROOM <br />AREA: 159 sq ft <br />BATHROOM <br />CLOSET <br />CLOSET CLOSET <br />BATHROOM <br />BATHROOM <br />CLOSET <br />KITCHEN <br />LIVING <br />DINING <br />BEDROOM <br />AREA: 128 sq ft <br />BATH BEDROOM <br />AREA: 126 sq ft <br />LIVING / KITCHEN <br />AREA: 258 sq ft <br />W.I.C. <br />AREA: 26 sq ft <br />D <br />RG <br />W <br />A-A <br />A7.1 <br />A-A <br />A7.1 <br />B-B <br />A7.1 <br />B-B <br />A7.1 <br />RANGE HOOD <br />280 CFM <br />SD CM <br />SD <br />SD <br />LINEN <br />NATURAL LIGHT CALCULATIONS <br />LIVING AREA <br />REQUIRED <br />MINIMUM <br />PROPOSED <br />TOTAL <br />AREA FACTOR <br />258 SQ. FT.0.08 <br />AMOUNT GLAZING AREA SUB-TOTAL <br />1 6'-0" x 6'-8"40.5 SQ. FT. <br />REQUIRED TOTAL 20.64 SQ. FT. <br />BEDROOM I <br />REQUIRED <br />MINIMUM <br />PROPOSED <br />TOTAL <br />AREA FACTOR <br />126 SQ. FT.0.08 <br />AMOUNT GLAZING AREA SUB-TOTAL <br />PROPOSED TOTAL <br />1 4'-0" x 4'-0"16 SQ. FT. <br />16 SQ. FT. <br />REQUIRED TOTAL 10.08 SQ. FT. <br />PROPOSED TOTAL 40.5 SQ. FT. <br />BEDROOM II <br />REQUIRED <br />MINIMUM <br />PROPOSED <br />TOTAL <br />AREA FACTOR <br />126 SQ. FT.0.08 <br />AMOUNT GLAZING AREA SUB-TOTAL <br />PROPOSED TOTAL <br />1 4'-0" x 4'-0"16 SQ. FT. <br />16 SQ. FT. <br />REQUIRED TOTAL 10.08 SQ. FT. <br />NATURAL VENTILATION CALCULATIONS <br />LIVING AREA <br />REQUIRED <br />MINIMUM <br />PROPOSED <br />TOTAL <br />AREA FACTOR <br />258 SQ. FT.0.04 <br />AMOUNT GLAZING AREA SUB-TOTAL <br />1 6'-0" x 6'-8"20.25 SQ. FT. <br />REQUIRED TOTAL 20.64 SQ. FT. <br />BEDROOM I <br />REQUIRED <br />MINIMUM <br />PROPOSED <br />TOTAL <br />AREA FACTOR <br />126 SQ. FT.0.04 <br />AMOUNT GLAZING AREA SUB-TOTAL <br />PROPOSED TOTAL <br />1 4'-0" x 4'-0"8 SQ. FT. <br />8 SQ. FT. <br />REQUIRED TOTAL 5.04 SQ. FT. <br />PROPOSED TOTAL 20.25 SQ. FT. <br />BEDROOM II <br />REQUIRED <br />MINIMUM <br />PROPOSED <br />TOTAL <br />AREA FACTOR <br />126 SQ. FT.0.04 <br />AMOUNT GLAZING AREA SUB-TOTAL <br />PROPOSED TOTAL <br />1 4'-0" x 4'-0"8 SQ. FT. <br />8 SQ. FT. <br />REQUIRED TOTAL 5.04 SQ. FT. <br /> ID A B <br />DIMENSIONS (W x H)3'-0"×1'-0"4'-0"×4'-0" <br />TYPE SLIDING SLIDING <br />COATING LOW-E LOW-E <br />PANES DOUBLE DOUBLE <br />HEADER HEIGHT 6'-8"6'-8" <br />SILL HEIGHT 5'-8"2'-8" <br />TEMPERED <br />FIRE-RATING <br />SHGC 0.23 0.23 <br />U-FACTOR 0.3 0.3 <br />QUANTITY 1 2 <br />WINDOW SCHEDULE <br /> ID 1 2 3 4 5 <br />DIMENSIONS (W x H)2'-8"×6'-8"3'-0"×6'-8"6'-0"×6'-8"5'-0"×6'-8"7'-0"×6'-8" <br />FUNCTION PASSAGE PASSAGE LAUNDRY ENTRY <br />MATERIAL HOLLOW CORE HOLLOW CORE ALUM / GLASS HOLLOW CORE ALUM / GLASS <br />PANES N/A N/A DOUBLE SINGLE DOUBLE <br />NOTES <br />QUANTITY 2 2 1 1 1 <br />DOOR SCHEDULE <br />PROPOSED GROUND FLOOR PLAN 1/4" = 1'-0" <br />1. ANY GLASS IN DOORS OR IN SIDELIGHT(S) WITHIN 24" OF <br />EITHER DOOR EDGE PER 2022 CBC, SEC. 2406.4(6) OR <br />WITHIN 40" OF ANY LOCKING MECHANISM (PER <br />APPLICABLE LOCAL ORDINANCE) SHALL BE FULLY <br />TEMPERED. <br />2. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL <br />ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION <br />RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE <br />WITH ENERGY CALCULATIONS. <br />1" MAX THRESHOLD TO LANDING BELOW <br />EXISTING WALL <br />TO BE DEMO <br />EXISTING RETAINING WALL <br />SD <br />UL 217 COMPLIANT PHOTOELECTRIC SMOKE <br />DETECTOR – HARD WIRED 110 VOLTS. <br />INTERCONNECTED W/ BATTERY BACK-UP. <br />CM <br />NEW FRAME WALLS W/ STUDS @ 16" O.C. <br />5/8" DRYWALL @ INTERIOR & <br />7/8" STUCCO @ EXTERIOR <br />NEW FRAME WALLS W/ STUDS @ 16" O.C. <br />5/8" DRYWALL @ INTERIOR & EXTERIOR <br />UL 2034/2075 COMPLIANT CARBON MONOXIDE <br />ALARM – HARD WIRED 110 VOLTS. <br />INTERCONNECTED W/ BATTERY BACK-UP. <br />SYMBOL LEGEND <br />GLASS NOTES <br />SHOWER AREA: 12.5 SQ. FT. <br />SHOWER/TUB WALLS SHALL BE CEMENT PLASTER, <br />TILE OR APPROVED EQUAL TO 72" ABOVE DRAIN <br />1 <br />KEYNOTES <br />AGING IN PLACE GRAB BAR REINFORCEMENT <br />SEE DETAILS 1-2 /A6.22 <br />RECESSED VENTILATION FAN // MIN. 50 C.F.M. <br />ENERGY STAR COMPLIANT & HUMIDITY CONTROLLED. <br />VENTED TO OUTSIDE <br />KITCHEN RANGE HOOD // MIN. 280 C.F.M. <br />VENTED TO OUTSIDE <br />NEW 1HR FIRE RATED INTERIOR WALL <br />SEE DETAIL 3/A8.1 <br />POWER REQUIREMENTS <br />A DEDICATED 240-VOLT BRANCH CIRCUIT MUST BE <br />INSTALLED WITHIN 3 FEET FROM THE DESIGNATED SPACE: <br />◊ WITH A 30 AMPS MINIMUM RATING <br />◊ WITH THE BLANK COVER LABELED “240V READY” <br />A SPACE MUST BE RESERVED ON THE MAIN ELECTRICAL <br />SERVICE PANEL TO ALLOW FOR THE INSTALLATION OF A <br />DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE HEAT PUMP <br />WATER HEATER (HPWH) INSTALLATION AND PERMANENTLY <br />LABELED “FOR FUTURE 240V USE.” <br />PLUMBING CONFIGURATION <br />EITHER A DEDICATED COLD WATER SUPPLY MUST BE <br />INSTALLED OR THE COLD WATER SUPPLY MUST BE ROUTED <br />THROUGH THE DESIGNATED HPWH LOCATION JUST BEFORE <br />REACHING THE GAS OR PROPANE WATER HEATER. <br />THE HOT WATER SUPPLY PIPE COMING OUT OF THE GAS OR <br />PROPANE WATER HEATER MUST BE ROUTED THROUGH THE <br />DESIGNATED HPWH LOCATION BEFORE SERVING ANY <br />FIXTURES. <br /> HOT AND COLD WATER PIPING MUST BE EXPOSED AND <br />READILY ACCESSIBLE AT THE DESIGNATED HPWH LOCATION <br />FOR FUTURE INSTALLATION OF A HPWH. <br /> HEAT PUMP WATER HEATER READY REQUIREMENTS
The URL can be used to link to this page
Your browser does not support the video tag.