Laserfiche WebLink
WATER CUT-OFF MASTIC <br />PRE-MOLDED PIPE <br />FLASHING <br />FASTENER AND <br />FASTENING <br />HOT AIR WELD <br />PVC ROOFING <br />ROOF DECK <br />NOTE 3 <br />STAINLESS <br />STEEL CLAMPING <br />RING INCLUDED <br />NOTES: <br />1. REMOVE ALL LEAD AND OTHER FLASHING. <br />2. TEMPERATURE OF PIPE MUST NOT EXCEED 120° F. <br />3. PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE, REGARDLESS OF PIPE DIAMETER. <br />4. INSTALL 3 FASTENERS AND PLATES AROUND PIPE EQUALLY SPACE. FASTENERS MAY <br />ALSO BE POSITIONED MAXIMUM 12" FROM PIPE, FASTENED 12" ON CENTER AND <br />FLASHED WITH REINFORCED MEMBRANE. <br />5. IF PLATES CANNOT BE INSTALLED AS SHOWN THEY CAN BE POSITIONED OUTSIDE THE <br />PIPE FLASHING FLANGE AND FLASHED WITH 6" WIDE REINFORCED MEMBRANE. <br />6. PIPE FLASHING DECK FLANGE MUST BE HOT AIR WELDED A MINIMUM OF 1-1/2" BEYOND <br />FASTENING PLATES. <br />ROOF UNDERLAYMENT <br />STRUCTURE <br />RIGID INSULATION <br />CMU. WALL <br />GALV. MTL COUNTER <br />FLASHING <br />STEP FLASHING <br />PVC MEMBRANE ADHESIVE <br />ROOF STRUCTURE <br />MODIFIED BITUMEN MEMBRANE <br />CANT STRIP <br />R-30 RIDGED INSULATION <br />SEALANT <br />7" <br />DENS GLASS <br />CONTINOUS METAL <br />HOOK STRIP (MIN. 22 <br />GAUGE) @ 6" O.C. <br />METAL EXTENDER <br />PIECE AS REQUIRED <br />SHEET METAL COPING <br />CAP WITH WATERTIGHT <br />JOINTS <br />WOOD NAILER, ACCOMPLISH 5% <br />MIN. SLOPE <br />GROMMETTED FASTENER <br />5% MIN. SLOPE <br />COVER BOARD <br />POLYMER-MODIFIED <br />BITUMEN BASE SHEET <br />MEMBRANE <br />STRIPPING SHEET <br />APPROX. 4" <br />POLYMER-MODIFIED BITUMEN <br />CAP SHEET <br />COMPATIBLE ROOF CEMENT OR <br />COMPATIBLE SEALANT AT <br />FLASHING TO MEMBRANE <br />JUNCTURE <br />SHEET-METAL FLASHING <br />SHEET-METAL RAIN COLLAR <br />DRAWBAND <br />POLYURETHANE SEALANT <br />SEALANT <br />4" MIN. FLANGE SET IN <br />COMPATIBLE ROOF MASTIC; <br />PRIME FLANGE BEFORE <br />STRIPPING <br />METAL LINER AND INSULATION <br />8" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />FL <br />A <br />S <br />H <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />(E) ROOF DECK <br />RIGID INSULATION <br />APPROX. 6" <br />GRIND TO BARE METAL AND <br />PRIME PRIOR TO FLASHING <br />INSTALLATION <br />6" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />FL <br />A <br />S <br />H <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />LIQUID APPLIED <br />REINFORCED FLASHING <br />SEAL AROUND <br />PENETRATION WITH <br />COMPATIBLE SEALANT <br />R-30 INSULATION AND <br />COVER BOARD <br />ROOF DECK <br />PIPE OR DUCT <br />PENETRATION, EXTEND <br />OR PROVIDE NEW PIPE <br />IF REQUIRED <br />SEALANT (SEE NOTE) <br />STAINLESS STEEL HOSE CLAMP <br />ALUMINUM TAPE (SEE NOTE) <br />FLASHING MEMBRANE <br />PVC MEMBRANE <br />NOTES: <br />1. MINIMUM TAPE IS REQUIRED IF EXISTING PENETRATION IS CONTAMINATED. <br />2. SEALANT IS A MAINTENANCE ITEM, MAINTENANCE MAY NOT COVERED UNDER <br />WARRANTY. <br />3. VAPOR BARRIER SHALL BE SEALED AT EDGES. <br />8" <br /> <br />M <br />I <br />N <br />. <br />STRUCTURAL DECK <br />0' <br /> <br />- <br /> <br />1 <br /> <br />1 <br />/ <br />4 <br />" <br />R-30 RIGID <br />INSULATION <br />STRUCTURAL DECK <br />PVC MEMBRANE OVER 1/4" <br />DENSDECK <br />HOT STACK, VIF <br />STAINLESS STEEL <br />HOSE CLAMP <br />RAIN COLLAR WITH HIGH <br />TEMPERATURE SEALANT <br />METAL CURB AS REQ'D <br />FIBERGLASS BATTEN <br />PVC FLASHING MEMBRANE <br />FASTENER PLATES AND <br />SCREWS <br />PVC BASE FLASHING, HOT AIR <br />WELDED <br />NOTES: <br />1. PVC MEMBRANE SHALL NOT BE IN CONTACT WITH SURFACES HAVING <br />SUSTAINED TEMPERATURES ABOVE 160°F. <br />2. APPROXIMATELY 1/8" DIAMETER BEAD OF CUT-EDGE SEALANT IS <br />REQUIRED ON CUT EDGES OF REINFORCED MEMBRANE. <br />RIDGED <br />INSULATION <br />EXTERIOR <br />PLASTER <br />ROOF DECK <br />PVC MEMBRANE <br />FULLY ADHERED PER <br />MANUFACTURE <br />DENS GLASS <br />RIDGID INSULATION <br />PVC 8" DETAIL STRIP <br />WITH CONTINUOUS <br />WELD <br />24 GAUGE FLASHING <br />2X FIBER CEMENT <br />FASCIA <br />EXHAUST EQUIPMENT <br />20" GAUGE SHEET METAL <br />FLASHING WITH 5% <br />SLOPE <br />2" <br />BUILT UP ROOFING <br />MI <br />N <br />. <br /> <br /> <br />8 <br />" <br />CANT <br />2x NAILER <br />R-30 RIGID INSULATION <br />2x6 REDWOOD <br />NAILER <br />PLYWOOD AS REQUIRED <br />STRUCTURE <br />DENS GLASS <br />2x BLOCKING <br />1/2" PLYWOOD <br />CMU. WALL <br />GALV. MTL COUNTER <br />FLASHING <br />STEP FLASHING <br />PVC MEMBRANE ADHESIVE <br />ROOF STRUCTURE <br />MODIFIED BITUMEN MEMBRANE <br />CANT STRIP <br />R-30 RIDGED INSULATION <br />SEALANT <br />7" <br />DENS GLASS <br />CONTINOUS METAL <br />HOOK STRIP (MIN. 22 <br />GAUGE) @ 6" O.C. <br />METAL EXTENDER <br />PIECE AS REQUIRED <br />SHEET METAL COPING <br />CAP WITH WATERTIGHT <br />JOINTS WOOD NAILER, ACCOMPLISH 5% <br />MIN. SLOPE <br />GROMMETTED FASTENER <br />5% MIN. SLOPE <br />GALV. MTL COUNTER <br />FLASHING <br />STEP FLASHING <br />PVC MEMBRANE <br />ADHESIVE <br />ROOF STRUCTURE <br />MODIFIED BITUMEN <br />MEMBRANE <br />CANT STRIP <br />R-30 RIDGED INSULATION <br />SEALANT <br />7" <br />DENS GLASS <br />DECK <br />TAPERED RIGID INSULATION <br />COVER BOARD <br />TOP PLY APP CAP SHEETWALL <br />CANT <br />STRIP <br />ALPHALT <br />PRIMER <br />2 PLIES APP <br />MEMBRANE <br />APP CAP <br />SHEET <br />METAL <br />SIDING <br />FASTEN 12" O.C. W/ APPROVED FASTENERS <br />3 COURSING (OPTIONAL) <br />FASTENERS WITH 1" <br />MIN. DIAMETER PLATE <br />6" O.C. AT TOP EDGE <br />6" MIN..2" <br />8" <br /> <br />M <br />I <br />N <br />. <br /> <br />B <br />A <br />S <br />E <br /> <br />FL <br />A <br />S <br />H <br />I <br />N <br />G <br />HEAT WELD <br />BITUMEN <br />NOTE: THIS CONDITION OCCURS EXISTING EXTERIOR CEMENT PLASTER ASSEMBLY. <br />USE SMACNA STANDARD DETAIL FOR COUNTER FLASHING REGLETS. <br />SMACNA <br />STANDARDS FOR <br />COUNTER FLASHING <br />PS-25-2401 <br />CITY OF SANTA ANA <br />PUBLIC WORKS AGENCY <br />REVISIONS REFERENCES <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 ELEV.: 176.00 (2010) <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />SHEET OF <br />1511 Cota Ave. Long Beach, <br />CA 90813 Tel. 562-912-7900 <br />Architecture <br />Government Services <br />Edward <br />Lok Ng <br />C-16840 <br />REN.11/30/25 <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />DRAWNDESIGNED:CHECKED: <br />UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA <br />811 <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE <br />BEFORE EXCAVATING. THE CONTRACTOR SHALL VERIFY THE <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />UNDERGROUND SERVICES ALERT. DIAL 811 <br />LOK NG: <br />REVIEWED FOR <br />CONSTRUCTABLITY: <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />ARCHITECT <br />INSTALLED <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />FILE NO: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />PRINCIPAL CIVIL ENGINEER RCE NO.:G: <br />\ <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />3 <br />1 <br />3 <br />9 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />P <br />o <br />r <br />t <br />o <br />l <br />a <br /> <br />P <br />a <br />r <br />k <br /> <br />R <br />e <br />s <br />t <br />o <br />o <br />m <br />R <br />e <br />n <br />o <br />v <br /> <br />& <br /> <br />A <br />d <br />d <br /> <br />f <br />o <br />r <br /> <br />D <br />V <br />D <br />\ <br />0 <br />1 <br />- <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />0 <br />1 <br />- <br />R <br />e <br />v <br />i <br />t <br />\ <br />3 <br />- <br />C <br />D <br />\ <br />3 <br />1 <br />3 <br />9 <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />P <br />o <br />r <br />t <br />o <br />l <br />a <br /> <br />P <br />a <br />r <br />k <br /> <br />R <br />e <br />s <br />t <br />r <br />o <br />o <br />m <br /> <br />R <br />e <br />n <br />o <br /> <br />& <br /> <br />A <br />d <br />d <br /> <br />C <br />D <br />. <br />r <br />v <br />t <br />A5.2 <br />PORTOLA PARK <br />SPLASH PAD <br />ROOF DETAILS <br />LALA LOK <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />-24 <br />0 <br />1 <br />4PIPE FLASHING <br />2WALL FLASHING A <br />9PENETRATION (FIELD WRAP) <br />8PIPE PENETRATION <br />12PIPE/DUCT PENETRATION <br />5HEATED STACK FLASH'G1 <br />6DRIP EDGE 3FLASHING AT EXHAUST VENT <br />1WALL FLASHING B <br />SCALE:12" = 1'-0"11WALL BASE FLASHING <br />NUMBER DATE INITALS DESCRIPTION APPROVED <br />SHEET 36 OF 57