GENERAL NOTES <br />1.ALL CONDUITS SHALL BE INSTALLED IN THE CEILING BELOW <br />U.O.N. <br />2.REFER TO MECHANICAL AND PLUMBING PLANS FOR THE <br />EXACT LOCATION OF HVAC EQUIPMENT AND ADDITIONAL <br />WIRING REQUIREMENTS. <br />3.ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE NEMA <br />3R. <br />4.ALL EXTERIOR RECEPTACLE OUTLETS SHALL BE GFCI <br />TYPE. <br />5.COORDINATE LIGHT FIXTURE LOCATIONS AND LIGHT <br />SWITCH LOCATIONS, COLOR, AND STYLE WITH ARCHITECT. <br />6.WHERE MOTION SENSORS ARE SHOWN ON PLANS, VERIFY <br />WATTAGE AND COVERAGE OF PRODUCT PROVIDED IS <br />ADEQUATE FOR SPACE TO BE CONTROLLED. COVERAGE IS <br />TO BE ADJUSTED TO AVOID ACCIDENTAL ACTIVATION <br />OUTSIDE OF AREA. VERIFY WIRING REQUIREMENTS TO <br />MOTION SENSORS, RELAY PACKS, ETC WITH PRODUCT <br />BEING PROVIDED. <br />KEY NOTES <br />1.ROUTE CIRCUIT THRU LCP. <br />2.CONTRACTOR IS TO CIRCUIT WATER HEATERS BACK TO <br />PANEL 'SPA' BEING PROVIDED UNDER SEPARATE CONTRACT. <br />PROVIDE (1)30A/2P CIRCUIT BREAKERS WITH LOCK OFF <br />CAPABILITY. PROVIDE (2)#10 (1)#10G 3/4"C BRANCH CIRCUIT. <br />3.PROVIDE NEMA 3R MOTOR RATED SNAP SWITCH FOR <br />DISCONNECTING MEANS. <br /># <br />FD <br />(NEW)LCP(EX)PANEL 'A' <br />A-27 <br />A-30 <br />(EX)MAIN SERVICE <br />A-10 <br />SPA-24,26 <br />SPA-28,30(EX)PANEL 'SPA' <br />2 <br />2 <br />EF <br />1 <br />(ON ROOF) <br />A-29 <br />3 <br />FD <br />A-17 <br />A-17 <br />A-17 <br />A-17 A-17 <br />A-17 <br />A-18 <br />A-18 <br />A-18 <br />A-18 <br />1 <br />TYP <br />L2 <br />32 <br />TYP <br />A-18A-18A-18 <br />A-18 A-18 <br />A-18A-18 <br />L1 <br />52 <br />TYP <br />298 TENNESSEE STREET <br />REDLANDS, CA 92373 <br />P: (909) 281-8100 <br />E: svela@velaengineering.biz <br />X <br />SAMUEL VELA <br />PS- <br />X <br />X <br />- <br />X <br />X <br />X <br />X <br />CITY OF SANTA ANA <br />PUBLIC WORKS AGENCY <br />REVISIONS REFERENCES <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 ELEV.: 176.00 (2010) <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />SHEET OF <br />DRAWN:DESIGNED:CHECKED: <br />UNDERGROUND SERVICE ALERT OF SOUTHERN <br />CALIFORNIA <br />811 <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE <br />BEFORE EXCAVATING. THE CONTRACTOR SHALL VERIFY THE <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />UNDERGROUND SERVICES ALERT. DIAL 811 <br />REVIEWED FOR <br />CONSTRUCTABLITY: <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />ARCHITECT <br />INSTALLED <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />FILE NO: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />PORTOLA PARK <br />SPLASH PAD <br />NUMBER DATE INITALS DESCRIPTION APPROVED <br />POWER FLOOR PLAN <br />SCLE:1/4" = 1'-0"1 LIGHTING FLOOR PLAN <br />SCLE:1/4" = 1'-0"2 <br />POWER AND LIGHTING FLOOR PLANS E1.1 <br />N N <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />SHEET 50 OF 57