Laserfiche WebLink
FD <br />FD <br />FD <br />FD <br />KEY MAP <br />N.T.S.PORTOLA AVEN <br />EXISTING PARKING LOT <br />L-301 <br />0 10'5'20' <br />Scale: 1" = 10'-0" <br />N <br />CONSTRUCTION PLAN <br />NUMBER DATE INITIALS DESCRIPTION <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />CITY OF SANTA ANA <br />FILE NO.: <br />INSTALLEDAPPROVED <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />REFERENCES <br />PUBLIC WORKS AGENCY <br />XRCE NO.: <br />ELEV.: 176.00 (2010) <br />REVISIONS <br />SHEET OF <br />BENCHMARK DESCRIPTION: <br />OCS BM SA-253-70 <br />FD 3 3/4" OCS ALUMINUM BENCH MARK DISK STAMPED "SA-253-70", SET IN NW'LY CORNER OF A 3.5FT X 16FT <br />CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE NE'LY CORNER OF THE INTERSECTION OF GRAND AVE <br />AND SANTA CLARA AVE, 87FT N'LY OF THE CENTERLINE OF SANTA CLARA AVE AND 39FT E'LY OF THE CENTERLINE <br />OF GRAND AVE. MONUMENT IS SET LEVEL WITH THE SIDEWALK <br />PORTOLA PARK <br />SPLASH PADREVIEWED FOR <br />CONSTRUCTABLITY: <br />PRINCIPAL CIVIL ENGINEER <br />DESIGNED: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />ES MM ES <br />LANDSCAPE ARCHITECT <br />DRAWN:CHECKED: <br />PS- <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />GARY VASQUEZ <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />811 <br />UNDERGROUND SERVICE ALERT. DIAL 811 <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA <br />11/26/25 <br />LICENSED LANDSCAPE ARCHITECT <br />SIGNATUREGARY M. VASQUEZ #3883 <br />DATE <br />RENEWAL DATE <br />02/2027 <br />AINROFILACFOETATS <br />DVDCreative <br />151 Kalmus Drive, Suite M8 <br />Costa Mesa, CA 92626 <br />714.641.1300 <br />dvdcreative.com <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />TURF REPAIR SEE <br />CONSTRUCTION <br />SCHEDULE SHEET <br />L-300B <br />TURF REPAIR SEE <br />CONSTRUCTION <br />SCHEDULE SHEET <br />L-300B <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />CO-101 CO-101 <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />CO-101 <br />CO-101 <br />CO-103 <br />CO-103 <br />CO-103 <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />CO-104 <br />CO-105 <br />CO-106 <br />CO-107 <br />CO-110 F-101 <br />F-101 <br />F-101 <br />P-101 <br />P-101 <br />P-102 <br />P-102 <br />P-102 <br />P-104 <br />P-104 <br />P-104 <br />P-103 <br />P-103 <br />P-103 <br />S-102 <br />S-103 <br />SB-101 <br />SB-102 <br />SB-103 <br />SB-103 <br />SB-103 <br />SP-101 <br />SP-108 <br />SP-109 <br /> TYP. OF 2 <br />SP-102 <br /> TYP. OF 2 <br />SP-103 <br />SP-104 <br /> TYP. OF 2 <br />SP-105 TYP. OF 2 <br />SP-106 <br />SP-107 <br /> TYP. OF 2 <br />CONTRACTOR TO COMPLETE DEFERRED SUBMITTAL ITEMS INCLUDING SHADE <br />STRUCTURES AND SPLASH PAD PLAY ELEMENTS. SUBMIT MANUFACTURER'S <br />DRAWINGS, DETAILS, AND STRUCTURAL CALCULATIONS FOR SHADE <br />STRUCTURE, SHADE STRUCTURE FOOTINGS, AND SPLASH PAD EQUIPMENT <br />FOOTINGS FOR CITY REVIEW AND APPROVAL. <br />NOTES <br />CO-103 <br />ALIGN AND MATCH <br />ELEVATIONS AT EX. <br />S-105 <br />REFER TO SHEET L-100 FOR GENERAL NOTES <br />1 <br />L-632 <br />OUTDOOR SHOWER <br />S-101 <br />2 <br />L-632 <br />DO NOT DRINK SIGN <br />S-104 <br />2 <br />L-633 <br />PRECAST LEAF BENCH (95") <br />S-102 <br />1 <br />L-633 <br />PRECAST LEAF BENCH (66") <br />S-103 <br />CO-108 <br />TURF REPAIR SEE <br />CONSTRUCTION <br />SCHEDULE SHEET <br />L-300B <br />S-106 <br />CODE DESCRIPTION <br />COORDINATION NOTES <br />EXISTING PAVING <br />EXISTING UTILITY TYP. <br />EXISTING LIGHT POLE TYP. <br />EXISTING FLAG POLE <br />EXISTING SITE FURNISHINGS <br />RAIN DIVERTER <br />SPLASH PAD SURGE CHAMBER <br />SPLASH PAD EQUIPMENT <br />DRAIN TYP. <br />DRAIN AT SHOWER <br />CO-101 <br />CO-102 <br />CO-103 <br />CO-104 <br />CO-105 <br />CO-106 <br />CO-107 <br />CO-108 <br />CO-109 <br />CO-110 <br />CODE DESCRIPTION <br />PAVING <br />PCC PEDESTRIAN PAVEMENT (4" <br />THK.) <br />PCC SPLASH PAD PAVEMENT (6" <br />THK.) <br />INTEGRAL COLOR PCC SPLASH <br />PAD PAVEMENT (6" THK.) <br />INTEGRAL COLOR PCC SPLASH <br />PAD PAVEMENT (6" THK.) <br />PCC VEHICULAR PAVEMENT (6" <br />THK.) <br />P-101 <br />P-102 <br />P-103 <br />P-104 <br />P-105 <br />CODE DESCRIPTION <br />FENCE <br />STEEL COLD ROLLED FENCE ( 6' <br />HT.) <br />F-101 <br />CODE DESCRIPTION <br />SITE BUILDING <br />RESTROOM AND SPLASH PAD <br />MAINTENANCE BUILDING <br />EXPANSION <br />CANTILEVER SINGLE POLE <br />PYRAMID FABRIC SHADE <br />STRUCTURE <br />JOINED HYPAR SAILS FABRIC <br />SHADE STRUCTURE <br />CODE DESCRIPTION <br />SPLASH PAD <br />VERSOSPLASH <br />FUNNEL TWIST <br />JUNIOR WATER JEWEL <br />MINI PILLAR <br />ROOSTER SPRAY <br />SEA CRAWLER <br />STREAM JET <br />AQUAVATOR <br />CUSTOM COLLECTOR BOX <br />SB-101 <br />SB-102 <br />SB-103 <br />SP-101 <br />SP-102 <br />SP-103 <br />SP-104 <br />SP-105 <br />SP-106 <br />SP-107 <br />SP-108 <br />SP-109 <br />CODE DESCRIPTION <br />SITE FURNISHINGS <br />OUTDOOR SHOWER <br />PRECAST LEAF BENCH (95") <br />PRECAST LEAF BENCH (66") <br />DO NOT DRINK SIGN <br />NO ACCESS SIGN <br />HOURS OF OPERATION SIGN <br />S-101 <br />S-102 <br />S-103 <br />S-104 <br />S-105 <br />S-106 <br />CO-109 <br />P-102 <br />P-102 <br />1.ALL TREES TO HAVE CONSTRUCTION FENCE <br />THAT MAXIMIZES THE TREE PROTECTION ZONE <br />AND TO THE DRIPLINE AS INDICATED ON PLAN. <br />SEE DETAIL 1, THIS SHEET. <br />2.ANY TRENCHING WITHIN THE TREE <br />PROTECTION ZONE WILL BE DONE BY HAND OR <br />BY JACKING AND BORING. <br />3.NO GRADING OTHER THAN FINE GRADING TO <br />BE DONE WITHIN THE TREE PROTECTION ZONE. <br />4.NO EQUIPMENT IS TO BE OPERATED OR <br />PARKED UNDER A TREE, NOR ARE ANY <br />MATERIALS TO BE STORED WITHIN THE TREE <br />PROTECTION ZONE. <br />5.IRRIGATION MAINLINE SHALL NOT BE <br />INSTALLED WITHIN THE TREE PROTECTION <br />ZONE. JACK AND BORE SLEEVES UNDER TREE <br />ROOTS. <br />6.CHEMICAL HERBICIDES SHALL NOT BE USED <br />WITHIN 10 FT. OF TREE'S DRIPLINE. <br />7.DO NOT NAIL OR STAPLE MATERIALS OR SIGNS <br />TO TREES. <br />8.FERTILIZE & WATER TO MINIMIZE SHOCK AS <br />DIRECTED BY CITY ENGINEER AND CITY <br />ARBORIST. <br />9.PROVIDE BERM AS NEEDED, NO CLOSER THAN <br />DRIP LINE. <br />10.DURING CONSTRUCTION, TREES SHALL BE <br />MONITORED TO MITIGATE SHOCK SYMPTOMS IF <br />THEY OCCUR. NOTIFY THE CITY ENGINEER AND <br />CITY ARBORIST. <br />11.THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR THE PROTECTION AND MAINTENANCE OF <br />ALL TREES ON SITE. THE CONTRACTOR SHALL <br />BE RESPONSIBLE FOR WATERING TREES AND <br />WASHING DUST OFF FOLIAGE AS NEEDED. <br />12.TREES DAMAGED OR DAMAGED BY THE <br />CONTRACTOR'S OR SUB-CONTRACTOR'S <br />OPERATIONS AND OR LACK OF PROTECTION <br />AND MAINTENANCE WILL BE REPLACED AT THE <br />CONTRACTORS SOLE EXPENSE. REPLACEMENT <br />SPECIES SHALL BE SELECTED BY THE CITY <br />ENGINEER AND SHALL BE A MINIMUM OF A 36" <br />BOX TREE. <br />TREE PROTECTION NOTES <br />PRUNING MAY BE NECESSARY TO FACILITATE THE <br />REMOVAL OF DEAD WOOD, CONFLICTS WITH NEW <br />STRUCTURES, OR REDUCE STRESS AND SHALL BE <br />CARRIED OUT UNDER THE SUPERVISION OF THE CITY <br />PROVIDED QUALIFIED ARBORIST. <br />BORING OF UTILITY LINES IN TREE <br />PROTECTION ZONE IS PREFERRED TO <br />TRENCHING. DEPTH OF BORING TO BE <br />COORDINATED WITH CITY ARBORIST. <br />PROJECT ARBORIST SHALL BE PRESENT DURING TRENCHING AND <br />EXCAVATION WITHIN 10 FEET OF THE TREE DRIP ZONES. <br />CONTACT CITY ENGINEER TO COORDINATE ARBORIST'S SITE <br />VISITS. <br />1.DO NOT CUT ROOTS GREATER THAN 2" IN DIAMETER OR <br />LESS THAN 18" RADIAL DISTANCE FROM BASE OF THE <br />TRUNK WITHOUT NOTIFYING THE PROJECT ARBORIST <br />FIRST. <br />2.ALL CUTS OF ROOTS SHALL BE CLEAN CUT AND DRESSED <br />PER PROJECT ARBORISTS DIRECTION. <br />3.BACKFILL AS SOON AS POSSIBLE TO AVOID ROOTS FROM <br />DRYING. DO NOT LEAVE ROOTS EXPOSED FOR MORE THAN <br />24 HOURS. PROTECT ROOTS FROM SUNLIGHT. <br />DR <br />I <br />P <br /> <br />L <br />I <br />N <br />E <br />TR <br />E <br />E <br />PR <br />O <br />T <br />E <br />C <br />T <br />I <br />O <br />N <br />ZO <br />N <br />E <br />TR <br />E <br />E <br />PR <br />O <br />T <br />E <br />C <br />T <br />I <br />O <br />N <br />ZO <br />N <br />E <br />DR <br />I <br />P <br /> <br />L <br />I <br />N <br />E <br />6" TO 8" ORGANIC BARK MULCH WITHIN TREE PROTECTION ZONE. <br />INSTALL ORGANIC BARK MULCH 6" AWAY FROM TRUNK OF TREE. <br />FENCE AT PERIMETER OF TREE PROTECTION ZONE. 6' CHAINLINK FOR <br />ALL TREES NOT LOCATED ON SLOPES. 3' ORANGE SNOW FENCE FOR ALL <br />TREES ON SLOPES. FENCING MUST BE DONE PRIOR TO ANY SITE DEMO <br />OR STAGING NEAR TREES TO BE PRESERVED. <br />1 NTSTREE PROTECTION <br />CO-102 <br />ALIGN AND MATCH <br />ELEVATIONS AT EX. <br />TURF REPAIR SEE <br />CONSTRUCTION <br />SCHEDULE SHEET <br />L-300B <br />P-105 <br />P-105 <br />CODE DESCRIPTION <br />GATE <br />DOUBLE GATE (8' WIDE X 6' HT.)G-101 <br />LIMIT <br /> <br />O <br />F <br />WORK <br />EXISTING <br />RESIDENTIAL <br />LIM <br />I <br />T <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />RESTROOM <br />AND SPLASH <br />PAD <br />BUILDING <br />LIMIT O <br />F <br />WORK <br />EXISTING <br />BALLFIELD <br />LIM <br />I <br />T <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />1 <br />L-620 <br />STEEL COLD ROLLED <br />FENCE (6' HT.) <br />F-101 <br />G-101 <br />(1) 2" SEWER VENT PIPE. LOCATE LESS THAN <br />8' FROM P-TRAP. VENT PIPE TO BE BLACK. <br />PERMANENTLY ATTACH TO SHADE <br />STRUCTURE POST. TOP OF VENT TO BE 10' <br />OVER FINISH SURFACE. <br />CO-102 <br />ALIGN AND MATCH <br />ELEVATIONS AT EX. <br />DOWELED ISOLATION JOINT @ <br />EXISTING <br />3 <br />L-600 <br />9 57