20173729 - Permit
PBA
>
Building
>
Permits
>
R
>
Roosevelt Ave
>
4310 W Roosevelt Ave
>
20173729 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2021 10:21:08 AM
Creation date
9/16/2021 10:21:04 AM
Metadata
Fields
Template:
Permit
Permit Number
20173729
Full Address
4310 W Roosevelt Ave
Permit ID
276796
Master ID Number
2021-167298
Project Name
Miscellaneous Counter1 Permit
Street Number
004310
Street Direction
W
Street Name
Roosevelt
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
7/7/2021
Issued Date
7/7/2021
Finalized Date
8/10/2021
Flood Zone
A-0602320143J
Description of Work
Electrical for new roof mounted solar PV system. ALL SOLAR FEES PAID ON 101107153
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTTS FoR STANDAI{D STITIN(I SYSTEM ELECTTIICAL DIACRAM <br />Notes for One-Line Standard Eleclrical <br />Diagram for Single-Phase PV Systems <br />System AC Srze <br />Srte Address <br />Site Name <br />oG*i By James lvlccarron <br />NTS Date <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />MoDULE MAKE ,HANWhA Q.CELLS <br />MOOULE MODEL O,PeaK DIJO BLK.G6+ 340 <br />MAx PowER-PotNT CURRENT 0qp) .10.02 A <br />MAX POWER.POINT VOLTAGE iVvP) .305,46 V <br />opEN-crRCUrr VoLTAGE (vD.) .396.'13 v <br />sHoRT-crRcurr CURRENT 0sL) 10-52 A <br />MAx sERrEs FUsE (ocPo) 13 A <br />MAXTMUM PowER (Pe) 340 w <br />MAx VoLTAGE (TYP 6oovoc) 600 v <br />, Voc rEMP coEFF (mV t'c] oI 'ht'c E) -O.262 <br />IF COEFF SUPPLIED CIRCLE UNITS <br />NOTES FOR ALL DRAWNGS <br />OCPD = OVERCURRENT PROTECTION OEVICE <br />NATIONAL ELECTRICAL CODE' REFERENCES <br />sHow! As ltvEc )oo(xx) <br />INVERTER RATINGS (Gurde Section 4) <br />. rruvenren unxe <br />. <br />Tesla <br />TNVERTER MoDEL 7.6 kW <br />MAx DC voLr RATTNG .600 v <br />MAX PowER @,{o"c . 7600 w <br />NoMTNAL AC vorrAGE .240 v <br />MAx AC CURRENT 28 A <br />MAx ocpD RATTNG 35 A <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />PHOTOVOLTAIC POWER SOURCE <br />RATEO MPP CURRENT . 5,19 A <br />RATED Mpp voLTAcE 786.8 v <br />MAx sYsrEM VoLTAGE 1040.42 v <br />MAX CIRCUIT CURRENT 5 59 A <br />WARNING: ELECIRICAL SHOCK <br />HAZARD-LINE AND LOAO MAY BE <br />ENERGIZED IN OPEN POSITION <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (IF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE <br />28 <br />240 <br />NOIES FOR ARRAY CIRCUIT WIRING (Gurde Seclon 6 and I and Ap9€ndr D) <br />1) <br />EX <br />LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />TREME ORY sULA TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION, LOWEST EXPECTED AMEIENT TEMP , "C <br />NOTES FOR INVERTER CIRCUITS (Gude SecIIon E and 9) <br />IHIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />2.) HIGHEST CONTINUOUS AMEIENT TEMPERATURE EASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE EOR ASHRAE LOCAIION MOST SIMILAR TO <br />INSTALLATION LOCATION HIGHEST CONTINUOUS TEMPERATURE a 'C <br />2 ) 2OO5 ASHRAE FUNOEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47'C IN THE UNITED STATES (PALM SPRINGS, CA IS 44,1"C) FOR LESS THAN 9 <br />CURRENT.CARRYING CONDUCTORS IN ROOF.MOUNTEO SUNLIT CONDUIT AT <br />LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47"C OR LESS (ALL OF UNITEO STATES), <br />a) 12 aWG 90'C CONDUCTORS ARE GENERALLY ACCEPTABI-E FOR MODULES <br />WTH llc OF 7.68 AMPS OR LESS vvtIEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE, <br />b) 1O AV\6 gOOC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />v\/IfH ls oF I 6 AMPS oR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER <br />FUSE, <br />1) IF UTILITY REOUIRES A VISIBLE-BREAK SWTCH, DOES THIS SWTCH MEET IHE <br />REOUIREMENT" YESI NO E] N/AE <br />2) IF GENERATION METER REQUIRED. DOES THIS METER SOCKET MEET THE <br />REOUIREMENT? YES D NO tr N/A I <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (OC) CONDUC-ORS BASED ON MAX <br />CURRENT ON NEC 8SO 53 SIGN OR OCPO RATING AI DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUII (AC) CONOUCTORS ACCORDING TO INVERTER <br />OCPO AMPERE RATING (Scr Gudc S.cion 9) <br />5) TOTAL OF D INVERTER OCPD(!) ONE FOR EACH INVERTER OOES TOTAL <br />suppLy BRErREFS coMoLy wrH 120% BUSBAR ExcEpIoN rN 690.84(8)(2xa)? <br />YES E NOtr <br />F <br />Uc <br />i- <br />f- <br />! <br />\
The URL can be used to link to this page
Your browser does not support the video tag.