My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1661 E St Andrew Pl - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Andrew Pl
>
1661 E St Andrew Pl
>
1661 E St Andrew Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2026 5:00:21 AM
Creation date
5/1/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20188145
101126797
Full Address
1661 E St Andrew Pl
Street Number
1661
Street Direction
E
Street Name
St Andrew
Street Suffix
Pl
Text box
ID:
1
Creator:
Import Agent
Created:
5/1/2026 5:00 AM
Modified:
4/30/2026 3:16 PM
Text:
The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.
ID:
2
Creator:
Import Agent
Created:
5/1/2026 5:00 AM
Modified:
4/30/2026 3:16 PM
Text:
BLDG#:101126797 ELEC: 20188145 APPROVALS: PLNG: FArias BLDG: JLo ELEC: MSmith
Stamp
ID:
1
Creator:
Import Agent
Created:
5/1/2026 5:00 AM
Modified:
4/30/2026 3:16 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
COVER PAGE <br />SHEET TITLE <br />SHEET NUMBER <br />STAMP <br />PV1.0 (TITLE) <br />A2/2/2026FOR REVIEW <br />REVDATEDESCRIPTION <br />REVISIONS <br />24"X36" <br />16 <br />6 <br />1 <br /> <br />E <br />16 <br />6 <br />1 <br /> <br />E <br /> <br />S <br />T <br /> <br />A <br />N <br />D <br />R <br />E <br />W <br /> <br />P <br />L <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />AH <br />J <br />: <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />PR <br />O <br />J <br />E <br />C <br />T <br />358 Coral Circle, El Segundo, CA 90245 <br />Ben Lochtenberg <br />CSLB C10 License # 992157 <br />Phone No: (310) 376-8740 <br />DRAWN BY <br />A. CRUZ <br />PROJECT ENGINEER <br />ENGINEERING@XEROSOLAR.COM <br />SCOPE OF WORK: <br />(55) PV MODULES (LONGI LR5-72HBD-545M) <br />SYSTEM SIZE: (29.975) kW DC STC, (27.069) <br />kW AC CEC <br />(1) SOL-ARK 60K-3P-480V INVERTER <br />INSTALLATION MANUAL(S) TO WHICH THE EQUIPMENT HAS BEEN LISTED, INCLUDING <br />PROJECT DESCRIPTION: <br />A ROOF MOUNTED SOLAR SYSTEM TO BE INSTALLED ON THE COMMERCIAL BUILDING BUILDING IN SANTA ANA 92705 <br />THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING <br />ON SITE ELECTRICAL EQUIPMENT VIA A BACK-FED BREAKER IN AN EXISTING BREAKOUT PANEL <br />PV1.0 <br />(TITLE) <br />1 VICINITY MAP <br />SCALE: NTS <br />APPLICABLE CODES <br />2025 CALIFORNIA BUILDING CODE <br />2025 CALIFORNIA ELECTRIC CODE <br />2025 CALIFORNIA MECHANICAL CODE <br />2025 CALIFORNIA PLUMBING CODE <br />2025 CALIFORNIA FIRE CODE <br />2025 BUILDING ENERGY EFFICIENCY STANDARDS <br />ADDITIONALLY, CONFORM TO ALL LOCAL <br />ORDINANCES AND REQUIREMENTS <br />2025 SANTA ANA MUNI CODE <br />2025 CALIFORNIA GREEN BUILDING STANDARD <br />CODE <br />CALIFORNIA ENERGY CODE <br />CALIFORNIA EXISTING BUILDING CODE, WITH <br />LATEST REVISIONS <br />ARRAY LOCATION <br />INDEX <br />INDEX NO.DESCRIPTION <br />PV-1.0 TITLE PAGE <br />PV-1.1 CONSTRUCTION NOTES <br />PV-2.0 PLOT PLAN <br />PV-2.1 PV ROOF LAYOUT <br />PV-2.2 ATTACHMENT LAYOUT <br />PV-2.3 STRINGING LAYOUT <br />PV-3.0 ATTACHMENT DETAILS <br />PV-4.0 SINGLE LINE DIAGRAM <br />PV-5.0 SIGNAGE AND ELEVATION <br />PV-6.0 SPEC SHEETS <br />PV-6.1 SPEC SHEETS <br />PV-6.2 SPEC SHEETS <br />PV1.0 <br />(TITLE) <br />2 AERIAL MAP <br />SCALE: NTS ARRAY LOCATION <br />AHJ DESIGN NOTES <br />·ELECTRICAL EQUIPMENT WILL NOT <br />ENCROACH ZONING SET BACK. <br />·FIRE SET BACKS ARE MEASURED FROM <br />THE EXTERIOR LOAD BEARING WALL. <br />·LADDER ACCESS POINT SHALL NOT BE <br />MARKED ABOVE EXTERIOR WALL <br />OPENING. <br />·ALL WORK SHALL BE IN COMPLIANCE <br />WITH THE MOST CURRENT SANTA ANA <br />CODES <br />A. GENERAL <br />1. ALL WORK ON THIS PROJECT SHALL BE PERFORMED IN COMPLIANCE WITH ALL <br />LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS, THE AHJ APPROVED <br />DRAWINGS, IFC DRAWINGS, INSTALLATION MANUALS, MATERIAL SPECIFICATION <br />SHEETS, AND ENVIRONMENTAL, HEALTH, SAFETY (EHS), AND QUALITY <br />REQUIREMENTS, AS APPLICABLE TO EACH CONTRACTORS SCOPE OF WORK. <br />2. CONTRACTORS', AND CONTRACTORS' EMPLOYEES, SHALL BE DULY LICENSED AND <br />CERTIFIED TO PERFORM THEIR SCOPE OF WORK REQUIRED TO BUILD AND <br />COMPLETE THIS PROJECT. <br />3. SEE DIAGRAMS AND DETAILS FOR SITE SPECIFIC INFORMATION. <br />4. THIS PROPOSED PHOTOVOLTAIC SYSTEM IS INTENDED TO CONNECT TO THE <br />EXISTING SITE OR FACILITY ELECTRICAL SYSTEM. THIS CONNECTION SHALL BE IN <br />COMPLIANCE WITH NEC ARTICLE 705.12 "POINT OF CONNECTION" (POC). <br />5. THIS PROPOSED PHOTOVOLTAIC SYSTEM IS INTENDED TO BE OPERATED IN <br />PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A <br />REQUIREMENT OF UL 1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE <br />SYSTEM WHEN THE UTILITY GRID IS NOT OPERATIONAL. <br />6. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED FOR THEIR <br />INTENDED USE AND INSTALLED PER MANUFACTURER SPECIFICATIONS. <br />7. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. <br />8. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ON THE <br />DRAWINGS, AND LAYOUT ALL AREAS OF THE ARRAY PRIOR TO ANY INSTALLATION <br />WORK IN ORDER TO VERIFY THAT NO DISCREPANCIES, EXISTING CONDITIONS, <br />OBSTRUCTIONS OR SHADING EXIST. IF EITHER EXIST, CONTRACTOR SHALL SUBMIT A <br />RFI TO THE ENGINEER AND INSTALLATION WORK SHALL NOT COMMENCE UNTIL <br />FORMAL DIRECTION IS RECEIVED. <br />9. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK AS INDICATED ON THE <br />DRAWINGS AND SPECIFICATIONS. <br />10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING <br />ANY EXISTING UTILITIES AND EQUIPMENT ENCOUNTERED IN THE WORK AREAS. <br />11. THE CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH EQUIPMENT AND <br />INSTALLERS. <br />12. THE CONTRACTOR SHALL HAVE ALL SWITCHES AND BREAKERS IN THE "OFF" <br />POSITION PRIOR TO RECEIVING PERMISSION TO OPERATE WITH THE EXCEPTION OF <br />WHEN CONDUCTING APPROVED AND CODE COMPLIANT TESTING AND <br />COMMISSIONING. <br />13. PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL <br />INSPECTIONS AND APPROVALS ARE OBTAINED. <br />14. ALL MECHANICAL HARDWARE SHALL BE CORROSION RESISTANT APPROPRIATE <br />FOR SITE CONDITIONS. <br />15. ALL CONNECTIONS SHALL BE TORQUED PER MANUFACTURER SPECIFICATIONS. IF <br />SNUG TIGHT, THEN FOLLOW MANUFACTURER RECOMMENDATIONS. PROVIDE <br />PERMANENT TORQUE/WITNESS MARKS ON ALL STRUCTURAL, MECHANICAL, AND <br />ELECTRICAL TERMINATING HARDWARE WITH RED PERMANENT PAINT PEN FOR <br />INSPECTION. REMARK TO BE BLUE PERMANENT PAINT PEN. <br />B. PRE-CONSTRUCTION MEETING <br />1. NO CONTRACTOR SHALL BEGIN CONSTRUCTION WITHOUT FIRST ATTENDING A <br />PRE-CONSTRUCTION MEETING COVERING THE FOLLOWING TOPICS: <br />A. CONTRACTOR'S SCOPE OF WORK <br />B. SITE SPECIFIC EHS PLAN REVIEW <br />C. AHJ APPROVED DRAWINGS <br />D. IFC DRAWINGS REVIEW <br />E. SITE SPECIFIC QUALITY, TESTING, AND COMMISSIONING PLAN REVIEW <br />F. OTHER PROJECT SITE REQUIREMENTS <br />N <br />W <br />S <br />E <br />N <br />W <br />S <br />E <br />SCOPE OF WORK: <br />SOLAR MODULES DC SYSTEM: <br />(55) PV MODULES (LONGI LR5-72HBD-545M) <br />(TOTAL: 1512.68 SQ. FT.) <br />SYSTEM SIZE: (29.975) kW DC STC, (27.069) kW AC CEC <br />(55) AP SMART RSD-S-PLC RAPID SHUT DOWN DEVICES, UL LISTED, <br />CEC 690.12 AND SUNSPEC COMPLIANT <br />(1) AP SMART TRANSMITTER OUTDOOR KIT, NEMA 3R, UL LISTED <br />INVERTER AC SYSTEM: <br />(1) SOL-ARK 60K-3P-480V INVERTER, UL 1741 LISTED <br />(1) AP SMART PLC TRANSMITTER, RSD INITIATION DEVICE, <br />CEC690.15 AND SUNSPEC COMPLIANT <br />(1) NON-FUSED PV AC DISCONNECT,480/277V, 100A, UL LISTED, <br />NEMA 3R <br />ATTACHMENTS AND RAILS: <br />(86) ATTACHMENT POINTS @ 60" O.C. FIRE RATED AND TESTED <br />(1) IRONRIDGE XR100 RACKING SYSTEM <br />DESIGN CRITERIA <br />WIND SPEED: 94MPH <br />SNOW LOAD: 3PSF <br />EXPOSURE B <br />RISK CATEGORY II <br />HIGH DESIGN TEMPERATURE =35.7°C <br />LOW DESIGN TEMPERATURE = 4.4 °C <br />OCCUPANCY GROUP: <br />WAREHOUSE F-1 <br />ADMIN AREA: B <br />CONSTRUCTION TYPE: TYPE V-B (FULLY <br />SPRINKLERED)
The URL can be used to link to this page
Your browser does not support the video tag.