My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1701 E St Andrews Pl - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Andrew Pl
>
1701 E St Andrew Pl
>
1701 E St Andrews Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2026 5:00:19 AM
Creation date
5/1/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101126855
Full Address
1701 E St Andrew Pl
Street Number
1701
Street Direction
E
Street Name
St Andrew
Street Suffix
Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STATE OF CALIFORNIA <br />Mechanical Systems CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: Orange County Credit Union TI Report Page: (Page 6 of 10) <br />Date Prepared: 2025-10-14T13:44:46-04:00 <br />Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220101 <br />Compliance ID: 336887-1025-0003 <br />Report Generated: 2025-10-14 10:44:55 <br />I. SYSTEM CONTROLS <br />This table is used to demonstrate compliance with mandatory controls in 110.2 and 120.2 and prescriptive controls in 140.4(f) and (n), 170.2(c)4D 170.2(c)4L or requirements in <br />141.0(b)2E 180.2(b)2 for altered space conditioning systems. <br />01 02 03 04 05 06 07 08 09 10 <br />System Name System <br />Zoning <br />Conditione <br />d Floor <br />Area Being <br />Served <br />(ft2) <br />Thermostats <br />110.2(b) & (c)1, <br />120.2(a) 160.3(a)2A or <br />141.0(b)2E & 180.2(b)2 <br />Shut-Off <br />Controls <br />120.2(e) & <br />160.3(a)2D <br />Isolation <br />Zone <br />Controls <br />120.2(g) & <br />160.3(a)2F <br />Demand Response <br />110.12 120.2(b) & <br />160.3(a)2B <br />Supply Air <br />Temp. <br />Reset <br />140.4(f) & <br />170.2(c)4D <br />Window Interlocks per <br />140.4(n) & 170.2(c)4D <br />Direct Digital Control <br />(DDC) per 120.2 <br />RTU-2 Controls <br />Multi-zone <br />w/ DDC to <br />zone <br />NA: <br />Altered per <br />141.0(b)2E <br />EMCS EMCS EMCS EMCS Included NA: Alteration Project Provided <br />1FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non-central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to <br />have setback thermostats. <br />J. VENTILATION AND INDOOR AIR QUALITY <br />This table is used to demonstrate compliance with mandatory ventilation requirements in 120.1 120.2(e)3B 140.4(p) and 140.4(q) for all nonresidential and hotel/motel and <br />d:t24refnolink/]160.2, 160.3(a)3D, 170.2(a)4N, 170.2(a)4O for high-rise residential occupancies. For alterations, only ventilation systems being altered within the scope of the permit <br />application need to be documented in this table. In lieu of this table, the required outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented <br />in a spreadsheet. <br />01 Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table. <br />02 Check this box if the project included Nonresidential, Hotel/Motel Spaces or Multifamily Common Use Spaces <br />03 Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per 120.1(c)2. <br />K. TERMINAL BOX CONTROLS <br />This section does not apply to this project.
The URL can be used to link to this page
Your browser does not support the video tag.