Laserfiche WebLink
2C3 <br />SHEET #:REVISION: <br />SHEET TITLE: <br />REV.DATE DESCRIPTION <br />ISSUED FOR CONSTRUCTION <br />REVISIONS <br />APPROVED BY: <br />CHECKED BY: <br />DRAWN BY: <br />CW <br />MEW <br />FIN <br />PROJECT INFORMATION: <br />LA02330A <br />2235 WEST STANFORD STREET <br />SANTA ANA, CA 92704 <br />THE INFORMATION CONTAINED IN THIS <br />SET OF DOCUMENTS IS PROPRIETARY BY <br />NATURE. ANY USE OR DISCLOSURE <br />OTHER THAN THAT WHICH RELATES TO <br />THE CLIENT IS STRICTLY PROHIBITED. <br />1200 CONCORD AVENUE <br />CONCORD, CA 94520 <br />PREPARED FOR: <br />RMobileT <br />0 12/12/25 <br />A&E FIRM: <br />1355 WINDWARD CONCOURSE, SUITE 410 <br />ALPHARETTA, GA 30005 <br />TEL: 678-990-2338 <br />ISSUED FOR CONSTRUCTION101/14/26 <br />ADDRESS JDX COMMENTS204/15/26 <br />NO <br />R <br />T <br />H <br />NEW EQUIPMENT PLAN <br />SCALE: 3/8" = 1'-0" <br />EXISTING EQUIPMENT PLAN <br />SCALE: 3/8" = 1'-0" <br />NO <br />R <br />T <br />H <br />EXISTING & NEW <br />EQUIPMENT PLANS <br />NOTE: <br />ESS IS COMPLIANT WITH CFC 1207.5.1 <br />FOR SIZE AND SEPARATION. <br />NOTE: <br />THE POWER DESIGN FOR ANY AC ELECTRICAL POWER <br />CHANGES IS TO BE PERFORMED BY OTHERS AND IS SHOWN <br />HERE FOR REFERENCE PURPOSES ONLY. T-MOBILE IS <br />SOLELY RESPONSIBLE FOR THE ELECTRICAL POWER DESIGN. <br />BATTERY LOADING IN EXISTING BATTERY CABINET: <br />·(12) EXISTING LEAD-ACID BATTERIES = 12 * (123 lb) = 1476 lb <br />·(8) NEW LITHIUM-ION BATTERIES = 8 * (91 lb) = 728 lb <br />·THE PROPOSED LOADING IS 49% OF THE EXISTING LOADING <br />THEREFORE THE EXISTING BATTERY CABINET IS ADEQUATE <br />NOTES: <br />·REMOVE THE (12) EXISTING VALVE-REGULATED LEAD-ACID <br />BATTERIES IN THE EXISTING B160 BATTERY CABINET. <br />·INSTALL (8) NEW ERICSSON 6624 LITHIUM-ION BATTERIES <br />IN THE EXISTING B160 BATTERY CABINET. <br />1'-1"5" <br />5" <br />8" <br />8" <br />3' <br />- <br />5 <br />" <br />5' <br />- <br />4 <br />" <br />(E) T-MOBILE <br />RBS CABINET <br />(E) T-MOBILE <br />GPS ANTENNA <br />(E) T-MOBILE RAISED <br />EQUIPMENTS PAD <br />(E) ALUMINUM <br />FENCE <br />(E) T-MOBILE <br />CONCRETE PAD <br />(E) MONOPOLE <br />(E) ACCESS <br />GATE <br />(E) T-MOBILE <br />CIENA BOX <br />(TYP) <br />(E) T-MOBILE <br />UTILITY H-FRAME <br />(TYP) <br />(E) GRAVEL <br />SURFACE AREA <br />(E) T-MOBILE <br />SERVICE LIGHT <br />(E) T-MOBILE <br />EQUIPMENT (TYP) <br />(E) T-MOBILE <br />EQUIPMENT <br />(E) HANDHOLE <br />(TYP) <br />EXISTING T-MOBILE <br />VALVE-REGULATED <br />LEAD-ACID (VRLA) BATTERIES <br />TO BE REPLACED (12 TOTAL) <br />(E) T-MOBILE RAISED <br />EQUIPMENT PAD <br />10' SETBACK <br />FROM BATTERY <br />CABINET <br />(E) PARKING <br />(TYP) <br />(E) APPROXIMATE LOCATION <br />OF PROPERTY LINE <br />(TYP) <br />(P) ERICSSON 6624 <br />LITHIUM-ION <br />BATTERIES (8 TOTAL) <br />(E) TOWER <br />FOUNDATION PAD <br />(E) T-MOBILE <br />DISCONNECT <br />1'-1"5" <br />5" <br />8" <br />8" <br />3' <br />- <br />5 <br />" <br />5' <br />- <br />4 <br />" <br />(E) T-MOBILE <br />6160 RADIO <br />CABINET <br />(E) T-MOBILE <br />B160 BATTERY <br />CABINET(E) T-MOBILE <br />RBS CABINET <br />(E) T-MOBILE <br />GPS ANTENNA <br />(E) T-MOBILE RAISED <br />EQUIPMENTS PAD <br />(E) ALUMINUM <br />FENCE <br />(E) T-MOBILE <br />CONCRETE PAD <br />(E) MONOPOLE <br />(E) ACCESS <br />GATE <br />(E) T-MOBILE <br />CIENA BOX <br />(TYP) <br />(E) T-MOBILE <br />UTILITY H-FRAME <br />(TYP) <br />(E) GRAVEL <br />SURFACE AREA <br />(E) T-MOBILE <br />SERVICE LIGHT <br />(E) T-MOBILE <br />EQUIPMENT (TYP) <br />(E) HANDHOLE <br />(TYP) <br />(E) T-MOBILE RAISED <br />EQUIPMENT PAD <br />10' SETBACK <br />FROM BATTERY <br />CABINET <br />(E) PARKING <br />(TYP) <br />(E) APPROXIMATE LOCATION <br />OF PROPERTY LINE <br />(TYP) <br />(E) TOWER <br />FOUNDATION PAD <br />(E) T-MOBILE <br />DISCONNECT <br />(E) T-MOBILE <br />6160 RADIO <br />CABINET <br />(E) T-MOBILE <br />B160 BATTERY <br />CABINET <br />(E) T-MOBILE <br />EQUIPMENT <br />04/15/26 <br />s<s<.J-b.J-b,,.a=,,.a=--------