My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1133 S Austin St & Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Austin St
>
1133 S Austin St
>
1133 S Austin St & Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 5:00:22 AM
Creation date
5/6/2026 5:00:07 AM
Metadata
Fields
Template:
Plan
Permit Number
101121509
101121510
Full Address
1133 S Austin St
1133 S Austin St Unit# 2
Street Number
1133
Street Direction
S
Street Name
Austin
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 4 <br /> <br />Based on the State of California SEISMIC HAZARD ZONES Map, Newport Beach <br />Quadrangle, the subject site is located within a potential liquefaction zone. Therefore, the <br />owner(s) of this property should be aware of the risks associated with the potential <br />liquefaction such as structural distress due to the potential differential settlement caused <br />by the potential liquefaction. <br /> <br />A detailed liquefaction study with a 50 ft deep test hole has been performed. <br /> <br />Liquefaction Analysis <br /> <br />The provisions of the Special Publication 117A [SP117A], “Guidelines For Evaluating <br />and Mitigating Seismic Hazards In California”, Published in 2008 by the State of <br />California, Department of Conservation, Division of Mines and Geology have been <br />followed. <br /> <br />A 50 ft. deep boring was drilled by using a hollow stem flight auger drill rig. The <br />approximate location of the boring is depicted on the attached Site Plan/Geotechnical <br />Map. The geotechnical log of the boring is included in Appendix B. <br /> <br />As the boring was advanced, relatively undisturbed soil samples were secured at selected <br />depth intervals using a steel tube sampler lined with I-inch-high, thin wall brass rings. <br />The sampler was driven into the undisturbed earth materials using a standard 140 pound <br />"automatic-trip" steel hammer freely dropped 30-inches. Standard Penetration Testing <br />(SPT) was also performed at selected depth intervals; a bulk sample of near ground <br />surface earth materials was secured from the drill cuttings. The approximate sample <br />depths are noted on the boring log. The samples were transported our laboratory for <br />testing. After completion of sampling, the boring was backfilled with the drill cuttings. <br /> <br />Moisture content and dry density testing was performed on the "undisturbed" ring <br />samples. Moisture content testing was performed on the SPT samples. Atterberg Limits <br />(i.e., liquid limit, plastic limit, and plasticity index) tests were performed on cohesive <br />soils. The test results are included in Appendix C. Note: To determine if fine- <br />grained/clayey soils are susceptible to liquefaction, the screening criteria of SP117A were <br />used: Clayey soils having Plasticity Index (PI) smaller than 12 and moisture content <br />greater than 85% of the Liquid Limit (LL) are susceptible to liquefaction. Therefore, the <br />percentage of soil finer than 0.075 mm by washing the soil through the N 200 sieve in <br />accordance with ASTM Test Method D 1140, Atterberg Limits (LL, PL, PI) and in-situ <br />moisture contents were determined on selected samples; and the test results are included <br />in our Laboratory Test Results and/or Boring Log. <br /> <br />A copy of the computer print-outs of the results of our liquefaction analysis using the <br />computer program prepared by CivilTech software is included in Appendix E. <br /> <br />Based on the results of our liquefaction analysis, the calculated total and differential <br />settlements due to liquefaction are 3.94 and 1.971 to 2.602 inches, respectively. <br />
The URL can be used to link to this page
Your browser does not support the video tag.