My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1133 S Austin St & Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Austin St
>
1133 S Austin St
>
1133 S Austin St & Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 5:00:22 AM
Creation date
5/6/2026 5:00:07 AM
Metadata
Fields
Template:
Plan
Permit Number
101121509
101121510
Full Address
1133 S Austin St
1133 S Austin St Unit# 2
Street Number
1133
Street Direction
S
Street Name
Austin
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HOANG DAN PHAM, P.E HD ENGINEERING CONSTRUCTION 3/5/2024 <br />Risk Category of Building:II Per ASCE7-16 Table 1.5-1 <br />3-Second Gust Wind Speed (mph):PS30 =110 Per ASCE 7-16, Figure 26.5-1A <br />Exposure Category C Per ASCE 7-16, Section 26.7.3 <br />Topographic factor KZt=1.0 Per ASCE 7-16, Section 26.8 <br />Building Height & Exposure, Adjustment Factor: <br />Per ASCE 7-16 Mean Ht.0 to 15'15' to 20'20' to 25'25' to 30'30' to 35' <br />Figure 28.6-1 Adj. Fac.1.00 1.00 1.00 1.00 1.05 <br />Use Mean Roof Height of:11.0 ft < Least Horizontal Dimension OK <br />Adjustment Factor:λ =1.00 <br />Edge Strip and End Zones: <br />Building Eave Height:8.0 ft <br />Least Horizontal Dimension (Width):34.5 ft <br />Edge Strip (a):3.2 ft <br />10% of least horizontal dimension:3.45 ft <br />40% of building eave height:3.2 ft <br />4% of least horizontal dimension:1.4 ft <br />Or 3' minimum required:3.0 ft <br />End Zone Width (2a):6.4 ft <br />Longest Horizontal Dimension (Length):42.0 ft <br />Building Roof Pitch/ Roof Angle (Transverse - Y)4 :12 18.4 Deg. < 45 OK <br />Building Roof Pitch/ Roof Angle (Longgitudinal - X)4 :12 <br />Number of story:1 <br />Roof Top Plate (ft):8.0 ft <br />Wind Roof Height (ft):Transverse - Y =13.5 ft Longitudinal - X =11.0 ft <br />Design Wind Pressure for MWFRS:PS = l KZt IW PS30 <br />Slope Angle A B C D <br />4 to 12 18.4 26.6 -7 17.7 -3.9 <br />Wind Presure (psf)Transverse - Y Wind Presure (psf)Longitudinal - X <br />End Wall End Roof Int. Wall Int. Roof End Wall End Roof Int. Wall Int. Roof <br />26.60 -7.00 17.70 -3.90 26.60 26.60 17.70 17.70 <br />Minimum Design Wind Load ( Section 28.4.4 ASCE 7-10) : 16.00 psf <br />Wind Load (plf)Transverse - Y Wind Load (plf)Longitudinal - X <br />End Wall End Roof Int. Wall Int. Roof End Wall End Roof Int. Wall Int. Roof <br />212.80 -38.50 141.60 -21.45 212.80 28.32 141.60 26.55 <br />Wind Load (lbs)Transverse - Y Wind Load (lbs)Longitudinal - X <br />W(+) end W(+) int.W(+) roof W(+) total W(+) end W(+) int.W(+) roof W(+) total <br />1362 5041 -1010 5393 1362 3979 927 6268 <br />0.6W 3236 3761 <br />Per ASCE 7-16, PART 2 Section 28.5 Simplified Design <br />WIND LOADS ANALYSIS - ADDITION <br />L-6
The URL can be used to link to this page
Your browser does not support the video tag.