My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1133 S Austin St & Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Austin St
>
1133 S Austin St
>
1133 S Austin St & Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 5:00:22 AM
Creation date
5/6/2026 5:00:07 AM
Metadata
Fields
Template:
Plan
Permit Number
101121509
101121510
Full Address
1133 S Austin St
1133 S Austin St Unit# 2
Street Number
1133
Street Direction
S
Street Name
Austin
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)373 @ 10' 7 1/4"1406 (1.50")Passed (27%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)297 @ 10' 1/4"1631 Passed (18%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Moment (Ft-lbs)597 @ 7' 1 3/8"1478 Passed (40%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.063 @ 6' 7 1/16"0.428 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.100 @ 6' 7 1/8"0.571 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) <br />Member Length : 11' 1/2" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2018 <br />Design Methodology : ASD <br />Member Pitch : 2.83/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Overhang deflection criteria: LL (2L/240) and TL (2L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Beveled Plate - SPF 3.50"3.50"1.50"114 172 286 Blocking <br />2 - Hanger on 7 1/4" SPF beam 3.50"Hanger¹1.50"138 236 373 See note ¹ <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)10' 11" o/c <br />Bottom Edge (Lu)10' 11" o/c <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Roof Live <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)Comments <br />0 - Self Weight (PLF)0 to 10' 7 1/4"N/A 2.8 -- <br />1 - Tapered (PLF)0 to 2' 1 7/16"N/A 0.0 to 23.9 0.0 to 42.4 Generated from <br />Roof Geometry <br />2 - Tapered (PLF)2' 1 7/16" to 10' 7 1/4"N/A 0.0 to 44.9 0.0 to 84.9 Generated from <br />Roof Geometry <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. <br />MEMBER REPORT PASSED <br /> Roof, Hip Beam (HB-3) <br />1 piece(s) 2 x 8 DF No.2 <br />ForteWEB Software Operator Job Notes 3/6/2024 4:09:08 AM UTC <br />Hoang Pham <br />HD Engineering Construction Inc. <br />(714) 495-0056 <br />hdanpham@gmail.com <br />ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 <br />File Name: 1133 S Austin St. Unit 2 SA- Addition +Detached <br />ADUPage 7 / 15
The URL can be used to link to this page
Your browser does not support the video tag.