SCALE12NAILING SCHEDULE - <br />SCALE20STRUCTURAL NOTES - <br />DESIGN CRITERIA <br />1.THIS PROJECT HAS BEEN DESIGNED TO SUSTAIN, WITHIN THE LIMITATIONS SPECIFIED IN THE 2022 CALIFORNIA BUILDING CODE <br />(CBC). <br />GENERAL <br />1.DETAILS AND DIMENSIONS OF CONSTRUCTION SHALL BE VERIFIED AT THE SITE BY THE CONTRACTOR AND ANY DISCREPANCY <br />WITHIN THE PLANS, SECTIONS OR DETAILS SHALL BE PROMPTLY REPORTED TO THE STRUCTURAL ENGINEER OF RECORD. DO <br />NOT SCALE DRAWINGS. <br />2.PORTIONS OF THESE CONSTRUCTION DOCUMENTS ARE DIAGRAMMATIC ONLY. ITEMS INCLUDING, BUT NOT LIMITED TO, <br />LOCATIONS, SIZES, QUANTITIES, ACCESSORIES AND CONNECTIONS ARE INDICATED IN A REPRESENTATIONAL MANNER AND <br />MAY NOT BE COMPLETELY SHOWN. PROVIDE ALL WORK AND MATERIALS NECESSARY TO COMPLETE THE PROJECT AS <br />REPRESENTED IN THE CONSTRUCTION DOCUMENTS. <br />3.THESE DOCUMENTS ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN <br />AUTHORIZATION OF AXIOM STRUCTURAL DESIGN INC. <br />4.ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF LOCAL, COUNTY, STATE, OR FEDERAL AGENCIES HAVING <br />JURISDICTION. AXIOM STRUCTURAL DESIGN INC ASSUMES NO RESPONSIBILITY FOR SUPERVISION OF CONSTRUCTION OR <br />PROPER EXECUTION OF THE WORK SHOWN ON THESE DRAWINGS. SAFETY METHODS AND TECHNIQUES ARE THE SOLE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />5.ANY DEVIATIONS OR UNAUTHORIZED CHANGES TO THESE DRAWINGS ARE NOT THE RESPONSIBILITY OF AXIOM STRUCTURAL <br />DESIGN INC. DEVIATIONS FROM THE ORIGINAL DRAWINGS MUST BE APPROVED IN WRITING PRIOR TO CONSTRUCTION. IT IS <br />THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE STRUCTURAL ENGINEER OF THE PROGRESS OF THE PROJECT TO <br />FACILITATE SITE VISITS, TO ANSWER QUESTIONS AND VIEW THE PROGRESS OF THE WORK. <br />6.THE CONTRACTOR SHALL NOTIFY AXIOM STRUCTURAL DESIGN INC 48 HOURS PRIOR TO THE CLOSING OF ANY PHASE OF <br />CONSTRUCTION. <br />7.ALL STRUCTURAL MEMBERS SHOWN ON THE PLANS ARE DESIGNED AS IN THEIR FINAL LOCATION. AXIOM STRUCTURAL DESIGN <br />INC DOES NOT PERFORM CONSTRUCTION ENGINEERING OR ENGINEERING NECESSARY TO PLACE ANY STRUCTURAL MEMBERS <br />IN THEIR FINAL LOCATION. <br />8.FEATURES OF CONSTRUCTION INDICATED ARE TYPICAL. WHERE FEATURES ARE NOT FULLY OR SPECIFICALLY INDICATED BY THE <br />CONSTRUCTION DOCUMENTS, THEIR CONSTRUCTION SHALL BE AS INDICATED FOR IDENTICAL OR SIMILAR FEATURES <br />ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. IF ANY CONDITIONS REQUIRE CONSTRUCTION DIFFERENT THAN THAT <br />INDICATED ON THE CONSTRUCTION DOCUMENTS, NOTIFY THE STRUCTURAL ENGINEER OF RECORD. <br />9.STRUCTURAL ELEMENTS SHALL NOT BE REMOVED OR MODIFIED UNLESS INDICATED IN THE STRUCTURAL CONSTRUCTION <br />DOCUMENTS. IF STRUCTURAL ELEMENTS INTERFERE WITH THE WORK INDICATED IN ANY OTHER CONSTRUCTION DOCUMENTS, <br />NOTIFY THE STRUCTURAL ENGINEER OF RECORD. <br />10.THE CONSTRUCTION DOCUMENTS ARE NOT COMPLETE AND READY FOR CONSTRUCTION UNTIL THEY ARE APPROVED BY THE <br />ENFORCEMENT AGENCY AND SIGNED BY THE STRUCTURAL ENGINEER OF RECORD. <br />WOOD <br />1.LUMBER SHALL BE GRADED IN ACCORDANCE WITH CBC SECTION 2303.1, CLASSIFICATION, DEFINITION, METHODS OF GRADING <br />AND DEVELOPMENT OF DESIGN VALUES FOR ALL SPECIES OF LUMBER. SOLID SAWN LUMBER SHALL BE GRADE MARKED <br />DOUGLAS FIR (NINETEEN PERCENT, 19%, MOISTURE CONTENT, MAXIMUM, AT THE TIME OF INSTALLATION) AS FOLLOWS: <br />A)HORIZONTAL FRAMING MEMBERS (JOISTS, RAFTERS & BEAMS): D.F. NO. 2 <br />B)VERTICAL FRAMING MEMBERS (POSTS, 4X AND LARGER): D.F. NO. 2 <br />C)STUDS, 2x AND 3x: D.F. NO. 2 <br />2.PLYWOOD SHALL CONFORM TO THE CBC, CONSTRUCTION AND INDUSTRIAL PLYWOOD (5 PLY MINIMUM). PLYWOOD SHALL BE <br />MANUFACTURED USING EXTERIOR GLUE. PLYWOOD DIAPHRAGMS AND SHEAR WALLS SHALL BE CONSTRUCTED WITH <br />PLYWOOD SHEETS NOT LESS THAN 4 FEET BY 8 FEET, EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM <br />SHEET DIMENSION SHALL BE 24 INCHES UNLESS ALL EDGES OF THE UNDERSIZED SHEETS ARE SUPPORTED BY FRAMING <br />MEMBERS OR BLOCKING. FRAMING MEMBERS OR BLOCKING SHALL BE PROVIDED AT THE EDGES OF ALL SHEETS IN SHEAR <br />WALLS. DIAPHRAGM SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN FLUSH BUT SHALL <br />NOT FRACTURE THE SURFACE OF THE SHEATHING. <br />3.LUMBER SHALL NOT BE CUT OR NOTCHED UNLESS DETAILED ON THE STRUCTURAL DRAWINGS OR APPROVED IN WRITING, BY <br />THE STRUCTURAL ENGINEER OF RECORD. <br />4.ALL FOUNDATION PLATES OR SILLS AND SLEEPERS ON A CONCRETE SLAB, AND SILLS WHICH REST ON CONCRETE OR <br />MASONRY FOUNDATIONS, SHALL BE PRESSURE TREATED WOOD. <br />5.FOUNDATION PLATES OR SILLS SHALL BE BOLTED TO THE FOUNDATION OR FOUNDATION WALL WITH NOT LESS THAN 5 8 INCH <br />NOMINAL DIAMETER ANCHOR BOLTS EMBEDDED AT LEAST 7 INCHES INTO THE CONCRETE OR MASONRY AND SPACED NOT <br />MORE THAN 4 FEET APART. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIECE WITH ONE BOLT LOCATED WITHIN 9 <br />INCHES OF EACH END OF EACH PIECE. A PROPERLY SIZED NUT AND STEEL PLATE WASHER UNDER EACH NUT NOT LESS THAN <br />0.229"x3" SQUARE (SEE SIMPSON BPS PLATES) SHALL BE TIGHTENED ON EACH BOLT TO THE PLATE. THE HOLE IN THE PLATE <br />WASHER SHALL BE PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3 16" LARGER THAN THE BOLT DIAMETER <br />AND A SLOT LENGTH NOT TO EXCEED 13 4" PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND <br />NUT. THE PLATE SHALL EXTEND TO WITHIN 1 2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE WITH SHEATHING. PER SDPWS <br />SECTION 4.3.6.4.3. <br />6.ENDS OF WOOD GIRDERS ENTERING MASONRY OR CONCRETE WALLS SHALL BE PROVIDED WITH A 1 2 INCH AIR SPACE ON TOPS, <br />SIDES AND ENDS. <br />7.THE NUMBER AND SIZE OF NAILS CONNECTING WOOD MEMBERS SHALL NOT BE LESS THAN THAT SET FORTH IN THE CBC <br />8.ALL MACHINE BOLTS CONNECTING WOOD MEMBERS ON THE PLANS SHALL CONFORM TO ASTM A307, GRADE A. PLACE <br />MALLEABLE IRON OR STEEL PLATE WASHERS UNDER THE HEADS AND/OR NUTS OF ALL BOLTS WHEN BEARING DIRECTLY ON <br />WOOD. ALL BOLTS SHALL BE RETIGHTENED IMMEDIATELY PRIOR TO COVERING OR CLOSING IN. <br />9.PRE-MANUFACTURED WOOD CONNECTORS SHALL BE MANUFACTURED FROM THE SIMPSON STRONG-TIE COMPANY, INC. NO <br />SUBSTITUTIONS. ALL 4x4 AND LARGER POSTS SHALL HAVE SIMPSON CCQ OR ECCQ TYPE COLUMN CAPS UNLESS OTHERWISE <br />NOTED ON THE PLANS. <br />10.FASTENERS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT TREATED WOOD INCLUDING NUTS <br />AND WASHERS SHALL BE HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FOR <br />ADDITIONAL REQUIREMENTS SEE THE CBC. <br />POST INSTALLED ANCHORS NOTES: <br />1.THESE NOTES SHALL APPLY TO THE INSTALLATION, INSPECTION, AND TESTING OF ALL EXPANSION AND CHEMICAL ANCHORS. <br />2.INSTALL PER REQUIREMENTS OF THE ICC-ES EVALUATION REPORT FOR THE SPECIFIC ANCHOR OR AS REQUIRED BY THE <br />MANUFACTURER. ALL ANCHORS SHALL MEET THE MINIMUM EMBEDMENT, EDGE DISTANCE, SPACING, AND SLAB THICKNESS <br />CRITERIA ESTABLISHED BY THE RELEVANT ICC-ES EVALUATION REPORT. <br />3.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED <br />CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. WHEN INSTALLING <br />THEM INTO EXISTING PRE-STRESSED CONCRETE (PRE- OR POST-TENSIONED) LOCATE THE PRE-STRESSED TENDONS BY USING A <br />NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR <br />DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE <br />REINFORCEMENT AND THE DRILLED-IN ANCHOR AND/OR PIN. <br />4.POST INSTALLED ANCHORS INSTALL IN EXTERIOR & INTERIOR AREAS SUBJECT TO CORROSIVE AND WET CONDITIONS ARE TO <br />BE STAINLESS STEEL ANCHORS, UNO. <br />POST INSTALLED ANCHORS TESTING NOTES: <br />1.TEST LOADS AND FREQUENCY SHALL BE IN ACCORDANCE WITH THE CBC. <br />2.IF ANY ANCHOR(S) FAIL TESTING, ALL ANCHORS OF THE SAME TYPE SHALL BE TESTED, WHICH ARE INSTALLED BY THE SAME <br />TRADE, NOT PREVIOUSLY TESTED UNTIL TWENTY (20) CONSECUTIVE ANCHORS PASS, THEN RESUME THE INITIAL TEST <br />FREQUENCY. <br />3.WHEN POST INSTALLED ANCHORS ARE USED FOR; <br />A.SILL PLATE BOLTING APPLICATIONS, 10 PERCENT OF THE ANCHORS SHALL BE TESTED. <br />B.OTHER STRUCTURAL APPLICATIONS, ALL SUCH ANCHORS SHALL BE TESTED. <br />C.NONSTRUCTURAL APPLICATIONS SUCH AS EQUIPMENT ANCHORAGE, 50 PERCENT OR ALTERNATE BOLTS IN A GROUP, <br />INCLUDING AT LEAST ONE-HALF THE ANCHORS IN EACH GROUP, SHALL BE TESTED. <br />4.THE TESTING OF THE POST INSTALLED ANCHORS SHALL BE DONE IN THE PRESENCE OF THE SPECIAL INSPECTOR AND A REPORT <br />OF THE TEST RESULTS SHALL BE SUBMITTED TO THE ENFORCEMENT AGENCY. <br />EXCEPTIONS: <br />A.UNDERCUT ANCHORS THAT ALLOW VISUAL CONFIRMATION OF FULL SET SHALL NOT REQUIRE TESTING. <br />B.WHERE THE FACTORED DESIGN TENSION ON ANCHORS IS LESS THAN 100# AND THOSE ANCHORS ARE CLEARLY NOTED <br />ON THE APPROVED CONSTRUCTION DOCUMENTS, ONLY 10 PERCENT OF THOSE ANCHORS NEED BE TESTED. <br />C.WHERE ADHESIVE ANCHOR SYSTEMS ARE USED TO INSTALL REINFORCING DOWEL BARS IN HARDENED CONCRETE, ONLY <br />25% OF THE DOWELS SHALL BE TESTED IF ALL THE FOLLOWING CONDITIONS ARE MET: <br />a.THE DOWELS ARE USED EXCLUSIVELY TO TRANSMIT SHEAR FORCES ACROSS JOINTS BETWEEN EXISTING AND NEW <br />CONCRETE. <br />b.THE NUMBER OF DOWELS IN ANY ONE MEMBER EQUALS OR EXCEEDS TWELVE (12) <br />c.THE DOWELS ARE UNIFORMLY DISTRIBUTED ACROSS SEISMIC FORCE RESISTING MEMBERS (SUCH AS SHEAR WALLS, <br />COLLECTORS AND DIAPHRAGMS). <br />d.ANCHORS TO BE TESTED SHALL BE SELECTED AT RANDOM BY THE SPECIAL INSPECTOR / INSPECTOR OF RECORD <br />(IOR). <br />D.TESTING OF SHEAR DOWELS ACROSS COLD JOINTS IN SLABS ON GRADE, WHERE THE SLAB IS NOT PART OF THE LATERAL <br />FORCE-RESISTING SYSTEM SHALL NOT BE REQUIRED. <br />E.TESTING IS NOT REQUIRED OF POWER ACTUATED FASTENERS USED TO ATTACH TRACKS OF INTERIOR NON-SHEAR WALL <br />PARTITIONS FOR SHEAR ONLY, WHERE THERE ARE AT LEAST THREE (3) FASTENERS PER SEGMENT OF TRACK. <br />5.ACCEPTANCE CRITERIA FOR POST-INSTALLED ANCHORS SHALL BE BASED ON ICC-ESR OR MANUFACTURERS WRITTEN <br />INSTRUCTION, ACCEPTABLE TO THE ENFORCEMENT AGENCY. FIELD TEST SHALL SATISFY THE FOLLOWING MINIMUM <br />REQUIREMENTS. <br />A.HYDRAULIC RAM METHOD: ANCHORS TESTED WITH A HYDRAULIC JACK OR SPRING LOADED DEVICES SHALL MAINTAIN <br />THE TEST LOAD FOR A MINIMUM OF 15 SECONDS AND SHALL EXHIBIT NO DISCERNABLE MOVEMENT DURING THE <br />TENSION TEST, E.G., AS EVIDENCED BY LOOSENING OF THE WASHER UNDER THE NUT <br />FOR ADHESIVE ANCHORS, WHERE OTHER THAN BOND IS BEING TESTED, THE TESTING DEVICE SUPPORT SHALL NOT BE <br />LOCATED WITHIN 112 TIMES THE ANCHOR'S EMBEDMENT DEPTH TO AVOID RESTRICTING THE CONCRETE SHEAR CONE <br />TYPE FAILURE MECHANISM FROM OCCURRING. <br />B.TORQUE WRENCH METHOD: ANCHORS TESTED WITH A CALIBRATED TORQUE WRENCH MUST ATTAIN THE SPECIFIED <br />TORQUE WITHIN 1 2 TURN OF THE NUT. <br />EXCEPTIONS: <br />a.SLEEVE TYPE ANCHOR: ONE-QUARTER (1 4) TURN OF THE NUT FOR A 3 8"Ø ANCHOR ONLY. <br />b.SCREW TYPE ANCHOR: ONE-QUARTER (14) TURN OF THE SCREW AFTER INITIAL SEATING OF THE SCREW HEAD. <br />COLD-FORMED STEEL FRAMING <br />1.ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AISI. "SPECIFICATION FOR THE DESIGN OF <br />COLD-FORMED STEEL STRUCTURAL MEMBERS". <br />2.ALL STUDS SHALL BE FORMED FROM STEEL THAT CORRESPONDS TO THE MINIMUM REQUIREMENTS OF 2020 AISI STANDARDS. <br />3.ALL PRODUCTS SHALL BE MANUFACTURED BY CURRENT MEMBERS OF THE STEEL STUD MANUFACTURES ASSOCIATION (SSMA) <br />PER ICC LEGACY REPORT ESR-3064P EXCEPT SLOTTED TRACK SHALL BE MANUFACTURED BY "CALIFORNIA EXPANDED METAL <br />PRODUCTS COMPANY" PER ICC ESR-2012. <br />a.PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO, TRACKS CLIPS, WEB STIFFENERS, ANCHORS, FASTENING <br />DEVICES, RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND AS <br />RECOMMENDED BY THE MANUFACTURER FOR THE STEEL MEMBERS USED. <br />4.ALL STEEL MEMBERS AND COMPONENTS SHALL BE GALVANIZED. <br />5.ALL STEEL MEMBERS 18GA OR LIGHTER SHALL BE MANUFACTURED PER ASTM A653 S.S.,GRADE 33, AND 16GA OR HEAVIER PER <br />ASTM A653 S.S., GRADE 50, CLASS I. <br />6.THE MINIMUM UNCOATED STEEL THICKNESS AS DELIVERED TO THE JOBSITE SHALL BE: 20GA = 0.0329", 18GA = 0.0428", 16GA = <br />0.0538", 14GA = 0.0677", 12GA = 0.0966", AND 10GA 0.1180" <br />7.ALL STEEL MEMBERS SHALL HAVE THE MINIMUM EFFECTIVE STRUCTURAL SECTION PROPERTIES AS GIVEN IN SSMA. <br />8.ALL STUDS/JOISTS SHALL HAVE WEB PUNCH-OUTS AT 24" O.C. AT MID-DEPTH. PUNCH-OUTS SHALL NOT EXCEED HALF THE <br />MEMBER DEPTH (d/2) OR 21 2" IN WIDTH, WHICHEVER IS LESS, & 412" IN LENGTH. <br />9.NO STUD "PUNCH-OUTS" ARE ALLOWED WITHIN THE TOP OR BOTTOM 12" OF ANY STUDS. STUDS W/ "PUNCH-OUTS" WITHIN <br />THE TOP OR BOTTOM 12" ARE TO BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. <br />10.TRACK SHALL MATCH STUD/JOIST DEPTH & GAGE, AND FLANGE WIDTH SHALL BE 11 4", UON. ALL TRACKS TO BE UNPUNCHED <br />WITH SOLID WEBS. <br />11.FASTENING OF FRAMING COMPONENTS SHALL BE WITH SELF-DRILLING SELF-TAPPING SCREWS OR WELDING. WHERE DETAILS <br />CALL FOR SCREWS, THE MINIMUM SIZE SHALL BE AS FOLLOWS: #8 FOR 20GA MATERIAL, #10 FOR FOR 18 & 16GA MATERIAL, & #12 <br />FOR 14GA OR HEAVIER MATERIAL, UON. SCREW SIZE IS DETERMINED BY THE GA OF THE THICKEST PART BEING JOINED UON. <br />INSTALL SCREWS WITH THE HEAD IN CONTACT WITH THE THICKEST PART BEING JOINED UON. AS AN ALTERNATE, STEEL <br />MEMBERS 18GA OR HEAVIER MAY BE WELDED WITH A 12" LONG WELD (FILLET OR FLARE GROOVE) IN LIEU OF EACH SCREW, UON. <br />12.SCREW SPACING AND EDGE DISTANCE SHALL NOT BE LESS THAN 3 x D (D = NOMINAL SCREW DIAMETER). PENETRATION OF <br />SCREWS THROUGH JOINED MATERIALS SHOULD NOT BE LESS THAN 3 EXPOSED THREADS. ALL SCREW HEADS SHALL BE <br />LOW-PROFILE TYPE. <br />13.ALL SCREWS SHALL CONFORM WITH ASTM C1513 AND HAVE A CORROSION-RESISTANT COATING. <br />14.ALL WELDING SHALL CONFORM WITH AWS DI.3. ALL WELDING TO STRUCTURAL STEEL SHALL ALSO CONFORM WITH AWS DI.I. <br />THE ELECTRODES USED FOR WELDING SHALL HAVE A MINIMUM YIELD STRENGTH OF 60 KSI. ALL WELDS OF GALVANIZED STEEL <br />SHALL BE COATED WITH A ZINC-RICH PAINT. <br />15.FASTENING OF SHEATHING SHALL BE WITH SELF-DRILLING SELF-TAPPING SCREWS. #6 MIN FOR GYPSUM BOARD & #8 MIN FOR <br />STRUCTURAL PANELS. ALL SCREW HEADS SHALL BE FLAT-PROFILE TYPE. <br />EXISTING CONSTRUCTION NOTES: <br />1.CAREFULLY EXAMINE THE CONSTRUCTION DOCUMENTS AND NOTIFY THE STRUCTURAL ENGINEER OF RECORD OF ANY <br />CONFLICTS OR DISCREPANCIES WITHIN THE STRUCTURAL CONSTRUCTION DOCUMENTS AND BETWEEN ALL OTHER <br />CONSTRUCTION DOCUMENTS AND THE EXISTING CONSTRUCTION. <br />2.EXISTING CONSTRUCTION INDICATED IN THE CONSTRUCTION DOCUMENTS IS BASED UPON INFORMATION SHOWN ON <br />AVAILABLE EXISTING DRAWINGS AND/OR LIMITED VISUAL OBSERVATIONS. THE EXISTING CONSTRUCTION MAY VARY FROM <br />THAT INDICATED ON THE CONSTRUCTION DOCUMENTS. PROVIDE ALL WORK AND MATERIALS NECESSARY TO COMPLETE THE <br />PROJECT AS REPRESENTED IN THE CONSTRUCTION DOCUMENTS. <br />3.VERIFY ALL DIMENSIONS AND ELEVATIONS OF THE EXISTING CONSTRUCTION PRIOR TO STARTING CONSTRUCTION OR <br />FABRICATION. DO NOT SCALE EXISTING DRAWINGS. <br />4.EXISTING STRUCTURAL ELEMENTS SHALL NOT BE REMOVED OR MODIFIED UNLESS INDICATED IN THE STRUCTURAL <br />CONSTRUCTION DOCUMENTS. IF EXISTING STRUCTURAL ELEMENTS INTERFERE WITH THE WORK INDICATED IN ANY <br />CONSTRUCTION DOCUMENT, OR IF UNCERTAIN THAT AN ELEMENT IS STRUCTURAL, NOTIFY THE STRUCTURAL ENGINEER OF <br />RECORD. <br />5.PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF THE EXISTING STRUCTURE AND SITE DURING DEMOLITION AND <br />CONSTRUCTION. MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, PROVIDING ADEQUATE SHORING, BRACING, WEATHER <br />PROTECTION AND DUST PROTECTION. THE REMOVAL OR MODIFICATION OF EXISTING STRUCTURAL ELEMENTS SHALL BE <br />PERFORMED IN A MANNER TO PREVENT DAMAGE TO THOSE ELEMENTS TO REMAIN. SHOULD DAMAGE OCCUR TO ANY <br />EXISTING ELEMENTS, THEY SHALL BE RESTORED TO THEIR ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. <br />6.EXISTING FOUNDATIONS THAT MAY BE AFFECTED BY ANY EXCAVATIONS REQUIRED FOR THIS PROJECT SHALL BE <br />UNDERPINNED, SHORED OR SUPPORTED ADEQUATELY TO PREVENT SETTLEMENT AND LATERAL MOVEMENT. <br />7.IF EXISTING STRUCTURAL ELEMENTS NOT INDICATED FOR REPLACEMENT OR REPAIR ARE DISCOVERED TO BE DAMAGED OR <br />DIFFERENT THAN INDICATED ON THE CONSTRUCTION DOCUMENTS, NOTIFY THE STRUCTURAL ENGINEER OF RECORD. SUCH <br />DAMAGE OR DIFFERENCE SHALL INCLUDE, BUT NOT BE LIMITED TO, DRY-ROT, WATER DAMAGE, INSECT DAMAGE, POOR <br />WORKMANSHIP OR FIT-UP, BUCKLING, EXCESSIVE DEFLECTION, SAGGING, TWISTING, WARPING, AND DIFFERENT SIZE, <br />ORIENTATION, GRADE, QUALITY OR MATERIAL. <br />POWDER ACTUATED FASTENERS (LOW VELOCITY) <br />1.INSTALL PER REQUIREMENTS OF THE ICC-ES EVALUATION REPORT FOR THE SPECIFIC FASTENER OR AS REQUIRED BY THE <br />MANUFACTURER. ALL FASTENERS SHALL MEET THE MINIMUM EMBEDMENT, EDGE DISTANCE, SPACING, AND SLAB THICKNESS <br />CRITERIA ESTABLISHED BY THE RELEVANT ICC-ES EVALUATION REPORT. <br />A.HILTI X-U HILTI ICC-ES ESR-2269 <br />B.PDP SIMPSON STRONG TIE ICC-ES ESR-2138 <br />2.SHOT PINS TO CONCRETE SHALL BE 0.157"Ø WITH 11 4" EMBEDMENT MIN INTO CONCRETE, TYP UNO. <br />3.SHOT PINS TO STRUCTURAL STEEL SHALL BE 0.145"Ø W/ KNURLED SHANK DRIVEN INTO STEEL PER MANUFACTURER AND ICC-ES <br />REPORT, TYP UNO. <br />4.SHOT PINS MAY BE USED FOR SHEAR OR TENSION LOADS FOR ANCHORING ITEMS SUCH AS ACOUSTICAL CEILINGS, MECH. <br />DUCTS, CONDUITS, ETC., UNLESS SPECIFICALLY DETAILED OTHERWISE. SHOT PINS SHALL NOT BE USED FOR CEILING DIAGONAL <br />BRACING WIRES. ANY SHOT ANCHORS MUST HAVE AN ICC APPROVAL FOR THE TYPE OF CONCRETE USED ON THE JOB. <br />5.SHOT PINS SHALL NOT BE USED IN CONCRETE CURBS. <br />6.THE ALLOWABLE LOADS SHALL BE 80% OF ICC APPROVED VALUES. <br />7.TESTING: THE OPERATOR, TOOL, & FASTENER SHALL BE PRE-QUALIFIED BY THE PROJECT INSPECTOR. HE SHALL OBSERVE THE <br />TESTING OF THE FIRST 10 FASTENER INSTALLATIONS. A TEST "PULL-OUT" LOAD OF NOT LESS THAN TWICE THE DESIGN LOAD <br />SHALL BE APPLIED TO THE PIN IN SUCH A MANNER AS NOT TO RESIST THE SPALLING TENDENCY OF THE CONCRETE <br />SURROUNDING THE PIN. THEREAFTER, RANDOM TEST UNDER THE PROJECT INSPECTOR'S SUPERVISION SHALL BE MADE TO <br />APPROXIMATELY 1 IN 10 PINS. IF ANY PIN FAILS, TEST ALL PINS OF THE SAME CATEGORY NOT PREVIOUSLY TESTED UNTIL 20 <br />CONSECUTIVE PASS, THEN RESUME THE INITIAL TESTING FREQUENCY. <br />SEISMIC DESIGN CRITERIA <br />SITE CLASS OCCUPANCY <br />CATEGORY <br />RISK <br />CATEGORY <br />SEISMIC <br />DESIGN <br />CATEGORY <br />IMPORTANCE <br />FACTOR, IE <br />SS S1 SMS SDS <br />D - DEFAULT II II D 1.0 1.293 0.461 1.551 1.034 <br />WIND DESIGN CRITERIA <br />EXPOSURE <br />BASIC <br />WIND <br />SPEED <br />VELOCITY <br />PRESSURE <br />EXPOSURE <br />COEFFICIENT, <br />Kz & Kh <br />TOPOGRAPHIC <br />FACTOR, KZT <br />DIRECTIONALITY <br />FACTOR, Kd <br />GROUND <br />ELEVATION <br />FACTOR, Ke <br />VELOCITY <br />PRESSURE, qh <br />C 95 MPH 0.90 1.0 0.85 1.0 17.4 psf <br />WEDGE ANCHORS IN CONCRETE 1,2 <br />NOMINAL SIZE / DIAMETER (inch)1/4 3/8 1/2 5/8 3/4 1 <br />DRILL BIT DIAMETER (inch)1 4 3 8 1 2 5 8 3 4 1 <br />MIN HOLE DEPTH 3 (inch) <br />HILTI KWIK BOLT TZ2 +1 4 +1 4 +1 4 3.1 +12 +1 4 +3 8 <br />SIMPSON STRONG-BOLT 2 +18 +1 8 +1 4 +1 4 +1 4 +1 4 <br />INSTALLATION TORQUE 4 (ft-lb) <br />HILTI <br />KWIK BOLT TZ2 <br />CARBON STEEL 4 30 50 40 110 185 <br />STAINLESS STEEL 6 30 40 60 125 185 <br />SIMPSON STRONG-BOLT <br />2 <br />CARBON STEEL 4 30 60 90 150 230 <br />STAINLESS STEEL 4 30 65 80 150 N/A <br />FOOTNOTES: <br />1.ANCHOR TYPE, SIZE, NOMINAL EMBEDMENT AND MATERIAL (CARBON VS STAINLESS) SHALL BE AS SPECIFIED IN THESE DRAWINGS. <br />NO SUBSTITUTION SHALL BE ALLOWED WITHOUT WRITTEN CONSENT FROM THE S.E.O.R. <br />1.1.HILTI ANCHORS SHALL BE INSTALLED PER THE REQUIREMENTS OF ICC-ES REPORT ESR-4266 <br />1.2.SIMPSON ANCHORS SHALL BE INSTALLED PER THE REQUIREMENTS OF ICC-ES REPORT ESR-3037 <br />2.CONCRETE STRENGTH (f'c) SHALL BE 3,000 psi MIN <br />3.MINIMUM HOLE DEPTH SHALL BE MEASURED FROM THE BOTTOM OF THE SPECIFIED NOMINAL ANCHOR DEPTH <br />3.1.SHALL BE +12 FOR ANCHORS WITH 33 4" NOMINAL EMBEDMENT <br />4.INSTALLATION TORQUE SHALL SERVE AS THE TORQUE TEST VALUE <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-8 <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-7 <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-6 <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-5 SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-1 <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-2 <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-3 <br />SCALENOT USED <br />NOT <br /> <br />U <br />S <br />E <br />D <br />-4 <br />FASTENING SCHEDULE 1 <br />DESCRIPTION OF BUILDING ELEMENT NUMBER AND TYPE SPACING AND LOCATION <br />ROOF <br />BLOCKING BETWEEN CEILING JOISTS, <br />RAFTERS OR TRUSSES <br />TO TOP PLATE OR OTHER FRAMING BELOW <br />(3) 8d; OR <br />(3) 10d BOX; OR <br />(3) 8d x 3" <br />BOTH ENDS, TOENAIL <br />BLOCKING BETWEEN RAFTERS OR TRUSSES <br />NOT AT THE WALL TOP PLATE, <br />TO RAFTER OR TRUSS <br />(2) 8d; OR <br />(2) 8d x 3"BOTH ENDS, TOENAIL <br />(2) 16d; OR <br />(3) 8d x 3"END NAIL <br />FLAT BLOCKING <br />TO TRUSS AND WEB FILLER <br />16d @ 6" O.C.; OR <br />8d x 3" @ 6" O.C.FACE NAIL <br />CEILING JOIST <br />TO TOP PLATE <br />(3) 8d; OR <br />(3) 10d BOX: OR <br />(3) 8d x 3" <br />EACH JOIST, TOENAIL <br />CEILING JOIST <br />NOT ATTACHED TO PARALLEL RAFTER, <br />LAPS OR PARTITIONS (NO THRUST) <br />(3) 16d; OR <br />(4) 10d BOX; OR <br />(4) 8d x 3" <br />FACE NAIL <br />CEILING JOIST <br />ATTACHED TO PARALLEL RAFTER (HEEL JOINT) <br />VARIES BY APPLICATION <br />SEE CBC 2019 TABLE 2308.7.3.1 FACE NAIL <br />COLLAR TIE <br />TO RAFTER <br />(3) 10d; OR <br />(4) 10d BOX: OR <br />(4) 8d x 3" <br />FACE NAIL <br />RAFTER OR ROOF TRUSS <br />TO TOP PLATE <br />(3) 10d; OR <br />(3) 16d BOX; OR <br />(4) 10d BOX; OR <br />(4) 8d x 3" <br />TOENAIL <br />RAFTER <br />TO RIDGE VALLEY OR HIP RAFTERS; <br />OR ROOF RAFTER TO 2-INCH RIDGE BEAM <br />(2) 16d; OR <br />(3) 10d BOX; OR <br />(3) 8d x 3" <br />END NAIL <br />(3) 10d; OR <br />(4) 16d BOX; OR <br />(4) 10d BOX; OR <br />(4) 8d x 3" <br />TOENAIL <br />WALL <br />STUD TO STUD <br />AT DOUBLE STUDS <br />(NOT IN STRUCTURALLY SHEATHED WALLS) <br />16d; OR <br />10d BOX; OR <br />8d x 3" <br />FACE NAIL <br />(2) ROWS @ 32" O.C., <br />STAGGERED <br />(NET SPACING = 16" O.C.) <br />STUD TO STUD <br />AT DOUBLE STUDS <br />IN STRUCTURALLY SHEATHED WALLS <br />16d <br />FACE NAIL <br />(2) ROWS @ 16" O.C., <br />STAGGERED <br />(NET SPACING = 8" O.C.) <br />STUD TO STUD <br />AT INTERSECTING WALL CORNERS <br />(NOT IN STRUCTURALLY SHEATHED WALLS) <br />16d; OR <br />16d BOX; OR <br />8d x 3" <br />FACE TO EDGE NAIL <br />16d @ 16" O.C.; OR <br />ELSE @ 12" O.C. <br />STUD TO STUD <br />AT INTERSECTING WALL CORNERS <br />IN STRUCTURALLY SHEATHED WALLS <br />16d FACE TO EDGE NAIL <br />8" O.C. <br />BUILT-UP HEADER (2x TO 2x MEMBERS)16d; OR <br />16d BOX <br />FACE NAIL TO EDGE NAIL <br />16d @ 16" O.C.; OR <br />ELSE @ 12" O.C. <br />CONTINUOUS HEADER TO STUD (4) 8d; OR <br />(4) 10d BOX TOENAIL <br />TOP PLATE TO TOP PLATE 16d <br />FACE NAIL <br />(2) ROWS @ 32" O.C., <br />STAGGERED <br />(NET SPACING = 16" O.C.) <br />TOP PLATE TO TOP PLATE <br />LAPS AT CORNERS AND INTERSECTIONS <br />(2) 16d; OR <br />(3) 10d BOX; OR <br />(3) 8d x 3" <br />FACE NAIL <br />BOTTOM PLATE TO JOIST, <br />RIM JOIST, BAND JOIST OR BLOCKING <br />(NOT IN STRUCTURALLY SHEATHED WALLS) <br />16d; OR <br />16d BOX; OR <br />8d x 3" <br />FACE NAIL <br />16d @ 16" O.C.; OR <br />ELSE @ 12" O.C. <br />BOTTOM PLATE TO JOIST, <br />RIM JOIST, BAND JOIST OR BLOCKING <br />IN STRUCTURALLY SHEATHED WALLS <br />(2) 16d; OR <br />(3) 16d BOX; OR <br />(4) 8d x 3" <br />FACE NAIL <br />16" O.C. <br />STUD TO TOP OR BOTTOM PLATE <br />(4) 8d; OR <br />(4) 10d BOX; OR <br />(4) 8d x 3" <br />TOE NAIL <br />(2) 16d; OR <br />(3) 10d BOX; OR <br />(3) 8d x 3" <br />END NAIL <br />(2x TOP OR BOTTOM PLATE) <br />FLOOR <br />JOIST TO SILL, TOP PLATE, OR GIRDER <br />(3) 8d; OR <br />(3) 10d BOX; OR <br />(3) 8d x 3" <br />TOE NAIL <br />RIM JOIST, BAND JOIST, OR BLOCKING <br />TO TOP PLATE, SILL OR OTHER FRAMING <br />BELOW <br />8d; OR <br />10d BOX; OR <br />8d x 3" <br />TOENAIL <br />6" O.C. <br />BUILT-UP GIRDERS AND BEAMS, <br />2x LUMBER LAYERS <br />20d; OR <br />10d BOX; OR <br />8d x 3" <br />FACE NAIL <br />TOP AND BOT, STAGGERED <br />ON OPPOSITE SIDES <br />20d @ 32" O.C.; OR <br />ELSE @ 24" O.C. <br />AND: <br />(2) 20d; OR <br />(3) 10d BOX; OR <br />(3) 8d x 3" <br />FACE NAIL <br />ENDS AND AT EACH SPLICE <br />LEDGER STRIP <br />SUPPORTING JOISTS OR RAFTERS <br />(3) 16d; OR <br />(4) 10d BOX; OR <br />(4) 8d x 3" <br />FACE NAIL <br />EACH JOIST OR RAFTER <br />JOIST TO BAND JOIST OR RIM JOIST <br />(3) 16d; OR <br />(4) 10d BOX; OR <br />(4) 8d x 3" <br />END NAIL <br />BRIDGING OR BLOCKING <br />TO JOIST, RAFTER OR TRUSS <br />(2) 8d; OR <br />(2) 10d BOX; OR <br />(2) 8d x 3" <br />TOENAIL <br />BOTH ENDS <br />FOOTNOTES: <br />1.NAILS SHALL BE COMMON WIRE NAILS, U.N.O. <br />2.WHEN A SPECIFIC NUMBER OF FASTENERS IS SPECIFIED THEY SHALL BE INSTALLED EQUALLY SPACED ACROSS <br />THE MEMBER(S) <br />3.WHERE OTHER PLANS OR DETAILS ON THESE DRAWINGS SPECIFY DIFFERENT FASTENERS (SIZE, TYPE, <br />QUANTITY, SPACING, ETC) THAN WHAT IS LISTED ABOVE FOR THE SAME APPLICATION THEY SHALL TAKE <br />PRECEDENCE OVER THIS TABLE <br />4.FOR ADDITIONAL APPLICATIONS (INCLUDING STRUCTURAL PANELS, SHEATHING, PLANKS, ETC) NOT LISTED <br />ABOVE, REFER TO THE CBC <br />LICENSED A RCHITECT <br />STATEOF CALIFORNIA <br />No. C 31423 <br />DR. BY: <br />S 6026 <br />PROF <br />ENGINEERREGISTERED <br />ESSIONAL <br />UCRTS <br />TURAL <br />EOF <br />STAT I NIA <br />CALFOR <br />WORERHSEAL <br />IM <br />HC M <br />NA <br />A X I O M <br />S T R U C T U R A L <br />D E S I G N , I N C <br />1 6 7 S T H O R S T R E E T <br />T U R L O C K , C A 9 5 3 8 0 <br />w w w .a x i o m s d .c o m <br />(2 0 9 ) 4 8 4 -8 6 4 0 <br />(2 0 9 ) 4 9 5 -1 3 5 5 <br />(2 0 9 ) 4 0 2 -4 9 4 0 <br />M I C H A E L : <br />K E V I N : <br />N U N O : <br />25079 <br />B LKJIHGFEDC <br />10 <br />8 <br />© ASPEN STREET 2026 <br />12 <br />0 <br />7 <br /> <br />E <br /> <br />F <br />R <br />U <br />I <br />T <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />IN <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />A <br />N <br />D <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />S <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br />S <br /> <br />C <br /> <br />& <br /> <br />D <br />PH <br />O <br />E <br />N <br />I <br />X <br /> <br />H <br />O <br />U <br />S <br />E <br />OR <br />A <br />N <br />G <br />E <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br />N <br />KEY PLAN <br />AGENCY APPROVALS <br />AGENCY NO. <br />DRAWING TITLE <br />SHEET NO. <br />ONIS <br />S <br />U <br />E <br />D <br />FO <br />R CITY RESUBMITTAL 01 <br />2/6/2026 <br />NM <br />215021.51JOB: <br />AS SHOWNSCALE: <br />6 <br />4 <br />2 <br />TH <br />I <br />S <br /> <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br /> <br />I <br />S <br /> <br />M <br />E <br />A <br />N <br />T <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />P <br />R <br />I <br />N <br />T <br />E <br />D <br /> <br />3 <br />0 <br />" <br />X <br />4 <br />2 <br />" <br />. <br /> <br /> <br />A <br />T <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />S <br />I <br />Z <br />E <br />, <br /> <br />D <br />I <br />S <br />R <br />E <br />G <br />A <br />R <br />D <br /> <br />R <br />E <br />F <br />E <br />R <br />E <br />N <br />C <br />E <br />S <br /> <br />T <br />O <br /> <br />S <br />C <br />A <br />L <br />E <br />. <br />PLOTSTAMP <br />S0.1 <br />STRUCTURAL NOTES