Laserfiche WebLink
1. DOUBLE DOOR W/ CARD READER <br />(7) PAIR BUTT HINGES <br />(1) PAIR ELECTRIC HINGE <br />(2) ELECTRIC LEVER LOCKSET <br />(1) CARD READER <br />(2) CLOSERS <br />(1) ASTRAGAL <br />(1) COORDINATOR <br />(2) AUTOMATIC DOORBOTTOM <br />1. ALL DOORS TO COMPLY WITH ADA ACCESS REQUIREMENTS, UON. REFER TO DETAILS ON <br />THIS SHEET. <br />2. WOOD DOORS SHALL BE WDMA PREMIUM GRADE. ALL DOORS SHALL BE 5-PLY <br />CONSTRUCTION AS MANUFACTURED BY ALGOMA HARDWOODS, EGGERS INDUSTRIES, OR <br />MARSHFIELD DOOR. 7-PLY DOORS ARE NOT ACCEPTABLE. ANY SUBSTITUTIONS TO THE <br />THREE LISTED MANUFACTURES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT <br />PRIOR TO BID. <br />3. ALL STAIN GRADE DOORS SHALL BE FACTORY FINISHED WITH MFR’S STANDARD UV CURED <br />FINISH. SEE DOOR FINISH TYPES FOR ADDITIONAL INFORMATION. <br />4. HINGES SHALL BE BY HAGER, MCKINNEY, OR STANLEY. ALL OPENINGS WITH CLOSERS AND <br />ALL RATED OPENINGS SHALL HAVE BALL BEARING HINGES. DOORS GREATER THEN 36” IN <br />WIDTH SHALL HAVE HEAVYWEIGHT HINGES. ONE HINGE SHALL BE PROVIDED FOR EACH 30” <br />OF DOOR HEIGHT. <br />5. LOCKS SHALL MATCH BUILDING STANDARD, WHERE APPLICABLE. VERIFY LOCKING <br />HARDWARE OF ALL EXISTING DOORS TO MATCH WHERE APPLICABLE. <br />6. CLOSERS SHALL BE BY LCN. ALL CORRIDOR DOORS SHALL HAVE 4010/4110 MODEL <br />CLOSERS WITH INDICATED FINISH. INTERIOR DOORS SHALL HAVE 1461 MODEL CLOSERS <br />WITH INDICATED FINISH. CONCEALED CLOSERS TO BE 3130 SERIES, WHERE OCCUR. <br />7. FLUSH BOLTS AND COORDINATORS SHALL BE BY IVES OR DOOR CONTROLS <br />INTERNATIONAL. <br />8. FLAT GOODS SHALL BE BY IVES, HAGER, OR ROCKWOOD. <br />9. SMOKE GASKET, THRESHOLDS, ASTRAGALS, DOOR BOTTOMS, ETC. SHALL BE BY PEMKO <br />OR NATIONAL GUARD PRODUCTS <br />10. PROVIDE FLOOR STOP AT ALL LOCATIONS WHERE DOOR WILL STRIKE PARTITION. PROVIDE <br />RISERS AND DOOR MATES AS NECESSARY. <br />11. RIGHT HAND LEAF OF PAIR DOORS TO BE ACTIVE, UON. <br />12. MOUNT CLOSER ON PULL SIDE OF DOOR, UON. <br />13. FIELD MEASURE FLOOR TO CEILING DOORS FOR PROPER FIT. <br />14. CONNECT ELECTROMAGNETIC HOLDERS TO BUILDING LIFE SAFETY SYSTEM. <br />15. PROTECT PREFINISHED SURFACES AND REPAIR ANY DAMAGE. <br />16. SUBMIT DOOR AND HARDWARE SCHEDULE WITH PROPOSED ITEMS TO ARCHITECT FOR <br />REVIEW BEFORE ORDERING ITEMS. <br />17. ALL HDWR TO HAVE FINISH: 626 SATIN CHROME, UON. VERIFY IN FIELD TO MATCH EXISTING. <br />18. PROVIDE APPROPRIATE SMOKE SEALS AND ‘S’ LABEL ASSEMBLIES AT ALL RATED DOORS. <br />19. COORDINATE WITH SECURITY VENDOR ON ALL DOORS REQUIRING CARD READERS OR <br />OTHER EXITING / SECURITY DEVICES. <br />20. ALL RATED DOORS WITH GLASS TO HAVE CLEAR ‘FIRELITE’ GLASS WITH RATING TO MATCH <br />DOOR. <br />21. LEVER TYPE TO BE: SCHLAGE, SPARTA, UON. VERIFY IN FIELD TO MATCH EXISTING. <br />22. ANY FIRE DOORS THAT ARE TO BE DEMOLISHED AND REPLACED TO REMAIN UNTIL (N) <br />DOORS ARE READY FOR INSTALLATION. <br />23. KEYING BY LANDLORD, UON. <br />24. PAINT EXISTING PAINT GRADE DOORS AND FRAMES TO MATCH ADJACENT PARTITION, UON. <br />25. PROVIDE A 10" SMOOTH SURFACE ON THE BOTTOM OF ALL ACCESSABLE DOORS, PER CBC <br />11B-404.2.10 <br />26. EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE <br />IDENTIFIED BY A MANUFACTURER'S DESIGNATION SPECIFYING WHO APPLIED THE <br />DESIGNATION, THE MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING STANDARD. <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE <br />PURPOSED OF SAFETY GLAZING IN: (CBC 2406) <br />A. FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED <br />EDGE OF THE GLAZING IS WITHIN 24 INCHES ARC OF EITHER VERTICAL EDGE OF THE <br />DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE <br />GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING SURFACE. <br />B. SWINGING DOORS <br />C. IF APPLICABLE, GUARDS AND RAILINGS REGARDLESS OF AREA OR HEIGHT ABOVE A <br />WALKING SURFACE. INCLUDE COMPLETE INSTALLATION AND ANCHORAGE DETAILS <br />FROM THE MANUFACTURER OR STRUCTURAL ENGINEER. (CBC 2407) <br />D. DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, <br />BATHTUBS, AND SHOWERS. <br />E. THE NOMINAL THICKNESS OF THE GLASS SHALL BE 1/4" INCHES. <br />27. CONTRACTOR TO VERIFY EXISTING LOCK CYLINDERS THROUGHOUT PROJECT TO <br />ACCOMMODATE NEW TENANT KEYING SYSTEM. TO BE REPLACED AS REQUIRED. <br />28. CONTRACTOR TO VERIFY EXISTING EXTERIOR DOOR EGRESS HARDWARE IS FUNCTIONAL. <br />TO BE REPLACED AS REQUIRED. <br />LE <br />V <br />E <br />L <br /> <br />A <br />R <br />E <br />A <br />MA <br />X <br /> <br />S <br />l <br />o <br />p <br />e <br /> <br />1 <br />: <br />4 <br />8 <br />4'-0" <br />3' <br />- <br />8 <br />" <br />PU <br />S <br />H <br /> <br />S <br />I <br />D <br />E <br />DOOR CLEARANCES <br />5' <br />- <br />0 <br />" <br />PU <br />L <br />L <br /> <br />SI <br />D <br />E <br />4' <br />- <br />0 <br />" <br />* REQD FIRE DOORS, MAX EFFORT = 15 LBS <br />* 1/2 " MAX. THRESHOLD. 1/4" = 1/2" MAX SLOPE = <br />* 10" KICK PLATE OR SMOOTH FULL WIDTH <br />DOOR <br />SECTION @ DOOR / THRESHOLD <br />THRESHOLD <br />SEC. 11B-404.2.5 CBC <br />2'-0" MIN. CLR. @ EXTERIOR <br />1'-6" MIN. CLR. @ INTERIOR <br />LC <br />MIN. <br />32" <br />CLR. <br />* MAX EFFORT FOR INTERIOR DOORS = 5 LBS <br />* MAX EFFORT FOR EXTERIOR DOOR = 5 LBS <br />* OPERABLE WITHOUT GRASPING <br />HARDWARE <br />PUSH SIDE <br />SEC. 11B-404.2.9 CBC <br />SEC. 11B-404.2.10 CBC <br />1 <br />2 <br />12" <br />PROVIDE THIS ADDITIONAL SPACE <br />WHEN BOTH A LATCH AND CLOSER <br />ARE PRESENT. <br />34 <br />" <br /> <br />- <br /> <br />4 <br />0 <br />" <br />HA <br />R <br />D <br />W <br />A <br />R <br />E <br /> <br />HE <br />I <br />G <br />H <br />T <br />* 4" FOR SOLID GLASS DOORS 30 BEVEL ALL <br />SURFACES. <br />AUTOMATIC DOORS:WHEN AN AUTOMATIC DOOR OPERATOR IS UTILIZED TO OPERATE A PAIR <br />OF DOORS, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED <br />OPENING WIDTH OF 32” WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS <br />CLOSED POSITION. <br />FLOOR LEVEL AT DOORS:REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A FLOOR <br />OF LANDING ON EACH SIDE OF A DOOR. <br />THRESHOLDS:THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2” LOWER THAN THE <br />THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4” AND 1/2” SHALL BE BEVELED <br />WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL TO 2 UNITS HORIZONTAL. CHANGE IN <br />LEVEL GREATER THAN 1/2” SHALL BE ACCOMPLISHED BY MEANS OF A RAMP. <br />MANEUVERING CLEARANCES AT DOORS:MIN MANEUVERING CLEARANCES AT DOORS SHALL <br />BE AS SHOWN IN FIGURE 11B-404.2.4.1 AND 11B-404.2.4.1 (2016 CBC). THE FLOOR OR GROUND <br />AREA WITHIN THE REQUIRED CLEARANCES SHALL BE LEVEL AND CLEAR. <br />THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST <br />60” AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48” AS MEASURED AT <br />RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. <br />THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL <br />EXTEND 24” PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18” PAST THE <br />STRIKE EDGE FOR INTERIOR DOORS. <br />THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING <br />OTHER THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A MINIMUM OF 48” OF CLEAR <br />SPACE FROM ANY DOOR OPENING INTO SUCH VESTIBULE WHEN THE DOOR IS POSITIONED AT <br />AND ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. DOORS IN A SERIES SHALL SWING <br />EITHER IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS. <br />CLOSER-EFFORT TO OPERATE DOORS:MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT <br />EXCEED 5 LBS. FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING <br />APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR <br />FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE <br />UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE <br />MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE <br />BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS. <br />DOOR CLOSER:IF THE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER <br />SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL <br />TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3” FROM THE LATCH, MEASURED TO THE <br />LANDING EDGE OF THE DOOR. THE MINIMUM ALLOWABLE DISTANCE FROM THE FINISHED <br />FLOOR TO THE BOTTOM OF THE DOOR CLOSER WILL BE 78 INCHES. THE DOOR WILL TAKE AT <br />LEAST 5 SECONDS TO MOVE FROM A POINT 90 DEGREES OPEN POSITION TO THE 12 DEGREE <br />POSITION <br />DOOR HARDWARE: HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED <br />BETWEEN 34” AND 44” ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND- <br />ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE <br />EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER <br />HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP <br />THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS <br />DIRECTION. <br />RECESSED DOORS: WHERE THE PLANE OF THE DOORWAY IS OFFSET 8” OR MORE FROM ANY <br />OBSTRUCTION WITHIN 18” MEASURED LATERALLY ON THE LATCH SIDE, THE DOOR SHALL BE <br />PROVIDED WITH MANEUVERING CLEARANCE FOR FRONT APPROACH. <br />SMOOTH SURFACE:THE BOTTOM 10” OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL <br />HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A <br />WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE <br />NARROW FRAME DOORS ARE USED, A 10” HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE <br />PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR <br />FOOTREST WITHOUT CREATING A TRAP OR A HAZARDOUS CONDITION. <br />EXIT DOORS:ALL EXIT DOORS TO SWING IN THE DIRECTION OF TRAVEL AND BE OPERABLE <br />WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. <br />1 <br />SEE SCHED <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SIM <br />SIM <br />3 <br />A6.00 - MC <br />2 <br />A6.00 - MC <br />SCHEDULED DOOR <br />SCHEDULED FRAME, VERIFY THROAT <br />WIDTH WITH SCHEDULED WALL <br />SCHEDULED PARTITION <br />SCHEDULED PARTITION <br />SCHEDULED FINISH <br />FLOOR <br />SCHEDULED <br />DOOR <br />SCHEDULED FRAME <br />6" C-H STUD, 600CH-34 <br />5/8" TYPE "X" GYPSUM BOARD <br />CONTINUOUS FIRE RETARDING <br />SEALANT, BOTH SIDES <br />SLAB /STRUCTURE <br />SCHEDULED CEILING, WHERE OCCURS <br />ACOUSTICAL SEALANT, WHERE SCHEDULED <br />TOP TRACK, S.S.D <br />FULL WIDTH UNFACED SOUND ATTENUATION <br />BLANKET FULL HEIGHT OF PARTITION <br />BOTTOM TRACK, S.S.D. <br />1" TYPE "X" GYPSUM BOARD <br />SLAB/STRUCTURE <br />UL# U415 <br />*REFER TO UL#U415 <br />PERFORMANCE SPECIFICATION <br />SH <br />A <br />F <br />T <br /> <br />S <br />I <br />D <br />E <br />PLYWOOD SHEATHING, WHERE OCCURS, <br />S.S.D. <br />N <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND <br />UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED <br />WITHOUT WRITTEN CONSENT OF ARCHITECT. COPYRIGHTED. <br />PROJECT NO. CHECKED BY <br />SHEET NO. <br />SCALE @ ARCH E1 <br />SHEET NAME <br />CLIENT NAME <br />ARCHITECT'S STAMP <br />PROJECT TEAM <br />KEY PLAN <br />4/ <br />1 <br />5 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />2 <br />: <br />3 <br />1 <br />: <br />1 <br />4 <br /> <br />P <br />M <br />Au <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />C <br />o <br />l <br />l <br />e <br />c <br />t <br />o <br />r <br />s <br /> <br />- <br /> <br />S <br />N <br />A <br /> <br />4 <br />. <br />0 <br />/ <br />s <br />n <br />a <br />1 <br />6 <br />1 <br />0 <br />p <br />h <br />4 <br />_ <br />R <br />V <br />T <br />26 <br />. <br />r <br />v <br />t <br />As indicated23008.00 <br />A6.00 -MC <br />sna1610ph4 -PHASE 4 <br />1610 E ST ANDREW PL, SUITE 240 <br />SANTA ANA, CA 92705 <br />DOOR SCHEDULE & <br />SPECIFICATIONS <br />COLLECTORS <br />- <br />DOOR NOTES ACCESSIBILITY REQUIREMENTS <br />DOOR FINISH TYPES <br />CL: CLEAR VENEER <br />PT: PAINTED PT-X, SEE FINISH SCHEDULE <br />GL: CLEAR TEMPERED GLASS <br />FM: FILM PATTERN (SEE ELEVATIONS) <br />ST: STAINED TO MATCH ARCHITECT'S SAMPLE <br />ME: MATCH EXISTING <br />RE: REFINISHED <br />DOOR CONSTRUCTION TYPES <br />WD: SOLID CORE, WOOD VENEER <br />WD/GL: SOLID CORE, WOOD VENEER W/ TEMPERED GLASS LITE <br />PG: SOLID CORE, PAINT GRADE <br />PG/GL: SOLID CORE, PAINT GRADE W/ TEMPERED GLASS LITE <br />GL: TEMPERED GLAZING <br />HM: HOLLOW METAL <br />MTL/GL: METAL W/ TEMPERED GLASS LITE <br />ME: MATCH EXISTING <br />FRAME FINISH TYPES <br />CL: CLEAR ANODIZED FACTORY FINISH <br />BK: BLACK ANODIZED FACTORY FINISH <br />PT: PAINTED - FACTORY FINISH TO MATCH ARCH SAMPLE PT-X <br />ST: STAINED TO MATCH ARCHITECT'S SAMPLE <br />ME: MATCH EXISTING <br />FRAME CONSTRUCTION TYPES <br />AL: ALUMINUM <br />HM: HOLLOW METAL, FULLY WELDED <br />WD: WOOD <br />ME: MATCH EXISTING <br />DOOR SCHEDULE <br />DOOR HARDWARE SCHEDULE <br />DOOR SCHEDULE NOTES: <br />• (E) DOORS TO REMAIN IN CURRENT LOCATION AND RECEIVE NEW HARDWARE OR SECURITY UPGRADES PER SCHEDULE. <br />• ALL OTHER SCHEDULED DOORS, FRAMES AND HARDWARE TO BE NEW. <br />• SEE SECURITY DRAWINGS FOR ADDITIONAL INFORMATION. <br />DOOR ELEVATION LEGEND <br />ISSUE RECORD <br />∆ DATE REASON FOR ISSUE BY <br />2026-0130 ISSUE FOR PERMIT <br />B 2026-0317 REVISION 1 <br />C 2026-0415 REVISION 2 <br />DO <br />O <br />R <br /> <br />N <br />U <br />M <br />EL <br />E <br />V <br />. <br /> <br />T <br />Y <br />P <br />E <br />HD <br />W <br />R <br /> <br />G <br />R <br />O <br />U <br />P <br />ROOM DOOR FRAME <br />FI <br />R <br />E <br /> <br />R <br />A <br />T <br />I <br />N <br />G <br />PA <br />N <br />I <br />C <br /> <br />H <br />D <br />W <br />R <br />CTRL'D <br />ACCESS S.R.D. COMMENTSNAME <br />SIZE <br />CONST. <br />TYPE <br />FINISH <br />TYPE <br />CONST. <br />TYPE <br />FINISH <br />TYPEWIDTH HEIGHT THICK <br />EL01 1 1 VESTIBULE 8' - 0" 7' - 10 1/2" 1 1/2" HM PT HM PT 45 MIN - CR <br />EL02 1 1 8' - 0" 7' - 10 1/2" 1 1/2" HM PT HM PT 45 MIN - CR <br />3" = 1'-0"2DR - HM - JAMB <br />3" = 1'-0"3DR - HM - HEAD / SILL <br />DOOR DETAILS PARTITION DETAIL <br />3" = 1'-0"1C-H STUD SHAFT WALL, 1-HR <br />W30A <br />UL #U415 PERFORMANCE SPECIFICATION <br />STEEL STUDS — "C-H" SHAPED STUDS, MIN 2-1/2 IN. DEEP, FABRICATED FROM MIN 25 MSG GALV <br />STEEL. CUT TO LENGTHS 3/8 TO 1/2 IN. LESS THAN FLOOR-TO-CEILING HEIGHT AND SPACED 16 OC. <br />GYPSUM BOARD — GYPSUM LINER PANELS, NOM 1 IN. THICK, 600 MM (FOR METRIC SPACING) WIDE. <br />PANELS CUT 1 IN. LESS IN LENGTH THAN FLOOR TO CEILING HEIGHT. VERTICAL EDGES INSERTED IN <br />“T” SHAPED SECTION OF C-T STUDS, "H" PORTION OF "C-H" STUDS, THE HOLDING TABS OF THE “I” <br />SHAPED STUD, OR THE GAP BETWEEN THE TWO 3/4 IN. LEGS OF THE “E” STUDS. FREE EDGE OF END <br />PANELS ATTACHED TO LONG LEG OF VERTICAL "J" RUNNERS WITH 1-5/8 IN. LONG TYPE S STEEL <br />SCREWS SPACED NOT GREATER THAN 12 IN. OC. WHEN WALL HEIGHT EXCEEDS LINER PANEL <br />LENGTH, LINER PANEL MAY BE BUTTED TO EXTEND TO THE FULL HEIGHT OF THE WALL. HORIZONTAL <br />JOINTS NEED NOT BE BACKED BY STEEL FRAMING. IN SYSTEM I, BUTT JOINTS IN LINER PANELS ARE <br />STAGGERED MIN 36 IN. BUTT JOINTS BACKED WITH 6 IN. BY 22 IN. STRIPS OF 3/4 IN. THICK GYPSUM <br />WALLBOARD (ITEM 4). WALLBOARD STRIPS CENTERED OVER BUTT JOINTS AND SECURED TO LINER <br />PANELS WITH SIX 1-1/2 IN. LONG TYPE G STEEL SCREWS, THREE SCREWS ALONG THE 22 IN. <br />DIMENSION AT THE TOP AND BOTTOM OF THE STRIPS. FOR ALL SYSTEMS, WHEN J-SHAPED RUNNERS <br />(ITEM 1) ARE SUPPLIED WITH SECUREMENT TABS, FREE EDGE OF END PANELS MAY BE SECURED BY <br />BENDING THE SECUREMENT TABS, MAX. 12 IN. OC, TO A 90 DEGREE ANGLE TO SECURELY FRICTION- <br />FIT PANELS IN J-SHAPED RUNNERS. <br />GYPSUM BOARD — SYSTEM A — 1 HR GYPSUM PANELS, WITH BEVELED, SQUARE OR TAPERED <br />EDGES, NOM 5/8 IN. THICK, 48 IN. OR 1200 MM WIDE, APPLIED VERTICALLY OR HORIZONTALLY, <br />ATTACHED TO STUDS WITH 1 IN. LONG TYPE S STEEL SCREWS SPACED 12 IN. WHEN INSTALLED <br />VERTICALLY OR 8 IN. OC WHEN INSTALLED HORIZONTALLY. HORIZONTAL JOINTS NEED NOT BE <br />BACKED BY STEEL FRAMING. <br />JOINT TAPE AND COMPOUND — SYSTEMS A, B, C, E, F, G, H, I <br />JOINTS ON OUTER LAYERS OF GYPSUM BOARDS (ITEM 4 AND 4A) COVERED WITH PAPER TAPE AND <br />JOINT COMPOUND. PAPER TAPE AND JOINT COMPOUND MAY BE OMITTED WHEN GYPSUM BOARDS <br />ARE SUPPLIED WITH SQUARE EDGES. EXPOSED SCREW HEADS COVERED WITH JOINT COMPOUND. <br />C