ELECTRICAL LEGEND <br />J <br />GFCI <br />ALL 15A AND 20A- RECEPTACLES SHALL BE LISTED AS <br />TAMPER-RESISTANCE. (210.52 CEC) <br />FIXED APPLIANCES SUCH AS FOOD WASTE GRINDERS, DISHWASHERS, <br />WASHING MACHINES, DRYERS, LAUNDRY TRAY LOCATIONS, BUILT-IN <br />REFRIGERATORS OR FREEZERS, FURNACES, AC UNITS, BUILT-IN <br />HEATERS OR ANY OTHER FIXED APPLIANCE WITH A MOTOR OF ¼ H.P. <br />OR LARGER SHALL BE ON A SEPARATE 20 AMP BRANCH CIRCUIT <br />COMPLYING WITH CEC SECTION 422.10. <br />A WORK LIGHT, SWITCH, AND RECEPTACLE OUTLETS COMPLYING WITH <br />CEC SECTION 210.70(3) IS REQUIRED FOR ATTICS, UNDER FLOOR <br />SPACES, UTILITY ROOMS, AND BASEMENTS WHERE THESE SPACES ARE <br />USED FOR STORAGE OR CONTAIN EQUIPMENT REQUIRING SERVICING. <br />THE LIGHTING OUTLET SHALL BE PROVIDED AT OR NEAR THE <br />EQUIPMENT REQUIRING SERVICING. <br />ALL BRANCH CIRCUITS SUPPLYING 120V 15-AMPERE AND 20-AMPERE <br />OUTLETS IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION <br />ROOMS, CLOSETS, HALLWAYS AND SIMILAR ROOMS OR AREAS <br />SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT <br />INTERRUPTER (AFCI). (210.12(A) CEC) <br />ALL WALL SPACES, 2 FEET OR MORE IN WIDTH, SHALL HAVE <br />RECEPTACLES INSTALLED SUCH THAT NO POINT MEASURED <br />HORIZONTALLY ALONG THE FLOOR LINE IS MORE THAN 6 FEET <br />FROM A RECEPTACLE (12 FEET MAXIMUM SPACING). (210.52 (A) (1) <br />& (2) CEC) <br />REF.WH <br />W/D <br />(N) BEDROOM <br />(N) LIVING/KITCHEN(N) BATHROOM <br />client approval <br />principal in charge <br />issues / revisions <br />drawing title <br />scale <br />Sheet No.: <br />E-2 <br />project number <br />date <br />As indicated <br />060825 <br />GARCIA RESIDENCE <br />ADU CONVERSION <br />T 714.305.8928 <br />MARIA GARCIA <br />2058 S OAK ST. <br />SANTA ANA, CA. 92707 <br />Project Address <br />2058 S OAK ST. <br />SANTA ANA, CA. 92707 <br />The ideas and designs represented herein and this drawing, all <br />prepared by BKW STUDIO, are for the use solely with respect to <br />this project and BKW STUDIO shall retain all common law, <br />statutory and other reserved rights including copyright and they <br />shall not be used by others for any other purpose without written <br />permission of BKW STUDIO. <br />Copyright @ 2025 <br />13733 FRANCISCO DR <br />LA MIRADA, CA. 90638 <br />626.272.8479 <br />binhkwong@yahoo.com <br />BKW STUDIO <br />09-10-2025 <br />POWER PLAN <br />POWER PLAN <br />(N) ELECTRICAL <br />PANEL "P" <br />(E) ELECTRICAL <br />PANEL "M" <br />P-39-41 <br />1"C.O.-3#8+1#10GND <br />30A/240V/1PH <br />GFCI/WP <br />4 <br />P-20 <br />1"C.O.-3#8+1#10GND <br />30A/240V/1PHP-40-42 <br />2 <br />AFCI <br />2 <br />GFCI/WP <br />4 AFCI4AFCI <br />2 <br />AFCI <br />(TYP.) <br />P-2-4P-10 <br />GFCI <br />6 GFCI <br />5 <br />AFCI <br />(TYP.) <br />P-5-7 <br />5 <br />AFCI <br />7 <br />AFCI <br />7AFCI <br />GFCI <br />5 <br />GFCI 9 GFCI 11 <br />P-9-11 <br />GFCI <br />9 <br />P-16 <br />GFCI