Laserfiche WebLink
<br />TEP is a family of companies licensed to provide different services in different jurisdictions. Depending on the jurisdiction , professional engineering and land <br />surveying services are provided by TEP OpCo LLC, a Delaware limited liability company, TEP Engineering, PLLC, a North Carolina professional limited liability <br />company, or M&H Engineering, PLLC, a New York professional limited liability company. General contractor services are provide d by TEPDB OpCo LLC, a <br />Delaware limited liability company. We acquire the requisite licenses in each state. Additional information can be obtained from the company. <br />November 8, 2025 <br /> <br />Jon Maxwell 326 Tryon Road • Raleigh • NC 27603 <br />M Squared Wireless (919) 661-6351 •StructuresRAL@tepgroup.net <br />1387 Calle Avanzado <br />San Clemente, CA 92673 <br />(949) 391-6824 <br /> <br />Subject: Appurtenance Mount Analysis <br /> <br />Carrier Designation: AT&T Mobility Reconfiguration <br /> Site Number: CLL01580 <br /> Site Name: Fairview Business Park <br /> FA Location Code: 12844670 <br /> IWM Job Number: WSLOS0068803 <br /> <br />Engineering Firm Designation: TEP Project Number: 353924.1184084 <br /> <br />Site Data: 2500-2520 S. Fairview Street <br />Santa Ana, Orange County, CA 92704 <br /> Latitude 33° 42' 48.41'', Longitude -117° 54' 35.49'' <br /> 60.0± Foot - Monoeucalyptus Tower <br /> 55.0 Foot Mount Height - T-Arm <br />Dear Jon Maxwell, <br /> <br />TEP is pleased to submit this “Appurtenance Mount Analysis” to determine the structural integrity of the <br />antenna mount on the above-mentioned tower. <br /> <br />The purpose of the analysis is to determine acceptability of the mount's stress level. Based on our analysis we <br />have determined the stress level for the mount structure, under the following load case, to be: <br /> <br /> LC1: Existing + Proposed + Reserved Loading Sufficient Capacity* <br /> Note: See Table 2 for the existing, proposed, and reserved loading <br /> *Sufficient upon completion of the changes listed in the “Recommendations” section of this report <br /> <br /> <br /> <br /> <br />The analysis has been performed in accordance with the ANSI/TIA-222-H Structural Standard for Antenna <br />Supporting Structures, Antennas, and Small Wind Turbine Support Structures, the 2022 California Building Code, <br />and the AT&T Mount Technical Guidance – Revision 25. <br /> <br />All equipment proposed in this report shall be installed in accordance with the appurtenances listed in Table 2 for <br />the determined available structural capacity to be effective. <br /> <br />We at TEP appreciate the opportunity of providing our continuing professional services to you and M Squared <br />Wireless. If you have any questions or need further assistance on this or any other projects, please give us a call. <br /> <br />Respectfully submitted by: <br /> <br /> <br /> <br />Adam M. Amortnont, P.E., S.E. <br />Mount Capacity <br />36.8% <br />2500 & 2520 3/4 S Fairview St.,