Laserfiche WebLink
SHEET <br />NO.DESCRIPTION <br />G-2 GROUNDING DETAILS <br />SHEET <br />NO.DESCRIPTION <br />T-1 TITLE SHEET <br />GN-1 GENERAL NOTES <br />A-1.1 SITE PLAN <br />A-1.2 ENLARGED SITE PLAN <br />A-2 EQUIPMENT LAYOUTS <br />A-3.1 EXISTING ANTENNA PLAN <br />A-3.2 NEW ANTENNA PLANS <br />A-4 ELEVATIONS <br />A-5 ELEVATIONS <br />D-1 DETAILS <br />G-1 GROUNDING PLAN <br />APPROVED APPROVED <br />AS NOTED <br />REVISE & <br />RESUBMIT <br />OWNER REPRESENTATIVE DATE <br />SITE ACQUISITION DATE <br />CONSTRUCTION MANAGER DATE <br />ZONING DATE <br />RF ENGINEER DATE <br />APPROVAL BLOCK <br />TITLE SHEET <br />mobility corp. <br />mobility corp. <br />SHEET TITLE <br />SHEET NUMBER <br />DRAWN BY: <br />CHECKED BY:JM <br />SD <br />1452 EDINGER AVE. <br />TUSTIN, CA 92780 <br />PROJECT NO: <br />AT&T SITE NO:CLL01580 <br />12844670 <br />90% CD'S FOR REVIEW <br />EXPIRATION DATE: 06/30/2027 <br />DATE SIGNED: 04/21/2026 <br />APPLICANT: <br />CLL01580 <br />FAIRVIEW BUSINESS PARK <br />2500 & 2500 3/4 S FAIIRVIEW ST. <br />SANTA ANA, CA 92704 <br />SD04/09/2025A <br />ENGINEER: <br />T-1 <br />PLANS PREPARED BY: <br />95% CD'S FOR REVIEW DS11/04/2025B <br />100% CD'S FOR SUBMITTAL DS12/02/20250 <br />100% CD'S REV - CODE DS04/21/20261 <br />SI <br />CALL CALIFORNIA ONE CALL <br />(800) 422-4133 <br />CALL 3 WORKING DAYS <br />BEFORE YOU DIG! <br />SITE INFORMATION <br />SITE ADDRESS:2500 & 2500 3/4 S FAIIRVIEW ST. <br />SANTA ANA, CA 92704 <br />LATITUDE (NAD 83):33.7134472 <br />33° 42' 48.40992" N <br />LONGITUDE (NAD 83):-117.9098583 <br />117° 54' 35.48988" W <br />GROUND ELEVATION:±43' AMSL <br />JURISDICTION:CITY OF SANTA ANA <br />PROPERTY OWNER:DONALD P. JOHNSON <br />160 EMERALD BAY <br />LAGUNA BEACH, CA 92780 <br />TOWER OWNER:AT&T TOWERS <br />PARCEL/MAP NUMBER:414-101-05 <br />STRUCTURE TYPE:MONOEUCALYPTUS <br />STRUCTURE HEIGHT:60'-0" A.G.L. <br />ZONING CLASSIFICATION:C4 - COMMERCIAL <br />OCCUPANCY:U <br />CONSTRUCTION TYPE:V-B <br />POWER SUPPLIER:SCE <br />PROJECT TEAM <br />VICINITY MAP <br />DIRECTIONS <br />CODE COMPLIANCE <br />ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING <br />CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT <br />CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. <br />·2025 CALIFORNIA BUILDING CODE (CBC) <br />·2025 CALIFORNIA TITLE 24, PART 10 <br />·2025 CALIFORNIA FIRE CODE (CFC) <br />·2025 CALIFORNIA ENERGY CODE <br />·2025 CALIFORNIA ELECTRICAL CODE <br />·2025 CALIFORNIA MECHANICAL CODE (CMC) <br />·ANSI EIA/TIA-222-I <br />·CITY/COUNTY ORDINANCES <br />DIRECTIONS FROM AT&T OFFICE (1452 EDINGER AVE., TUSTIN, CA 92780): <br />1.HEAD SOUTHEAST ON INDUSTRIAL DR. <br />2.TURN RIGHT ONTO RED HILL AVE. <br />3.TURN RIGHT ONTO WARNER AVE. <br />4.CONTINUE ON E WARNER AVE. <br />5.TURN LEFT ONTO S FAIRVIEW ST. <br />6.TURN RIGHT. <br />7.DESTINATION WILL BE ON THE RIGHT. <br />DRAWING INDEX <br />SCOPE OF WORK <br />NE <br />N <br />E <br />SESW <br />W <br />NW <br />S <br />DRAWING SCALE <br />THESE DRAWINGS ARE SCALED TO FULL SIZE AT 22"x34" AND HALF SIZE AT 11"x17". CONTRACTOR <br />SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONFITIONS ON THE JOB SITE AND SHALL <br />IMMEDIATELY NOTIFY THE DESIGNER / ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE <br />PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. <br />CONTRACTOR SHALL USE BEST MANAGEMENT PRACTICE TO PREVENT STORM WATER POLLUTION <br />DURING CONSTRUCTION. <br />THIS PROJECT CONSISTS OF THE MODIFICATIONS OF AN EXISTING AT&T MOBILITY UNMANNED <br />TELECOMMUNICATIONS FACILITY. THE SCOPE WILL CONSIST OF THE FOLLOWING: <br />ANTENNA AREA: <br />·RELOCATE (3) AIR6449 B77D (BOTTOM) <br />·INSTALL (3) AIR6419 B77G (TOP) WITH (3) NEW 2 7/8" OD MAST PIPES <br />·REMOVE ALL MDT BRACKETS <br />·ROTATE COLLAR - SET ARMS TO 100, 220, 340 TO ELIMINATE SKEW <br />·RELOCATE ALL ANTENNAS TO ACHIEVE PROPOSED EDGE TO EDGE SEPARATIONS <br />EQUIPMENT AREA: <br />·REUSE (1) EXISTING NETSURE 512 OUTDOOR PDU <br />·INSTALL (1) NETSURE 512 OD RETROFIT KIT W/-58V <br />·INSTALL (5) C48/58-2000 P3 CONVERTERS <br />·INSTALL (2) R48-2000 E3 RECTIFIERS <br />·INSTALL (3) 50A DC BREAKERS <br />EXISTING ANTENNAS:12 EXISTING RRUS:15 <br />REMOVED ANTENNAS:0 REMOVED RRUS:0 <br />PROPOSED ANTENNAS:3 PROPOSED RRUS:0 <br />TOTAL ANTENNAS:15 TOTAL RRUS:15 <br />CLL01580 - FAIRVIEW BUSINESS PARK <br />FA NUMBER: <br />IWM ID: <br />IWM SITE ID: <br />USID: <br />PACE NUMBER: <br />12844670 <br />WSLOS0068803 <br />SICA009891 <br />195375 <br />MRLOS115828 <br />2500 & 2500 3/4 S FAIIRVIEW ST., SANTA ANA, CA 92704 <br />APPLICANT:AT&T MOBILITY <br />1452 EDINGER AVE. <br />TUSTIN, CA 92780 <br />A/E:M SQUARED WIRELESS <br />1387 CALLE AVANZADO <br />SAN CLEMENTE, CA 92673 <br />CONTACT: JON MAXWELL <br />PHONE: (949) 391-6824 <br />PROJECT MANAGEMENT FIRM:ERICSSON <br />KARIANNE KERR <br />PHONE: (360) 513-1204 <br />EMAIL: karianne.kerr@ericsson.com <br />RF ENGINEER:AT&T MOBILITY <br />CONTACT: ATHAR ALI <br />PHONE: (469) 534-2496 <br />EMAIL: aa250e@att.com <br />SITE ACQ MANAGER:M SQUARED WIRELESS <br />FELICIA PHILLIPS <br />PHONE: (714) 791-6643 <br />EMAIL: felicia@msquaredwireless.com <br />NOTE: <br />NO NEW AC POWER WORK PROPOSED UNDER THIS PROJECT.