THESE PLANS ARE THE PROPERTY OF IDS GROUP INC., AND ARE NOT TO BE USED
<br />FOR ANY OTHER THAN THE LOCATION SHOWN HEREON.
<br />1. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR
<br />CONSENT OF THE ARCHITECT OR ENGINEER WHOSE SIGNATURE APPEARS
<br />HEREON.
<br />2. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE
<br />OF CONCRETE MASONRY UNITS, CENTERLINE OF COLUMNS AND BEAMS, OR FACE
<br />OF STUDS, UNLESS OTHERWISE NOTED. FINISH FLOOR ELEVATIONS ARE TO TOP
<br />OF CONCRETE SLAB OR TOP OF INTERIOR PAVING UNLESS OTHERWISE NOTED.
<br />3. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL.
<br />REQUEST FOR SUBSTITUTIONS SHALL BE IN ACCORDANCE WITH SECTION 01 25 00
<br />OF SPECIFICATIONS.
<br />A. THESE DRAWINGS DO NOT CONTAIN THE NECESSARY COMPONENTS FOR
<br />CONSTRUCTION SAFETY.
<br />B. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE STATE
<br />CONSTRUCTION SAFETY ORDERS ENFORCED BY THE STATE DIVISION OF
<br />INDUSTRIAL SAFETY.
<br />1. CONTRACTOR FOR THE PROJECT SHALL BE RESPONSIBLE FOR OBTAINING ALL
<br />REQUIRED BUILDING PERMITS PRIOR TO COMMENCING WORK.
<br />2. THE CONTRACTOR SHALL ENSURE THAT ALL WORK IS DONE IN A PROFESSIONAL
<br />WORK-MAN-LIKE MANNER BY SKILLED MECHANICS AND SHALL REPLACE ANY
<br />NEW AND/OR EXISTING MATERIALS OR ITEMS INDICATED TO REMAIN DAMAGED
<br />BY ANY CAUSE DURING CONSTRUCTION.
<br />3. THE CONTRACTOR AND/OR SUBCONTRACTOR SHALL, PRIOR TO THE
<br />SUBMISSION OF HIS BID OR PERFORMANCE OF WORK, NOTIFY THE OWNER OF
<br />ANY WORK CALLED OUT ON THE DRAWINGS OR IN THE SPECIFICATIONS IN HIS
<br />TRADE THAT CANNOT BE FULLY GUARANTEED OR WARRANTED FROM
<br />DEFECTIVE WORKMANSHIP OR MATERIAL DEFECTS.
<br />4. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF DETAILS ARE CONSIDERED
<br />UNSOUND, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE
<br />PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO
<br />OBJECTIONS TO THE DETAIL. DETAILS ARE INTENDED TO SHOW END RESULT OF
<br />DESIGN, MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS
<br />AND CURRENT TRADE PRACTICE AND SHALL BE INCLUDED AS PART OF THIS
<br />PROJECT.
<br />5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINISHES AT POINT OF
<br />CONNECTIONS FOR ALL WORK (ARCHITECTURAL, STRUCTURAL, MECHANICAL
<br />AND ELECTRICAL) FINISHES WILL MATCH THOSE SPECIFIED OR EXISTING IN LINE,
<br />TEXTURE AND FINISH. SPOT PAINTING IS NOT ACCEPTABLE. NEW FINISHES
<br />SHALL BE FROM CORNER TO CORNER, FLOOR TO CEILING, ETC.
<br />6. UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE NEW AND OF GOOD
<br />QUALITY. WHERE EXISTING MATERIALS ARE INDICATED TO BE SALVAGED,
<br />CONTRACTOR SHALL INVENTORY, CLEAN,BOX PROTECT, AND STORE ITEMS FOR
<br />REUSE ON THE PROJECT. ITEMS NOT REUSED SHALL BE RETURNED TO OWNER.
<br />7. COORDINATION: THE GENERAL AND EACH SUB CONTRACTOR SHALL BE
<br />RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER SUB
<br />CONTRACTORS TO ASSURE COMPLIANCE WITH DRAWINGS AND
<br />SPECIFICATIONS, AND THE ACCURATE LOCATION OF ARCHITECTURAL,
<br />STRUCTURAL, MECHANICAL AND ELECTRICAL BUILDING ELEMENTS. THEIR
<br />REQUIRED OPENINGS CLEARANCES SUPPORT SYSTEMS ARE ALL
<br />INTERCONNECTED AND COORDINATED.
<br />8. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL
<br />TRADES AND FOR BEING AWARE OF ALL CONDITIONS THAT AFFECT THEIR WORK.
<br />NOTIFY OWNER, IN WRITING, WITHIN 3 WORKING DAYS OF AWARD OF CONTRACT,
<br />OF THE PROPOSED DELIVERY SCHEDULE, OF ANY EQUIPMENT, FINISHES OR
<br />MATERIAL, FOR WHICH THAT SCHEDULE WILL PREVENT THE INSTALLATION FROM
<br />BEING COMPLETED AT THE TIME OF THE SCHEDULED PROJECT COMPLETION.
<br />9. COORDINATION OF WORK:
<br />10. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF
<br />EXISTING SITE PRIOR TO BIDDING AND START OF CONSTRUCTION. THE
<br />CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS WHICH
<br />PREVENT THE PROPER EXECUTION OF ITS WORK. THE DRAWINGS SHALL NOT
<br />BE SCALED.
<br />11. CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA
<br />BUILDING CODE, ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES,
<br />ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS GOVERNING
<br />THE WORK. IN CASE OF CONFLICTING INFORMATION, THE MORE STRINGENT
<br />REQUIREMENT SHALL GOVERN.
<br />12. GENERAL CONTRACTOR TO ARRANGE INSPECTIONS AT APPROPRIATE
<br />INTERVALS. CONTRACTOR TO INCLUDE CONSTRUCTION MANAGER BY NOTIFYING
<br />AT LEAST 36 HOURS AHEAD OF THE CITY INSPECTION TIME.
<br />13. ALL CONTRACTOR'S WORK SHALL BE OF THE QUALITY TO PASS INSPECTIONS BY
<br />LOCAL AND STATE AUTHORITIES, LENDING INSTITUTIONS, THE ARCHITECT AND
<br />ENGINEERS, INSPECTOR OF RECORD, AND OWNER. ANY ONE OR ALL OF THE
<br />ABOVE MENTIONED INSPECTORS MAY INSPECT TRADE(S) AT ANY TIME, AND ANY
<br />CORRECTIONS NEEDED TO MEET THE REQUIRED QUALITY OF CONSTRUCTION
<br />SHALL BE DONE IMMEDIATELY AFTER NOTIFYING THE ARCHITECT AND THE
<br />OWNER FOR APPROVAL.
<br />14. THE CONTRACTOR/SUB-CONTRACTORS SHALL INSPECT THE SITE PRIOR TO
<br />START OF CONSTRUCTION AND NOTIFY OWNER AND THE ARCHITECT OF ANY
<br />EXISTING CONDITIONS THAT MAY AFFECT THE WORK INCLUDING ELEMENTS
<br />THAT MAY BE SUBJECT TO DAMAGE DURING DEMOLITION AND RENOVATION. THE
<br />CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS, PRIOR TO START OF
<br />CONSTRUCTION AND NOTIFY OWNER AND ARCHITECT OF ANY DISCREPANCIES
<br />BETWEEN THE EXISTING DIMENSIONS AND THE DRAWING DIMENSIONS THAT MAY
<br />AFFECT THE WORK. THE CONTRACTOR SHALL OBTAIN DIRECTION FROM OWNER
<br />ON RESOLUTION OF THE DISCREPANCIES BETWEEN THE EXISTING CONDITIONS
<br />AND DIMENSIONS AND DRAWINGS PRIOR TO STARTING ANY WORK THAT MAY BE
<br />AFFECTED BY SUCH DISCREPANCIES.
<br />15. CLEANUP: TYPICALLY EACH SUBCONTRACTOR IS HELD RESPONSIBLE FOR
<br />CLEANUP OF THE WORK OF HIS TRADE BY THE GENERAL CONTRACTOR.
<br />HOWEVER, THE GENERAL CONTRACTOR SHALL BE HELD SOLELY RESPONSIBLE
<br />FOR CONTINUOUS CLEANUP AS THE JOB PROGRESSES, AND FINAL CLEANUP
<br />UPON SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL BE RESPONSIBLE
<br />FOR CLEANING UP AND REMOVING FROM THE JOB SITE ALL TRASH AND DEBRIS,
<br />IMMEDIATELY UPON COMPLETION OF HIS DAILY WORK. CONTINUOUS CLEANUP
<br />SHALL KEEP THE JOB FREE AT ALL TIMES FROM UNREASONABLE BUILDUP OF
<br />DEBRIS, WRAPPERS, CONTAINERS, WASTE MATERIALS, ETC., WHICH MAY CAUSE
<br />ACCIDENTS, UNDUE HARDSHIP ON THE TRADESMAN, AND WORK PROGRESS.
<br />FINAL CLEANUP INCLUDES CLEANING OF ALL SURFACES TO A "LIKE NEW"
<br />CONDITION AND PREPARING THE BUILDING FOR ITS INTENDED USE.
<br />16. THE CONTRACTOR SHALL AT ALL TIMES MAINTAIN THE SITE AND ADJACENT
<br />AREAS IN A CLEAN, NEAT, AND ORDERLY MANNER. THE CONTRACTOR SHALL BE
<br />RESPONSIBLE ONLY FOR DEBRIS THAT IS A RESULT OF THE WORK, INCLUDING
<br />ANY THAT MAY RESULT FROM THE WORKERS. THE CONTRACTOR SHALL BE
<br />RESPONSIBLE FOR PROVIDING HIS OWN REFUSE CONTAINERS AND SHALL AT NO
<br />TIME USE THE BUILDING REFUSE CONTAINERS.
<br />17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF
<br />THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED.
<br />18. CONTRACTOR SHALL PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING
<br />OF NOT LESS THAN 2-A OR 2-10BC WITHIN 75 FEET OF TRAVEL DISTANCE TO ALL
<br />PORTIONS OF THE BUILD OUT AREA DURING CONSTRUCTION.
<br />19. OBTAIN ALL CAL / OSHA CONSTRUCTION ACTIVITY PERMITS, PRIOR TO OBTAINING
<br />THE BUILDING PERMIT, AS REQUIRED BY AND IN ACCORDANCE WITH CCR TITLE 8,
<br />SECTION 341.
<br />20. DEMARCATE AND NOTIFY THE REGIONAL NOTIFICATION CENTER (DIG ALERT, 811)
<br />AT LEAST TWO WORKING DAYS PRIOR TO ANY EXCAVATIONS.
<br />21. HOLD ON-SITE MANDATORY CONSTRUCTION AND SAFETY MEETINGS WEEKLY.
<br />1. THE SCOPE OF THIS PROJECT IS AS GENERALLY DEPICTED IN THESE
<br />INSTRUMENTS OF SERVICE AS PART OF THE CONTRACT DOCUMENTS. WORK
<br />INCLUDING: POINTS OF CONNECTION, NOT SPECIFICALLY DEPICTED, THAT
<br />NEED TO BE MADE ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
<br />ALL WORK PERFORMED EVEN IN REMOTE AREAS OF THE BUILDING OR SITE,
<br />PERTAINING TO THIS PROJECT SHALL COMPLY WITH THE INTENT OF
<br />CONTRACT DOCUMENTS.
<br />2. THESE CONTRACT DOCUMENTS COVER THE FURNISHING AND INSTALLATION
<br />OF MATERIALS AND WORK AS CALLED FOR ON THE DRAWINGS OR IN THE
<br />SPECIFICATIONS (OR IN BOTH) WHICH ARE BOUND SEPARATELY AND ARE A
<br />PART OF THE CONTRACT. IT SHALL BE THE RESPONSIBILITY OF EACH
<br />CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE
<br />FINALIZING THEIR BID AND BEFORE THE INSTALLATION OF THEIR WORK. ANY
<br />DISCREPANCY BETWEEN THE ARCHITECTURAL AND THE CONSULTING
<br />ENGINEER(S) DRAWINGS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION
<br />BY WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN
<br />CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY
<br />THE CONTRACTOR AT HIS OWN EXPENSE AND AT NO EXPENSE TO THE
<br />OWNER OR ARCHITECT.
<br />3. GENERAL REQUIREMENTS, DESCRIBING THE PROJECT'S ADMINISTRATIVE
<br />REQUIREMENTS AND THE PHYSICAL ASPECTS OF CONSTRUCTION, ARE
<br />PROVIDED WITHIN EACH PROFESSIONAL DISCIPLINE'S PROJECT
<br />SPECIFICATION AND GENERAL NOTATION. GENERAL REQUIREMENTS ARE NOT
<br />LIMITED TO THE INSTRUMENT OF SERVICES AND MAY EXTEND TO THE
<br />CONTRACT DOCUMENTS AND OWNER REQUIREMENTS.
<br />4. THE PROJECT SPECIFICATIONS CONSISTING OF THE WRITTEN REQUIREMENTS
<br />FOR MATERIAL, EQUIPMENT, SYSTEMS, STANDARDS AND WORKMANSHIP FOR
<br />THE WORK, AND PERFORMANCE OF RELATED SERVICES ARE CONTAINED
<br />WITHIN EACH OF THE ARCHITECT AND THE ARCHITECT'S INSTRUMENT OF
<br />SERVICES. REFER TO GENERAL NOTES FOR ADDITIONAL PROJECT
<br />STANDARDS INFORMATION. DOCUMENTS INDICATED AS 'REFERENCE
<br />DOCUMENT' ARE NOT CONSIDERED INSTRUMENTS OF SERVICES AND ARE
<br />BEING ISSUED TO PROVIDE ASSISTANCE DURING THE REGULATORY AGENCY
<br />CONTRACT DOCUMENT REVIEW.
<br />5. OVERALL AND BUILDING SCOPE DIAGRAMS PROVIDE GUIDLINE TO IDENTIFY
<br />THE LIMIT OF SCOPE.
<br />6. THESE DRAWINGS ARE BASED ON FIELD OBSERVATION AND DOCUMENTS
<br />FURNISHED BY THE OWNER. THE ARCHITECT SHALL BE NOTIFIED
<br />IMMEDIATELY BY THE CONTRACTOR OF ANY DISCREPANCIES OR OTHER
<br />QUESTIONS PERTAINING TO THE CONTRACT DOCUMENTS.. IF OBVIOUS
<br />OMISSIONS OR CONTRADICTORY SITUATIONS IN THE CONTRACT DOCUMENTS
<br />ARE DISCOVERED TO EXIST, THEY SHOULD BE IMMEDIATELY CALLED TO THE
<br />ATTENTION OF ARCHITECT FOR CLARIFICATION.
<br />7. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE UNLESS OTHERWISE
<br />NOTED BY A PLUS/MINUS DIMENSION. DETAILED DRAWINGS HAVE
<br />PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK
<br />ACCURACY OF DIMENSIONS ON PLANS WITH ACTUAL FIELD DIMENSIONS. THE
<br />CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS WHICH
<br />PREVENT THE PROPER EXECUTION OF ITS WORK. CONTRACTOR SHALL NOT
<br />START ANY CONSTRUCTION OR ANY OFF-SITE FABRICATION OF MATERIALS
<br />UNTIL THE DRAWINGS DIMENSIONS ARE VERIFIED WITH ACTUAL FIELD
<br />CONDITIONS. DO NOT SCALE DRAWINGS.
<br />8. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY
<br />ERRORS, DISCREPANCIES OR OMISSIONS THAT THE CONTRACTOR FAILED TO
<br />NOTIFY THE ARCHITECT OF BEFORE CONSTRUCTION AND/OR FABRICATION OF
<br />THE WORK.
<br />9. WORK INCLUDES DEMOLITION, REMOVAL AND REINSTALLATION WHERE
<br />REQUIRED. REMOVE, REVISE, RELOCATE AND REINSTALL AS REQUIRED.
<br />10. IT IS NOT THE RESPONSIBILITY OF THE ARCHITECT OR GENERAL CONTRACTOR
<br />TO ENSURE THAT AREAS OF THE BUILDING, NOT DESCRIBED WITHIN THE
<br />SCOPE OF THIS PROJECT COMPLY WITH CURRENT CALIFORNIA BUILDING
<br />CODES, LOCAL CODES AND ORDINANCES (ORD. NO. 2024-05) . IT IS THE
<br />RESPONSIBILITY OF THE OWNER TO MAINTAIN THE BUILDING, SO AS TO
<br />PROVIDE FOR THE SAFETY AND COMFORT OF THE OCCUPANTS. THIS
<br />INCLUDES ALL LIFE SAFETY FEATURES SUCH AS FIRE ALARM, FIRE-
<br />SPRINKLERS, NURSE CALL, EXIT ENCLOSURE, HANDICAP ACCESSIBILITY, ETC..
<br />THIS ALSO INCLUDES MAINTAINING THE BUILDING FREE OF HAZARDOUS
<br />MATERIALS I.E., CHEMICALS AS DESCRIBED BY STATE OR FEDERAL AGENCIES
<br />AS "HAZARDOUS", INCLUDING ASBESTOS.
<br />1. THE CONTRACTOR SHALL INSTALL A VISUAL BARRIER (E.G., GREEN MESH FABRIC)
<br />ALONG THE PERIMETER OF CONSTRUCTION SITES FOR VERTICAL CONSTRUCTION
<br />PROJECTS. THIS REQUIREMENT SHALL BE SUBMITTED TO ARCHITECT AS A
<br />CONTRACTOR SUBMITTAL AND VERIFIED BY THE COMMUNITY DEVELOPMENT
<br />DEPARTMENT PRIOR TO SITE WORK.
<br />2. DUST CONTROL. THE CONTRACTOR SHALL BE REQUIRED TO COMPLY WITH
<br />SCAQMD RULES 402 AND 403, WHICH SHALL ASSIST IN REDUCING SHORT-TERM AIR
<br />POLLUTANT EMISSIONS. SCAQMD RULE 402 REQUIRES THAT AIR POLLUTANT
<br />EMISSIONS NOT BE A NUISANCE OFF SITE. SCAQMD RULE 403 (TABLES 1, 2, AND 3
<br />OF RULE 403) REQUIRES THAT FUGITIVE DUST BE CONTROLLED WITH THE BEST
<br />AVAILABLE CONTROL MEASURES SO THAT THE PRESENCE OF SUCH DUST DOES
<br />NOT REMAIN VISIBLE IN THE ATMOSPHERE BEYOND THE PROPERTY LINE OF THE
<br />EMISSION SOURCE. THIS REQUIREMENT SHALL BESUBMITTED TO ARCHITECT AS A
<br />CONTRACTOR SUBMITTAL AND VERIFIED BY THE COMMUNITY DEVELOPMENT
<br />DEPARTMENT PRIOR TO SITE WORK.
<br />3. ARCHITECTURAL COATINGS. ARCHITECTURAL COATINGS SHALL BE SELECTED SO
<br />THAT THE VOC CONTENT OF THE COATINGS IS COMPLIANT WITH SCAQMD RULE
<br />1113. THIS REQUIREMENT SHALL BE SUBMITTED TO THE ARCHITECT AS A
<br />CONTRACTOR SUBMITTAL AND VERIFIED BY THE COMMUNITY DEVELOPMENT
<br />DEPARTMENT PRIOR TO COATING WORK.
<br />4. CONTRACTOR TO REDUCE PROJECT CONSTRUCTION AIR QUALITY IMPACTS
<br />DURING CONSTRUCTION. THE FOLLOWING TO BE IMPLEMENTED BY CONTRACTOR
<br />DURING CONSTRUCTION:
<br />CONSTRUCTION ACTIVITIES INCLUDING ADDITIONS, ALTERATIONS, AND DEMOLITIONS
<br />SHALL PROVIDE PEDESTRIAN PROTECTION PURSUANT TO SECTION 3306 OF THE
<br />CALIFORNIA BUILDING CODE. TO DETERMINE THE TYPE OF PROTECTION REQUIRED
<br />FOR PEDESTRIANS,MEASURE THE ULTIMATE HEIGHT OF CONSTRUCTION WITH
<br />CONSIDERATION FOR BUILDING SETBACKS AND PROJECTIONS FROM THE BUILDING.
<br />FOR SLOPING SITES, MEASURE THE HEIGHT OF THE BUILDING FROM CONSTRUCTION
<br />EDGE OF THE WALKWAY AND THE SETBACK DISTANCE BETWEEN THE WALKWAY AND
<br />THE BUILDING LINE.
<br />BELOW ARE REQUIREMENTS TO BE ADDRESSED IN THE DESIGN OF PEDESTRIAN
<br />PROTECTIONS:
<br />1. WALKWAYS SHALL PROVIDE SUFFICIENT WIDTH WITH THE MINIMUM OF 4 FT.
<br />CLEAR.
<br />2. DIRECTIONAL BARRICADES SHELL BE PROVIDED AS NEEDED WHERE THE
<br />WALKWAY EXTENDS INTO THE STREET.
<br />3. CONSTRUCTION RAILINGS SHALL BE AT LEAST 42 INCHES IN HEIGHT.
<br />4. BARRIERS SHALL BE A MINIMUM OF 8 FT. IN HEIGHT AND BE DESIGNED TO RESIST
<br />LOADS REQUIRED.
<br />5. SUCH PROTECTION SHALL BE MAINTAINED IN PLACE AND KEPT IN GOOD ORDER.
<br />UNTIL WORK IS COMPLETED.
<br />6. WHENEVER A WALKWAY MUST EXTEND INTO THE ROADWAY, A RAILING IS
<br />REQUIRED ON THE STREET SIDE.
<br />7. CONSTRUCTION STAFF TO ENTER PREMISES THROUGH REAR ENTRANCE.
<br />A. THE CONTRACTORS SHALL PROVIDE AND COORDINATE THE EXACT
<br />DIMENSIONS SIZES AND POSITIONS OF ALL SYSTEMS, EQUIPMENT,
<br />MOUNTING, AND ATTACHMENTS RELATING TO THE WORK.
<br />B. THE CONTRACTOR SHALL PROVIDE AND COORDINATE ALL DIMENSIONS
<br />SIZES AND POSITIONS OF OPENINGS IN SLABS AND WALLS NECESSARY TO
<br />THE INSTALLATION OF THE WORK.
<br />C. ALL EQUIPMENT, CONTROLS AND TERMINATIONS SHALL BE POSITIONS FOR
<br />SAFE, DIRECT AND EASY ACCESS.
<br />D. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH
<br />THE APPROVED DRAWINGS BEFORE PROCEEDING WITH INSTALLATION OF
<br />CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WORK.
<br />SHOULD THERE BE ANY DISCREPANCIES BETWEEN THE ARCHITECT'S AND
<br />THE ENGINEER'S DRAWINGS AND SPECIFICATIONS THAT WOULD CAUSE A
<br />CONFLICT. IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR
<br />CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK
<br />INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE
<br />CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL
<br />EXPENSE TO THE OWNER OR ARCHITECT.
<br />E. CONTRACTOR SHALL COORDINATE WORK WITH HVAC, MECHANICAL,
<br />ELECTRICAL, PLUMBING, DESIGN BUILD FIRE PROTECTION AND
<br />STRUCTURAL DRAWINGS AND REPORT TO IDS GROUP ANY DISCREPANCIES
<br />FOR CORRECTION AND ADJUSTMENT PRIOR TO START OF WORK. NO
<br />ALLOWANCE WILL BE MADE FOR INCREASED COST DUE TO THE
<br />CONTRACTOR’S LACK OF COORDINATION.
<br />A. WATER ACTIVE SITES AT LEAST TWICE DAILY.
<br />B. APPLY WATER THREE TIMES DAILY, OR NON-TOXIC SOIL STABILIZERS
<br />ACCORDING TO MANUFACTURERS' SPECIFICATIONS, TO ALL UNPAVED
<br />PARKING OR STAGING AREAS OR UNPAVED ROAD SURFACES.
<br />C. ALL TRUCKS HAULING DIRT, SAND, SOIL, OR OTHER LOOSE MATERIALS ARE
<br />TO BE COVERED.
<br />D. PAVE ROAD AND ROAD SHOULDERS.
<br />E. INSTALL WHEEL WASHERS WHERE VEHICLES ENTER AND EXIT THE
<br />CONSTRUCTION SITE ONTO PAVED ROADS OR WASH OFF TRUCKS AND ANY
<br />EQUIPMENT LEAVING THE SITE EACH TRIP.
<br />F. APPLY NON-TOXIC SOIL STABILIZERS ACCORDING TO MANUFACTURERS'
<br />SPECIFICATIONS TO ALL INACTIVE CONSTRUCTION AREAS (PREVIOUSLY
<br />GRADED AREAS INACTIVE FOR TEN DAYS OR MORE).
<br />G. SUSPEND ALL EXCAVATING AND GRADING OPERATIONS WHEN WIND
<br />SPEEDS(AS INSTANTANEOUS GUSTS) EXCEED 25 MILES PER HOUR.
<br />H. SWEEP STREETS AT THE END OF THE DAY IF VISIBLE SOIL IS CARRIED ONTO
<br />ADJACENT PUBLIC PAVED ROADS.
<br />I. APPOINT A CONSTRUCTION RELATIONS OFFICER TO ACT AS A COMMUNITY
<br />LIAISON CONCERNING ON-SITE CONSTRUCTION ACTIVITY, INCLUDING
<br />RESOLUTION OF ISSUES RELATED TO PM10 GENERATION.
<br />J. REQUIRE ALL VEHICLES AND EQUIPMENT TO BE PROPERLY TUNED AND
<br />MAINTAINED ACCORDING TO MANUFACTURERS' SPECIFICATIONS.
<br />A. WINDOWS: ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE WELL
<br />FITTED, WELL WEATHER-STRIPPED ASSEMBLIES AND SHALL HAVE A MIN.
<br />UPGRADED SOUND TRANSMISSION CLASS (STC) RATING OF 30 FOR ALL
<br />RESIDENTIAL UNITS WITHIN THE PROJECT BUILDING.
<br />B. DOORS: ALL EXTERIOR DOORS SHALL BE WELL WEATHER-STRIPPED SOLID
<br />CORE ASSEMBLIES AT LEAST ONE AND THREE-FOURTH-INCH THICK.
<br />C. WALLS: AT ANY PENETRATIONS OF EXTERIOR WALLS BY PIPES, DUCTS, OR
<br />CONDUITS, THE SPACE BETWEEN THE WALL AND PIPES, DUCTS, OR
<br />CONDUITS SHALL BE CAULKED OR FILLED WITH MORTAR TO FOR AN AIRTIGHT
<br />SEAL.
<br />D. ROOF: ROOF SHEATHING OF WOOD CONSTRUCTION SHALL BE WELL FITTED
<br />OR CAULKED PLYWOOD OF AT LEAST 1/2" THICK. CEILING SHALL BE WELL
<br />FITTED, FULLY SEALED GYPSUM BOARD OF AT LEAST 1/2" THICK. INSULATION
<br />WITH AT LEAST A RATING OF R-19 SHALL BE USED IN THE ATTIC SPACE.
<br />E. VENTILATION: ARRANGEMENTS FOR ANY HABITABLE ROOM SHALL BE SUCH
<br />THAT ANY EXTERIOR DOOR OR WINDOW CAN BE KEPT CLOSED WHEN THE
<br />ROOM IS IN USE AND STILL RECEIVE CIRCULATED AIR. A FORCED AIR
<br />CIRCULATION SYSTEM (E.G. AIR CONDITIONING) OR ACTIVE VENTILATION
<br />SYSTEM (E.G. FRESH AIR SUPPLY) SHALL BE PROVIDED WHICH SATISFIES THE
<br />REQUIREMENTS OF THE UNIFORM BUILDING CODE.
<br />8. CONTRACTOR TO SUBMIT EVIDENCE TO THE ARCHITECT AND OWNER THAT THE
<br />FOLLOWING NOISE REDUCTION MEASURES AS STATED ON THE CONSTRUCTION
<br />PLANS AND SPECIFICATIONS ARE BEING IMPLEMENTED:
<br />A. CONSTRUCTION TRAFFIC SHALL BE LIMITED TO HAUL ROUTES ESTABLISHED
<br />BY THE LOCAL CITY ORDINANCE.
<br />B. STATIONARY EQUIPMENT (SUCH AS GENERATORS AND AIR COMPRESSORS)
<br />SHALL BE LOCATED AS FAR FROM RESIDENCES, INCLUDING HOTEL ROOMS,
<br />AS FEASIBLE.
<br />C. EQUIPMENT MAINTENANCE AND STAGING AREAS SHALL BE LOCATED AS FAR
<br />AWAY FROM RESIDENCES AS FEASIBLE.
<br />D. CONSTRUCTION EQUIPMENT SHALL BE FITTED WITH MANUFACTURER'S
<br />STANDARD, OR BETTER, NOISE-SHIELDING AND MUFFLING DEVICES TO
<br />REDUCE NOISE LEVELS TO THE MAXIMUM EXTENT FEASIBLE.
<br />E. THE PROJECT OWNER/DEVELOPER SHALL DESIGNATE A CONSTRUCTION
<br />COMPLAINT MANAGER FOR THE PROJECT. A TELEPHONE CONTACT NUMBER
<br />SHALL BE CLEARLY POSTED AT ALL ACTIVE ACCESS POINTS.
<br />5. NOISE GENERATING: CONSTRUCTION, REPAIR, REMODELING, OR GRADING IS
<br />ALLOWED, PROVIDED IT DOES NOT OCCUR BETWEEN 8:00 P.M. AND 7:00 A.M. ON
<br />WEEKDAYS (INCLUDING SATURDAY) OR AT ANY TIME ON A SUNDAY OR FEDERAL
<br />HOLIDAY
<br />6. CONTRACTOR TO INSTALL WINDOW ASSEMBLIES THAT ARE TESTED AND
<br />CERTIFIED TO PREVENT THE INTRUSION OF EXTERIOR NOISE SO THAT THE
<br />INTERIOR NOISE LEVEL WITH WINDOWS CLOSED, ATTRIBUTABLE TO EXTERIOR
<br />SOURCES, SHALL NOT EXCEED 45 DBA CNEL IN ANY HABITABLE ROOM. THIS
<br />REQUIREMENT SHALL BE SUBMITTED TO ARCHITECT AS A CONTRACTOR
<br />SUBMITTAL.
<br />7. PER CITY ORDINANCE, CONTRACTOR TO SATISFY CITY GUIDELINES OF 45 DBA
<br />CNEL INTERIOR NOISE LEVEL STANDARD, ALL UNITS WILL REQUIRED A MIN.
<br />EXTERIOR TO INTERIOR NOISE REDUCTION (NR) OF UP TO 23.8 DBA AND A
<br />WINDOWS CLOSED CONDITION REQUIRING A MEANS OF MECHANICAL
<br />VENTILATION (E.G. AIR CONDITIONING). IN ORDER TO MEET THE CITY GUIDELINES
<br />OF 45 DBA CNEL INTERIOR NOISE STANDARDS THE PROJECT SHALL PROVIDE THE
<br />FOLLOWING NOISE MITIGATION MEASURES:1. EXIT DOORS SHALL BE OF THE PIVOTED OR IDE-HINGEDSWINGING TYPE. EXIT
<br />DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL W HEN THE AREA SERVED
<br />HAS AN OCCUPANT LOAD OF 50 OR MORE.
<br />2. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A
<br />KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. NOTE ALSO THAT FLUSH BOLTS
<br />OR SURFACE BOLTS ARE PROHIBITED.
<br />3. PANIC HARDWARE SHALL BE PROVIDED ON EXIT DOORS OF ROOMS, CORRIDORS,
<br />STAIRWAYS, HANDLING AN OCCUPANT CAPACITY OF 50 OR MORE PERSONS.
<br />4. EXIT SIGNS SHALL BE INSTALLED AT REQUIRED EXIT DOORWAYS AND WHERE
<br />OTHERWISE NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS IN
<br />COMPLIANCE WITH THE CODE OF JURISDICTION.
<br />5. THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS,
<br />OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS. THESE FORCES DO NOT
<br />APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE
<br />OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FOR OTHER
<br />SWINGING DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH
<br />SHALL RELEASE WHEN SUBJECTED TO A 15-POUND FORCE. THE DOOR SHALL BE
<br />SET IN MOTION WHEN SUBJECTED TO A 30-POUND FORCE. THE DOOR SHALL
<br />SWING TO A FULL-OPEN POSITION WHEN SUBJECTED TO A 15-POUND FORCE.
<br />FORCES SHALL BE APPLIED TO THE LATCH SIDE OF THE DOOR.
<br />6. EACH DOOR IN A MEANS OF EGRESS FROM A GROUP 'A' OCCUPANCY SHALL NOT
<br />BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE OR FIRE
<br />EXIT HARDWARE (CBC 1008.1.9).
<br />7. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A
<br />MIN. 34" AND A MAX. 44" A.F.F.
<br />8. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL
<br />PROVIDE AN ILLUMINATION OF NOT LESS THAT 90min. IN CASE OF PRIMARY POWER
<br />LOSS (CBC 1011.2 - 1011.5.3)
<br />9. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED
<br />AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS
<br />OCCUPIED.
<br />1. FURNISH AND INSTALL SUPPORTS AND OTHER NECESSARY FINISH MATERIALS FOR
<br />A COMPLETE SIGNAGE INSTALLATION.
<br />2. HANDICAPPED SIGNAGE / IDENTIFICATION
<br />A. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD
<br />USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USEABLE BY
<br />PHYSICALLY HANDICAPPED PERSONS.
<br />B. LETTERS AND NUMBERS ON SIGNS HAVE A WIDTH TO HEIGHT RATIO OF
<br />BETWEEN 3:5 AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO OF BETWEEN 1:5
<br />AND 1:10.
<br />C. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND,
<br />EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS
<br />ON A LIGHT BACKGROUND.
<br />D. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY
<br />PHYSICALLY HANDICAPPED PERSONS SHALL BE IDENTIFIED WITH AT LEAST
<br />ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED
<br />TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS.
<br />E. ALL SANITARY FACILITIES WILL BE PROVIDED WITH APPROPRIATE
<br />IDENTIFICATION SYMBOLS.
<br />1. ALL GLAZING SHALL COMPLY WITH C.P.S.C. 16 C.F.R. AND CBC.
<br />2. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS SHALL BE
<br />APPROVED FOR IMPACT HAZARD PER C.B.C. SECTION 2406. PROVIDE
<br />IDENTIFICATION OF GLAZING PER SECTION 2406.2
<br />3. PROVIDE TEMPERED GLASS AS REQUIRED BY CBC SECTION 2406 AND BY OTHER
<br />APPLICABLE CODES.
<br />1. MECHANICAL DUCTS, ETC. PENETRATING FIRE-RATED CEILINGS AND FIRE WALLS
<br />SHALL BE CORRESPONDINGLY RATED OR DAMPERED. CABINETS, ELECTRICAL
<br />PANELS, LIGHTS, ETC. RECESSED INTO FIRE RATED WALLS OR CEILINGS SHALL BE
<br />BACKED WITH CORRESPONDING FIRE-RESISTIVE CONSTRUCTION AS REQUIRED TO
<br />MAINTAIN THE INTEGRITY OF THE FIRE PROTECTION.
<br />2. FIRE RESISTIVE ASSEMBLIES FOR PROTECTION OF OPENINGS SHALL COMPLY WITH
<br />CBC CHAPTER 7.
<br />3. PENETRATION OF FIRE RATED ASSEMBLIES WHICH REQUIRE OPENING
<br />PROTECTION SHALL BE FIRE STOPPED. FIRE STOPPING SHALL BE IDENTICAL TO AN
<br />APPROVED UNDERWRITERS LABORATORIES (UL) LISTED ASSEMBLY WITH AN "F" OF
<br />"T" RATING. PENETRATIONS MUST ALSO CONSIST OF APPROVED MATERIALS FOR
<br />THROUGH WALL PENETRATIONS FIRE STOP SYSTMEMS AS PRESCRIBED IN CBC
<br />STANDARD 7-5 FIRE RATING FOR FIRE STOP SYSTEMS SHALL BE EQUAL TO THE
<br />ASSEMBLY PENETRATED. (709.6, CBC)
<br />4. SHAFT ENCLOSURES: OPENINGS EXTENDING VERTICALLY THROUGH FLOORS
<br />SHALL BE ENCLOSED IN A SHAFT OF 1-HOUR FIRE-RESISTIVE CONSTRUCTION IF
<br />PENETRATING A 1-HOUR FIRE RATED FLOOR ASSEMBLY. SHAFTS SHALL INCLUDE
<br />A GYPSUM BOARD HORIZONTAL TERMINATION AT BOTTOM, ENGINEERED BY
<br />GENERAL CONTRACTOR. PROTECTION FOR STAIRWAYS SHALL BE AS SPECIFIED IN
<br />CODE OF JURISDICTION.
<br />3. AREA AND OCCUPANCY SIGNAGE REQUIREMENTS OCCUPANT LOAD SIGN SHALL BE
<br />POSTED IN EACH MEETING ROOM, ASSEMBLY ROOM OR SIMILAR PURPOSE ROOM
<br />HAVING AN OCCUPANT LOAD OF 50 OR MORE.
<br />4. EXIT SIGNS SHALL BE POSTED OVER EXITS DOORS SERVING 50 OR MORE AND ALL
<br />HAZARDOUS AREAS. MINIMUM LETTER HEIGHT IS 6" AND SHALL CONFORM WITH CBC
<br />AND LOCAL CODES. CBC SECTION 1003.2.8 AND UFC SECTION 12113A. SEE
<br />ELECTRICAL PLANS FOR LOCATIONS AND FURTHER INFO.
<br />5. AN APPROVED SIGN SHALL BE LOCATED AT EACH FLOOR LEVEL LANDING IN ALL
<br />ENCLOSED STAIRWAYS. THE SIGN SHALL INDICATE FLOOR LEVEL, TERMINUS OF THE
<br />TOP AND BOTTOM OF THE STAIRWAY, AND THE IDENTIFICATION OF THE STAIRWAY.
<br />1. THE CONTRACTOR SHALL IN THE WORK OF ALL TRADES, PERFORM ALL CUTTING,
<br />PATCHING, REPAIRING, RESTORING AND THE LIKE NECESSARY TO COMPLETE
<br />THE WORK AND TO RESTORE ANY DAMAGED OR AFFECTED SURFACES
<br />RESULTING FROM THE WORK OF THIS CONTRACT TO THEIR ORIGINAL CONDITION
<br />TO THE SATISFACTION OF THE OWNERS AND THE ARCHITECT.
<br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, PATCHING,
<br />AND FIRE SAFING METHODS REQUIRED TO COMPLETE THE WORK INCLUDING BUT
<br />NOT LIMITED TO THE FOLLOWING:
<br />A. UNCOVERED PORTIONS OF THE WORK USED TO PROVIDE FOR
<br />INSTALLATION OF UNSCHEDULED WORK.
<br />B. REMOVE AND REPLACE DEFECTIVE WORK.
<br />C. REMOVE AND REPLACE WORK NOT CONFORMING TO REQUIREMENTS OF
<br />CONTRACT DOCUMENTS.
<br />D. PROVIDE ROUTINE PENETRATIONS OF NON-STRUCTURAL SURFACES FOR
<br />INSTALLATION OF PIPING AND ELECTRICAL CONDUIT.
<br />E. REMOVE EXISTING WORK INDICATED IN THE DOCUMENTS AND AS MAY BE
<br />REQUIRED TO PERMIT THE PROPER INSTALLATION OF NEW WORK THAT
<br />FORMS PART OF HIS CONTRACT. ALL CUTTING,REPAIRING AND/OR PATCHING
<br />NECESSARY IN CONNECTION WITH SUCH REMOVALS SHALL BE DONE
<br />WITHOUT EXTRA CHARGE, WHETHER OR NOT EVERY ITEM MAY BE
<br />SPECIFICALLY DESCRIBED.
<br />3. PROCEDURES FOR NON-STRUCTURAL CUTTING AND PATCHING:
<br />A. PROVIDE ADEQUATE TEMPORARY SUPPORT AS NECESSARY TO ASSURE THE
<br />STRUCTURAL VALUE INTEGRITY OF THE AFFECTED PORTION OF THE WORK.
<br />B. PROVIDE DEVICES AND METHODS TO PROTECT OTHER PORTIONS OF THE
<br />PROJECT FROM DAMAGE.
<br />C. PROVIDE PROTECTION FROM THE ELEMENTS FOR THAT PORTION OF THE
<br />PROJECT WHICH MAY BE EXPOSED BY CUTTING AND PATCHING WORK.
<br />D. EXECUTE CUTTING BY METHODS WHICH WILL PREVENT DAMAGE TO OTHER
<br />WORK, AND WILL PROVIDE PROPER SURFACES TO RECEIVE INSTALLATION OR
<br />REPAIRS.
<br />E. EXECUTE FITTING AND ADJUSTMENT OF PRODUCTS TO PROVIDE A
<br />FINISHED INSTALLATION TO COMPLY WITH SPECIFIED PRODUCTS,
<br />FUNCTIONS, TOLERANCES AND FINISHES, AND MANUFACTURER'S CRITERIA.
<br />F. RESTORE WORK WHICH HAS BEEN CUT OR REMOVED. INSTALL NEW
<br />PRODUCTS TO PROVIDE COMPLETE WORK IN ACCORDANCE WITH
<br />REQUIREMENTS OF CONTRACT DOCUMENTS.
<br />G. REFINISH ENTIRE SURFACE AS NECESSARY TO PROVIDE AN EVEN FINISH
<br />TO MATCH ADJACENT FINISHES.
<br />CUTTING AND PATCHING
<br />INSTRUMENT OF SERVICE CONTRACTOR OBLIGATIONS
<br />EXITS
<br />DOORS
<br />1. DOORS IN RATED WALLS SHALL CONSIST OF SELF-CLOSING, SELF-LATCHING
<br />ASSEMBLIES WITH SMOKE AND DRAFT SEALS AT HEAD AND JAMBS. DOOR
<br />ASSEMBLY RATINGS SHALL BE AS INDICATED ON DOOR SCHEDULE. HOLD OPEN
<br />DEVICES ON RATED ASSEMBLIES SHALL BE MAGNETICALLY OPERATED AND
<br />ACTIVIATED BY SMOKE DETECTORS.
<br />2. DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR
<br />THRESHOLDS, ECT., SHALL BE TAKEN OFF THE DOOR. DOORS AND FRAMES
<br />SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS, AND
<br />HARDWARE.
<br />3. AIR LEAKAGE AT EXTERIOR DOORS SHALL BE LIMITED BY THE FOLLOWING:
<br />A. ALL DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE AT THE
<br />HEAD AND SILL.
<br />B. DOORS MOUNTED ON EITHER THE INSIDE OR OUTSIDE OF AN EXTERIOR WALL
<br />SHALL HAVE A MINIMUM 1/2" LAP AT EACH JAMB.
<br />C. DOORS REQUIRING VERTICAL TRACK OR GUIDES SHALL USE A CONTINUOUS
<br />MOUNTING ANGLE, SEALED IN ACCORDANCE WITH "G" LISTED HERE.
<br />D. DOORS MOUNTED BETWEEN THE JAMBS SHALL HAVE A CONTINUOUS SEAL OR
<br />BAFFLE AT EACH JAMB.
<br />E. MEETING RAILS OR SECTION DOORS AND MEETING STILES OR RAILS OR BI-
<br />PARTING DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE.
<br />F. SWINGING AND REVOLVING DOORS SHALL BE WEATHERSTRIPPED AT THE
<br />HEAD, SILL AND JAMBS.
<br />G. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN
<br />WALL AND FOUNDATIONS, BETWEEN WALL AND ROOF, BETWEEN WALL
<br />PANELS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS
<br />AND ROOFS AND ALL OTHER OPENINGS IN THE EXTERIOR ENVELOPE SHALL
<br />BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR
<br />LEAKAGE.
<br />WOOD WORK
<br />1. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE
<br />FLUSH. IF STRUCTURAL PANELS ARE REQUIRED ON A WALL PLANE, THE ENTIRE
<br />WALL PLANE SHALL BE FURRED OR FINISHED FLUSH.
<br />2. INSTALL METAL CORNER BEADS AT ALL EXPOSED WALLBOARD EDGES. INSTALL
<br />CASING BEADS WHEREVER WALLBOARD, PLASTER, ETC. ABUTS A DISSIMILAR
<br />FINISH MATERIAL AND PROVIDE SEALANT AS REQUIRED.
<br />3. GYPSUM BOARD SHALL EXTEND TO UNDERSIDE OF STRUCTURE ABOVE AT ALL
<br />EXTERIOR PERIMETER WALLS
<br />1. THE CONSTRUCTION OR DEMOLITION OF ANY BUILDING, STRUCTURE, SCAFFOLDING
<br />OR FALSEWORK MORE THAN 3 STORIES OR 36'-0" IN HEIGHT, REQUIRES A PERMIT
<br />FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY PRIOR TO THE
<br />ISSUANCE OF A BUILDING PERMIT. ( 1PC.B.9 )
<br />2. A SEPARATE INTERIOR IMPROVEMENT PERMIT IS REQUIRED FOR ANY TENANT
<br />IMPROVEMENT IN THIS BUILDING.
<br />3. A PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS IS REQUIRED FOR A
<br />PROTECTION FENCE OR CANOPY ON OR OVER ANY STREET OR PUBLIC SPACE.
<br />PROTECTION OF PEDESTRIANS DURING CONSTRUCTION SHALL BE PROVIDED PER
<br />C.B.C. SECTION 3303.
<br />4. ALL ROOMS ARE REQUIRED TO BE MARKED WITH APPROVED SIGNAGE.
<br />5. OBTAIN PERMIT FROM CITY ENGINEER PRIOR TO DOING ANY SIDEWALK AND CURB
<br />WORK.
<br />6. SEPARATE PERMITS SHALL BE OBTAINED FOR SIGNS, FENCES, TRASH ENCLOSURES,
<br />RETAINING WALLS, PLANTERS, AND POOLS.
<br />7. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND
<br />SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. REFER TO
<br />SHEET G-001 FOR LIST OF DEFERRED SUBMITTALS.
<br />8. ALL LEVELS REFERENCE POINTS ABOVE PODIUM LEVEL ARE TAKEN FROM TOP OF
<br />SHEATHING. DIMENSIONS ON ELEVATIONS, SECTIONS AND WALL SECTIONS ARE
<br />REFERENCED TO THESE POINTS, UNLESS NOTED.
<br />PERMIT
<br />GENERALCONTRACTOR MITIGATION OBLIGATIONS
<br />MONITORING AND REPORTING PROGRAM
<br />CODES
<br />1. CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA BUILDING CODE,
<br />ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS
<br />AND PROTECTIVE COVENANTS GOVERNING THE WORK. IN CASE OF CONFLICTS, THE
<br />MORE STRINGENT REQUIREMENT SHALL GOVERN.
<br />SIGNAGES
<br />FIELD APPLICATION OF PEDESTRIAN
<br />PROTECTION:
<br />GLAZING
<br />RATED ASSEMBLY PENETRATIONS
<br />DESIGNATED CONSTRUCTION MANAGER TO BE PHIL LEVESQUE (714) 483-3915.
<br />CONSTRUCTION MANAGER TO BE INVITED TO ALL WEEKLY PROJECT MEETINGS
<br />TO VERIFY QUALITY CONTROL MEASURES AND SCHEDULE.
<br />LICENSED A RCHITECT
<br />SAMUEL
<br />PIPER
<br />C-39936
<br />RENEWAL
<br />DATE
<br />STATEOF C A LIFORNIA12/31/27
<br />17595 HARVARD AVE, SUITE C
<br />IRVINE, CA. 92614
<br />TEL: 707.815.6742
<br />PROJECT NO.
<br />DRAWN BY
<br />CHECKED BY
<br />APPROVED BY
<br />PROJECT IDENTIFICATION
<br />THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
<br />THESE DRAWINGS AND SPECIFICATIONS ARE THE
<br />PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
<br />AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
<br />LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
<br />WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
<br />STAMP
<br />STAMP
<br />ARCHITECT ON RECORD
<br />CLIENT
<br />SHEET TITLE
<br />SHEET NUMBER
<br />APPROVAL
<br />PL
<br />O
<br />T
<br />
<br />D
<br />A
<br />T
<br />E
<br />:
<br />
<br />U
<br />S
<br />E
<br />R
<br />:
<br />128 W MACARTHUR BLVD, SANTA ANA,
<br />CA 92707
<br />THE NOODLE LOFT
<br />ISSUE
<br />SP
<br />SP
<br />SANDPIPER
<br />ARCHITECTURE
<br />4/
<br />1
<br />6
<br />/
<br />2
<br />0
<br />2
<br />6
<br />
<br />2
<br />:
<br />1
<br />8
<br />:
<br />2
<br />3
<br />
<br />P
<br />M
<br />G-101
<br />GENERAL NOTES
<br />2510
<br />Au
<br />t
<br />h
<br />o
<br />r
<br />REV DESCRIPTION DATE
<br />A UPLOAD 12/02/2026
<br />B HEALTH SUB 2 02/04/2026
<br />2 PLAN RESUBMITTAL 04/06/2026
|