My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
423 S Center St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Center St
>
423 S Center St
>
423 S Center St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 5:00:16 AM
Creation date
5/19/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101124253
101126689
Full Address
423 S Center St
Street Number
423
Street Direction
S
Street Name
Center
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />1. PROVIDE FIRE BLOCKING IN CONCEALED SPACES 10' O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR LEVELS, <br />CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS <br />AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES, CRC R302.11. <br />2. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" <br />TO THE EXPOSED GROUND SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY, CRC R317.2(2). <br />3. ALL WALLS TO BE SMOOTH FINISH U.N.O. <br />4. CONTRACTOR TO INCLUDE ALL FINISH AND COLOR SPECIFIED BY OWNER AND INTERIOR DESIGNER. <br />5. CONTRACTOR TO VERIFY W/ OWNER'S INTERIOR DESIGNER FOR MATERIAL SELECTION AND COLOR PRIOR TO FINAL PRICING AND <br />CONSTRUCTION. <br />6. MIN. 3/8" CDX PLYWOOD THROUGH-OUT @ OUTSIDE FACE OF WALL. <br />7. CONTRACTOR TO INCLUDE INSULATION OF CLOSET ORGANIZER. (SELECTED BY OWNER). <br />8. CONTRACTOR TO VERIFY ALL OWNER'S APPLIANCE MANUAL SPEC. PRIOR TO CONSTRUCTION. <br />9. DESIGN BUILT CABINET TO FIT. <br />10. ALL INTERIOR, DOOR, WINDOW SIDE, HEAD AND SILL TO BE MOLDING. <br />11. EXTERIOR CONCRETE LANDING TO COMPLY 2022 CRC R311.3 <br />A. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE <br />NOT LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A DIMENSION OF NOT LESS THAN 36 <br />INCHES MEASURED IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR <br />LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT). <br />B. LANDINGS AT THE REQUIRED DOOR SHALL NOT MORE THAN 1 1/2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. <br />EXCEPTION: THE LANDING SHALL BE <br />NOT MORE THAN 7 3/4 INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER <br />THE LANDING <br />12. GROUND ADJACENT TO THE FOUNDATION SHALL FALL A MINIMUN OF 8 INCHES WITHIN THE FIRST 10 FEET MEASURE <br />PERPENDICULAR TO THE FACE OF THE FOUNDATION WALL. (CRC R401.3) <br />13. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY SIMILAR IN DESIGN, PITCH, COLOR, MATERIAL <br />AND TEXTURE. <br />14. NEW FASCIAS OF ADU/JADU TO MATCH EXISTING ONES. <br />GRADE <br />-0' -8" <br />1ST FF. <br />0' -0" <br />5 <br />01-REV1-A-201 <br />5 <br />01-REV1-A-201 <br />TYP. <br />ADU.TOP PL. <br />9' -0" <br />2'-0" <br />(E) <br />1'-0" <br />3:12 <br />F.S.D <br />3'-0"(N) DETACHED ADU(E) MAINHOUSE <br />3637TYP. <br />1.7 1.3 1.4 <br />1.2 <br />1 <br />70.1 <br />72.1 <br />72 <br />33 <br />ADU. APPX. HEIGHT <br />11' -6" <br />2'-0"1'-0"1'-0" <br />16.1 <br />31 <br />70 <br />31 <br />(N) BUILDING MAX. HEIGHT <br />12'-2" <br />2'-6" <br />CEILING HEIGHT <br />9'-0" <br />8" <br />A <br />GRADE <br />-0' -8" <br />1ST FF. <br />0' -0" <br />6 <br />01-REV1-A-201 <br />6 <br />01-REV1-A-201 <br />ADU.TOP PL. <br />9' -0" <br />CEILING HEIGHT <br />9'-0" <br />8" <br />52'-0" <br />36 <br />16.1 <br />75 <br />N-1 N-B <br />N-2 <br />1'-0"1'-0" <br />7'-6" <br />3'-0"4'-0" <br />3'-6" <br />4'-0" <br />7'-6" <br />16.1 <br />75 <br />TYP.72 <br />ADU. APPX. HEIGHT <br />11' -6" <br />(N) BUILDING MAX. HEIGHT <br />12'-2" <br />7037 <br />1.2 <br />2'-6" <br />5'-0" <br />7'-6" <br />16.1 <br />N-2 <br />5'-0" <br />73 <br />TYP. <br />75 <br />TYP. <br />AA <br />A <br />A <br />GRADE <br />-0' -8" <br />1ST FF. <br />0' -0" <br />6 <br />01-REV1-A-201 <br />6 <br />01-REV1-A-201 <br />TYP.TYP. <br />ADU.TOP PL. <br />9' -0" <br />CEILING HEIGHT <br />9'-0" <br />8" <br />52'-0" <br />37 36 <br />N-C 1.2 <br />31 5'-6" <br />2'-0" <br />3'-0"F.S.D = 3 FT (3' < F.S.D < 5') <br />UNPROTECTED OPENING MAXIMUM 25% <br />WALL AREA <br />WALL AREA = 389 SF; OPENING = 24 SF <br />(24/389)x100% = 6.1% < 25% (OK) <br />72 <br />33 <br />ADU. APPX. HEIGHT <br />11' -6" <br />N-C76 76 <br />3'-0" <br />5'-6" <br />2'-0" <br />1.7 <br />2'-6" <br />(N) BUILDING MAX. HEIGHT <br />12'-2"2'-0" <br />5'-6" <br />6'-0"1'-0"1'-0" <br />N-D <br />73 TYP. <br />70 <br />99 <br />31 <br />31 <br />A <br />AA <br />GRADE <br />-0' -8" <br />GRADE <br />-0' -8" <br />M.H.TOP PL. <br />8' -0" <br />M.H. APPX. HEIGHT <br />14' -0 1/2" <br />1ST FF. <br />0' -0" <br />1ST FF. <br />0' -0" <br />5 <br />01-REV1-A-201 <br />5 <br />01-REV1-A-201 <br />TYP.TYP. <br />ADU.TOP PL. <br />9' -0" <br />1'-0"7"4'-5" <br />8" <br />CEILING HEIGHT <br />9'-0" <br />4'-5" <br />F.S.D <br />1'-7" <br />DISTANCE TO BUILDING <br />6'-0" <br />(N) DETACHED ADU (E) MAINHOUSE <br />3736 <br />3:12 <br />1 <br />70.1 <br />72.1 <br />99 <br />33 <br />ADU. APPX. HEIGHT <br />11' -6" <br />N-A N-A <br />3'-5"1'-0"1'-0" <br />16.1 <br />(N) BUILDING MAX. HEIGHT <br />12'-2" <br />2'-6" <br />EE&RO <br />3'-0"3'-0" <br />2'-6" <br />5'-0" <br />73 <br />72 <br />2'-6" <br />5'-0" <br />TYP.31 <br />A <br />GRADE <br />-0' -8" <br />1ST FF. <br />0' -0" <br />6 <br />01-REV1-A-201 <br />6 <br />01-REV1-A-201 <br />R-15 INSULATION PER T24 <br />ADU.TOP PL. <br />9' -0"R-30 INSULATION PER T24 <br />R-19 INSULATION PER T24 <br />N-3 <br />ADU -LIVING AREA <br />9' 0" CLG <br />WOOD <br />ADU -BATH #2 <br />9' 0" CLG <br />TILE <br />CEILING HEIGHT <br />9'-0" <br />37 TYP.TYP.36 <br />R-15 INSULATION PER T24 <br />81 <br />87 88 <br />89 90 <br />85 <br />ADU. APPX. HEIGHT <br />11' -6" <br />1.2 <br />1.7ADU -KITCHEN & DINING <br />9' 0" CLG <br />WOOD <br />ADU -BEDROOM #1 <br />9' 0" CLG <br />WOOD <br />ADU -BATH #1 <br />9' 0" CLG <br />TILE <br />ADU -BEDROOM #2 <br />70 <br />8080 <br />85 <br />86 <br />99 <br />85 <br />86 <br />N-2 N-1 <br />1'-0"1'-0"85 <br />8" <br />2'-6" <br />(N) BUILDING MAX. HEIGHT <br />12'-2" <br />A <br />GRADE <br />-0' -8" <br />GRADE <br />-0' -8" <br />M.H.TOP PL. <br />8' -0" <br />1ST FF. <br />0' -0" <br />1ST FF. <br />0' -0" <br />5 <br />01-REV1-A-201 <br />5 <br />01-REV1-A-201 <br />91 <br />ADU.TOP PL. <br />9' -0" <br />CEILING HEIGHT <br />9'-0" <br />8" <br />(E) <br />1'-0"2'-0"2'-0" <br />(N) DETACHED ADU(E) MAINHOUSE <br />8'-0" <br />8" <br />R-15 INSULATION PER T24 <br />R-30 INSULATION PER T24 <br />R-19 INSULATION PER T24 <br />R-15 INSULATION PER T24 <br />F.S.D <br />3'-0" <br />F.S.D <br />3'-0" <br />3:12 <br />81 8080 <br />85 <br />85 <br />86 <br />87 88 <br />89 90 <br />81.1 80.1 <br />(E) LIVING <br />VAULTED CLG <br />WOOD <br />33 99 <br />37 <br />70.1 <br />ADU. APPX. HEIGHT <br />11' -6" <br />36 TYP. <br />86 <br />ADU -KITCHEN & DINING <br />9' 0" CLG <br />WOOD <br />N-6N-4 <br />16.1 <br />1'-0" <br />1'-0" <br />31 <br />31 <br />2'-6" <br />(N) BUILDING MAX. HEIGHT <br />12'-2" <br />A <br />2025.03 <br />10.10.2025 <br />©2025Sheet No. <br />Rev. <br />Project No. <br />Date Print: <br />Design by <br />TRINH HA. <br />Date. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />Description. <br />1.07.23.2025Correction 1st. <br />2.09.12.2025Correction 2nd. <br />3.10.20.2025Correction 3rd. <br />A 01.21.2026REVISIONS <br />01-REV1-A-201 <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />- <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />M <br />a <br />i <br />n <br /> <br />H <br />o <br />u <br />s <br />e <br />: <br /> <br />4 <br />2 <br />1 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />70 <br />3 <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />D <br />e <br />t <br />a <br />c <br />h <br />e <br />d <br /> <br />A <br />D <br />U <br />: <br /> <br />4 <br />2 <br />3 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />9 <br />2 <br />7 <br />0 <br />3 <br />PROPOSED ELEVATIONS - <br />SECTIONS <br />ELEVATION & SECTION NOTES <br />ELEVATION & SECTIONS KEYNOTES <br />1 (E) ELECTRICAL METER/PANEL MAINHOUSE, VERIFY SIZE REQUIREMENT w/SUBCONTRACTOR <br />1.2 (N) ELECTRICAL PANEL FOR ADU 200 AMP, WITH A 225A BUS BAR <br />1.3 "(N) 60 AMP SUBPANEL FOR ADU ESS SYSTEM" <br />1.4 (N) ELECTRICAL METER FOR ADU 200 AMP <br />1.7 (N) ELECTRICAL METER FOR MAINHOUSE 200 AMP, RELOCATION <br />16.1 (N) LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN DEPTH. MIN. 2% SLOPE AWAY FROM BUILDING. <br />31 (N) DUCTLESS MINI-SPLIT SYSTEM AC. PER T-24 <br />33 (N) HEAT PUMP WATER HEATERS PER T-24 FOR ADU SHALL BE ENCLOSED BY THE QUICK SHED WATER HEATER OF GALVANIZED <br />STEEL OR EQUAL TO PROVIDE PROTECTION FOR WATER HEATERS INSTALLED IN OUTDOOR LOCATIONS. <br />36 O'HAGIN ROOF VENT <br />37 SOLAR PANELS LOCATION, DESIGN BY OTHER, SEE T-24 <br />70 (N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & TEXTURE TO MATCH <br />EXISTING HOUSE. EQUAL. <br />70.1 (E) ROOF <br />72 STUCCO WALL & PAINT TO MATCH EXISTING <br />72.1 (E) STUCCO WALL <br />73 "(N) 2 1/2"" VINYL MOLDING TRIM FOR ALL WINDOWS TO MATCH EXISTING, TYP." <br />75 TEMPERED GLASS <br />76 "TEMPERED, OBSCURED GLASS" <br />80 (N) FOOTING PER STRUCT. <br />80.1 (E) FOOTING PER STRUCT. <br />81 (N) CONCRETE SLAB PER STRUCT. <br />81.1 (E) CONCRETE SLAB PER STRUCT. <br />85 (N) 2x STUD WALL PER STRUCT. <br />86 WALL INSULATION PER T-24 <br />87 (N) CEILING JOISTS PER STRUCT. <br />88 CEILING INSULATION PER T-24 <br />89 (N) ROOF RAFTER PER STRUCT. <br />90 ROOF INSULATION PER T-24 <br />91 (N) RIDGE BEAM PER STRUCT. <br />99 1HR FIRE-RATED WALL PROVIDE UNPROTECTED OPENING MAX 25% OF WALL AREA, SEE CALCUALTION ON ELEVATION VIEW. <br />1/4" = 1'-0"2PROPOSED ADU EAST ELEVATION <br />1/4" = 1'-0"1PROPOSED ADU NORTH ELEVATION <br />1/4" = 1'-0"3PROPOSED ADU SOUTH ELEVATION <br />1/4" = 1'-0"4PROPOSED ADU WEST ELEVATION <br />1/4" = 1'-0"5PROPOSED - SECTION A-A 1/4" = 1'-0"6PROPOSED - SECTION B-B
The URL can be used to link to this page
Your browser does not support the video tag.