June 18, 2025 <br />59 Ft Monopole Tower Structural Analysis CCI BU No 845404 <br />Project Number 42285-845404-2399694-01-STR, Order 705457, Revision 0 Page 6 <br />tnxTower Report - version 8.3.0.5 <br /> <br /> Tower Input Data <br /> <br /> <br />The tower is a monopole. <br />This tower is designed using the TIA-222-H standard. <br />The following design criteria apply: <br />• Tower is located in Orange County, California. <br />• Tower base elevation above sea level: 185.22 ft. <br />• Basic wind speed of 95 mph. <br />• Risk Category II. <br />• Exposure Category C. <br />• Simplified Topographic Factor Procedure for wind speed-up calculations is used. <br />• Topographic Category: 1. <br />• Crest Height: 0.00 ft. <br />• Deflections calculated using a wind speed of 60 mph. <br />• CCISeismic Note: Seismic loads generated by CCISeismic 5.0.2. <br />• CCISeismic Note: Seismic calculations are in accordance with TIA-222-H-1. <br />• Non-linear (P-delta) analysis was used. <br />• Pressures are calculated at each section. <br />• Stress ratio used in pole design is 1. <br />• Tower analysis based on target reliabilities in accordance with Annex S. <br />• Load Modification Factors used: Kes(Fw) = 0.95, Kes(Ev and Eh) = 1.0. <br />• Maximum demand-capacity ratio is: 1.05. <br />• Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are <br />not considered. <br /> <br /> Options <br /> <br /> Consider Moments - Legs Assume Legs Pinned Calculate Redundant Bracing Forces <br /> Consider Moments - Horizontals √ Assume Rigid Index Plate Ignore Redundant Members in FEA <br /> Consider Moments - Diagonals √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression <br /> Use Moment Magnification Use Clear Spans For KL/r All Leg Panels Have Same Allowable <br />√ Use Code Stress Ratios Retension Guys To Initial Tension Offset Girt At Foundation <br />√ Use Code Safety Factors - Guys √ Bypass Mast Stability Checks √ Consider Feed Line Torque <br /> Escalate Ice √ Use Azimuth Dish Coefficients Include Angle Block Shear Check <br /> Always Use Max Kz √ Project Wind Area of Appurtenances Use TIA-222-H Bracing Resist. Exemption <br /> Kz In Exposure D Hurricane Region √ Alternative Appurt. EPA Calculation Use TIA-222-H Tension Splice Exemption <br /> Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles <br /> Leg Bolts Are At Top Of Section Add IBC .6D+W Combination √ Include Shear-Torsion Interaction <br /> Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Always Use Sub-Critical Flow <br /> Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets <br /> SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder √ Pole Without Linear Attachments <br /> SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole With Shroud Or No Appurtenances <br /> Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Outside and Inside Corner Radii Are Known <br /> Use Special Wind Profile <br /> <br /> Tapered Pole Section Geometry <br /> <br /> Section Elevation <br /> <br />ft <br />Section <br />Length <br />ft <br />Splice <br /> Length <br />ft <br />Number <br />of <br />Sides <br />Top <br />Diameter <br />in <br />Bottom <br />Diameter <br />in <br />Wall <br />Thickness <br />in <br />Bend <br />Radius <br />in <br />Pole Grade <br />L1 59.00-19.92 39.08 4.08 12 16.5620 24.3820 0.2812 1.1250 A572-65 <br />(65 ksi) <br />L2 19.92-0.00 24.00 12 23.0025 27.8000 0.3438 1.3750 A572-65 <br />(65 ksi) <br /> <br /> <br />