Laserfiche WebLink
CITY OF SANTA ANA <br />Planning and Building Agency <br />NOTES: <br />1. GENERAL CONTRACTOR IS TO FIELD VERIFY ALL EXISTING ANTENNA RAD CENTERS, ANTENNA TIP HEIGHTS WITH A PRE -TAPE DROP, AND AZIMUTHS PRIOR <br />TO CONSTRUCTION. ALL CHANGES TO THE ANTENNA POSITIONS, AZIMUTHS, AND RAD CENTERS NEED TO BE DISCUSSED WITH RF AND AT&T FIELD <br />CONSTRUCTION MANAGER. ALL CHANGES SHALL BE NOTED ON CONSTRUCTION AS BUILTS. <br />2. TOWER AND TOWER FOUNDATION DESIGN HAS BEEN PREPARED AND PROVIDED BY OTHERS. REFER TO MANUFACTURER'S APPROVED TOWER DRAWINGS OR <br />CURRENT STRUCTURAL ANALYSIS. THE RF RAD CENTER OF THE PROPOSED ANTENNAS AND MOUNTING PLATFORM ARE BASED ON INFORMATION PROVIDED <br />THROUGH AT&T. <br />3. THIS DRAWING IS A GRAPHICAL REPRESENTATION OF THE TOWER, THE RF RAD CENTER OF THE PROPOSED ANTENNAS AND PROPOSED MOUNTING <br />PLATFORM/SECTOR FRAME BASED ON INFORMATION PROVIDED THROUGH AT&T, AND /OR ANALYZED BY OTHERS. BC ARCHITECTS ENGINEERS CERTIFIES <br />ONLY THAT INFORMATION PROVIDED TO BC ARCHITECTS ENGINEERS FOR THE PREPARATION OF THESE PLANS AND IS NOT CERTIFYING NOR WARRANTING <br />THE DESIGN NOR VERIFYING THE ANALYTICAL RESULTS OF THE STRUCTURAL ANALYSIS PERFORMED BY OTHERS <br />4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF THE PROPOSED CABLES, CABLE LADDER, AND/OR OTHER CABLE SUPPORTING SYSTEM PER CURRENT <br />STRUCTURAL ANALYSIS. <br />5. ALL COAX CABLES SHALL BE STACKED IN ACCORDANCE WITH THE CURRENT STRUCTURAL ANALYSIS. THE CONTRACTOR OR SUBCONTRACTOR SHALL <br />FURNISH AND INSTALL CABLE LADDER RACK, CABLE TRAYS, ETC., AND/OR CONDUIT AS REQUIRED TO SUPPORT CABLES <br />0 <br />m 6. THE CONTRACTOR SHALL VERIFY WITH CONSTRUCTION TURF VENDORS 48 HOURS PRIOR TO INSTALLATION OF ALL EQUIPMENT/RF CONFIGURATION AND <br />o <br />ANY RELATED WORK RELATED TO THE COMPLETION OF THIS PROJECT. <br />w <br />CL <br />} 7. THIS DRAWING IS FOR GENERAL INFORMATION ONLY <br />U <br />tinn <br />lJ <br />U <br />w <br />w <br />4: <br />U <br />0 <br />i3 <br />g <br />w <br />U <br />2 <br />3 <br />Uj <br />w <br />0 <br />w <br />0 <br />tN <br />0 <br />0 <br />w <br />0 <br />D <br />Z <br />a <br />Uj <br />m <br />a <br />o <br />a <br />z <br />Z <br />w <br />U <br />0 <br />0 <br />Z <br />0 <br />U <br />Z <br />0 <br />U <br />U- <br />0 <br />11i RELOCATE (E) AT&T RRU: <br />V) (TYP. 1 PER SECTOR, 3 <br />U) <br />X <br />0 <br />w <br />Z <br />a <br />0 SCALE IN FEET <br />U <br />o r.r: <br />12" 0 2'-0" 4'-0" 6'-0" <br />0 <br />Z <br />I EXISTING ANTENNA PLAN <br />RELOCATE (E) AT&T DUAL RRU MOUNT <br />(TYP. 1 PER SECTOR, 3 TOTAL) <br />E) PIPE MAST <br />ER SECTOR, 3 TOTAL) <br />(E) AT&T INTEGRATED ANTENNA <br />(TYP. 1 PER SECTOR, 3 TOTAL) <br />4N <br />TRUE NORTH <br />SCALE:1/4"=1' (11x17) <br />SCALE:1/2"=1' (24x36) <br />TOWER SCOPE OF WORK: <br />1. REPLACE (3) MAST PIPE W/ 2-7/8' ON POS A3,B3,C2 <br />2. INSTALL (3) AIR6419 B77G STACKED ABOVE THE (E) AIR6449 B77D ON POS A3,B3,C2 <br />3. INSTALL (1) 606AWG DC TRUNK IN (N) 2' INNERDUCT TO THE (E) DC9 <br />INSTALL (N) AT&T PIPE TO PIPE <br />MOUNT (PART# SITEPR01) <br />DCP18K/DCP12K (TYP. 2 PER GAM <br />1 <br />SCALE IN FEET <br />12" 0 2'-0" 4'-0" 6'-0" <br />PROPOSED ANTENNA PLAN <br />1 <br />NOTE <br />GROUND ALL (N) EQUIPMENT TO GROUND BARS. WITH THE APPROPRIATE <br />GROUND WIRE SIZES AND TYPES DETERMINED BY MFG & AT&T SPECIFICATIONS <br />1 <br />I NSTALL (N) 2-7/8' O.D X 10' PIPE MAST <br />(TYP. 1 PER SECTOR, 3 TOTAL) <br />SECTOR ALp <br />AZ=100. <br />i <br />INSTALL (N) AT&T AIR 6419 B77G STACKED ABOVE <br />ON (E) AIR6449 B77D INTEGRATED ANTENNA <br />(TYP. OF 1 PER SECTOR, 3 TOTAL) <br />-INSTALL (N) AT&T P2 STD X 10'-0' PIPE MAST <br />USING CROSSOVER PLATE SITEPRO PART# SCX7-K <br />TRUE NORTH <br />SCALE:1/4"=1' (1107) <br />SCALE:1/2"=1' (24x36) 2 <br />Approved <br />AT&T <br />to <br />1452 EDINGER AVENUE, 3RD FLOOR <br />TUS1N, CA 92780 <br />amentuml <br />2 ASH STREET, ST 13000 <br />CONSHOHOCKEN, PA 19428 <br />a r c h it e c t s <br />e n g i n e e r s <br />5661 COLUMBIA PIKE, SUITE 200 <br />FALLS CHURCH, VA 22041-2868 <br />TEL (703) 671-6000 <br />FAX: (703) 671-6300 <br />REVISIONS <br />NOTE <br />GROUND ALL (N) EQUIPMENT TO GROUND BARS. WITH THE APPROPRIATE <br />GROUND WIRE SIZES AND TYPES DETERMINED BY MFG & AT&T SPECIFICATIONS <br />1 <br />I NSTALL (N) 2-7/8' O.D X 10' PIPE MAST <br />(TYP. 1 PER SECTOR, 3 TOTAL) <br />SECTOR ALp <br />AZ=100. <br />i <br />INSTALL (N) AT&T AIR 6419 B77G STACKED ABOVE <br />ON (E) AIR6449 B77D INTEGRATED ANTENNA <br />(TYP. OF 1 PER SECTOR, 3 TOTAL) <br />-INSTALL (N) AT&T P2 STD X 10'-0' PIPE MAST <br />USING CROSSOVER PLATE SITEPRO PART# SCX7-K <br />TRUE NORTH <br />SCALE:1/4"=1' (1107) <br />SCALE:1/2"=1' (24x36) 2 <br />Approved <br />AT&T <br />to <br />1452 EDINGER AVENUE, 3RD FLOOR <br />TUS1N, CA 92780 <br />amentuml <br />2 ASH STREET, ST 13000 <br />CONSHOHOCKEN, PA 19428 <br />a r c h it e c t s <br />e n g i n e e r s <br />5661 COLUMBIA PIKE, SUITE 200 <br />FALLS CHURCH, VA 22041-2868 <br />TEL (703) 671-6000 <br />FAX: (703) 671-6300 <br />REVISIONS <br />REV. <br />DATE <br />DESCRIFMON <br />INRULLS <br />A <br />01-23-25 <br />ISSUED FOR REVIEW <br />CG <br />B <br />04-22-25 <br />ISSUED FOR REVIEW <br />SD <br />0 <br />09-19-25 <br />FINAL CD'S <br />SD <br />i <br />I <br />NOT FOR CONSTRUCTION UNLESS <br />LABELED AS FOR CONSTRUCTION 10 <br />QRcj EI SO* <br />Q � � <br />* C 90957 <br />s� 919.2-S �Q <br />9 CIV1\- Q� <br />LICENSE NUMBER: C90957 <br />EXPIRATION DATE: MARCH 31, 2026 <br />SICA001904 <br />10087182 <br />2731 NORTH GRAND <br />SANTA ANA, CA 92705 <br />SHEET TITLE <br />EXISTING & <br />PROPOSED <br />ANTENNA PLAN <br />SHEET NUMBER <br />A-3 <br />E <br />