My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2223 S Rene Dr - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Rene Dr
>
2223 S Rene Dr
>
2223 S Rene Dr - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 5:00:19 AM
Creation date
5/19/2026 5:00:09 AM
Metadata
Fields
Template:
Plan
Permit Number
101124136
101126817
Full Address
2223 S Rene Dr
Street Number
2223
Street Direction
S
Street Name
Rene
Street Suffix
Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(E) Garage door to be removed <br />(E <br />) <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br /> <br />T <br />O <br /> <br />BE <br /> <br />R <br />E <br />M <br />O <br />V <br />E <br />D <br />(E <br />) <br /> <br />D <br />O <br />O <br />R <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />RE <br />M <br />O <br />V <br />E <br />D <br />(E) Wall to be demo <br />(E) Wall to be demo <br />(E <br />) <br /> <br />W <br />a <br />l <br />l <br /> <br />t <br />o <br /> <br />b <br />e <br /> <br />d <br />e <br />m <br />o <br />(E <br />) <br /> <br />W <br />a <br />l <br />l <br /> <br />t <br />o <br /> <br />b <br />e <br /> <br />d <br />e <br />m <br />o <br />8' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />10 <br />' <br /> <br />- <br /> <br />9 <br />" <br />11' - 6" <br />3' - 0" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />5' - 6" <br />5 <br />AD.4 <br />130 CFM range hood vented <br />directly to the outside <br />exhaousting.(N) KITCHEN <br />(N) BATHROOM <br />FAN <br />(N) BATHROOMFAN <br />(N) W&D <br />A <br />B <br />C <br />A <br />FAN <br />(N) BEDROOM <br />SD <br />(N) BEDROOM <br />SD <br />(N) LIVING ROOM <br />15''15'' <br />24 <br />' <br />' <br />15''15'' <br />24 <br />' <br />' <br />(N) CLOSET <br />(N) CLOSET <br />5' <br /> <br />- <br /> <br />0 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />14 <br />' <br /> <br />- <br /> <br />3 <br />" <br />4' - 0"3' - 0"3' - 0"5' - 6"4' - 0"3' - 11" <br />13' - 6" <br />10' - 6"3' - 0" <br />3' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />8' - 0" <br />3' - 6" <br />5' <br /> <br />- <br /> <br />6 <br />" <br />SD CM <br />2' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0" <br />1 <br />22 <br />2 2 <br />3 <br />(N) 22''X30'' <br />ATTIC ACCESS <br />A-A <br />AD.4 <br />A-A <br />AD.4 <br />(N) ELECTRIC METER 100 AMP <br />(N) GAS <br />METER <br />(N) WATER HEATER-WH ENCLOSURE <br />MUST MATCH <br />WITH EXISTING <br />SIDING <br />DRAWING LEGEND <br />NEW WALLS <br />SMOKE DETECTORS <br />CARBON MOXIDE <br />DETECTORS <br />- ENERGY STAR EXHAUST FAN <br />NOTE: <br />-BATHROOM EXHAUST FANS <br /> SHALL BE ENERGY STAR <br /> COMPLIANT AND CONTROLLED <br /> BY HUMIDISTAT 4.506.1 TO BE <br /> TERMINATED OUTSIDE OF THE <br /> BUILDING <br /> MIN 50 CFM FOR FANS <br />CM <br />SD <br />FAN <br />Walls are 6' foot thick with 2''X 6''STUDS every 4'' Provide a <br />min. 26-gage weep screed for stucco at the foundation plate <br />line a minimum of 4-in. above the earth or 2-in above paved <br />areas. <br />NOTE: <br />SMOKE DETECTORS shall be interconnected hard-wired with <br />battery backup and shall be installed in accordance with NFPA <br />72. <br />EXISTING WALLS <br />DEMO WALLS <br />V A THERMOSTATIC PRESSURE <br />BALANCED VALVE (CPC 408.3) <br />21 <br />' <br /> <br />- <br /> <br />3 <br />" <br />(N) PORCH <br />2' <br /> <br />- <br /> <br />9 <br />" <br />6' - 0" <br />3' <br /> <br />- <br /> <br />6 <br />" <br />(N)THRESHOLD <br />1.25'' <br />ELECTRICAL STOVE <br />ø 36"ø 36" <br />1-HR FIRE RATEDWALL <br />5' <br /> <br />- <br /> <br />8 <br />" <br />21 <br />' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0"19' - 0" <br />(N) HEAT PUMP <br />46 CFM PER <br />ENERGY CALCS <br />46 CFM PER <br />ENERGY CALCS <br />46 CFM PER <br />ENERGY CALCS <br />(N) 1 HOUR FIRE RATED WALL <br />11' - 0" <br />11 <br />' <br /> <br />- <br /> <br />3 <br />" <br />11' - 0" <br />8' <br /> <br />- <br /> <br />2 <br />" <br />11 <br />' <br /> <br />- <br /> <br />3 <br />" <br />19 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />7' - 6" <br />16' - 0" <br />38' - 0" <br />2' <br /> <br />- <br /> <br />8 <br />" <br />4' <br /> <br />- <br /> <br />3 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />8' <br /> <br />- <br /> <br />4 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />4' - 0"4' - 0"6' - 7" <br />38' - 0" <br />0' - 4"0' - 4" <br />C <br />A <br />1' <br /> <br />- <br /> <br />0 <br />" <br />2' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />AD <br />U <br /> <br />W <br />A <br />L <br />L <br />S <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />I <br />O <br />N <br />AD <br />U <br /> <br />W <br />A <br />L <br />L <br />S <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />I <br />O <br />N <br />ADU WALLS PROJECTION <br />ADU WALLS PROJECTION <br />EXISTING PATIO COVER <br />SL <br />O <br />P <br />E <br /> <br />3 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />SL <br />O <br />P <br />E <br /> <br />3 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />SL <br />O <br />P <br />E <br /> <br />3 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />SL <br />O <br />P <br />E <br /> <br />3 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />SL <br />O <br />P <br />E <br /> <br />3 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />SL <br />O <br />P <br />E <br /> <br />3 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />A-A <br />AD.4 <br />A-A <br />AD.4 <br />(E) SLOPE 2" / 12"(E) SLOPE 2" / 12" <br />DATE: <br />SCALE: <br />Adan MoralesDRAFTER: <br />PERMIT No <br />SH <br />E <br />E <br />T <br /> <br />T <br />I <br />L <br />E <br />: <br />DESIGN - PLANNING - PERMIT <br />7469 Foothill Blvd, Tujunga, <br />CA 91042 <br />Cel: (323) 516-5846 <br />Email: info@arkitpp.com <br />info@arkitpp.com <br />Office Hours <br />Monday - Friday: 8:00am to 6:00 pm <br />THIS DESIGN AND <br />DRAWINGS, ARE COPYRIGHT <br />PROTECTED AND ARE THE <br />EXCLUSIVE PROPERTY OF <br />ARKIT PLANS & PERMIT, <br />THEY SHALL BE NO USED, <br />MODIFIED DUPLICATED IN <br />WHOLE OR IN ANY MANNER, <br />NOR ASSIGNED TO A THIRD <br />PARTY WITHOUT THE <br />WRITTEN AUTHORIZATION <br />OF ARKIT PLANS & PERMIT. <br />1 <br />REVISIONS <br />SYMB DESCRIPTIONS DATE <br />REVISION <br />OWNER: Gustavo Valencia / Yannet Leal <br />ADDRESS: 2223 S Rene Dr, <br />Santa Ana, CA 92704 <br />PROPOSED FOR: <br />PROJECT <br />MANAGEMENT:Rafael Estevez <br />AS SHOWN <br />N <br /> Approval stamp <br />FEB 5 2026 <br />NE <br />W <br /> <br />A <br />D <br />U <br /> <br />7 <br />9 <br />8 <br /> <br />S <br />Q <br />. <br />F <br />T <br />. <br />AD.3 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />A <br />N <br />D <br /> <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />F <br />L <br />O <br />O <br />R <br />PL <br />A <br />N <br /> <br />& <br /> <br />R <br />O <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br />WINDOW SCHEDULE <br />NO.SIZES <br />WIDTH HEIGHT TYPE MATERIAL QUANTITY REMARKS SHDC U-FACTOR <br />A 4'-0''4'-0''VINYL 4 TEMPERED <br />GLAZED <br />SLIDINGB3'-0''3'-0''VINYL 1 TEMPERED <br />GLAZED <br />DOOR SCHEDULE <br />NO.SIZES <br />WIDTH HEIGHT TYPE MATERIAL QUANTITYNo. PANELS <br />1 4'-0''6'-8''SOLID <br />CORE <br />HINGE23'-0''6'-8''WOOD 4 <br />REMARKS <br />1- <br />HOLLOW <br />CORE <br />.23 NFRC .3 <br />.23 NFRC .3 <br />- <br />3 3'-6''6'-8''1- <br />SLIDINGC2'-0''2'-0''VINYL 2 TEMPERED <br />GLAZED .23 NFRC .3 <br />HINGE WOOD <br />WOOD <br />SLIDING <br />FOLDING HOLLOW <br />CORE <br /> 1/4" = 1'-0" <br />EXISTING FLOOR PLAN1 <br /> 1/4" = 1'-0" <br />PROPOSED FLOOR PLAN2 <br /> 1/4" = 1'-0" <br />ROOF PLAN3 <br />Carbon monoxide detectors are <br />required to be hard wired with battery <br />backup (CRC R315.6). <br />2. NOTE: <br /> ATTIC VENTILATION CALCS: <br /> ADU 798 SQ.FT DIVIDED BY 150 = 5.32 <br /> 5.32 x 144 = 766.08 <br /> 766.08 SQ. INCHES REQUIRED <br />VENTILATION: <br /> AREA (766.08) REQUIRED DIVIDED BY <br />242 (NET FREE AREA) SQ. INCHES = 3.16 <br /> 24" X 24" VENT = 242 NET FREE AREA <br />VENTS REQUIRED: 3.16 <br /> PROVIDE (3) 24" X 24" SCREENED <br />Louvered door with a <br />minimum of 100 sq.in. is <br />required for door 3 per <br />CMC 504.4.0 <br />3. NOTE: <br />Plans to comply with Energy Code 150.0(s)(t)(u)(v) <br />4- NOTE: <br />WALL REINFORCEMENT FOR GRAB BARS PER CRC R327.1.1A- DETAIL: <br />Note: <br />The suggested dimensions are to accommodate the minimum required 36-in clearance, center <br />to center, at a water closet; and minimum 24-in clear space in front of water closet. <br />B-DETAIL: ELECTRICAL RECEPTACLES, SWITCH AND DOORBELLS PER CRC R327 <br />Note: <br />Dedicated receptacle outlets; floor receptacle outlets; controls mounted on ceiling fans and <br />ceiling lights and controls located on appliances; and required receptacles on a wall space that <br />has a built-in feature above finish floor less than 15-in. <br />Annular spaces around <br />pipes, electrical cables, <br />conduits or other <br />openings in sole/bottom <br />plates at exterior walls <br />Shall be protected against <br />the passage of rodents by <br />closing such <br />openings with cement <br />mortar, concrete masonry <br />or similar methods. <br />1. NOTE: <br />150.0(s) Battery Ready: Mandates a 225-amp main panel, a 1-inch raceway <br />for future installation, space for a transfer switch, and four dedicated branch <br />circuits for essential loads. <br />150.0(t) Heat Pump Ready: Requires a dedicated 240V, 30-amp (or greater) <br />circuit within 3 feet of a gas furnace, with space in the panel. <br />150.0(u) Electric Cooktop Ready: Mandates a dedicated 240V, 50-amp <br />circuit near the gas cooktop. <br />150.0(v) Electric Dryer Ready: Mandates a dedicated 240V, 30-amp circuit <br />near the gas dryer. <br />1. RECEPTACLES OUTLETS SHALL BE TAMPER <br />RESISTANT. <br />2. LAUNDRY BRANCH CIRCUITS. AT LEST ONE 20- <br />AMP <br />BRANCH CIRCUITS SHALL BE PROVIDED TO <br />SUPPLY LAUNDRY RECEPTACLE OUTLETS. THIS <br />CIRCUIT SHALL HAVE NO OTHER OUTLETS. <br />3. A DEDICATED 20-AMP CIRCUITS SHALL BE <br />PROVIDED TO SERVE THE REQUIRED BATHROOM <br />OUTLETS. THIS CIRCUITS CANNOT SUPPLY ANY <br />OTHER OUTLETS (INCLUDING <br />BATHROOM LIGHTING AND FANS). <br />4. CLOTHES DRYER AND ELECTRICAL RANGER <br />SHALL HAVE AWIRE GROUNDED ELECTRICAL <br />OUTLET. <br />5. ALL RECESSED LIGHT FIXTURES SHALL BE IC <br />RATED OR FIXTURES NOT IDENTIFIED FOR <br />CONTACT WITH INSULATION SHALL HAVE ALL <br />RECESSED PARTS SPACED AL LEAST 12'' FROM <br />COMBUSTIBLE MATERIALS AND 3'' FROM THERMAL <br />INSULATION. <br />6. TWO SMALL- APPLIANCE BRANCH CIRCUITS FOR <br />THE <br />KITCHEN LIMITED TO SUPPLYING WALL AND <br />COUNTER <br />OUTLETS ONLY. ADDITIONAL CIRCUITS SHALL BE <br />PROVIDED TO SUPPLY OTHER APPLIANCES, SUCH <br />GARBAGE DISPOSAL, DISH WATER, AND OTHERS. <br />7. ALL 120 VOLT. SINGLE PHASE. 15 AND 20 -AMP <br />BRANCH CIRCUITS SUPPLYING OUTLETS <br />INSTALLED IN DWELLING UNIT FAMILY ROOMS, <br />DINING ROOMS, LIVING ROOMS, PARLORS, <br />LIBRARIES, DENS, BEDROOM, OR SIMILAR ROOMS <br />OR AREAS SHALL DE PROTECTED BY A LISTED <br />ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION- <br />TYPE, INSTALLED TO PROVIDED <br />PROTECTION OF BRANCH CIRCUIT. <br />ELECTRICAL NOTES
The URL can be used to link to this page
Your browser does not support the video tag.