Aryam Design & Build <br />Project <br />1513 McFadden <br />Job Ref. <br />25073 <br />Section <br />GLB beam check <br />Sheet no./rev. <br /> 1 <br />Calc. by Date Chk'd by Date App'd by Date <br />STRUCTURAL GLUED LAMINATED TIMBER (GLULAM) MEMBER ANALYSIS & DESIGN (NDS) <br />In accordance with the ANSI/AF&PA NDS-2018 using the ASD method <br />Tedds calculation version 1.7.10 <br />Unfactored Loads <br />0.0 <br />0.954 <br />Self weight included <br />Seismic Dead Roof Live <br />ft 56 <br />1A B <br /> <br />Bending Moment Envelope <br />0.0 <br />157.607 <br />kip_ft <br />ft 56 <br />1A B <br />130.7 <br />157.6157.6 156.9 <br />78.4 <br /> <br />Shear Force Envelope <br />0.0 <br />10.163 <br />-10.163 <br />kips <br />ft 56 <br />1A B <br />10.2 <br />-0.4 <br />-10.2 <br /> <br />Applied loading <br />Beam loads <br />Dead self weight of beam  1 <br />Cross member Dead point load 954 lb at 96.00 in <br />Cross member Roof Live point load 1600 lb at 96.00 in <br />Cross member Dead point load 954 lb at 192.00 in <br />Cross member Roof Live point load 1600 lb at 192.00 in <br />HVAC support beam Dead point load 954 lb at 288.00 in <br />HVAC support beam Roof Live point load 1600 lb at 288.00 in <br />HVAC support beam Seismic point load 759 lb at 288.00 in <br />HVAC support beam Dead point load 954 lb at 384.00 in <br />HVAC support beam Roof Live point load 1600 lb at 384.00 in <br />HVAC support beam Seismic point load 759 lb at 384.00 in