My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20173667 - Permit
PBA
>
Building
>
Permits
>
F
>
Fifth St
>
4280 W Fifth St
>
20173667 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2021 2:55:49 PM
Creation date
10/6/2021 12:00:29 PM
Metadata
Fields
Template:
Permit
Permit Number
20173667
Full Address
4280 W Fifth St
Permit ID
276562
Master ID Number
2021-167142
Project Name
Miscellaneous Counter1 Permit
Street Number
004280
Street Direction
W
Street Name
Fifth
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
6/29/2021
Issued Date
6/29/2021
Finalized Date
8/13/2021
Flood Zone
A-0602320256J
Description of Work
Installation of roof mounted solar. All fees paid on #101107081.
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT.PROCESS FOR SMALL-SCALE PV SYSTEMS <br />STANDARD STRING SYSTEM <br />The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations <br />are simple, needing only a basic review and when an installation is more complex. It is likely that 5O%-75% of all residential <br />systems will comply with these simple criteria. For projecm that Fail to meet the simple criteria, resolution steps have been <br />suggested to provide as a path to permit approval. <br />Required h{ormation Jor Permit: <br />1. Site plan showing location of major components on the property. This drawing need nor be exactly ro scale, but ir <br />should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings <br />with a 3'perimeter space at ridge and sides may not need separate nre service review <br />2. Electrical diagram showing PV array conflguration, wiring system. overcurrent protection. invertet disconnects, <br />required signs, and ac connection to building (see supplied sEndard electrical diagram). <br />5. Specincation sheets and installation manuals (if available) for all manufactured components including, but not <br />limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. <br />Step 1 : Structural Review o[ PV Array Mounting System <br />Is the aray to be mounted on a defined, permittrd roof structur€?Yes ENo <br />U No due to non-compliant roof or a ground mount, stbmit completed worksheet for the structure WKSI <br />Roof Infonnation: <br />1. Is the roofrng type lighMeight (Yes = composition, lightweight masonry, meral, erc...)YES <br />It weighs over 9lbs <br />If No, submit completed worksheet lor rool stn)cture WXSI fNo = heavy masonry, slate, etc. . .) <br />2. Does the roof have a single roof covering? Eyes ntlo <br />U No, submit completed worksheet fot roof stn)cture WNSI . <br />3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk)Caulk, Flashings <br />M ountifi g Sy s t ern Inf orm at ion : <br />1. Is the mounting structure an <br />benearh the module frames? <br />ineered product designed to mount PV modules with no more than an 18'' gape <br />Yes tr No <br />Mounting Sys rem Manufacturer UNIMC producr Name and p1s6.1g SOLARHOOK UNIV 004CT5S <br />Total Weigh t of PV Modules un6 nu1lt 1535.75 lbs <br />Total Number of Atnchment Points 79 <br />Weight per Attachment Point (b + c)19.43 bs (if greater than 45 lbs, see WKS I ) <br />Maximum Spacing Berween Atrachmen! Points on a Rail 72' inches (see producr manual for <br />maximum spacing allowed based on maximum design wind speed) <br />Total Surface Area of PV Modules (square feet)476 ft'? <br />Distributed Weighr of PV Module on Roof (b + l)3.22 lbs/[t'z <br />Il distributed w€ight oI the PV system is geater than 5 lbslft'z, see WRSI . <br />Step 2: Electrical Review of PV System (Calculations lor Electrical Diagram) <br />In order for a PV system to be considered for an expedited permit process, the following must apply: <br />l. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. <br />2. The PV array is composed of 4 series strings or less per inverter. <br />3. The total inverter capacity has a continuous ac power output 13,440 WatB or less <br />4. The ac interconnection point is on the load side of service disconnecting means (690.64(8)). <br />5. One ofthe standard electrical diagrams(81.1, E1.1a, El.1b, orEl.1c) can be used to accurately represent rhe PV <br />system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. <br />Fill out the standard. electrical diagram completely. A guide to the electical diagram is Wovided. to help the aryticant <br />understand each blank to ftt in. If the electrica[ system is more complex than the standard electrical diagram can elJectively <br />communicate, provide an alternative diagram with approprio.te detail. <br />2 ExpEDITED PERMIT PRocEss FoR PV SysrEMs <br />a. <br />b. <br />C, <br />d <br />f. <br />If No, provide detaib of structurdl attdchment cerdrted by a tlesign professional. <br />2. For manufacured mounting systems, hll out information on the mounting system below:
The URL can be used to link to this page
Your browser does not support the video tag.