Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />Site Address: <br />System AC Size <br />Site Name <br />srzE <br />Dale <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />I\.,IODULE MAKE HYUNDAI <br />NOTES FOR ALL DRAWINGS: <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODEOREFERENCES <br />sHowN As rrvEc )oo(.r9 <br />INVERTER RATINGS (Guids Section 4) <br />INVERTERMAKE SOLAREDGE <br />TNVERTERMoDEL SE6000H-USRGM <br />MAx Dc voLT RATTNG 6000 <br />MAxPowER@4o"c 6000 <br />NoMTNAL Ac VoLTAGE 2Og <br />MAx Ac CURRENT 25 <br />60 <br />SIGNS SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT <br />RATED MPP VOLTAGE <br />MAX SYSTEM VOLTAGE <br />MAX CIRCUIT CURRENT <br />MoDULE MooEL HiA-S31OHG <br />MAX POWER.POINT CURRENT (I P) <br />MAX POWER.POINT VOLTAGE {VMP) <br />oPEN-CTRCUTT VOLTAGE (Voc) <br />sHoRT-CTRCUTT CURRENT (rsc) <br />MAX SERTES FUSE (OCPD) <br />MAXIMUM POWER (PMAX) <br />MAX VOLTAGE (rYP 600VDc) <br />VOC TEMP COEFF (mV/"CE or o/"PCD) <br />IF COEFF SUPPLIED, CIRCLE UNIlS <br />9.51 A <br />32.58 v <br />39.58 v <br />9.95 A <br />20A <br />310 w <br />1500 v <br />-40C-+85C <br />WARNING: ELECTRICAL SHOCK <br />HAZARD_LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSIIION <br />SIGN FOR INVERTER OCPD AND <br />AC DTSCONNECT (rF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />NA <br />NA <br />NA <br />NA <br />Ac ourPUT oURRENT 25 <br />NOMINAL AC VOLTAGE <br />. MAX OCPD RATING <br />NOIES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendax D) <br />1 ) LOWEST EXPECT AMAIENT TEMPERATURE BASEO ON ASHRAE MINIMUM MEAN <br />EXTREME DRY AULB TEMPERATURE FOR ASHRAE I-OCATION MOST SIMILAR TO <br />INSTALLATION LOCATION, LOWEST EXPECTED AMBIENT TEMP OC <br />2 ) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION IIOST SIMILAR TO <br />INSTALLATION LOCATION, HIGHEST CONTINUOUS TEMPERATURE <br />2.) 2005 ASHRAE FUNDEMENTALS 2olo DESIGN TEMPERATURES DO NOT EXCEEO <br />47OC IN THE UNITED STATES (PALM SPRINGS, CA IS 44,1OC) FORLESSTHAN9 <br />CURRENT.CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5'ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47OC OR LESS (ALL OF UNITED STATES), <br />a) 12 AwG, 90'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH l6c OF 7 68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SI\TALLER <br />FUSE, <br />b) 1O AWG, gO'C CONOUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />wlTH lsc OF I 6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER <br />FUSE <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NOTES FQR INVERTER CIRCUITS (Guide Soction 8 and 9): <br />1) IF UTILITY REQUIRES A VISIBLE.BREAK SWITCH, OOES THIS SWITCH MEET THE <br />REQUIREMENT? YES O NOE] N/A tr <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES E] NO O N/A f] <br />3) SrZE PHOTOVOLTATC POWER SOURCE (OC) CONDUCTORS EASED ON MAX <br />CURRENT ON NEC 690,53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF , INVERTER OCPD(S), ONE FOR EACH INVERTER DOES TOTAL <br />SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION lN 6S0.44(8)(2Xa)? <br />YES E NOtr <br />NOTES FOR STANDARD STRING SYSTEM ELECTRICAL DIACRAM <br />F <br />a- <br />o <br />Uod.e- <br />F- <br />:d <br />I <br />Lo <br />a-x <br />NTS