Laserfiche WebLink
REVISIONS DATE <br />FR <br />A <br />M <br />I <br />N <br />G <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S <br /> <br />- <br /> <br />H <br />F <br />X <br /> <br />P <br />A <br />N <br />E <br />L <br />S <br />DATE: <br />® <br />NOTE: <br />ATTACHMENTS TO ADJACENT <br />TRIMMERS MAY BE MADE AT <br />PREPUNCHED SCREW HOLES OR <br />WITH SELF TAPPING SCREWS <br />(#12 AT EDGES, #10 AT FACE). <br />SECTION B <br />SECTION A <br />OPTIONAL INSTALLATION WITH <br />HARDY FRAME BASE <br />EXTENSION (HFBX) FOR <br />ADJACENT FRAMING <br />HFBX <br />#10 SELF-TAPPING SCREWS <br />AT FACE OF PANEL. <br />(BUGLE HEAD WITH SELF <br />DRILLING TIP SHOWN) <br /> #12 SELF-TAPPING SCREWS <br />AT EDGE OF PANEL. <br />(BUGLE HEAD WITH SELF <br />DRILLING WING TIP SHOWN) <br />BUGLE HEAD WAFER HEAD FLAT TRUSS MODIFIED TRUSS HEX HEAD <br />SELF DRILLING TIP SELF DRILLING WING TIP <br />#10 SELF-TAPPING SCREWS <br />AT FACE OF PANEL. <br />(HEX HEAD WITH SELF <br />DRILLING TIP SHOWN) <br />NOTES: <br />A.SURFACE FINISHES, CONNECTORS AND FIXTURES ARE ATTACHED TO THE PANEL <br />FACE WITH # 10 SELF-TAPPING SCREWS SPACED NO LESS THAN 2-1/4" OC. <br />B.ATTACHMENTS TO THE PANEL EDGES ARE MADE WITH # 12 SELF-TAPPING SCREWS. <br />C.STRUCTURAL CONNECTIONS ARE TO BE DESIGNED BY THE DESIGN PROFESSIONAL. <br />D.STRUCTURAL HARDWARE USED TO TRANSFER LOADS SHOULD NOT EXCEED 12 <br />GAUGE. <br /> 21" PANEL 24" PANEL 18" PANEL <br /> 9" PANEL 12" PANEL 15" PANEL <br />15" Width = 8 <br />6 <br />3-1/2 <br />HFX-15,18,21 & 24x14 164-1/4 <br />1-1/8 <br />HFX-15,18,21 & 24x15 <br />HFX-15,18,21 & 24x16 <br />HFX-15,18,21 & 24x17 <br />176-1/4 <br />188-1/4 <br />200-1/4 <br /> Top <br /> Screw Qty <br /> (ea) <br />18" Width = 10 <br />21" Width = 12 <br />24" Width = 14 <br /> 1 <br />Hold Down <br />Diameter <br /> (in) <br />HFX-15,18,21 & 24x18 <br />HFX-15,18,21 & 24x19 <br />HFX-15,18,21 & 24x20 <br />212-1/4 <br />224-1/4 <br />236-1/4 <br />Screw Qty <br />Available at <br />Edges (ea) <br />7 <br />8 <br />4 <br />3-1/2 <br />92-1/4 <br />1-1/8 <br />HFX-12,15,18,21 & 24x9 <br />HFX-12,15,18,21 & 24x10 <br />HFX-15,18,21 & 24x11 <br />104-1/4 <br />116-1/4 <br />128-1/4 <br /> Model <br />Number <br /> Net <br /> Height <br /> (in) <br /> Depth <br /> (in) <br /> 1 <br />Hold Down <br />Diameter <br /> (in) <br />HFX-15,18,21 & 24x12 <br />HFX-15,18,21 & 24x13 <br />140-1/4 <br />152-1/4 <br />Screw Qty <br />Available at <br />Edges (ea) <br />5 <br />6 <br />HFX-12,15,18,21 & 24x78 78 <br />HFX-9x79.5 79-1/2 <br /> Top <br /> Screw Qty <br /> (ea) <br /> Model <br />Number <br /> Net <br /> Height <br /> (in) <br /> Depth <br /> (in) <br /> 2 <br />3 <br /> 2 <br />3 <br />PANCAKE FIXTURE <br />AS NEEDED <br />INSTALLATION INSTRUCTIONS <br />1.WHEN INSTALLING ON CONCRETE CONNECT WITH (1 EA) HARDENED ROUND <br />WASHER BELOW (1 EA) GRADE 8 NUT, SECURE WITH A DEEP SOCKET <br />(RECOMMENDED) UNTIL SNUG TIGHT. ALTERNATE WASHERS AND NUTS <br />ARE PROVIDED IN TABLE NOTE 1. <br />2.INSTALLATION ON CONCRETE PROVIDES THE HIGHEST ALLOWABLE <br />VALUES. CONFIRM WITH THE DESIGN PROFESSIONAL BEFORE INSTALLING <br />ON OTHER SUPPORTING SURFACES. <br />3.USE 1/4"X4-1/2" MITEK PRO SERIES WS SCREWS AT TOP CONNECTIONS <br />WITH A 2x FILLER. IF THE TOP OF PANEL IS IN DIRECT CONTACT WITH THE <br />COLLECTOR ABOVE (TOP PLATES, HEADER, BEAM, ETC.) USE1/4 x 3" <br />(MINIMUM) <br />4.FOR INSTALLATIONS WITH A FILLER GREATER THAN 1-1/2" ABOVE, OR WHEN <br />SPECIFIED BY THE DESIGN PROFESSIONAL, ADJACENT KING POSTS TO <br />BRACE THE OUT-OF-PLANE HINGE CAN BE CONNECTED WITH 1/4" DIA. <br />SCREWS THROUGH PRE-PUNCHED HOLES AT THE PANEL EDGES. <br />1.HOLD DOWN ANCHOR BOLTS CONNECT TO THE PANEL BASE WITH <br />HARDENED ROUND WASHERS BELOW GRADE 8 NUTS. ALTERNATE <br />WASHERS ARE (2 EA) ROUND-FLAT OR (2 EA) SAE WASHERS ON EACH <br />BOLT. ALTERNATE NUTS ARE 2H HEAVY HEX. <br />2.1/4" DIAMETER MITEK PRO SERIES WS SCREWS. LENGTH IS 3" (MINIMUM) <br />WHEN ATTACHED DIRECTLY TO THE COLLECTOR AND 4-1/2" (MINIMUM) <br />WHEN INSTALLING A 2x FILLER ABOVE THE PANEL. <br />3.ADJACENT FRAMING WITH 1/4" DIAMETER SCREWS IS REQUIRED AT THE <br />PANEL EDGES WHEN INSTALLING A FILLER ABOVE THE TOP CHANNEL <br />THAT IS GREATER THAN 1-1/2" OR WHEN SPECIFIED BY THE DESIGN <br />PROFESSIONAL. <br />HFX-9x8 93-3/4 <br />1.(A) PRE-WELDED STRAPS ARE PROVIDED ON 78" AND 79-1/2" PANEL HEIGHTS. <br />THEY ARE AVAILABLE FOR OTHER HEIGHTS UPON REQUEST. <br />(B) FIELD INSTALLED STRAPS WITH SELF TAPPING SCREWS ARE PERMITTED. <br />THE DESIGN AND CONNECTION IS BY THE DESIGN PROFESSIONAL. <br />2.A 2x WOOD FILLER WITH 1/4"x4-1/2" (MIN.) WS SCREWS IS PERMITTED. <br />3.WHEN CRIPPLE STUDS OCCUR, SHEAR TRANSFER DESIGN TO BE PER THE <br />BUILDING DESIGN PROFESSIONAL. <br />4.A 1" DIA. HOLE MAY BE ADDED IN THE PANEL FACE WHEN IT IS LOCATED IN <br />THE UPPER HALF OF THE PANEL HEIGHT AND IS 4" MINIMUM FROM ANY <br />EDGE. FOR PANELS MORE THAN 12" WIDE, ADDITIONAL HOLES MUST BE <br />OFFSET 1" MINIMUM FROM THE 3" DIA. PREPUNCHED HOLE. FOR HOLES <br />LARGER THAN 1" DIAMETER OR TO ADD MORE THAN ONE HOLE CONTACT <br />MITEK HARDY FRAME TECHNICAL SUPPORT AT (800) 754-3030. <br />1 <br />1. 15# FELT OR EQUIVALENT MOISTURE BARRIER RECOMMENDED BETWEEN <br /> PANEL BASE AND CONCRETE. <br />2. NUTS AND WASHERS PER TABLE NOTE 1. <br />3. ADJACENT FRAMING OPTIONAL U.N.O. BY BUILDING DESIGN PROFESSIONAL. <br />3 <br />2 <br />1.TRIMMERS PROVIDE FULL BEARING FOR HEADER ABOVE, DESIGN AND <br />CONNECTIONS BY BUILDING DESIGN PROFESSIONAL. <br />2.6x HEADER. <br />3.WOOD MEMBERS FOR BACKING MAY BE INSERTED VERTICALLY OR HORIZONTALLY <br />IN THE PANEL CAVITY AS NEEDED. <br />4.WOOD MEMBER FLUSH TO FACE OF WALL FOR BACKING AS NEEDED. <br />1 <br />1 <br />2 <br />4 <br />3 <br />1 <br />1.PLUS OR MINUS 1-1/2" GAP TO BE FILLED WITH 5,000 PSI NON-SHRINK <br />GROUT (MINIMUM). <br />2.NUT AND WASHER GRADES PER TABLE NOTE 1. <br />1.15# FELT OR EQUIVALENT MOISTURE BARRIER RECOMMENDED BETWEEN <br /> PANEL BASE AND CONCRETE. <br />2.NUTS AND WASHERS PER TABLE NOTE 1. <br />1 <br />2 <br />2 <br />1.15# FELT OR EQUIVALENT MOISTURE BARRIER RECOMMENDED <br />BETWEEN PANEL BASE AND TREATED PLATE. <br />2.NUTS AND WASHERS PER TABLE NOTE 1. <br />2 <br />1 <br />1.15# FELT OR EQUIVALENT MOISTURE BARRIER RECOMMENDED BETWEEN <br />PANEL BASE AND CONCRETE. <br />2.NUTS AND WASHERS PER TABLE NOTE 1. <br />3.ADJACENT FRAMING WITH 1/4" DIAMETER SCREWS INSTALLED AT THE <br />PANEL EDGES WHEN INSTALLING A FILLER GREATER THAN 1-1/2" ABOVE OR <br />WHEN SPECIFIED BY DESIGN PROFESSIONAL. <br />2 <br />1 <br />3 <br />1.WOOD FILLER WITH USP MP4F CONNECTORS BOTH SIDES, QUANTITY BY <br />BUILDING DESIGN PROFESSIONAL. <br />2.1/4" x 3" (MINIMUM) WS SCREWS, QUANTITY PER TABLES <br />3.ADJACENT FRAMING WITH 1/4" DIAMETER SCREWS INSTALLED THROUGH <br />PRE-PUNCHED HOLES IN PANEL EDGES REQUIRED WHEN INSTALLING A <br />FILLER GREATER THAN 1-1/2" ABOVE TO BRACE OUT-OF-PLANE HINGE OR <br />WHEN SPECIFIED BY THE DESIGN PROFESSIONAL. <br />4.PRE-DRILL 3/16" DIA. HOLES, EVENLY SPACED IN FACE OF PANEL NO LESS <br />THAN 2-1/4" OC AND INSTALL 1/4" DIA. WOOD SCREWS INTO 2x (MIN.) WOOD <br />"LEDGER" IN PANEL CAVITY. <br />5.CONNECTOR AND ATTACHMENT BY BUILDING DESIGN PROFESSIONAL. <br />4 5 <br />3 <br />1 <br />2 <br />1.CAVITY ORIENTED FOR CONNECTION ACCESS. <br />2.NUTS AND WASHERS PER TABLE NOTE 1. <br />3.NOMINAL 8 INCH FRAMING ABOVE (MIN). <br />4.A 2x FILLER WITH 1/4" x 4-1/2" MINIMUM <br /> WS SCREWS IS PERMITTED. <br />5.FIELD INSTALLED WOOD BACKING AS NEEDED. <br />SECTION A <br />5 <br />1 <br />4 3 <br />2 <br /> 9" Width = 5 <br />12" Width = 6 <br />15" Width = 8 <br />18" Width = 10 <br />21" Width = 12 <br />24" Width = 14 <br />31 <br />1.1/4" x 3" (MINIMUM) WS SCREWS, QUANTITY PER TABLES <br />2.1/4" x 4-1/2" (MINIMUM) WS SCREWS, QUANTITY PER TABLES <br />3.2x WOOD FILLER. <br />2 <br />HFX-12,15,18,21 & 24x8 <br />HFX2 <br />1-1-2018 <br />® <br />TM <br />TM <br />® <br /> ALLOWABLE VALUES ON 2x PLATE ARE LESS THAN INSTALLATION ON CONCRETE ALLOWABLE VALUES ON N&W ARE LESS THAN INSTALLATION ON CONCRETE <br />NOTE: <br />TO PREVENT DRILLING ADDITIONAL HOLES ORIENT THE PANEL CAVITY <br />TOWARD THE FIXTURE BEING INSTALLED. <br />TRIMMERS PER <br />DESIGN PROFESSIONAL <br />OPTIONAL <br />SOFFIT <br />3 <br />1B <br />2 <br />1A <br />4FILLER GREATER THAN 1-1/2 IN.6 <br />3BACK TO BACK INSTALLATION <br />8 <br />11 <br />2 <br />5 <br />7 <br />10 <br />1 <br />4 <br />9 <br />A <br />B <br />C <br />D <br />RAISED FLOOR HEAD-OUT <br />INSTALLATION ON 2x PLATE <br />STEEL BEAM ABOVE THRU-BOLT <br />TOP PLATE CONNECTIONS <br />INSTALLATION ON CONCRETE <br />INSTALLATION ON NUTS & WASHERS <br />6x HEADER ABOVE-SECTIONS <br />TOP CONNECTION TO HEADER <br />INSTALLATION ON CURB <br />HFX PANELS 78 IN. THROUGH NOMINAL 13 FEET <br />BALLOON PANELS 14 FEET THROUGH 20 FEET <br />5a 5b <br />B <br />A <br />® <br />3 <br />4 <br />1.STEEL BEAM PER PLANS <br />2.ALL THREAD RODS THRU-BOLTED TO STEEL BEAM BY BUILDING <br />DESIGN PROFESSIONAL. <br />3.NUTS AND WASHERS PER TABLE NOTE 1. <br />4. HARDY FRAME STACKING WASHERS (HFSW( REQUIRED TO BE <br />WELDED INSIDE TOP CHANNEL OF LOWER PANEL. <br />5. HARDY FRAME "STK" PANEL WITH STACKING WASHERS WELDED <br />INSIDE THE TOP CHANNEL BY MANUFACTURER. <br />1 <br />2 <br />5 <br />® <br />® <br /> RAKE WALL INSTALLATION