Laserfiche WebLink
CONCRETE NOTES <br />1.ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 <br />DAYS SHALL BE MIN 2500 PSI, U.N.O. <br />2.CONCRETE IS REINFORCED AND CAST-IN-PLACE UNLESS OTHERWISE NOTED. WHERE <br />REINFORCING IS NOT SPECIFICALLY SHOWN OR WHERE DETAILS ARE NOT GIVEN, PROVIDE <br />REINFORCING SIMILAR TO THAT SHOWN FOR SIMILAR CONDITIONS, SUBJECT TO REVIEW BY <br />THE OWNER'S REPRESENTATIVE. <br />3.ALL PHASES OF WORK PERTAINING TO THE CONCRETE CONSTRUCTION SHALL CONFORM <br />TO THE LATEST EDITION OF ACI318 "BUILDING CODE REQUIREMENTS FOR REINFORCED <br />CONCRETE", AND THE LATEST EDITION OF ACI117 "SPECIFICATIONS FOR TOLERANCES FOR <br />CONCRETE CONSTRUCTION AND MATERIALS". <br />4.NO MORE THAN ONE GRADE OF CONCRETE SHALL BE ON THE JOB SITE AT ANY ONE TIME. <br />5.CONCRETE MIXES SHALL BE PREPARED WITH TYPE II/V PORTLAND CEMENT CONFORMING <br />TO ASTM C150. <br />6.CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT <br />VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY REPLACE UP TO <br />20% PORLAND CEMENT BY VOLUME. <br />7.CONCRETE MIX PROPORTIONING SHALL MEET STATISTICAL STRENGTH REQUIREMENTS OF <br />ACI 301 AND ACI 214R. MIX DESIGNS SHOWING COMPLIANCE WITH STRENGTH <br />REQUIREMENTS TO BE SUBMITTED TO E.O.R FOR REVIEW. <br />8.NORMAL WEIGHT CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33. LIGHT WEIGHT <br />CONCRETE AGGREGATES SHALL CONFORM TO ASTM C330. <br />9.CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND SHALL <br />BE SUBMITTED TO E.O.R. <br />10.WATER USED IN MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. <br />11.THOROUGHLY CLEAN AND ROUGHEN ALL HARDENED CONCRETE AND MASONRY SURFACES <br />TO RECEIVE NEW CONCRETE. INTERFACE SHALL BE ROUGHENED TO A FULL AMPLITUDE OF <br />1/4", U.O.N. <br />WOOD SPECIFICATIONS & NOTES <br />1.SAWN FRAMING LUMBER - DOUGLAS FIR-LARCH U.N.O: <br />a.BEAMS/ POST/ RAFTERS & ALL OTHER STRUCTURAL FRAMING: <br />·2x, 4x MEMBERS: NO. 2 <br />·6x, 8x MEMBERS: NO. 1 <br />b.STUDS: USE STUD GRADE IF HEIGHT UP TO 9'-0" AND NO. 2 IF TALLER THAN 9'-0". <br />c.PLATES AND BLOCKING: NO. 2 <br />d.ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE PRESERVATIVE <br />TREATED. <br />e.ALL FRAMING LUMBER SHALL HAVE 19% MAXIMUM MOISTURE CONTENT AT TIME OF <br />INSTALLATION AND FABRICATION. <br />2.ENGINEERED LUMBER: <br />ALL VERSA-LAM LAMINATED VENEER LUMBER MEMBERS (LVL) SHALL BE FABRICATED AND <br />ERECTED IN ACCORDANCE WITH ICC ES ESR-1040: <br />a.BEAM/HEADERS WITH 1 3/4" WIDE:Fb = 2800 psi, Fv = 285 psi, E = 2.0E6 psi <br />b.BEAM/HEADERS WITH 3 1/2" AND WIDER:Fb = 3100 psi, Fv = 285 psi, E = 2.0E6 psi <br />c.RIMBOARD:Fb = 1750 psi, Fv = 225 psi, E = 1.3E6 psi <br />3.DIAPHRAGM (U.N.O. ON PLAN): <br />a.ROOF SHEATHING: INSTALL 15/32" THICK APA-RATED EXP 1 PANELS WITH A MINIMUM SPAN <br />RATING OF 32/16. FASTEN USING 8D COMMON NAILS SPACED AT 6" O.C. AT PANEL EDGES AND <br />BEARING SUPPORTS, AND 12" O.C. AT INTERMEDIATE FRAMING. <br />b.FLOOR SHEATHING: INSTALL 23/32" APA-RATED STURD-I-FLOOR TONGUE-AND-GROOVE EXP 1 <br />PANELS WITH A MINIMUM SPAN RATING OF 24" O.C. SECURE WITH 10D COMMON NAILS SPACED <br />AT 6" O.C. AT PANEL EDGES AND BEARING SUPPORTS, AND 12" O.C. AT INTERMEDIATE FRAMING. <br />c.INSTALLATION AND USAGE REQUIREMENTS SHALL COMPLY WITH NER-108. <br />d.ALL STRUCTURAL GRADE PANELS SHALL BE IDENTIFIED WITH A CERTIFICATION MARK FROM AN <br />APPROVED AGENCY: APA, PFS/TECO, OR PITTSBURG. <br />e.ADHESIVES USED FOR SECURING FLOOR SHEATHING TO FRAMING MEMBERS SHALL MEET APA <br />SPECIFICATION AFG-01. <br />f.ROOF DIAPHRAGM NAILING MUST BE VERIFIED PRIOR TO CONCEALMENT. PLYWOOD FACE GRAIN <br />SHALL BE INSTALLED PERPENDICULAR TO SUPPORTS. FLOORS SHALL UTILIZE <br />TONGUE-AND-GROOVE PANELS OR BLOCKED EDGES. PANEL SPANS SHALL BE IN ACCORDANCE <br />WITH TABLE 2304.8(1). <br />4.STRUCTURAL GLUED LAMINATED MEMBERS: <br />a.ALL STRUCTURAL GLUED LAMINATED MEMBERS SHALL BE COMBINATION 24F-V4 DF/DF <br />(24F-V8 DF/DF AT ALL CONTINUOUS OR CANTILEVER APPLICATIONS) FABRICATED AND <br />ERECTED IN ACCORDANCE WITH ANSI/ASTM STANDARD A190.1 AND ASTM D3737. <br />b.ADHESIVE SHALL BE EXTERIOR TYPE ADHESIVE MEETING REQUIREMENTS OF US <br />COMMERCIAL STANDARD PS-56 AND ASTM D3737. <br />c.THE FABRICATOR SHALL FURNISH AITC CERTIFICATES TO THE STRUCTURAL ENGINEER <br />AND THE BUILDING INSPECTION DEPARTMENT PRIOR TO FRAMING INSPECTION. <br />5.ALL LEDGERS SHOULD BE SPLICED WITH ST22 STRAP, U.N.O. <br />6.THE FRAMING CONTRACTOR SHALL NOTIFY THE E.O.R. IN WRITING PRIOR TO <br />CONSTRUCTION IF THE ROOFING DEAD LOAD EXCEEDS 10 PSF. <br />7.STUD WALLS PERPENDICULAR TO CONCRETE OR MASONRY WALLS SHALL BE SECURED <br />USING 5/8" DIAMETER x 8" LONG A307 ANCHOR BOLTS AT THE TOP, MID-HEIGHT, AND <br />BOTTOM. <br />8.INSTALL WINDOWS AND DOORS IN STUD WALLS ONLY AFTER DEAD LOADS HAVE BEEN <br />APPLIED. PROVIDE A 1/2" SHIM GAP AT THE HEAD FOR SETTLEMENT TOLERANCE. <br />9.ALL POSTS SHALL BE CONTINUOUS FROM FOUNDATION TO ROOF. WHERE DISCONTINUITY <br />OCCURS AT JOIST SPACES OR ABOVE BEAMS/HEADERS TO LOWER TOP PLATES, PROVIDE <br />SOLID BLOCKING WITH STUD POSTS. <br />10.ALL VERTICAL PIPES PASSING THROUGH PLATES AND/OR SOLID RIM BEAMS SHALL BE <br />DRILLED WITH CLEAN-CUT HOLES MAINTAINING A 1/16" TOLERANCE. NOTCHING OR <br />CUTTING OF PLATES IS STRICTLY PROHIBITED. <br />11.BLOCKING AND BRIDGING – PROVIDE AS FOLLOWS: <br />a.INSTALL 2X SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL BEARING LOCATIONS. <br />b.INSTALL 2X SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT SPACING NOT TO EXCEED <br />8'-0" ON CENTER, AND NOT MORE THAN 8'-0" FROM ANY SUPPORT. <br />c.BLOCKING MAY BE OMITTED BETWEEN CEILING JOISTS AND RAFTERS THAT ARE 2X8 OR <br />SMALLER. <br />2022 CBC TABLE 2304.10.2 FASTNING SCHEDULE <br />1. JOIST TO SILL OR GIRDER <br />2. BRIDGING TO JOIST <br />3. 1" x 6" SUBFLOOR OR LESS TO EACH JOIST <br />4. WIDER THAN 1" x 6" SUBFLOOR <br /> TO EACH JOIST <br />5. 2" SUBFLOOR TO JOIST OR GIRDER <br />6. SOLE PLATE TO JOIST OR BLOCKING <br />SOLE PLATE TO JOIST OR BLOCKING <br />AT BRACED WALL PANEL <br />7. TOP PLATE TO STUD <br />8. STUD TO SOLE PLATE 2x4 STUD <br />2x6 STUD <br />2x8 STUD <br />9. DOUBLE STUDS <br />6-8D <br />4-16D <br />8-8D <br />6-16D <br />11. BLOCKING BETWEEN JOIST OR RAFTERS <br /> TO TOP PLATE <br />12. RIM JOIST TO TOP PLATE <br />13. TOP PLATES, LAPS AND INTERSECTIONS <br />14. CONTINUOUS HEADER, TWO PIECES <br />15. CEILING JOISTS TO PLATE <br />16. CONTINUOUS HEADER TO STUD <br />17. CEILING JOISTS, LAPS OVER PARTITIONS <br />18. CEILING JOISTS TO PARALLEL RAFTERS <br />19. RAFTER TO PLATE <br />20. 1" DIAGONAL BRACE TO EACH STUD <br /> AND PLATE <br />21. 1" x 8" SHEATHING TO EACH BEARING <br />22. WIDER THAN 1" x 8" SHEATHING TO <br /> EACH BEARING <br />24. BUILT-UP GIRDER AND BEAMS 20D AT 32" O.C. <br />2-20D <br />2. JOIST CAN BE EITHER SAWN LUMBER OR I-JOIST PER PLAN <br />NOTES: 1. COMMON NAILS SHALL BE USED (U.N.O.) <br />3-8D <br />2-8D <br />2-8D <br />3-8D <br />2-16D <br />16D (BOX) AT 16" O.C. <br />(3) 16D (BOX) AT 16" <br />2-16D <br />4-8D <br />2-16D <br />16D (BOX) AT 24" O.C. <br />10. DOUBLED TOP PLATES 16D (BOX) AT 16" O.C. <br /> DOUBLE TOP PLATES 8-16D <br />3-8D <br />8D AT 6" O.C. <br />2-16D <br />16D <br />3-8D <br />4-8D <br />3-16D <br />3-16D <br />3-8D <br />2-8D <br />3-8D <br />3-8D <br />23. BUILT-UP CORNER STUDS 16D <br />25. 2" PLANKS 16D <br />CONNECTION NAILING <br />26. COLLAR TIE TO RAFTER <br />27. JACK RAFTER TO HIP <br />28. ROOF RAFTER TO 2-BY RIDGE BEAM <br />29. JOIST TO BAND JOIST <br />30. LEDGER STRIP <br />3-10D <br />3-10D <br />2-16D <br />2-16D <br />2-16D <br />3-16D <br />3-16D <br />LOCATION <br />TOENAIL <br />TOENAIL EA. END <br />FACE NAIL <br />FACE NAIL <br />BLIND AND FACE NAIL <br />TYPICAL FACE NAIL <br />BRACED WALL PANELS <br />BLIND AND FACE NAIL <br />TOENAIL <br />END NAIL <br />TOENAIL <br />END NAIL <br />TOENAIL <br />END NAIL <br />FACE NAIL <br />TYPICAL FACE NAIL <br />TOENAIL <br />TOENAIL <br />24" O.C. <br />16" O.C. <br />AT EACH BEARING <br />FACE NAIL <br />FACE NAIL <br />16" O.C. ALONG EDGE <br />TOENAIL <br />TOENAIL <br />FACE NAIL <br />FACE NAIL <br />LAP SPLICE <br />TOENAIL <br />FACE NAIL <br />FACE NAIL <br />FACE NAIL <br />FACE NAIL AT TOP & <br />BOTTOM STAGGERED <br />ON OPPOSITE SIDES <br />FACE NAIL AT ENDS & <br />ATEACH SPLICE <br />TOENAIL <br />FACE NAIL <br />TOENAIL <br />FACE NAIL <br />FACE NAIL <br />FACE NAIL <br />NAILING & HARDWARE NOTES <br />1.CONNECTORS FOR WOOD CONSTRUCTION NOTED ON PLANS AND DETAILS SHALL BE <br />SIMPSON COMPANY STRONG-TIE CONNECTORS OR APPROVED EQUAL. <br />2.ALL JOIST HANGERS SHALL BE SIMPSON U HANGER, ALL BEAM HANGERS SHALL BE <br />SIMPSON HU HANGERS U.N.O. ON PLAN OR DETAIL. FOLLOW MANUFACTURER'S <br />RECOMMENDATIONS FOR INSTALLATION. <br />3.ALL MACHINE BOLTS SHALL CONFORM TO ASTM A307. <br />4.TYPICALLY SILLS ON CONCRETE FOOTING SHALL BE ANCHORED WITH 5/8" DIAMETER X 12" <br />MIN. LENGTH MACHINE BOLTS WITH 7" EMBEDMENT AT 72" O.C.. LOCATE BOLTS 6" MIN. <br />AND 12" MAX. FROM EACH END OF EACH STICK. THERE SHALL BE AT LEAST 2 BOLTS IN EACH <br />STICK. <br />5.AT SHEAR WALLS, ANCHOR BOLT SPACING NOT OVER 48" O.C. SEE SHEAR WALL SCHEDULE <br />FOR SPECIFIC SPACING OF ANCHOR BOLTS WHICH MAY BE NOTED AS LESS THAN 48" O.C.. <br />ANCHOR BOLTS SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. x 0.229" THICK <br />BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE WASHERS SHALL BE 1/2" MAX. FROM <br />INSIDE FACE OF SHEAR PANEL(S) PER DETAIL 1/SD.0. <br />6.AT NON SHEAR WALL, ROUND WASHERS SHALL BE USED ON ALL BOLTS AND SHOULD <br />CONFORM WITH ANSI/ASME B 18.22.1. USE MIN. 1 3/8" Ø x 7/64" THICK WASHER FOR 1/2" Ø <br />BOLT, 1 3/4" Ø x 9/64" THICK WASHER FOR 5/8" Ø BOLT AND 2 1/2" Ø x 11/64" THICK <br />WASHER FOR 1" Ø BOLT. U.N.O. <br />7.AT INTERIOR NON-SHEAR WALLS, USE SIMPSON PHNW SERIES 0.145 Ø PINS WITH A <br />PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC <br />ESR-2138. <br />8.WHERE NOTCHES FOR PIPES, ETC. , EXCEED 1/3 THE WIDTH OF THE SILL, PLACE A BOLT <br />WITHIN 6" OF EACH SIDE OF NOTCH. TIEDOWN BOLTS SHALL NOT BE CONSIDERED AS SILL <br />BOLTS. <br />9.BOLT HOLES IN WOOD AND STEEL SHALL BE THE DIAMETER OF THE BOLT PLUS 1/16" <br />10.FASTENERS PENETRATING PRESSURE-PRESERVATIVE TREATED AND FIRE-RETARDANT <br />TREATED WOOD SHALL BE HOT DEPPED GALVANIZED PER ASTM A153, CLASS D. <br />11.ALL NAILS SHALL BE SINKER NAILS AND STAGGERED U.N.O., EXCEPT AS SHOWN IN NAILING <br />SCHEDULE. <br />12.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR <br />GALVANIZED BOX. <br />13.LAG SCREWS PER ANSI/ASME STANDARD B18.2.1 PROVIDE LEAD HOLE SAME DIAMETER <br />AND DEPTH AS SHANK AND THEN DRILL HOLE 60%-70% OF SHANK DIAMETER FOR <br />THREADED PORTIONS. <br />FOUNDATION NOTES <br />1.REFER TO NOTE #1 UNDER REINFORCED CONCRETE FOR CONCRETE STRENGTH <br />SPECIFICATIONS. <br />2.THE REQUIREMENTS OUTLINED IN CHAPTER 18 OF THE CBC MUST BE ADHERED TO AS THE <br />MINIMUM STANDARD UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED IN THE <br />DRAWINGS OR TECHNICAL SPECIFICATIONS. <br />3.ALL CONCRETE SHALL MEET THE REQUIRED STRENGTH AND SLUMP PER STRUCTURAL <br />DESIGN. WHEN EXPOSED TO SULFATE-CONTAINING SOLUTIONS, IT SHALL CONFORM TO <br />ASTM C-150 TYPE V PORTLAND CEMENT AND COMPLY WITH CBC SECTION 1904 (ACI 318 <br />SECTION 19.3.2.1). AGGREGATES MUST MEET ASTM C-33 STANDARDS, AND MIXING WATER <br />MUST BE CLEAN AND POTABLE. <br />4.CONCRETE PLACEMENT MUST BE PERFORMED AS A CONTINUOUS OPERATION UNLESS <br />OTHERWISE SPECIFIED. THE SLAB SURFACE SHALL BE CURED USING 'HUNTS' COMPOUND <br />OR AN EQUIVALENT PRODUCT, OR BY OTHER METHODS IN ACCORDANCE WITH INDUSTRY <br />BEST PRACTICES. <br />5.CALCIUM CHLORIDE-CONTAINING ADMIXTURES SHALL NOT BE USED IN THE CONCRETE <br />MIX. <br />6.BEFORE PLACING CONCRETE, THE CONTRACTOR SHALL MOISTEN THE SAND/MEMBRANE <br />UNDERLAYMENT TO ENSURE UNIFORM CURING. CONCRETE SLABS SHALL NOT BE POURED <br />DURING OR IMMEDIATELY AFTER RAINFALL. THE SAND LAYER BENEATH VISQUEEN MUST <br />NOT BE SATURATED AT THE TIME OF THE POUR, AND ANY STANDING WATER MUST BE <br />REMOVED PRIOR TO PLACEMENT. <br />7.EXCAVATED FOOTING BOTTOMS MUST BE LEVEL, CLEAN, AND FREE OF LOOSE MATERIALS <br />OR WATER BEFORE CONCRETE IS POURED. OVER-EXCAVATED AREAS MUST BE BACKFILLED <br />WITH CONCRETE OR PROPERLY COMPACTED FILL. BACKFILLING SHOULD NOT OCCUR UNTIL <br />THE SUPPORTING FOUNDATION, WALLS, AND SLAB HAVE REACHED ADEQUATE STRENGTH <br />TO RESIST LATERAL SOIL PRESSURE. <br />8.FOOTINGS MUST REST ON UNDISTURBED NATIVE SOIL. <br />9.ALL EXCAVATIONS MUST BE PROPERLY BACKFILLED WITH NON-EXPANSIVE SOIL. HOWEVER, <br />BACKFILL BEHIND RETAINING WALLS MUST ONLY BE PLACED AFTER THE CONCRETE OR <br />MASONRY HAS REACHED ITS FULL DESIGN STRENGTH. <br />10.IF NO GEOTECHNICAL REPORT IS PROVIDED, IT IS THE RESPONSIBILITY OF THE LICENSED <br />GENERAL CONTRACTOR OR OWNER-BUILDER TO VERIFY THAT THE STRUCTURE IS ENTIRELY <br />SITUATED ON UNDISTURBED, NON-EXPANSIVE NATIVE SOIL. IF FILL, EXPANSIVE SOIL, OR <br />ANY SIGNS OF GEOLOGICAL INSTABILITY ARE SUSPECTED, THE GEOTECHNICAL ENGINEER <br />AND THE ENGINEER OF RECORD MUST BE CONSULTED TO MODIFY THE DESIGN <br />ACCORDINGLY. <br />11.PRESATURATION REQUIREMENTS FOR SUBGRADE SOILS AND SETBACK DISTANCES FOR <br />EXTERIOR FOOTINGS FROM DESCENDING SLOPES MUST BE FOLLOWED. <br />12.THE FINISHED GRADE AROUND THE PERIMETER OF THE SLAB SHALL BE CONSTRUCTED TO <br />ENSURE THAT RAIN AND IRRIGATION WATER DRAINS AWAY FROM THE STRUCTURE. <br />13.SITE AND PAD PREPARATION, INCLUDING BUT NOT LIMITED TO GRADING, FILL <br />COMPACTION, PRESATURATION, AND CONCRETE SLAB BASE PREPARATION, SHALL BE <br />COMPLETED AS REQUIRED. <br />14.FOUNDATION DRAWINGS PREPARED BY THE ENGINEER OF RECORD REFLECT STRUCTURAL <br />REQUIREMENTS. FOR DIMENSIONS, SLOPES, RECESSES, SHELVES, PATIOS, STOOPS, AND <br />PORCHES NOT INDICATED IN THE FOUNDATION DRAWINGS, REFER TO THE ARCHITECTURAL <br />PLANS. THE CONTRACTOR AND ARCHITECT MUST VERIFY ALL DIMENSIONS BEFORE <br />CONSTRUCTION TO ENSURE PROPER FIT. <br />15.WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING SURFACE <br />SHALL BE ROUGHENED TO A MINIMUM AMPLITUDE OF 1/4". <br />16.GRADE BEAMS SHALL BE POURED MONOLITHICALLY ALONG THEIR ENTIRE LENGTH. <br />17.ALUMINUM CONDUIT, SLEEVES, AND EMBEDS ARE NOT PERMITTED IN CONCRETE. <br />18.NO PIPES OR CONDUITS SHALL PASS BENEATH ISOLATED COLUMN FOOTINGS OR <br />CONTINUOUS WALL FOOTINGS UNLESS SPECIFICALLY DETAILED AND APPROVED BY THE <br />ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL. <br />19.ALL CONDUITS SHALL BE PLACED WITHIN THE MIDDLE ONE-THIRD OF THE SLAB THICKNESS. <br />THE MAXIMUM CONDUIT DIAMETER SHALL BE 1-1/4", AND CONDUITS MUST BE SPACED AT <br />LEAST 4 INCHES APART FROM EACH OTHER AND FROM REINFORCING STEEL UNLESS <br />OTHERWISE APPROVED BY THE STRUCTURAL ENGINEER. <br />20.A MINIMUM OF ONE #4 REINFORCING BAR SHALL BE PROVIDED FOR ELECTRICAL <br />GROUNDING, WITH THE LOCATION VERIFIED WITH THE ELECTRICAL CONTRACTOR. <br />21.ALL HOLDOWNS AND POST ANCHORS MUST BE SECURED IN PLACE PRIOR TO THE <br />FOUNDATION INSPECTION. <br />SHEET INDEX <br />GENERAL NOTES & REQUIREMENTS. <br />FOUNDATION DETAILS. <br />S-0 <br />S-1 FRAMING PLANS. <br />SD.0 TYPICAL DETAILS. <br />SD.1 <br />STRUCTURAL DETAILS.SD.2 <br />GENERAL NOTES <br />DESIGN CRITERIA <br />BUILDING CODE <br />A. GENERAL <br />2022 CBC <br />RISK CATEGORY II <br />SOIL ENGINIEER SOILS REPORT EXEMPTIONS <br />REPORT NUMBER PCC-06  <br />DATE 7/1/2024  <br />ALLOWABLE SOIL BEARING PRESSURE 1500 psf <br />SITE CLASS <br />D <br />SHORT PERIOD SPECTRAL ACCELERATION, Ss <br />1 <br />1ST PERIOD SPECTRAL ACCELERATION, S1 <br />D-DEFAULT <br />SHORT PERIOD ACCELERATION PARAMETER, SDS <br />1.334 <br />1 SECOND ACCELERATION PARAMETER, SD1 <br />0.475 <br />SEISMIC RESPONSE COEFFIECIENT, Cs <br />1.067 <br />0.578 <br />RESPONSE MODIFICATION FACTOR, R 6.5 <br />SEISMIC DESIGN CATEGORY <br />0.164 <br />SEISMIC IMPORTANCE FACTOR, Ie <br />DESIGN BASE SHEAR V = 0.7CsW 0.115W <br />B. SOIL PARAMETERS <br />D. LATERAL DESIGN PARAMETERS <br />DESIGN SPEED <br />EXPOSURE CATEGORY <br />95 mph <br />C <br />C. GRAVITY DESIGN PARAMETERS (psf) <br />DEAD <br />ROOF LIVE <br />LIVE <br />15 <br />20 <br />ROOF EXTERIOR WALL INTERIOR WALL <br />17 <br />- <br />LOAD <br />10 <br />1.REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S <br />INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED <br />EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT <br />DATE IS SHOWN. <br />2.STRUCTURAL INFORMATION SHOWN ON FRAMING PLANS IS FOR THE MAIN STRUCTURAL <br />ELEMENTS. NON-STRUCTURAL ELEMENTS SHALL BE CONSTRUCTED PER APPROVED CODE <br />REQUIREMENTS. <br />3.DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE SHOWN <br />FOR SIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL SHEETS FOR TYPICAL DETAILS OF <br />CONSTRUCTION. TYPICAL DETAILS APPLY TO ALL CONSTRUCTION UNLESS SPECIFICALLY <br />NOTED OR SHOWN OTHERWISE. WHERE CONDITIONS REQUIRE MODIFICATIONS OF A <br />TYPICAL DETAIL, THE CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE <br />EOR TO FABRICATION AND INSTALLATION. <br />4.DO NOT USE SCALED DIMENSIONS, USE WRITTEN DIMENSIONS. WHERE NO DIMENSION IS <br />PROVIDE, CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE <br />WORK. FIELD MEASURE EXISTING DIMENSIONS NOT NOTED. <br />5.OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWINGS, NOTES, AND <br />DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND RESOLVED <br />BEFORE PROCEEDING WITH THE WORK. <br />6.THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING UTILITIES BEFORE BEGINNING <br />WORK. SPECIAL CARE SHALL BE TAKEN TO PROJECT UTILITIES THAT ARE TO REMAIN IN <br />SERVICE DURING CONSTRUCTION. <br />7.THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITING OF ANY DEVIATION FROM <br />THE CONTRACT DOCUMENTS. <br />8.DRAWINGS AND SPECIFICATIONS REPRESENT FINISHED STRUCTURE. CONTRACTOR SHALL <br />BE RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, INCLUDING BUT NOT <br />LIMITED TO SHORING AND TEMPORARY BRACING. THE CONTRACTOR SHALL TAKE ALL <br />NECESSARY MEASURES TO INSURE SAFETY OF ALL PERSONS AND STRUCTURES AT THE SITE <br />AND ADJACENT TO THE SITE. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT, <br />ENGINEER OR CONSTRUCTION MANAGER SHALL NOT RELIEVE THE CONTRACTOR OF SUCH <br />RESPONSIBILITY. <br />9.SPECIFICATIONS RELATED TO WATERPROOFING, INCLUDING BUT NOT LIMITED TO <br />MEMBRANES, WATERSTOPS, SEALANTS, FLASHING, VAPOR BARRIER, ARE AS SPECIFIED BY <br />ARCHITECT/WATER PROOFING CONSULTANT. <br />10.CONSTRUCTION MATERIALS SHALL BE DISTRIBUTED WHEN PLACED ON THE STRUCTURE <br />SUCH THAT LOADS DO NOT EXCEED DESIGN LIVE LOADS OR RESULT IN AN UNBALANCED <br />CONDITION. <br />11.APPROVAL FROM THE AUTHORITY HAVING JURISDICTION MUST BE OBTAINED PRIOR TO <br />INSTALLATION OF ITEMS REQUIRING DEFERRED SUBMITTAL. <br />12.STRUCTURAL ELEMENTS INDICATED AS "BY OTHERS" ARE NOT INCLUDED IN THIS SCOPE OF <br />WORK. <br />13.THE GENERAL CONTRACTOR SHALL PROVIDE SEPARATE SUBMITTALS FOR SUCH ELEMENTS <br />TO THE ENGINEER OF RECORD FOR REVIEW. UPON EOR ACCEPTANCE, SUBMITTALS SHALL BE <br />FORWARDED TO THE BUILDING DEPARTMENT FOR FINAL REVIEW AND APPROVAL. <br />WIND PARAMETERS <br />SEISMIC PARAMETERS <br />MAIN LATERAL RESISTING SYSTEM WOOD SHEARWALL <br />8 <br />- <br />CEILING <br />10 <br />1 <br />1 <br />SPECIAL INSPECTION: <br />INSPECTION SCHEDULE <br />SOIL CONDITION (SOIL REPORT) <br />POST INSTALLED ANCHORS <br />STRUCTURAL STEEL <br />STRUCTURAL STEEL WELDING <br />HIGH STRENGTH BOLTING <br />MASSONRY WORK <br />COLD FORMED STEEL <br />CAST IN PLACE DEEP FOUNDATION <br />REQ'D <br />INSPECTION ITEMS CODE REFERENCE <br />CBC Table 1705.3.8, ICC APPROVAL <br />CBC 1705.2 <br />CBC 1705.2 <br />CBC 1705.2 <br />CBC 1705.4 <br />CBC 1705.12.2, 1705.13.3 <br />CBC Table 1705.8 <br />CBC Table 1705.6 <br />EPOXY DOWELS ESR 4057 <br />1.SPECIAL INSPECTIONS SHALL BE CONDUCTED IN ACCORDANCE WITH CBC CHAPTER 17. <br />REFER TO THE INSPECTION SCHEDULE BELOW - ONLY THE MARKED ITEMS ARE REQUIRED. <br />2.THE OWNER MUST HIRE ONE OR MORE QUALIFIED SPECIAL INSPECTORS TO OVERSEE <br />CONSTRUCTION INSPECTIONS. THESE INSPECTORS MUST DEMONSTRATE COMPETENCY IN <br />THEIR SPECIFIC FIELD OF INSPECTION TO THE SATISFACTION OF THE BUILDING OFFICIAL. <br />3.WHEN WORK IS PERFORMED AT AN APPROVED AND REGISTERED FABRICATION FACILITY, <br />SPECIAL INSPECTIONS MAY NOT BE NECESSARY. APPROVED FABRICATORS MUST PROVIDE <br />A COMPLIANCE CERTIFICATE FOR OFFSITE FABRICATION OF STRUCTURAL COMPONENTS <br />SUCH AS PRECAST CONCRETE, GLUED LAMINATED TIMBER, AND STRUCTURAL STEEL. <br />4.INDEPENDENT SPECIAL INSPECTORS MUST CONDUCT ALL REQUIRED INSPECTIONS. SITE <br />VISITS BY THE STRUCTURAL ENGINEER OR BUILDING OFFICIAL DO NOT REPLACE OR FULFILL <br />THE SPECIAL INSPECTION REQUIREMENTS. <br />5.INSPECTION REPORTS SHALL BE SUBMITTED TO BOTH THE BUILDING OFFICIAL AND THE <br />ENGINEER OF RECORD (E.O.R.). FINAL REPORTS FROM SPECIAL INSPECTORS MUST VERIFY <br />THAT THE STRUCTURAL SYSTEM CONFORMS TO THE APPROVED DESIGN DOCUMENTS. <br />6.ENSURING THAT ALL REQUIRED INSPECTIONS ARE COMPLETED IS THE SOLE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />7.WORK REQUIRING SPECIAL INSPECTION MUST BE REVIEWED BY THE DESIGNATED SPECIAL <br />INSPECTOR BOTH DURING CONSTRUCTION AND UPON COMPLETION. CONTINUOUS <br />INSPECTION REQUIRES FULL-TIME SUPERVISION, WHEREAS PERIODIC INSPECTION IS <br />CONDUCTED INTERMITTENTLY. <br />8.FOR STRUCTURAL WOOD COMPONENTS, PERIODIC INSPECTIONS ARE REQUIRED FOR <br />WOOD SHEAR WALLS, SHEAR PANELS, DIAPHRAGMS, AND THEIR FASTENING SYSTEMS, <br />INCLUDING NAILING, BOLTING, ANCHORING, AND CONNECTIONS OF SEISMIC <br />FORCE-RESISTING ELEMENTS SUCH AS DRAG STRUTS, BRACES, AND HOLDOWNS. <br />EXCEPTION: SPECIAL INSPECTION IS NOT NEEDED WHEN THE SHEATHING FASTENER <br />SPACING EXCEEDS 4 INCHES ON CENTER. INSPECTIONS MUST TAKE PLACE BEFORE THE <br />WORK IS COVERED. <br />9.THE SPECIAL INSPECTIONS LISTED ARE IN ADDITION TO THOSE PERFORMED BY THE <br />BUILDING OFFICIAL. THIS LIST IS NOT EXHAUSTIVE. <br />STRUCTURAL WOOD (NOTE #8)CBC 1705.12.1, 1705.13.2 <br />CONCRETE/SHOTCRETE WORK CBC Table 1705.3 <br />REINFORCING STEEL CBC Table 1705.2.2, 1705.3 <br />HIGH-STRENGTH NON-SHRINK GROUT CBC 1705.2, 1705.3 <br />REINFORCING STEEL NOTES <br />1.REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 FOR ALL SIZES. <br />2.ALL REINFORCING TO BE ACCURATELY AND SECURELY LOCATED PRIOR TO POURING <br />CONCRETE. <br />3.ALL HORIZONTAL REINFORCEMENT TO HAVE MATCHING DOWELS AT CORNERS OF WALLS. <br />ALL VERTICAL REINFORCEMENT TO HAVE MATCHING DOWELS TO FOOTING, U.O.N. <br />4.COVERAGE SHALL BE: 3" CLEAR FOR CONCRETE CAST AGAINST EARTH, 2" CLEAR FOR <br />CONCRETE EXPOSED TO MOISTURE BUT NOT CAST AGAINST EARTH, AND 1 1/2" FOR ALL <br />OTHER CONDITIONS. (U.N.O) <br />GENERAL <br />NOTES <br />S-0 <br />DESCRIPTIONREV.DATE <br />STAMP: <br />SHEET TITLE: <br />SHEET NUMBER: <br />AD <br />U <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br />PROJECT: <br />80 <br />5 <br /> <br />C <br />L <br />E <br />M <br />E <br />N <br />S <br />E <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />1 PC1 01-17-2026 <br />ENGINEER OF RECORD: <br />VENKATA ROHIT GRANDHI, P.E <br />7823 Boxwood Ct, <br />Highland, CA 92346 <br />rohith.grandi@gmail.com <br />09/04/202012/14/202401.18.2026