Laserfiche WebLink
CITY OF SAWA. ANA <br />Planning and Building ency <br />Em ENPHASE® <br />IQ Battery 10C <br />The IQ Battery 10C all -in -one AC -coupled system is compact, powerful, <br />reliable, and safe. It has a total usable capacity' of 10.0 kWh and includes <br />four embedded, grid -forming microinverters with a 7.08 kVA continuous <br />power rating. It provides backup capability, and installers can quickly <br />design the right system size to meet the customer's needs. <br />Rated (continuous) output power <br />Rated output current (@240 VL-LAG-) <br />Rated neutral current (@120 VL-N AC-) <br />Interconnection <br />Nominal voltage <br />Nominal frequency <br />Usable capacity <br />Ambient operating temperature range <br />(charging)' <br />Ambient operating temperature range <br />(discharging)' <br />Chemistry <br />Mounting <br />Product dimensions <br />7.08 kVA' <br />29.5 A' <br />24 A' <br />Single-phase <br />120/240 VAC- <br />60 Hz <br />10.0 kWh' <br />-20°C to 50°C (-4°F to 122°F) <br />Non -condensing <br />-2O`C to 55°C (-4°F to 131T) <br />Non -condensing <br />Lithium iron phosphate (LFP) <br />Wall -mount or pedestal -mount (sold <br />separately) <br />14- 4— 4"' <br />4 <br />J 4"' <br />24.5" <br />15' aaN � <br />`Ey'EM0„� <br />28" 14.4" — <br />r - <br />4" <br />The 4" clearances on the sides and the top are per the UL 9540A evaluation, Enphase recommends 8" for ease of service. <br />"Follow the local and national regulations while planning. A 15" clearance in the front is recommended for ease of service. <br />'Refer to the following page for more details. <br />NORTH AMERICA <br />® Powerful <br />• Provides 56 A peak current for <br />three seconds <br />• Includes four embedded <br />IQBB Microinverters <br />• Most powerful microinverter with <br />up to 2.1 kVA continuous power <br />G Reliable <br />• Cools passively with no moving <br />parts or fans <br />• Uses wired communication for fast <br />and consistent connection <br />• Updates software and firmware <br />remotely <br />O Simple <br />• Fully integrated AC Battery system <br />with neutral forming capabilities <br />• Installs and commissions easily <br />• Offers homeowners remote <br />monitoring and control from the <br />Enphase App <br />• Field replaceable components <br />O Safe <br />• Evaluated to UL 9540A, the highest <br />industry standard for battery safety <br />• Uses LFP chemistry for maximum <br />safety and longevity <br />Name <br />Description <br />Model Number <br />Ordering SKU <br />5 kWh battery unit <br />IQ Battery 10C cover kit <br />IQ Battery 10C unit <br />Rated (continuous) output power <br />Nominal voltage/range <br />Nominal frequency/range <br />Rated output current (@240 VL-LAC-) <br />Rated neutral current (@240 VL-NAC-) <br />Peak output current (@240 VL-LAC-) <br />Power Start capability <br />Power factor (adjustable) <br />Maximum conductor size supported <br />Overcurrent protection device (OCPD) <br />Interconnection <br />AC round-trip efficiency' <br />Total capacity10 <br />Usable capacity" <br />DC round-trip efficiency <br />Nominal DC voltage <br />Maximum DC voltage <br />IQ Battery 10C <br />The IQ Battery 10C system with integrated IQ Microinverters (S <br />with a battery management system (BMS) as part of IQBL Micr <br />Two 5 kWh battery units (ordering SKU: B05-001-USOC <br />One IQ Battery 10CS cover kit with cover, interconnect <br />accessories (Ordering SKU: B10CS-NC-0708-0-DOM). <br />FOR PERMIT ISSUANCE <br />IQBBL, IQBBN) <br />ierters, includes: <br />laster.ID: <br />and <br />I QBATTERY-10C-1 P-NA2 <br />Standard Domestic <br />B05-001-US00-1-3 B05-001-US00-1-3-DOM <br />B10C-NC-0708-0 B10C-NC-0708-0-DOM <br />60% capacity, up to 15 years, or 6,000 cycles' <br />7.08 kVAS <br />240/211-264 VAC- <br />60/57-63 Hz <br />29.5 AS <br />24 A <br />56 A (three seconds), 44.8 A (ten seconds) <br />Up to 90 A LRA7 <br />0.85 leading ... 0.85 lagging <br />3AWG <br />40 A OCPD, requires a minimum of 8 AWG for one IQ Battery 10C <br />or <br />80 A OCPD, requires a minimum of 4 AWG for two or more IQ Battery 1008 <br />Single-phase <br />90% <br />10.0 kWh <br />10.0 kWh <br />96% <br />76.8 V <br />86.4 V <br />The model number is used on the product nameplate, Certificate of Compliance, and in official regulatory listings (e.g., California Energy Commission). For all interconnection applications and <br />permitting processes, please ensure that the model number is used —not the ordering SKU. <br />Whichever occurs first. Restrictions apply. <br />" Supported in both grid -connected and backup/off-grid operations. <br />s 7.08 kVA, 29.5 A for the balanced 240 VL-L loads. <br />a A maximum of 24 A, 120 VI-N unbalanced loads can be supported along with 5.5 A, 240 V L_L loads. <br />7 Power Start capability may vary. <br />a More than two IQ Battery IOC on a 4 AWG circuit protected by 80 A OCPD requires setting Power Control System: IQ Battery Oversubscription. <br />AC to the battery to AC at 50% power rating. <br />1O The IQ Battery 10C is typically shipped with a state of charge (SoC) between 20%and 30%to ensure safe transportation and optimal battery health during storage and handling. <br />" The battery's usable capacity supports loads and turns PV on (when off -grid), in normal daily operation. The usable capacity includes a safety -critical limit of 2%that safeguards the customer's asset <br />in case of a long -duration grid outage. An additional 3%capacity is maintained for battery electronic sustenance at night. Refer to https://Iink.enphase.com/iqbattery-usable-capacity_en-na for <br />more information. <br />© 2025 Enphase Energy. All rights reserved. Enphase, the a and CC logos. IQ and certain other marks listed at DSH-00565-6.0-EN-2025-07-31 <br />httos://enohase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. DSH-00565-6.0-EN-2025-07-31 <br />