My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1113 N Wright St - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Wright St
>
1113 N Wright St
>
1113 N Wright St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2026 5:00:10 AM
Creation date
5/29/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20188593
Full Address
1113 N Wright St
Street Number
1113
Street Direction
N
Street Name
Wright
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
5.2 Battery import/export-only mode for Enphase Energy System <br />Enphase IQ Batteries can operate either in the battery import-only mode or in the battery export-only <br />mode. <br />NOTE: Battery modes are selectable only if the battery installation is in California. <br />5.2.1 Battery import-only mode <br />The import-only mode feature for IQ Battery 10C ensures that the battery never exports power to the <br />grid. The feature is certified for any systems that have a UL Listed PV inverter. <br />System sizing for battery import-only mode with IQ Battery 10C <br />Enphase Power Control with battery import-only mode ensures no IQ Battery current is exported to <br />the main panel. This is accomplished by measuring and controlling all production current and power. <br />Enphase Power Control ensures that the current at the Consumption CTs never exceeds the PV <br />production current, thus never exporting battery current past the Consumption CTs. <br />In the battery import-only mode, the Enphase Energy System does not export battery current past <br />the Consumption CTs. Therefore, the current from IQ Batteries need not be accounted for when <br />calculating the current exported to the grid by the system. As a result, installers only need to account <br />for the size of the PV system while calculating export, and need not account for the size of the <br />IQ Battery system installed. This saves labor and upgrade costs for installers and system owners. <br />NOTE: Power Control System is covered in Article 705.13 of the NEC 2020 edition. Authorities <br />Having Jurisdiction (AHJs) may not recognize the Power Control System feature until the 2020 <br />NEC is adopted in their region. <br />Open loop response time <br />The maximum open loop response time (OLRT) with battery import-only mode in the <br />Enphase Energy System is less than two seconds. <br />Enphase Power Control features <br />23 © 2025 Enphase Energy Inc. All rights reserved. August 2025 <br />TEB-00269-2.0-EN <br />5.2.2 Battery export-only mode <br />Battery export is the only mode for IQ Battery 10C that allows the IQ Battery to export to the grid. This <br />feature is certified with any UL Listed PV inverters. <br />Homeowners can leverage this feature to lower their payback period on their solar plus battery <br />systems, as Enphase ensures that the IQ Battery stores the excess PV production and exports to the <br />grid when it is most beneficial to the homeowner based on the import and export tariff rates. <br />System sizing for battery export-only mode with IQ Battery 10C <br />Enphase Power Control with Battery export-only mode ensures that the IQ Battery never imports <br />from the grid. It is performed by ensuring that the battery charge current measured at the Battery <br />CT is always less than the PV production current measured at the Production CT. Battery discharge is <br />only ensured to obey other Power Control System features. <br />In Battery export-only mode, as Enphase Energy System exports battery current to the grid, the <br />current from IQ Batteries must be accounted for when calculating the current exported to the grid <br />by the system. However, the Battery export-only mode can be paired with other Enphase Power <br />Control features that allow for the installation of large Enphase solar plus battery systems without <br />the need for main panel upgradation costs or additional labor costs if the Enphase system has <br />IQ8 Series Microinverters. <br />Open loop response time <br />The maximum open loop response time (OLRT) with battery export mode in the <br />Enphase Energy System is less than two seconds. <br />5.2.3 Operation of battery import/export-only mode with other Enphase Power <br />Control features <br />Battery import/export-only mode works in conjunction with other Enphase Power Control <br />features— IQ Battery over-subscription, MPU avoidance, and Aggregate Power Export Limit. <br />Enphase Energy System ensures that the power control limits set with respect to the other features <br />are adhered to when the battery export or import-only modes are enabled. <br />5.2.4 Configuring battery import/export-only mode via the Enphase Installer App <br />Under System Details, go to PCS based Limiting > Battery Mode. Then, select Import Only or Export <br />Only. The battery mode selection expires in seven days, starting from the selection of the tariff <br />structure. <br />The selection of mode is not possible in the Enphase Installer App if seven days have elapsed after the <br />selection of the tariff structure. <br />NOTE: Battery export-only mode is currently only available in jurisdictions with Net Energy <br />Metering 3.0 (NEM 3.0). In jurisdictions other than NEM 3.0, the battery mode is set to battery <br />import-only mode by default. <br />Enphase Power Control features <br />24 © 2025 Enphase Energy Inc. All rights reserved. August 2025 <br />TEB-00269-2.0-EN