CHAPTER 4
<br />RESIDENTIAL MANDATORY MEASURES
<br />DIVISION 4.1 PLANNING AND DESIGN
<br />DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION
<br />4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE
<br />4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in
<br />sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such
<br />openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing
<br />agency.
<br />4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING
<br />4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65
<br />percent of the non-hazardous construction and demolition waste in accordance with either Section
<br />4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste
<br />management ordinance.
<br />Exceptions:
<br />1. Excavated soil and land-clearing debris.
<br />2. Alternate waste reduction methods developed by working with local agencies if diversion or
<br /> recycle facilities capable of compliance with this item do not exist or are not located reasonably
<br /> close to the jobsite.
<br />3. The enforcing agency may make exceptions to the requirements of this section when isolated
<br /> jobsites are located in areas beyond the haul boundaries of the diversion facility.
<br />4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan
<br />in conformance with Items 1 through 5. The construction waste management plan shall be updated as
<br />necessary and shall be available during construction for examination by the enforcing agency.
<br />1. Identify the construction and demolition waste materials to be diverted from disposal by recycling,
<br /> reuse on the project or salvage for future use or sale.
<br />2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or
<br /> bulk mixed (single stream).
<br />3. Identify diversion facilities where the construction and demolition waste material collected will be
<br /> taken.
<br />4. Identify construction methods employed to reduce the amount of construction and demolition waste
<br /> generated.
<br />5. Specify that the amount of construction and demolition waste materials diverted shall be calculated
<br /> by weight or volume, but not by both.
<br />4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the
<br />enforcing agency, which can provide verifiable documentation that the percentage of construction and
<br />demolition waste material diverted from the landfill complies with Section 4.408.1.
<br />Note: The owner or contractor may make the determination if the construction and demolition waste
<br />materials will be diverted by a waste management company.
<br />4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined
<br />weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4
<br />lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in
<br />Section 4.408.1
<br />4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined
<br />weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds
<br />per square foot of the building area, shall meet the minimum 65% construction waste reduction
<br />requirement in Section 4.408.1
<br />4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates
<br />compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4..
<br />Notes:
<br />1. Sample forms found in "A Guide to the California Green Building Standards Code
<br /> (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in
<br /> documenting compliance with this section.
<br />2. Mixed construction and demolition debris (C & D) processors can be located at the California
<br /> Department of Resources Recycling and Recovery (CalRecycle).
<br />4.410 BUILDING MAINTENANCE AND OPERATION
<br />4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact
<br />disc, web-based reference or other media acceptable to the enforcing agency which includes all of the
<br />following shall be placed in the building:
<br />1. Directions to the owner or occupant that the manual shall remain with the building throughout the
<br /> life cycle of the structure.
<br />2. Operation and maintenance instructions for the following:
<br />a. Equipment and appliances, including water-saving devices and systems, HVAC systems,
<br /> photovoltaic systems, electric vehicle chargers, water-heating systems and other major
<br /> appliances and equipment.
<br />b. Roof and yard drainage, including gutters and downspouts.
<br />c. Space conditioning systems, including condensers and air filters.
<br />d. Landscape irrigation systems.
<br />e. Water reuse systems.
<br />3. Information from local utility, water and waste recovery providers on methods to further reduce
<br /> resource consumption, including recycle programs and locations.
<br />4. Public transportation and/or carpool options available in the area.
<br />5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent
<br /> and what methods an occupant may use to maintain the relative humidity level in that range.
<br />6. Information about water-conserving landscape and irrigation design and controllers which conserve
<br /> water.
<br />7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5
<br /> feet away from the foundation.
<br />8. Information on required routine maintenance measures, including, but not limited to, caulking,
<br /> painting, grading around the building, etc.
<br />9. Information about state solar energy and incentive programs available.
<br />10. A copy of all special inspections verifications required by the enforcing agency or this code.
<br />11. Information from the Department of Forestry and Fire Protection on maintenance of defensible
<br />space around residential structures.
<br />12. Information and/or drawings identifying the location of grab bar reinforcements.
<br />4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a
<br />building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the
<br />depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper,
<br />corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling
<br />ordinance, if more restrictive.
<br />Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section
<br />42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of
<br />this section.
<br />DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE
<br />EFFICIENCY
<br />DIVISION 4.5 ENVIRONMENTAL QUALITY
<br />4.303 INDOOR WATER USE
<br />4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and
<br />urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3,
<br />and 4.303.4.4.
<br />Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving
<br />plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final
<br />completion, certificate of occupancy, or final permit approval by the local building department. See Civil
<br />Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential
<br />buildings affected and other important enactment dates.
<br />4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per
<br />flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense
<br />Specification for Tank-type Toilets.
<br />Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume
<br />of two reduced flushes and one full flush.
<br />4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush.
<br />The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush.
<br />4.303.1.3 Showerheads.
<br />4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8
<br />gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA
<br />WaterSense Specification for Showerheads.
<br />4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one
<br />showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by
<br />a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only
<br />allow one shower outlet to be in operation at a time.
<br />Note: A hand-held shower shall be considered a showerhead.
<br />4.303.1.4 Faucets.
<br />4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall
<br />not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall
<br />not be less than 0.8 gallons per minute at 20 psi.
<br />4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory
<br />faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential
<br />buildings shall not exceed 0.5 gallons per minute at 60 psi.
<br />4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver
<br />more than 0.2 gallons per cycle.
<br />4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons
<br />per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not
<br />to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per
<br />minute at 60 psi.
<br />Note: Where complying faucets are unavailable, aerators or other means may be used to achieve
<br />reduction.
<br />4.303.1.4.5 Pre-rinse spray valves.
<br />When installed, commercial pre-rinse spray values shall meet the requirements in the California Plumbing
<br />Code, Section 420.3.
<br />4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial
<br />buildings.
<br />Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the
<br />California Plumbing Code.
<br />4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in
<br />accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table
<br />1701.1 of the California Plumbing Code.
<br />4.304 OUTDOOR WATER USE
<br />4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with
<br />a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water
<br />Efficient Landscape Ordinance (MWELO), whichever is more stringent.
<br />NOTES:
<br />1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations,
<br /> Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are
<br /> available at: https://www.water.ca.gov/
<br />ABBREVIATION DEFINITIONS:
<br />HCD Department of Housing and Community Development
<br />BSC California Building Standards Commission
<br />DSA-SS Division of the State Architect, Structural Safety
<br />OSHPD Office of Statewide Health Planning and Development
<br />LR Low Rise
<br />HR High Rise
<br />AA Additions and Alterations
<br />N New
<br />SECTION 4.102 DEFINITIONS
<br />4.102.1 DEFINITIONS
<br />The following terms are defined in Chapter 2 (and are included here for reference)
<br />FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar
<br />pervious material used to collect or channel drainage or runoff water.
<br />WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials
<br />such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also
<br />used for perimeter and inlet controls.
<br />4.106 SITE DEVELOPMENT
<br />4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation
<br />and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes,
<br />management of storm water drainage and erosion controls shall comply with this section.
<br />4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less
<br />than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre
<br />or more, shall manage storm water drainage during construction. In order to manage storm water drainage
<br />during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent
<br />property, prevent erosion and retain soil runoff on the site.
<br />1. Retention basins of sufficient size shall be utilized to retain storm water on the site.
<br />2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar
<br /> disposal method, water shall be filtered by use of a barrier system, wattle or other method approved
<br /> by the enforcing agency.
<br />3. Compliance with a lawfully enacted storm water management ordinance.
<br />Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or
<br />are part of a larger common plan of development which in total disturbs one acre or more of soil.
<br />(Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html)
<br />4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will
<br />manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface
<br />water include, but are not limited to, the following:
<br />1. Swales
<br />2. Water collection and disposal systems
<br />3. French drains
<br />4. Water retention gardens
<br />5. Other water measures which keep surface water away from buildings and aid in groundwater
<br /> recharge.
<br />Exception: Additions and alterations not altering the drainage path.
<br />4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Section 4.106.4.1
<br />or 4.106.4.2. Electric vehicle supply equipment (EVSE) shall comply with the California Electrical Code.
<br />Exceptions:
<br />1. On a case-by-case basis, where the local enforcing agency has determined EV charging and
<br /> infrastructure are not feasible based upon one or more of the following conditions:
<br />1.1 Where there is no local utility power supply or the local utility is unable to supply adequate
<br />power.
<br />1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional
<br />local utility infrastructure design requirements, directly related to the implementation of Section
<br />4.106.4, may adversely impact the construction cost of the project.
<br />2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional
<br /> parking facilities.
<br />4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each
<br />dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway
<br />shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main
<br />service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the
<br />proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or
<br />concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere
<br />208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit
<br />overcurrent protective device.
<br />Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is
<br />installed in close proximity to the proposed location of an EV charger at the time of original construction in
<br />accordance with the California Electrical Code.
<br />4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent
<br />protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination
<br />location shall be permanently and visibly marked as "EV CAPABLE".
<br />CHAPTER 3
<br />GREEN BUILDING
<br />SECTION 301 GENERAL
<br />301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in
<br />the application checklists contained in this code. Voluntary green building measures are also included in the
<br />application checklists and may be included in the design and construction of structures covered by this code,
<br />but are not required unless adopted by a city, county, or city and county as specified in Section 101.7.
<br />301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to
<br />additions or alterations of existing residential buildings where the addition or alteration increases the
<br />building's conditioned area, volume, or size. The requirements shall apply only to and/or within the
<br />specific area of the addition or alteration.
<br />The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking
<br />facilities or the addition of new parking facilities serving existing multifamily buildings. See Section
<br />4.106.4.3 for application.
<br />Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing
<br />lighting fixtures are not considered alterations for the purpose of this section.
<br />Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or
<br />improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures.
<br />Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate
<br />of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1,
<br />et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and
<br />other important enactment dates.
<br />301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of
<br />individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential
<br />buildings, or both. Individual sections will be designated by banners to indicate where the section applies
<br />specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and
<br />high-rise buildings, no banner will be used.
<br />SECTION 302 MIXED OCCUPANCY BUILDINGS
<br />302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building
<br />shall comply with the specific green building measures applicable to each specific occupancy.
<br />Exceptions:
<br />1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall
<br />comply with Chapter 4 and Appendix A4, as applicable.
<br />2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California
<br />Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with
<br />Chapter 4 and Appendix A4, as applicable.
<br />4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities.
<br />When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the
<br />requirements of Section 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A
<br />parking space served by electric vehicle supply equipment or designed as an EV charging space shall count as at
<br />least one standard automobile parking space only for the purpose of complying with any applicable minimum parking
<br />space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details.
<br />4.106.4.2.1 Reserved.
<br />4.106.4.2.2 Multifamily dwellings, hotels and motels
<br />1. EV ready parking spaces with receptacles.
<br />a. Multifamily parking facilities with assigned parking. Where dwelling units are provided with
<br />assigned parking spaces equal to or greater than the number of dwelling units, at least one low power
<br />Level 2 EV charging receptacle shall be provided at an assigned parking space for each dwelling unit.
<br />1. Where the total number of dwelling units exceeds the number of assigned parking spaces, all assigned
<br />parking spaces shall be provided with one low power Level 2 EV charging receptacle.
<br />
<br />Exception: Areas of parking facilities served by parking lifts, including but not limited to, automated
<br />mechanical-access open parking garages as defined in the California Building Code; or parking
<br />facilities otherwise incapable of supporting electric vehicle charging.
<br />b. Multifamily parking facilities with unassigned parking. Where dwelling units are provided with
<br />unassigned parking spaces equal to or greater than the number of dwelling units, at least one low
<br />power Level 2 EV charging receptacle shall be provided at an unassigned parking space for each
<br />dwelling unit.
<br />1. Where the total number of dwelling units exceeds the number of unassigned parking spaces, all
<br />unassigned parking spaces shall be provided with one low power Level 2 EV charging receptacle.
<br />
<br />Exception: Areas of parking facilities served by parking lifts, including but not limited to, automated
<br />mechanical-access open parking garages as defined in the California Building Code; or parking
<br />facilities otherwise incapable of supporting electric vehicle charging.
<br />3. Multifamily parking facilities with assigned and unassigned parking. Where multifamily buildings
<br />are provided with both assigned and unassigned parking spaces equal to or greater than the number of
<br />dwelling units, at least one low power Level 2 EV charging receptacle shall be provided for each dwelling
<br />unit at either the assigned or unassigned parking space, but not both.
<br />d. Receptacle power source. EV charging receptacles in multifamily parking facilities at assigned
<br />parking spaces shall be provided with a dedicated branch circuit connected to the dwelling unit’s electrical
<br />panel, unless determined as infeasible by the project builder or designer and subject to concurrence of
<br />the local enforcing agency.
<br />Exception: Areas of parking facilities served by parking lifts, including but not limited to, automated
<br />mechanical-access open parking garages as defined in the California Building Code; or parking
<br />facilities otherwise incapable of supporting electric vehicle charging.
<br />e. Receptacle configurations. 208/240V EV charging receptacles shall comply with one of the following
<br />configurations:
<br />1. For 20-ampere receptacles, NEMA 6-20R
<br />2. For 30-ampere receptacles, NEMA 14-30R
<br />3. For 50-ampere receptacles, NEMA 14-50R
<br />2. EV ready parking spaces with EV chargers
<br /> a .Multifamily parking facilities with unassigned or common use parking. In addition to the low
<br />power Level 2 EV charging receptacle requirements of Section 4.106.4.2.2 (1), twenty-five (25) percent of
<br />unassigned or common use parking spaces not already provided with low power Level 2 EV charging
<br />receptacles, pursuant to Section 4.106.4.2.2 (1), shall be equipped with Level 2 EV chargers and shall be
<br />made available for use by all residents or guests.
<br />b. EV charger connectors. EV chargers shall be equipped with J1772 or J3400 connectors.
<br />c. An automatic load management system (ALMS) may be used to reduce the maximum required
<br />electrical capacity to each space served by the ALMS. The electrical system and any on-site
<br />distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each
<br />EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40
<br />amperes, and installed EV chargers shall have a capacity of not less than 30 amperes.
<br />4.106.4.2.2.1 Electric vehicle charging stations (EVCS).
<br />Electric vehicle charging stations required by Section 4.106.4.2.2, Item 2, with EV chargers installed shall
<br />comply with Section 4.106.4.2.2.1.1.
<br />Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels
<br />shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable
<br />requirements.
<br />4.106.4.2.2.1.1 Electric vehicle charging stations (EVCS) spaces with EV chargers installed; dimensions
<br />and location.
<br />EVCS spaces shall be designed to comply with the following:
<br />1.The minimum length of each EVCS space shall be 18 feet (5486 mm).
<br />2.The minimum width of each EVCS space shall be 9 feet (2743 mm).
<br />3.One in every 25 EVCS spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum
<br />aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the
<br />EVCS space is 12 feet (3658 mm). Surface slope for this EVCS space and the aisle shall not exceed 1
<br />unit vertical in 48 units horizontal (2.083 percent slope) in any direction. These EVCS spaces shall also
<br />comply with at least one of the following:
<br />a. The EVCS space shall be located adjacent to an accessible parking space meeting the requirements
<br />of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking
<br />space.
<br />b. The EVCS space shall be located on an accessible route, as defined in the California Building Code,
<br />Chapter 2, to the building.
<br />Exception: Electric vehicle charging stations designed and constructed in compliance with the California
<br />Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1.
<br />4.106.4.2.2.1.2 Accessible electric vehicle charging station spaces.
<br />In addition to the requirements in Section 4.106.4.2.2.1.1, all EV chargers, where installed, shall comply with the
<br />accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and
<br />EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A.
<br />4.106.4.2.3 Reserved.
<br />4.106.4.2.4 Reserved.
<br />4.106.4.2.5 Electric vehicle ready space signage.
<br />Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans
<br />Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its
<br />successor(s).
<br />4.106.4.2.6 Hotels and motels.
<br /> 1. EV ready parking spaces with receptacles.
<br />
<br />a. Hotels and motels. Forty (40) percent of the total number of parking spaces shall be equipped with
<br />low power Level 2 EV charging receptacles.
<br />Exception: Areas of parking facilities served by parking lifts, including but not limited to automated
<br />mechanical-access open parking garages as defined in the California Building Code; or parking facilities
<br />otherwise incapable of supporting electric vehicle charging.
<br />
<br />b. Receptacle configurations. 208/240V EV charging receptacles shall comply with one of the following
<br />configurations:
<br /> 1.For 20- ampere receptacles, NEMA 6-20R
<br /> 2.For 30- ampere receptacles, NEMA 14-30R
<br /> 3.For 50- ampere receptacles, NEMA 14-50R2.
<br />2. EV Ready parking spaces with EV chargers.
<br />
<br />a. Hotels and motels. Twenty-five (25) percent of the total number of parking spaces shall be equipped
<br />with Level 2 EV chargers.
<br /> b. EV charger connectors. EV chargers shall be equipped with J1772 or J3400 connectors.
<br /> Exception: Areas of parking facilities served by parking lifts, including but not limited to, automated
<br />mechanical-access open parking garages as defined in the California Building Code; or parking facilities
<br />otherwise incapable of supporting electric vehicle charging.
<br />SECTION 4.501 GENERAL
<br />4.501.1 Scope
<br />The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous,
<br />irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors.
<br />SECTION 4.502 DEFINITIONS
<br />5.102.1 DEFINITIONS
<br />The following terms are defined in Chapter 2 (and are included here for reference)
<br />AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door
<br />cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements.
<br />COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and
<br />medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood,
<br />structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated
<br />wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section
<br />93120.1.
<br />DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for
<br />combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere.
<br />Y N/AYN/AYN/AYN/A RESPON.
<br />PARTY
<br />RESPON.
<br />PARTY
<br />RESPON.
<br />PARTY
<br />RESPON.
<br />PARTY
<br />2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
<br />RESIDENTIAL MANDATORY MEASURES, SHEET 1 Y = YES
<br />N/A =NOT APPLICABLE
<br />RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER,
<br />OWNER, CONTRACTOR, INSPECTOR ETC.)
<br />4.201 GENERAL
<br />4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy
<br />Commission will continue to adopt mandatory standards.
<br />DIVISION 4.2 ENERGY EFFICIENCY
<br />c. An automatic load management system (ALMS) may be used to reduce the maximum required
<br />electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution
<br />transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging
<br />station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes,
<br />and installed EV chargers shall have a capacity of not less than 30 amperes.
<br />4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing
<br />multi-family buildings, hotels and motels.
<br /> When existing parking facilities are altered or new parking spaces are added to existing parking facilities, and
<br />the work requires a building permit, each parking space added or altered shall have access to either a low
<br />power Level 2 EV charging receptacle or Level 2 EV charger, unless determined as infeasible by the project
<br />builder or designer and subject to concurrence of the local enforcing agency.
<br />
<br />Exception: Where work requiring a permit is being performed for the installation of 120-volt electrical
<br />receptacle(s) for level 1 EV charging.
<br />4.106.4.4 Bicycle parking. Bicycle parking shall comply with Sections 4.106.4.4.1 through 4.106.4.4.3.
<br /> 4.106.4.4.1 Short-term bicycle parking for multifamily buildings, hotels and motels. Provide on-site bicycle
<br />parking at a ratio of one parking space for every 10,000 square feet, but not less than two spaces. Short-term
<br />bicycle parking shall be located within 200 feet of building entrances, and readily visible to passers-by.
<br />Acceptable parking facilities shall be conveniently accessed from the street and may include, but not be limited
<br />to:
<br /> 1.Permanently anchored bicycle parking devices, racks, or lockers in an unsheltered, open area.
<br /> 2.Covered or uncovered enclosures with permanently anchored bicycle parking devices or racks.
<br /> 4.106.4.4.2 Long-term bicycle parking for multifamily buildings.
<br />Provide on-site bicycle parking at a ratio of one parking space for every two dwelling units. Acceptable parking
<br />facilities shall be conveniently accessed from the street and may include, but not be limited to:
<br />1. Covered, lockable enclosures with permanently anchored bicycle parking devices or racks.
<br /> 2. Lockable bicycle storage rooms with permanently anchored bicycle parking devices or racks.
<br /> 3. Lockable, weatherproof, permanently anchored bicycle lockers.
<br /> 4.106.4.4.3 Long-term bicycle parking for hotel and motel buildings.
<br />Provide one on-site long-term bicycle parking space for every 25,000 square feet, but not less than two.
<br />Acceptable parking facilities shall be conveniently accessed from the street and may include, but not be limited
<br />to:
<br />1. Covered, lockable enclosures with permanently anchored bicycle parking devices or racks.
<br /> 2. Lockable bicycle storage rooms with permanently anchored bicycle parking devices or racks.
<br /> 3. Lockable, weatherproof, permanently anchored bicycle lockers.
<br />GREEN BUILDING
<br />STANDARDS
<br />G2.0
<br />SHEET NO.
<br />DATE
<br />JOB NO.
<br />SHEET NAME
<br />DRAWN
<br />REVISIONS
<br />ENGINEERS STAMP:
<br />DATE
<br />THESE DRAWINGS AND SPECIFICATIONS AND IDEAS,
<br />DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY
<br />ARE AND SHALL REMAIN THE PROPERTY OF THE
<br />ENGINEER. NO PART THEREOF SHALL BE COPIED,
<br />DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH
<br />ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
<br />PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND
<br />DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE
<br />ENGINEER. VISUAL CONTACT WITH THESE DRAWINGS OR
<br />SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE
<br />EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.
<br />1
<br />2
<br />3
<br />4
<br />HADLEY ENGINEERING
<br />CO
<br />P
<br />Y
<br />R
<br />I
<br />G
<br />H
<br />T
<br />
<br />©
<br />
<br />2
<br />0
<br />2
<br />5
<br />
<br />H
<br />A
<br />D
<br />L
<br />E
<br />Y
<br />
<br />E
<br />N
<br />G
<br />I
<br />N
<br />E
<br />E
<br />R
<br />I
<br />N
<br />G
<br />NOTE: PLANS SHALL BE CONSIDERED PRELIMINARY
<br />AND NOT FOR CONSTRUCTION IF SEAL ABOVE IS NOT
<br />SIGNED IN WET INK AND IF NOT APPROVED BY LOCAL
<br />BUILDING JURISDICTION.
<br />909-446-0712
<br />THOMAS W. HADLEY S.E.
<br />34159 Yucaipa, Blvd. Suite C Yucaipa, CA. 92399
<br />THADLEY@HADLEYENGINEERING.COM
<br />Re
<br />p
<br />a
<br />i
<br />r
<br />
<br />P
<br />l
<br />a
<br />n
<br />s
<br />Se
<br />r
<br />v
<br />p
<br />r
<br />o
<br />
<br />/
<br />
<br />S
<br />u
<br />n
<br />r
<br />i
<br />s
<br />e
<br />
<br />P
<br />r
<br />o
<br />p
<br />e
<br />r
<br />t
<br />i
<br />e
<br />s
<br />
<br />U
<br />n
<br />i
<br />t
<br />
<br />1
<br />13
<br />2
<br />3
<br />
<br />S
<br />p
<br />u
<br />r
<br />g
<br />e
<br />o
<br />n
<br />
<br />S
<br />t
<br />r
<br />e
<br />e
<br />t
<br />,
<br />
<br />U
<br />n
<br />i
<br />t
<br />
<br />1
<br />Sa
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />CITY PLANNING
<br />DIVISION COMMENTS 11/6/2025
<br />CITY COMMENTS 2/16/2026
<br />APPROVED
<br />1323 N Spurgeon St #1
<br />Allissa Zuniga
<br />5/28/2026
|