Laserfiche WebLink
1 SC-311110MA WALL UTILITY CABINET RIGHT <br />FACE MOUNT RIGHT SIDE <br />OF HOOD <br />HOOD # 1 <br />1 LIGHT <br />1 FAN <br />SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY <br />ON/OFF WITH SUPPLY <br />EXHAUST <br />SUPPLY <br />3 <br />3 <br />5.000 <br />2.000 <br />208 <br />208 <br />15.2 <br />6.1 <br />NO TAG PACKAGE #LOCATION <br />SWITCHES <br />LOCATION QUANTITY <br />OPTION <br />FANS CONTROLLED <br />TYPE ΙΈ HP VOLT FLA <br />Field Connection Antennas <br />Wired OR Paddle <br />Field Connection to Router <br />OR Ethernet switch <br />Connection for Modbus <br />Factory wired OR Field Wired <br />Terminal Blocks for wired connection <br />Cellular Module <br />Compute module <br />DESCRIPTION OF OPERATION: <br />7480959 <br />Food-to-Go - 328 Harbor <br />SC-311110MA <br />4/21/2025 <br />INSTALL <br />ECP #1-1 <br />3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. <br />Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. <br />BREAKER PANEL TO PRIMARY CONTROL PANEL <br />Responsibility: Electrician <br />BREAKER PANEL PRIMARY CONTROL PANEL <br />BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED <br />BREAKER 1PH <br />CONTROL POWER. DO NOT WIRE <br />TO SHUNT TRIP BREAKER. <br />Hot <br />Neutral <br />H1 <br />N1120 V <br />15 A <br />Ground GND <br />1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. <br />SWITCH #1 <br />WIRE TO VFD QUICK CONNECTOR <br />BREAKER 3PH <br />MCA: <br />MOCP: <br />LINE <br />LINE <br />Ground <br />EXH-1 SM-1 <br />GND <br />L1 <br />L2 <br />LINE L3208 V <br />19.0 A <br />30 A <br />BREAKER 3PH <br />WIRE TO VFD QUICK CONNECTOR <br />MCA: <br />MOCP: <br />LINE <br />LINE <br />208 V <br />Ground <br />SUP-2 SM-2 <br />GND <br />L4 <br />L5 <br />LINE L67.6 A <br />15 A <br />CONTROL PANEL TO FANS <br />Responsibility: Electrician <br />PRIMARY PANEL FANS <br />Load Wiring <br />WIRE TO <br />VFD QUICK <br />WIRE TO <br />DISCONNECT <br />CONNECTOR <br />MUST HAVE ITS OWN CONDUIT <br />DO NOT SHARE CONDUIT! <br />FLA: <br />HP: <br />VOLT: <br />EXH-101 <br />LOAD LEG 1 <br />LOAD LEG 2 <br />GND GROUND <br />FAN: <br />SM-1 <br />LOAD LEG 3 <br />U1 <br />V1 <br />W1 <br />15.2 <br />5.000 <br />208 V <br />Load Wiring BLACK <br />BLACK <br />BLACK <br />GREEN <br />WIRE TO <br />VFD QUICK <br />CONNECTOR WHITE <br />RED <br />FLA: <br />HP: <br />VOLT: <br />MUST HAVE ITS OWN CONDUIT <br />DO NOT SHARE CONDUIT! <br />IF VFD MOUNTED IN <br />2ND PANEL, WIRE SF <br />SIGNAL FROM PANEL <br />WITH ECPM03. <br />U2 <br />V2 <br />W2 <br />LOAD LEG 1 <br />LOAD LEG 2 <br />LOAD LEG 3 <br />GND GROUND <br />SUP-202FAN: <br />SM-2 <br />N1 120V NEUTRAL <br />120V HOT <br />N1 <br />6.1 <br />2.000 <br />208 V <br />H1 <br />CONTROL PANEL TO ACCESSORY ITEMS <br />Responsibility: Electrician <br />CONTROL PANEL COMPONENT <br />WIRE DIRECTLY TO CONTROL BOARD <br />CAT-5 CONNECTION <br />CONTROL PANEL <br />REMOTE <br />TO <br />MOUNTED <br />SWITCHES <br />PLACE END OF LINE PLUG <br />EOL120AIN EMPTY JACK. PN: EOL120A <br />HMI <br />J4 1 <br />2 <br />CONTROL PANEL <br />HOOD LIGHTS <br />TO <br />1400 W MAX WIRE TO J-BOX ON TOP OF HOOD <br />B1 <br />W1 <br />GND <br />BLACK <br />WHITE <br />GREEN <br />HOOD LIGHTS 1 <br />WIRE DIRECTLY TO COMMUNICATION <br />ROUTERCOMM <br />MODULE. NET REQUIRES 1) DHCP 2) <br />UDP PORT 1444 & 1445 OPEN FOR <br />CAT-5 ETHERNET CONNECTION <br />CONTROL PANEL <br />WORLD WIDE <br />TO <br />WEB <br />OUTBOUND TRAFFIC ONLY. <br /> -- <br />WIRE TO CONTROL BOARD. INSTALL <br />SENSOR IN ROOM AWAY FROM HEAT <br />SOURCES. DO NOT INSTALL SENSOR <br />CONTROL PANEL <br />KITCHEN TEMP <br />TO <br />SENSOR <br />ON THE CEILING GRID, SEE MANUAL. <br />T1A <br />T1B ROOM TEMP <br />WIRE TO CONTROL BOARD. <br />SENSOR MOUNTED IN EXHAUST DUCT <br />CONTROL PANEL <br />DUCT SENSOR <br />TO <br />T2A <br />T2B HOOD 1 <br />RISER 1 <br />CONTROL PANEL <br />GAS VALVE <br />TO <br />120V ONLY <br />ONLY ENERGIZED THROUGH LCD <br />HMI WHEN FIRE SYSTEM ARMED. <br />GAS <br />N1 <br />HOT TO GAS VALVE <br />NEUTRAL <br />GAS SOLENOID <br />THE FOLLOWING CONNECTIONS <br />MAY OR MAY NOT BE <br />REQUIRED BASED ON JOBSITE <br />SPECIFICATIONS <br />CONTROL PANEL <br />EXTERNAL <br />SIGNAL FOR <br />SHUNT TRIP <br />ST TERMINAL IS ENERGIZED <br />IN FIRE CONDITION. <br />ST <br />N1 NEUTRAL FROM SHUNT COIL <br />HOT TO SHUNT COIL SHUNT COIL <br />KS <br />N1 NEUTRAL_TO_CONTACTOR_COIL <br />HOT_TO_CONTACTOR_COIL CONTACTOR_COIL <br />SPARE CONTACTS WILL MAKE <br />CONTROL PANEL <br />ON/OFF WITH <br />DRY CONTACT <br />SUPPLY FAN <br />COMMON TO NORMALLY OPEN <br />WHEN SUPPLY FAN IS ON. <br />GROUP 1 <br />SFC1 <br />SFO1 <br />COMMON <br />NORMALLY OPEN <br />SFC2 <br />SFO2 <br />COMMON <br />NORMALLY OPEN <br />CONTROL PANEL <br />EXTERNAL <br />TO <br />SWITCH <br />SIGNAL SWITCH THROUGH BMS <br />WILL ACTIVATE ZONE1 FANS AND <br />LIGHTS <br />H1 <br />IO1 <br />BMS SWITCH <br />C NO <br />CONTROL PANEL <br />GAS VALVE <br />TO <br />24V DC ONLY <br />ONLY ENERGIZED THROUGH LCD <br />HMI WHEN FIRE SYSTEM ARMED. <br />(NOT NEEDED IF USING 120V <br />GAS VALVE). <br />LGV <br />N1D <br />POSITIVE TO GAS VALVE <br />NEGATIVE <br />GAS SOLENOID <br />CONTROL PANEL TO FIRE SYSTEM <br />Responsibility: ALARM CONTRACTOR <br />CONTROL PANEL COMPONENT <br />CONTROL PANEL <br />BUILDING <br />SIGNAL FOR <br />FIRE ALARM <br />PANEL <br />AL1 <br />AL2 <br />J9 <br />BUILDING <br />ALARM PANEL <br />FIRE INPUT <br />WIRE DIRECTLY TO CORE CIRCUIT <br />BOARD. AL1 WILL MAKE AL2 IN FIRE <br />CONDITION. <br />CONTROL PANEL <br />BUILDING <br />SIGNAL FOR <br />TROUBLE TROUBLE RELAY CONTACTS WILL <br />MAKE TBC TO TBL IN TROUBLE <br />CONDITION. <br />BUILDING <br />ALARM PANEL <br />ALARM <br />TBC <br />TBL <br />COMMON <br />NORMALLY CLOSED <br />CONTROL PANEL TO FIRE SYSTEM <br />Responsibility: CERTIFIED INSTALLER <br />CONTROL PANEL COMPONENT <br />FIRE STAT SUPERVISED LOOP <br />May be mixed factory and field wiring. See <br />Installation Schematic. Multiple fire sensors <br />possible. <br />HIGH TEMP WIRE (842 F), PN: SLPCON-xFT <br />required for all Supervised Loop wiring in <br />contact with a hood. All other wiring shall be <br />PN: 6320UL, Belden or similar. <br />21 <br />22 <br />23 <br />24 <br />FS-01 <br />BK WH <br />Fire Stat <br />FS-02 <br />BK WH <br />Fire Stat <br />CONTROL PANEL <br />MOUNTED FIRE <br />TO DUCT <br />DETECTION <br />STAT(S) <br />FIRE STATS <br />DESCRIPTION OF OPERATION: <br />7480959 <br />Food-to-Go - 328 Harbor <br />SC-311110MA <br />4/21/2025 <br />INSTALL <br />ECP #1-2 <br />3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. <br />Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. <br />CONTROL PANEL <br />SYSTEM PULL <br />TO FIRE <br />STATION <br />MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. <br />Multiple manual actuation possible. <br />Multiple manual actuation possible. <br />A Plug jumper with wires from pin1 to pin4 and from pin2 <br />to pin3 is mounted on J10, remove the jumpers and <br />wire in the supervised actuation loop. <br />Microswitch MS-01 is optional for fire <br />system interlock. <br />Auxiliary Interlock (AUX-01): <br />Wire AU1 / AU2 of adjacent Master FS panel(s) in each <br />manual activation loop for simultaneous activation. See <br />Fire system drawings for more information. <br />101 <br />102 <br />103 <br />104 <br />AUX-01 <br />AU1 AU2 <br />PULL STATION <br />MS-01 <br />C NO <br />Micro SW <br />MAD-01 <br />C NO <br />Manual <br />Actuation <br />Device <br />Adjacent <br />FS <br />Panel <br />CAT-5 CONNECTIONCONTROL PANEL <br />MASTER FS <br />TO <br />BOARD. <br />PLACE END OF LINE PLUG <br />EOL120AIN EMPTY JACK. PN: EOL120A <br />CORE PCB <br />ADDITIONAL DEVICES MAY BE INLINE. <br />ECPM03 <br />UNLESS VFD, PCU, <br />OR OTHER COMPONENT IN SERIES. <br />J3 J5 <br />J6 <br />CONTROL PANEL <br />MASTER FS <br />TO <br />PANEL <br />WIRE TO LIKE TERMINALS IN ALL <br />CORE PANELS THAT MUST ACTIVATE <br />TOGETHER. SET MASTER & SLAVE <br />DIP SWITCHES PER FIRE SYSTEM <br />SHIELDED TWISTED PAIRINTERLOCK NETWORK MASTER CORE <br />MANUAL. <br />CA <br />CB <br />CC <br />BLACK <br />RED <br />SHIELD <br />CA <br />CB <br />CC <br />DESCRIPTION OF OPERATION: <br />7480959 <br />Food-to-Go - 328 Harbor <br />SC-311110MA <br />4/21/2025 <br />INSTALL <br />ECP #1-3 <br />Fire System #1 TANK FS - 4.0/4.0. <br />FS-1: MASTER <br />DESCRIPTION OF OPERATION: <br />7480959 <br />Food-to-Go - 328 Harbor <br />SC-311110MA <br />4/21/2025 <br />INSTALL <br />ECP #1-4 <br />Fire System #1 TANK FS - 4.0/4.0. <br />FS-1: MASTER <br />M2.3 <br />HOOD <br />KITCHEN <br />SHEET <br />TITLE <br />PROJECT <br />TITLE <br />NO <br />. <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />THESE DRAWINGS & SPECIFICATIONS ARE THE <br />EXCLUSIVE PROPERTY OF TND STUDIO. THE USE <br />OF THESE PLANS AND SPECIFICATIONS SHALL BE <br />RESTRICTED TO THE ORIGINAL SITE FOR WHICH <br />T H E Y W E R E P R E P A R E D . R E P R O D U C T I O N , <br />PUBLICATION OR RE-USE, IN WHOLE OR IN PART <br />I S PROHIBITED WITHOUT THE EXPRESS PRIOR <br />WR ITT EN C ONSEN T OF TND ST UDI O. TI T LE T O <br />T H E D R A W I N G S R E M A I N S W I T H T N D S T U D I O <br />WI T HO UT PR E JU DI CE. VI S UAL CON T A CT WI T H <br />T H E S E P L A N S A N D S P E C I F I C A T I O N S S H A L L <br />CO N S T IT UTE PR IM A -F AC I E EVI DEN C E O F T H E <br />ACCEPTANCE OF THESE RESTRICTIONS AND THE <br />T E R M S F O U N D H E R E I N . <br />CLIENT <br />STAMP <br />SHEET <br />FIRE PROTECTION <br />SPECIFICATIONS