DESCRIPTION OF OPERATION: <br />FS-1: MASTER <br />WH <br />BK <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />FACTORY WIRING <br />SCHEMATIC <br />CIRCUIT BOARDS <br />MOTOR POWER CIRCUIT <br />PANEL LID <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />PN: <br />ST-X <br />varies <br />Starter <br />PN: <br />OL-X <br />varies <br />Overload <br />PN: <br />C-X <br />varies <br />Contactor <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />PN: <br />PS-1 <br />MDP18-24A-1C <br />Power Sup. 24VDC <br />BK <br />PN: <br />RA-x <br />34.110.0184.0 <br />120V Relay DPDT <br />WH <br />PN: <br />RA-x <br />34.110.0184.0 <br />120V Relay DPDT <br />GR <br />UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. <br />N1 <br />H1 <br />DC <br />- <br />GN <br />D <br />DC <br />+ <br />8H1 <br />7PCU <br />6ST <br />5KS <br />4KTS <br />3GAS <br />2AR1 <br />1N1 <br />120VJ9 <br />5OV1 <br />4SF1 <br />3EF1 <br />2B1 <br />1IO1 <br />120VJ7 <br />AR1 <br />H12x <br />N12x <br />B1 <br />EF1 <br />SF1 <br />BK IO1 <br />BK <br />BK <br />BK <br />JUMPERW1 <br />BK 14AWG BK <br />64 <br />RD-1 <br />BL PRDC+RO1 <br />PN: <br />RD-x <br />34.110.0188.0 <br />24VDC Light Relay <br />BK WHSF1RA-2 <br />RD-1 <br />24V <br />1 2 3 4 5 6 7 <br />8 9 10 11 12 13 14 <br />J6 <br />N1N1 <br />RO <br />1 <br />FAN <br />PANEL COOLING <br />DRY CONTACTS (SHOWN DE-ENERGIZED) <br />HOOD LIGHTS <br />J3 <br />ECPM03/DAISY CHAIN <br />AR1 H1JUMPER FIRE SYSTEM <br />BK <br />BK <br />BK <br />GAS <br />KS <br />ST <br />SM-1 SM-2 <br />ECPM03 <br />J10 <br />IL <br />1 <br />A <br />IL <br />1 <br />B <br />JUMPER <br />MAKE UP AIR INTERLOCK. <br />1 <br />2 <br />11 <br />1 JUMPER <br />1 <br />2 <br />11 <br />1 JUMPER <br />NOTE: All items on ECPM03 J3 line to be daisy chained <br />from one component to the next, with EOL120A at end <br />of line. Place PN: EOL120A in empty RJ45 port. <br />NOTE: Configure ECPM03 for COREJ3 <br />ECPM03 or Previous EOL <br />J5 <br />MASTER CORE <br />FIELD WIRED <br />RA-2-1 <br />SFC1 <br />SFO1 <br />14 AWG <br />YW <br />RA-2-2 <br />SFC2 <br />SFO2 <br />14 AWG <br />YW <br />24 X 18 X 8.62 BOX <br />CONTROL INPUT 120V H1=LINE, <br />N1=NEUTRAL, 15A BREAKER. DO <br />NOT CONNECT TO SHUNT TRIP <br />BREAKER. SEE INSTALLATION <br />SCHEMATIC FOR ADDITIONAL <br />REQ. <br />LEGEND <br />FIELD WIRING <br />FACTORY WIRING <br />BK- BLACK YW- YELLOW <br />BL- BLUE GY- GREY <br />BR- BROWN PR- PURPLE <br />OR- ORANGE RD- RED <br />WH- WHITE <br />OR/BL- OR/BL STRIPE <br />BL/RD- BL/RD STRIPE <br />RD/GN- RD/GN STRIPE <br />WH/BL- WH/BL STRIPE <br />WH <br />/ <br />B <br />L <br />BL <br />H1N1 <br />DC <br />- <br />DC <br />+ <br />LN <br />-+ <br />PS-01 <br />AC <br />24V <br />GN <br />D <br />DCKSKSBKKS <br />BK <br />BK <br />GAS <br />ST <br />BKEF1 <br />PR <br />WH <br />GR <br />/ <br />Y <br />W <br />WH <br />/ <br />B <br />L <br />BL <br />J4 J5 <br />FAN <br />SECONDARY PANEL COOLING IF NECESSARY <br />EF1 WHBK <br />J1 <br />ECPM03 <br />SCADA <br />WIRED BK <br />RD <br />+ <br />- <br />DEST <br />DEST <br />ILB <br />ILC <br />ILA <br />DEST <br />DEST <br />TO ETH <br />CAT-5 <br />PN: <br />SCADA SCADA Module <br />SHDANT <br />Wired to <br />Master CORE <br />(if applicable) <br />Use shielded wire <br />BK <br />RD <br />SD <br />JUMPER <br />ECPM03 <br />J10 <br />IL <br />2 <br />A <br />IL <br />2 <br />B <br />TERMINAL GAS USED FOR 120V <br />POWERED GAS VALVES ONLY <br />7480959 <br />Food-to-Go - 328... <br />FACTORY <br />SC-311110MA <br />4/21/2025 <br />ECP #1-6 <br />3 Phase w/ control for 1 Exhaust <br />Fan, 1 Supply Fan, Exhaust on in <br />Fire, Lights out in Fire, Relay <br />On/Off with Supply Fan, Fan(s) <br />On/Off Thermostatically <br />Controlled. Room temperature <br />sensor shipped loose for field <br />installation. INVERTER DUTY 3 <br />PHASE MOTOR REQUIRED FOR USE <br />WITH VFD. <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />U/T1 <br />V/T2 <br />W/T3 <br />L1 <br />L2 <br />L3/N <br />GR <br />GR <br />GND <br />VFD: <br />HP: <br />MTR: <br />FLA: <br />P107: <br />P108: <br />P410: <br />P150: <br />P100: <br />P194: <br />P101: <br />P131: <br />P167: <br />P103: <br />P102: <br />L1 <br />L2 <br />L3 <br />12 AWG <br />3 PH <br />30 A <br />208 V <br />U1 <br />V1 <br />W1 <br />SM-1 <br />ESV402N02TXB571 225 <br />01 <br />01 <br />11 <br />92 <br />00 <br />15.2 <br />5.000 <br />EXH-1 <br />N/A <br />N/A <br />64.8 <br />64.8 <br />0.0 <br />GND <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />U/T1 <br />V/T2 <br />W/T3 <br />L1 <br />L2 <br />L3/N <br />GR <br />GR <br />GND <br />VFD: <br />HP: <br />MTR: <br />FLA: <br />P107: <br />P108: <br />P410: <br />P150: <br />P100: <br />P194: <br />P101: <br />P131: <br />P167: <br />P103: <br />P102: <br />L4 <br />L5 <br />L6 <br />14 AWG <br />3 PH <br />15 A <br />208 V <br />U2 <br />V2 <br />W2 <br />SM-2 <br />ESV152N02YXB571 225 <br />01 <br />01 <br />21 <br />87 <br />00 <br />6.1 <br />2.000 <br />SUP-2 <br />N/A <br />N/A <br />53.3 <br />50.2 <br />0.0 <br />GND <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />FACTORY WIRING <br />SCHEMATIC <br />CORE FIRE PROTECTION <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />24 VOLT BATTERY PACK <br />5 AMP FUSE <br />RD <br />SHIELDED TWISTED PAIR <br />PCB-2 <br />J3-2 <br />J4-1 <br />J3-11 <br />J4-3 <br />J4-2 <br />J4-8 <br />J4-9 <br />J4-12 <br />J3-14 <br />J4-5 <br />J3-13 <br />J3-4 <br />J4-6 <br />J3-10 <br />J2-1 <br />J2-2 <br />J2-3 <br />J2-4 <br />J7-2 <br />J7-3 <br />J7-1 <br />J3-1 J3-3 <br />RD <br />RD BR <br />RD <br />ALL 18AWG <br />RD BK <br />ORRD <br />PKRD <br />BRRD <br />RD OR/BL <br />BK 18AWG <br />BK <br />BK <br />J3-5 <br />J1-1 <br />J1-2 <br />RD <br />BK <br />BK <br />RD <br />FIRE STAT SUPERVISED LOOP <br />May be mixed factory and field wiring. See <br />Installation Schematic. Multiple fire sensors <br />possible. <br />+ <br />+ <br />RD <br />BK <br />BK <br />RD <br />Shield <br />BK <br />RD <br />RS-485 CORE INTERLOCK NETWORK. <br />Connection to other CORE Panels <br />or Communication Module. See <br />Installation Schematic for <br />Connection. <br />N1D 3xH1D3x <br />DISCONNECT J1 <br />21 <br />22 <br />23 <br />24 <br />16AWG <br />WHN1 <br />H1 <br />PN: 1606-XLP-60EQ <br />Adjust power supply to 27.5 Volts with <br />an accurate Digital Volt Meter or with <br />an HMI plugged into the CORE board. <br />NL <br />+- <br />PSM-2 60W <br />GR <br />BK <br />GND <br />PN: <br />PCB-2 <br />PCBCORE-APP <br />CORE PCB <br />PN: <br />PS-02 <br />1606-XLP-60E <br />CORE POWER SUPPLY <br />PN: <br />WS-x <br />varies <br />Water Solenoid <br />PN: <br />LT-06 <br />WL-1090D1-28V <br />24V Red Ind. Light <br />PN: <br />LL-01 <br />AQ5510 <br />Surf. Level Sensor <br />PN: <br />AA-01 <br />SCE120LA3FP1B <br />Audible Alarm <br />PN: <br />PB-XX <br />ZB4BA2/ZB4BZ1015 <br />Prime/Reset Switch <br />PN: <br />SW-04 <br />BZ-2RQ1-A2 <br />Tamper Switch <br />PN: <br />SP-1 <br />50000-805 <br />Surfactant Pump <br />PB-01 <br />Prime / Reset <br />RD-20 <br />Trouble Relay <br />RD-17 <br />Fire Relay <br />DRY CONTACTS (SHOWN DE-ENGERGIZED) <br />AA-01 <br />Audible Alarm <br />SW-04 <br />Door Tamper Switch <br />C NO <br />FS-01 <br />BK WH <br />Fire Stat <br />FS-02 <br />BK WH <br />Fire Stat <br />HIGH TEMP WIRE (842 F), PN: <br />SLPCON-xFT required for all <br />Supervised Loop wiring in contact <br />with a hood. All other wiring shall <br />be PN: 6320UL, Belden or similar. <br />Factory mounted hood sensors will <br />be terminated at junction box on <br />top of hood. <br />PN: <br />GV-1 <br />varies <br />24v DC Gas Valve <br />INTERLOCK FOR AUTOMAN ACTIVATION. Used for <br />activating 120V automan or adjacent Master <br />CORE panels during active Fire Condition. <br />RD-18-1 <br />YW <br />J3-16 <br />J3-8 <br />LT-6 <br />R <br />FIRE INDICATOR <br />DIP Switch <br />ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD <br />BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. <br />RD/GNRDRD-19 <br />Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill <br />Switch, wire EKC and EKS terminals to like <br />terminals in UDS panel. <br />RD-19-1 <br />EKC <br />EST <br />EKS <br />YW <br />INTERLOCK FOR AUTOMAN ACTIVATION. Used for <br />activating 120V automan or adjacent Master <br />CORE panels during active Fire Condition. <br />RD-18-1 <br />YW <br />RD OR/BLRD-18 <br />Auxiliary Interlock Relay <br />PN: <br />FS-XX <br />12-F28021-000360 <br />Duct Fire Sensor <br />PN: <br />LT-05 <br />WL-1090D3-28V <br />24V YLW Ind. Light <br />PN: <br />PS-01 <br />Station STI-SS2431 <br />Remote Puill/Push <br />FOR SHIPMENT <br />J10-1 <br />J10-2 <br />J10-3 <br />J10-4 <br />RD <br />BK <br />BK <br />RD <br />101 <br />102 <br />103 <br />104 <br />MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. <br />Multiple manual actuation possible. <br />A Plug jumper with wires from pin1 to pin4 and from pin2 <br />to pin3 should be mounted on J10 if there is no manual <br />actuation device and no microswitch. <br />MAD-01 <br />C NO <br />Manual <br />Actuation <br />Device <br />MS-01 <br />C NO <br />Micro SW <br />1 2 3 4 5 6 7 8 <br />SW <br />1 <br />ON <br />PUT END OF LINE PLUG IN EMPTY RJ45 <br />J3 <br />ECPM03 <br />UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. <br />CAT-5 WIRING (MASTER ONLY) <br />FIELD WIRED IF REMOTE PREWIRE <br />PN: <br />RD-XX <br />PLC-RPT-24DC/21 <br />24VDC Phoenix Relay <br />AUX-01 <br />AU1 AU2 <br />Auxiliary Interlock (AUX-01): <br />Wire AU1 / AU2 of adjacent Master CORE panel(s) in <br />each manual activation loop for simultaneous <br />activation. <br />AU1/AU2 will have continuity for 10 seconds if adjacent <br />panel goes into fire condition, activating this CORE <br />Panel but allowing for a reset after 10 seconds. <br />NOTE: AU1/AU2 terminals of CORE Panel should not be <br />wired into its own manual activation loop. <br />Adjacent <br />CORE Panel <br />Master CORE set <br />DIP SW 8 to CLOSED <br />position. Slave <br />CORE with address 1 <br />set DIP SW 8 to <br />CLOSED position. All <br />other CORES set DIP <br />SW 8 OPEN. <br />18AWG <br />LEGEND <br />FIELD WIRING <br />FACTORY WIRING <br />BK- BLACK <br />BL- BLUE <br />BR- BROWN <br />OR- ORANGE <br />WH- WHITE <br />OR/BL- OR/BL STRIPE <br />BL/RD- BL/RD STRIPE <br />RD/GN- RD/GN STRIPE <br />WH/BL- WH/BL STRIPE <br />YW- YELLOW <br />GY- GREY <br />PR- PURPLE <br />RD- RED <br />GR- GREEN <br />FIRE INDICATOR FAULT CONDITION FLASH CODES <br />2 Release Solenoid <br />3 Pressure Switch <br />4 Auxiliary Fault <br />5 Microcontroller Fault <br />6 N/A <br />7 Supervised Loop <br />8 Ground Fault <br />9 Surfactant Low <br />10 Battery Voltage Low <br />11 AC Power Failure <br />12 Door Tamper Switch <br />13 Test Mode <br />14 CORE Interlock Network <br />15 Fault on Hood in Interlock Network <br />16 Fault on PCU in Interlock Network <br />FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 <br />& AL2 make in FIRE. <br />To Building Fire Alarm <br />Panel <br />J9 <br />AL1 <br />AL2 <br />J3-7 <br />FIRE SYSTEM DRY CONTACTS. <br />Dry contacts will make C2 to AR2 when system is <br />armed. <br />RD-17-1 <br />C2 <br />AR2 <br />14 AWG <br />YW <br />TROUBLE RELAY. Contact terminals TBC & TBL <br />make if there is trouble. Contact terminals TBC & <br />TOK make if the system is ok. <br />RD-20-1 <br />TBC <br />TBL <br />TOK <br />YW <br />RD PS OR J4-9 <br />PN: <br />PS <br />EWC-PRESSURE <br />Pressure Switch <br />PR RS <br />SW-05-1 <br />Test Armed <br />3 4 YW RS-1 <br />RELEASE SOLENOID <br />BLBR <br />RD ORSW-05-3 <br />Test Armed <br />3 4 J4-13 <br />PN: <br />SW-05 <br />ZB5AD2 <br />TEST/ARM Switch <br />RS2PRSW-05-2 <br />Test Armed <br />3 4 YW <br />PS-1 <br />Pressure Switch <br />WH <br />PN: <br />PWS-01 <br />24VDC 18W POWER <br />24VDC Power Suppl <br />CA <br />CB <br />CC <br />AU1AU1 <br />AU2AU2 <br />TR2 <br />PN: <br />MAD-01 <br />DEVICE <br />MANUAL ACTIVATION <br />GAS VALVES SHOULD BE WIRED TO MASTER <br />CORE BOARD ONLY. <br />RDRD <br />GV-1 <br />24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC POWERED <br />GAS VALVES ONLY. <br />(2nd Contact) <br />7480959 <br />Food-to-Go - 328... <br />FACTORY <br />SC-311110MA <br />4/21/2025 <br />ECP #1-7 <br />Fire System #1 TANK FS - 4.0/4.0. <br />FS-1: MASTER <br />M2.5 <br />SPECIFICATIONS <br />FIRE WIRING <br />SHEET <br />TITLE <br />PROJECT <br />TITLE <br />NO <br />. <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />THESE DRAWINGS & SPECIFICATIONS ARE THE <br />EXCLUSIVE PROPERTY OF TND STUDIO. THE USE <br />OF THESE PLANS AND SPECIFICATIONS SHALL BE <br />RESTRICTED TO THE ORIGINAL SITE FOR WHICH <br />T H E Y W E R E P R E P A R E D . R E P R O D U C T I O N , <br />PUBLICATION OR RE-USE, IN WHOLE OR IN PART <br />IS PROHIBIT ED W ITH OUT THE EXPR ESS PR IOR <br />W RITTEN C ONSE NT OF TN D STUD IO. T ITLE TO <br />T H E D R A W I N G S R E M A I N S W I T H T N D S T U D I O <br />W ITH OUT P REJU DI CE. VISUAL C ONTAC T WI T H <br />T H E S E P L A N S A N D S P E C I F I C A T I O N S S H A L L <br />C ON S T I T U T E PR I M A -FAC I E EVI D E NC E OF T H E <br />ACCEPTANCE OF THESE RESTRICTIONS AND THE <br />T E R M S F O U N D H E R E I N . <br />CLIENT <br />STAMP <br />SHEET <br />KITCHEN HOOD